Loading…
Loading…
Tender Value
₹5.6 Cr
EMD Value
₹4.3 L
Closing Date
30 Jan 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELECT G
13 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar Nature of Work are as follows for this work:- (i) Electrification of Service Building. (ii) Electrification of Staff Quarters. (iii) Electrification of Offices. (iv) Electrification of Road and Colony Lighting. (v) Electrification of Circulating Area Lighting. (vi) Erection & commissioning of LT, HT upto 33 KV overhead mains. (vii) Substaion Installation & commissioning. (viii )Electrification of Washing Pits , Sheds & Workshops etc. (ix) Any above work or combination of (i) to (viii) above.
15 conditions · 4 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Three Miscellaneous work (i) Rewiring of service building including replacement of damaged earthing in Jabalpur Division ( station , service building, shed, rest house etc.) (ii) Improvement in illumination level at LC gates by providing Octagonal pole , track crossing lights in JBP Division including street light (iii) Miscellaneous left over work in connection with BINA-KTE 3rd line project
JBP-L-T-No-44-2025~WCR
JBP-L-T-No-44-2025
Open
Works - General
12 Months
Jabalpur, Madhya Pradesh
₹0
₹4.3 L
30 Jan 2026
8 Jan 2026
16 Jan 2026
243 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,34,74,768.08 | ||
| — | Item Breakup | for details. | — | ||
| SDB for light and fan. TPN DB 4 way (8+12) IP-43 with metal door, 4 with ELCB, RCCB 32A TPN incomer and outgoing having 5 x 10A SPMCB and 5 x 6A SP MCB with pherrol MCB make - Legrand, Havells, Hager, simens or equivalent , | — | — | — | 5,70,311.6 | |
| — | Item Breakup | for details. | — | ||
| "SDB for Power. TPN DB 4 way (8+12) IP-43 with metal door, with ELCB, RCCB 63A TPN incomer and outgoing having 5 x 32A SPMCB and 5 x 20/16A SP MCB. MCB make - Legrand, Havells, Hager, simens or equivalent " | — | — | — | 4,97,548.5 | |
| — | Item Breakup | for details. | — | ||
| "Supply and Erection of Ceiling fan including electronic modular fan regulator, suitable down rod , Metal fan hook, flexible Pipe, with all necesaary arangment (BLDC, 5 star rated, 1200 mm Make- Atomberg, Usha , Bajaj,Havells or simillar make) Sample will be approved by comptent authority befor supply " | — | — | — | 4,92,176.4 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of E/Fan 380mm sweep Erection includes and fixing is to be done on already provided finished opening in the wall using required fasteners , their grouting and then connection is to be given from ceiling rose to this fan using cable of 1.5 sq. mm . size. | — | — | — | 2,19,616.8 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of 1 x 18/20W LED fittings 4 feet length. The fittings shall have to be erected by the contractor with all fixing accessories/MS clamps, nuts bolts etc. as per requirement at site. " | — | — | — | 2,98,370.4 | |
| — | Item Breakup | for details. | — | ||
| "Supply, erection , testing and comssioning of 2X2 LIGHT 36W Led Recessed Luminaire IS:10322/part5/sec-2/2012 and IS 16107 (Part 2/Sec 1) : 2012 for Recess type Sample will be approved by comptentauthority befor supply Make- Syska, Havells, Wipro, Bajaj, Crompton or equivailent | — | — | — | 3,65,310 | |
| — | Item Breakup | for details. | — | ||
| Point Wiring : This includes provision of wiring with 1.5 sqmm copper starnded PVC insulated wire [ L & N and earth ]from MDB/SDB/ Board to light & fan control board and provision of control switch on common light and fan control board , together with wiring from control board to ceiling rose and provision of ceiling rose , holder on board ; with earth continuity wire; independent for each fitting. Cost of this item is inclusive of distributed cost of common board & wiring from MDB/SDB/Board to common board in addition to items specifically mentioned Make- Legrand. Havells, L&T, ABB or equivailent | — | — | — | 16,94,745 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x2.5 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 2.5 sqmm with one wire of 1.5 sqmm for earth conn). | — | — | — | 4,65,215 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x4 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of4 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 3,53,700 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x 6 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 6 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 3,41,925 | |
| — | Item Breakup | for details. | — | ||
| "16A & 6 pin socket point on separate circuit and board. Make Havells, Wipro, legrand, Bajaj or equivalent." | — | — | — | 1,49,676.8 | |
| — | Item Breakup | for details. | — | ||
| 5 pin 5A on separate boards: wires shall run separate from SDB Havells, Wipro, legrand, Bajaj or equivalent. | — | — | — | 83,394.5 | |
| — | Item Breakup | for details. | — | ||
| 6A 5 pin socket point on fan and light control board Havells, Wipro, legrand , Bajaj or equivalent. | — | — | — | 25,364.5 | |
| — | Item Breakup | for details. | — | ||
| Concealed Wirings:25A/32A MCB and socket for air conditioner / Gyser/ Water cooler: (modular) Havells, Wipro, Orient, Bajaj, crompton or equivalent | — | — | — | 1,75,699.5 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Four module box of Havells, Wipro, Orient, Bajaj or equivalent | — | — | — | 14,103.6 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Six module box of Havells, Wipro, Orient, Bajaj or equivalent. | — | — | — | 24,472.5 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Eight module box of Havells, Wipro, Orient, Bajaj or equivalent. | — | — | — | 34,602 | |
| — | Item Breakup | for details. | — | ||
| Concealed metal box boards Supply, fixing of concealed metal box boards + modular sheet plate suitable for modular switches/sockets/regulator/AC point/Geyser etc. front open type (for concealed wiring). This includes masonry work happened at the time of execution of the work and its associated repairs. All material required for this job will be supplied by contractor. Twelve/Eighteen module box of Havells, Wipro, Orient, Bajaj or equivalent. | — | — | — | 54,184.5 | |
| — | Item Breakup | for details. | — | ||
| PVC conduit 25 mm dia as per IS-9537 (HMS) | — | — | — | 2,17,840 | |
| — | Item Breakup | for details. | — | ||
| Cutting of wall for insertion of 1" dia PVC conduit, fixing hardwares for fixing the conduit along with its supply and then replaster it with cement and sand mixture and then painting with matching colour as per existing colour of the wall. Proper joints in pipes, bends/elbows/ junctions are to be provided as per site requirement | — | — | — | 2,38,512 | |
| — | Item Breakup | for details. | — | ||
| Supply & Erection cable trays of size 300 mm width made out of angle 50 x 50 x 6 mm and flats ofsizes 50 x 6 mm as perexplanatory notes.including all accessoriers for fittings suitable MS angle duly painted | — | — | — | 7,52,694.5 | |
| — | Item Breakup | for details. | — | ||
| Point wiring for High bay /Mid bay light fitting in Industrial shed :Supply of material and wiring of light point in 25 mm diasteel conduitand 4 sq.mm. Copper wire PVC cable along with ceiling rose and junction box for making wiring point of highbay/ Mid bay light fittingin the industrial shed . Wiring will have 14 SWG copper earth wire along with the wire. Separate phase & neutral Coppre wire shall run forwiring purpose.(Dismantling of exxissting point wiring and material transported to nearest Depot) | — | — | — | 27,23,616.3 | |
| — | Item Breakup | for details. | — | ||
| Supply Erection testing and commissioning of LED Luminaire for High bay lighting (Q3) as per Catalogue refrence no. UFOseries 150 Watt Highbay or Equivalent Make- Havells, Syska, Crompton, Bajaj, or equivailent (Dismantling of exxissting fitting and material transported to nearest Depot) | — | — | — | 72,93,596.7 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of LED(100W) IP66 Flood light fitting in industrial shed with suitable clamps, fixtures, nut, bolts etc. for fixing the fitting and fixing of GI pipe on the truss with proper clamping arrangement for powersupply arrangement. It alson includes power supplyconnection to the fitting & its testing &commissioning.Warranty for free replacement (in years) 5 Make- Orient, crompton , Syska, Goldwyn, Havells or equivailent | — | — | — | 17,77,600 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of 36 W LED street light fittings suitable for 230V AC, 50 Hz comprise a single piece deep drawn alluminium housing IP-65 colour temp 5500- 7000K with connection , 1.5 mtr GI pipe tc. with suitable fixtures and clamps etc. Havells, Phillips, Orient, Bajaj or equivalent. | — | — | — | 6,77,092.7 | |
| — | Item Breakup | for details. | — | ||
| Supply and erection of outdoor control box of IP54 degree of protection,Switch On-Off street lights on time scheduling basis by incorporating an analog/digital time switch and contactor, 32A 230 V 3P Timelite Distribution Boards-Analog Time Switch,IS/IEC 13947-27 Make- Havells, C&S, or simillar | — | — | — | 2,57,558.75 | |
| — | Item Breakup | for details. | — | ||
| Pipe Earthing : Supply of material for Earthing pit as per IS-3043, Erection includes excavation of earth, filling of salt, charcoal, B class GI pipe with funnel at top with cast iron cover having handle and cement concrete chamber, 8 SWG GI wire pit to SDB etc. as per IS latest with inscription ligibility of IR value on top of earth pit chamber with serial no-etc.Then testing with earth tester. | — | — | — | 2,39,271.6 | |
| — | Item Breakup | for details. | — | ||
| Provision of maintenancefree earthing. | — | — | — | 5,37,537.6 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of 8 SWG GI wire | — | — | — | 4,931.25 | |
| — | Item Breakup | for details. | — | ||
| Supply & erection of GI earth strip 30/25 x 5 mm | — | — | — | 9,822 | |
| — | Item Breakup | for details. | — | ||
| Cable laying inside pipe on road/track crossing and reforming original surface of the road/track.Cable laying on wall/pole/PVC cable duct/MS trays as per notes | — | — | — | 92,576 | |
| — | Item Breakup | for details. | — | ||
| Double Cable laying in trench : This involves Excavation of 1000mm deep, 300 mm wide trench in soil/hard murrum/tar road/below Railway track . Then the bottom of the trench should be levelled , freed from stones / sharp edges of rocks . After this the cable shall be laid and then both sides are to be covered with bricks. The rest of the trench to be refilled by sheaved earth.Cables shall be supplied by Railways and the same shall be collected by the contractor from Electrical stores depot. | — | — | — | 90,720 | |
| — | Item Breakup | for details. | — | ||
| Cable laying single in earth : Cable laying in trench : This involves Excavation of 1000mm deep, 300 mm wide trench in soil/hard murrum/tar road/below Railway track . Then the bottom of the trench should be levelled , freed from stones / sharp edges of rocks . After this the cable shall be laid and then both sides are to be covered with bricks. The rest of the trench to be refilled by sheaved earth.Cables shall be supplied by Railways and the same shall be collected by the contractor from Electrical stores depot. | — | — | — | 75,315 | |
| — | Item Breakup | for details. | — | ||
| — | Item Breakup | for details. | — | ||
| — | — | — | 53,231.4 | ||
| — | — | — | 76,300.95 | ||
| — | Item Breakup | for details. | — | ||
| Supply and erection of 50 mm dia GI pipe B class. | — | — | — | 11,063.8 | |
| Supply, erection, testing & commissioning of Air circulator fan of 750 mm sweep wall mounting type without regulator suitable for single phase, 230V and fixtures, clamps, nuts and bolts etc including civil worksof fixing the fan and finishing the same. make- Bajaj, Anchor, Havells, Crompton or equivailent | — | — | — | 4,39,821.85 | |
| Dismantling of old points with transportation to concerned railway depot with proper accountal | — | — | — | 33,827.5 | |
| Supply instaltion testing and comssioning of Industrial socket point 63 Amps 5 pin make- Hensel, C&S,Havells, legrand or simillar | — | — | — | 1,95,211 | |
| Supply instaltion testing and comssioning of Industrial socket point 125 Amps 5 pin make- Hensel, C&S,Havells, legrand or simillar | — | — | — | 3,99,080.2 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AC08to10.pdf
ATTACHMENT
44-2025tenderdoc.pdf
ATTACHMENT
GCCcorrectionslips.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .