Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.6 LAccepted-Finance | 1 | Accepted-Finance L1 LOWEST BIDDER | |
| 2 | 2₹2.9 L+₹29,677 (11.5%)Rejected-Finance | 2 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 3 | 3₹3.6 L+₹1.0 L (39.5%)Rejected-Finance | 3 | Rejected-Finance RATES ARE ON HIGHER SIDE | |
| 4 | 4₹3.8 L+₹1.2 L (47.7%)Rejected-Finance | 4 | Rejected-Finance RATES ARE ON HIGHER SIDE |
Tender Value
₹3.2 L
EMD Value
₹3,500
Closing Date
10 Feb 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC AZAMGARH
220KV S/S COLONY HAFIZPUR AZAMGARH
INSTALLATION AND COMMISSIONING OF 132 KV BUS BAR PROTEACTION PANEL AT 400KV S/S KASARA MAU UNDER ELECTY 400KV S/S DIVISION KASARA-MAU.
2024_UPTCL_988520_1
46/AETC/2024-25
Open Tender
Electrical Works
Item Wise
60 days
KASARA-MAU
UTR SLIP OF EMD TENDER FEE PAN CARD GST CERTIFICATE WORK EXPERIENCE etc.
2 documents required · 2 mandatory
₹590
SE ETC UPPTCL AZAMGARH
₹3,500
21 Feb 2025
31 Dec 2024
10 Feb 2025
31 Dec 2024
10 Feb 2025
31 Dec 2024
31 Dec 2024 - 10 Feb 2025
Laying and Jointing PVC Pipe. Heading
Installation & Commissioning of 132KV Bus Bar Protection Panel (Nelumbo make) along with other assoctaed works at 400KV S/S Kasara, Mau with all cost of Men, Misc, Consumables, T&Ps, etc. Required for satisfactory completion of the Job, as per Technical Specifications & Direction of the Supervisiong Engineer, As per details below: Preparation of Inter Connection Wiring Daigram and cable schedule for new 132KV Bus Bar Protaction Panel( Nelumbo make) drawing and 132KV Isolators and CBs (as required) to complete the Job satisfactory and providing of Wiring Schedule Drawing in 3 Set as per executed Inter Connection Wiring Diagram.
Erection of New 132KV Bus Bar Protection Panel (Nelumbo make) at suitable place in control room as per instruction of supervising Engineer after shifting of the same from storage place to erection site including earthing of panels, filling of the gap between panels by MS sheet and painting it by appropriate colour.
Making Inter Connection Wiring of 15 No. 132KV Feeder Bay to connect each feeder to 132KV Duplicate Bus Bar Protection Panel, Termination of all internal connection wiring of all 15 Nos. 132KV Bays as per prepared Internal Connection wiring Diagram. Internal wiring shall be made with crimping type and tinned copper lug with insulation sleeves and shall be provided with proper ferrules at both ends and ferrules should be marked with corresponding panels at both ends wire including all consumable materials such as : 1.5/2.5mm2 flexible cables, lugs, gland, ferrule etc. excluding control cable and manpower to assist the panel manufacturing company commissioning engineer at site till works complete in all respect.
Laying of control cable from different 132KV Isolators/ CBs to appropriate C&R Panels/ Bus Bar Control Panels in control room as required for status in 132KV Bus Bar Protection panel. The work also included checking and tracing of existing control cables from different 132KV Isolator to C&R Panels 7C x 2.5 mm2
Termination of above laid control Cable from both sides as per schematic drawing & cable schedule including glanding, proper ferruling, dressing, Tying and Tagging of Cables. (Both ends Termination of control cable will be considered as 1 No.)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .