Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹42.0 L+₹6.0 L (16.7%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹47.8 L+₹11.8 L (32.9%)Rejected-AOC 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
8 Aug 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8354 REPAIRS AND MAINT TO FITTINGS / FIXTURE, DBS ELECTRICAL PROTECTIVE SYSTEM, ELECTRICAL WIRING, SUBMAIN WIRING, LIGHT FITTINGS, EARTHING AND OTHER MISC ELECTRICAL WORK IN CHSC AND OTHER CONNECTED AREA UNDER GE SOUTH PUNE
2022_MES_537490_1
8354 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹88,000
4 Oct 2022
12 Jul 2022
10 Aug 2022
12 Jul 2022
8 Aug 2022
26 Jul 2022
Amount
M & L for Attending emergent complaints i.e No light/ceiling fan/ exhaust fan/ geysers/ security light/ ceiling and wall light /Cable fault of any size & type / earth leakage/ short circuit / neutral break mains / substations / internal circuits of existing system of main building / block, making continous electric supply including carrying out minor repairs etc as required to make the system in order / functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire, cable jointing complete all as specified and directed. [Note : (i) Rate of Fuse wire, copper cable, copper thimbles, glands, earthing wire are deemed to be considered in this item (ii) Zone-1 and Zone-2 area of new CH(SC) as well as residential accn under GE(South) Pune AOR as directed by Engr in Charge to be present daily round the clock including Sunday for attending emergency complaint and other day to day no light complaint as per site requirement. (iii) One electrician and one helper to be deployed during the contract period. If found absent recovery of Rs 1600/- will be deducted per day for each person]
(iii) Attending complaints in COVID Hospital like New CH(SC), Old CH(SC), AICTS, ALC where FGM / Electrician with helper has to go inside COVID WARD where COVID POSITIVE patient are treated, if complaints are not attended in that case penalty will be 5 times the minimum wages of FGM / Electrician will be deducted till complaints are not attended and decision of GE will be final & binding. (iv) All protection like PPE Kit and other safety measures will be provided by Hospital Authority. (v) Necessary insurance coverage should be taken for their all staff by the bidder before commencement of the works. (vi) All rates for the above are deemed to be included in Sch 'A'(BOQ) items (vii) Attending four number of complains shall be measured as one job.
Taking down carefully exising unserviceable aluminium point wiring any type (light, fan, socket or power), complete including fitting such as switches, ceiling rose, pendent, regulators etc removing the material from site for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down unserviceable sub main wiring of any size and making good the disturbed surfaces.
M & L for Point wiring using approved colour coding as per IS, with taking down multistranded copper conductor 1.5 Sqmm (nominal area), single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping ISI marked including all accessories etc, surface mounted with GI box /PVC surface mounted modular box with earth dolly , covered with modular white cover plate with frame suitable for modular switches including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one way switch 5 Amps
One fan point with regulator / exhaust fan point controlled by one way switch 5 Amps
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One bell point controlled by bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sr. item 4.00 above but using 2.5 sq mm single core copper conductor cable of multistranded FRLS cable PVC insulated unsheathed 1100 volts grade for 5/15 amps point including PVC insulated multistranded copper conductor 2.5 Sqm single core FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping ISI marked including all accessories etc, surface mounted as per site requirement with mild steel sunken boxes / PVC surface mounted box with earth dolly duly, covered with laminated hylem sheet/ PVC cover , ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
One light point controlled by TWO WAY switches 5 Amps all as directed.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One bell point controlled by bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Ser. item No. 6.00 above but using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps point including PVC insulated multistranded FRLS cable of 2.5 sqmm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and as directed.
M & L for Point wiring with colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable drawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, incl making good of disturbed surface and finish with two coats of white / colour washing / distempering etc to match the existing surface complete etc heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
One light point controlled by TWO WAY switches 5 Amps all as directed.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Ser. item No. 8.00 above but using 2.5 sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps point including PVC insulated multistranded FRLS cable of 2.5 sq mm copper conductor as earth continuity conductor along with wiring and connecting to the common eath dolly complete all as specified and as directed.
S & F Modular Switch piano flush type, single pole, one way, and 6 Amp single module complete all as specified.
S & F Modular Switch piano flush type, single pole, one way, and 16 Amp single module complete all as specified.
S & F Modular Socket outlet 6 Amp multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, 2 module piano flush type complete all as specified.
S & F Modular Switch Socket outlet 6/16 Amp multipurpose having provision for 3 pin, 16 Amp and 3 pin,6 Amp, 2 module piano flush type complete all as specified.
S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F Bell push modular 6 Amps single module complete all as specified.
S&F Bell Push flush type 5 Amps, 240 volts complete all as specified.
Suply and fix Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
S&F lamp holder insulated body with back plate PVC/Polycarbonate type with cord grip cap, angular type fixed on wall incl 9 watt LED lamp complete all as specified.and directed.
S & F for Ceiling rose, surface Bakelite suitable ISI marked PVC 50mm dia, 3 terminals including PVC mounting block complete all as specified and as directed.
S & F for Switch piano flush type, single pole, one way, and 5 Amp complete all as specified.
S & F for Switch piano flush type, single pole, 5 Amps TWO WAY SWITCHES, complete all as specified.
S&F switch piano flush type, 15 Amps single pole one way fixed and connect as per existring complete all as specified. and directed.
S & F Socket outlet multipurpose having provision for 3 pin, 5 Amp and 2 pin, 5 Amp, piano flush type complete all as specified.
S&F socket 5/15 Amp multipurpose and with, single pole one way complete all as specified. and directed.
Supply and Fix LED security light fitting 25 Watts in aluminium housing with glass cover and lens in frame suitable for mounting on & including bracket made of 40mm dia GI pipe bend to shape including taking down existing any type of fittings all as specifed and directed [Make -Crompton cat no - LSTS-25-CDL OR equivalent in / Bajaj / WIPRO]
Supply and Fix in repair LED security light fittings 30 Watts in aluminium housing with glass cover and lens in frame suitable for mounting on & including bracket made of 40mm dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed [Make -Crompton cat no - LSTS-30-CDL OR equivalent in / Bajaj / WIPRO]
Supply and Fix post top lantern LED type 50 Watts including taking down existing any type of fitting complete all as specified and as directed. [Make - HAVELLS cat no - RUBYMAXIPT50WLED757PSYMTOPC or equivalent in Bajaj / Wipro /PHILIPS]
Supply and Fix post top lantern LED type 35 to 45 watts including taking down existing any type of fitting complete all as specified and as directed. [Make - HAVELLS cat no - CORALPT35WLED757PSYMTOPC or equivalent in Bajaj / Wipro /PHILIPS]
Supply and Fix in repair Rectro fit 4 pin LED with direct plug and play complete all as specified and as directed. [Make - JAGUAR (Dazzle) equivalent in Havells / Bajaj / Syska / WIPRO]
Supply and Fix LED Flood light fitting 40 Watts including taking down existing any type of fitting complete all as specified and as directed.
Supply and Fix MCCB 63/100 Amps, 16 KA, 4 Pole,415V complete all as specified and as directed.
Supply and Fix MCCB 125 Amps, 16 KA, 4 Pole,415V complete all as specified and as directed,
Supply and Fix MCCB 160 Amps, 25 KA, 4 Pole, 415V, complete all as specified and as directed.
Supply and Fix MCCB 200 Amps, 25 KA, 4 Pole, 415V, complete all as specified and as directed.
Supply and Fix MCCB 250 Amps, 25 KA, 4 Pole, 415V complete all as specified and as directed.
Supply and Fix MCCB 400 Amps,25 KA, 4 Pole, 415V, complete all as specified and as directed.
S&F Metal plug and socket -2 pin and earth plug and socket with and including 20Amps MCB SP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and as directed.
S&F sheet metal enclosure TPN with three pin and earth plug with socket complete with one triple pole 32 Amps MCB concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified and as directed.
M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to and including Galvanised steel earthing wire 4mm dia by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including RCC 1: 2 : 4 type B-1 earth pit with cover, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion.
M & L for Earthing complete with galvanised steel earth plate electrode '60cm × 60cm × 6mm thick, buried 'directly in ground (earth pit not less 'than 2.25 metres deep below normal ground 'level) with top edge of the plate not 'less than 1.5 metres below normal ground level', connected to 'galvanised iron strip 32x6mm by means of bolts, nuts, check 'nuts and washers of galvanised iron or steel earth strip protected by provision of GI 'medium grade' pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B1 (using 20mm graded stone aggregate) with 40mm thick cover in RCC (1:2:4) type B-1 reinforced with XPM (weight not less than 4 kg/sqm) and frame made out in MS angle iron of size 25x25x3mm with lugs 02 Nos and with MS handle made in 6mm dia round bar made to shape, including GI 'medium grade' 20mm bore pipe for watering, perforated at bottom 1.75m long placed on top edge of earth plate including including provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate, test point made out of phosphorus bronze with fixing arrangement ,funnel, wire mesh and earth work in hard/dense soil returning filling in and removal of surplus soil to a distance not exceeding 50mtr all as shown in electrical plate No. 3 of SSR Part I 2009 connected to earthing test point all as specified or indicated 'including testing on completion. (NOTE:-GI strip and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to be included in the unit rate.)
M&L for chemical earthing with copper pipes of 80mm outer dia and copper pipe 40mm inner dia of 3 mtr length and the cavity filled with highly conductive, non corrosive materal with supply of fast electrode earth enhancement compound (2 bags of 25 Kg) which is highly hygroscopic, non magnetic and non corrosive in nature & good PH value certified by NABL approved lab with copper earth strip 32 x 6 mm (with nuts, bolts & check nuts) and riveted to earth electrode in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer complete with earth pit in PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate, RCC cover including necessary excavation and earth work, etc complete all as specified and as directed. [Note : (i) The earthing result should not be less than 1 ohm and testing equipment shall be provided by contractor on no any extra cost. (ii) Copper Strip 32 x 6 mm and GI pipe 40mm bore medium grade for encasing GI strip upto 7.50m length per earthing shall be deemed to included in the quoted rate.]
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.
All as per Ser. Item No. 42.00 above but 6 mm dia GI Wire complete all as specified and directed.
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 20-40 Amps, 10KA, 240V,'C' series complete all as specified and as directed.
S&F in replacement MCB TP 40/63 Amps, 10KA, 415 V,'C' series complete all as specified and as directed.
S&F in replacement MCB TPN 40/63 Amps, 10KA, 415V,'C' series complete all as specified and as directed.
S&F in replacement RCCB 40 Amps, 100mA, 2 Pole, 240V complete all as specified and as directed.
Supply & fix LED tube light fitting 18/20 Watt 4 feet long, T-8 rectrofit tube including taking down tube light and choke from any type fitting and making all connection complete all as specified and directed. (Make :- BAJAJ cat no-830148 OR equivalent in crompton /philips/Wipro / )
M & L for LED pannel Recess mounted -2'x2' - 36 watts light fitting with heat exchanger unit complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting conforming to Cat Part Make - WIPRO Cat No- CRCO10R038HP57GL1 or equivalent of BAJAJ /Philips/CROMPTON
Supply and fix LED batten neptune silver tube light fitting complete with all fitting and fixing accessories, 4 Feet, 1X20Watt pre-wired with high efficiency electronic driver, glare free, smooth light distribution conforming to CAT Part No. HPL - HLPT51820PCGCW or equivelent in of Wipro / Philips/BAJAJ/Halonix complete including taking down any type fitting all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement 15A plug top and connection complete all as specified and as directed.
Supply & fix LED batten 10 watt CDL plastic tube light fitting complete all as specified and directed including taking down existing holder/fitting all as directed. (Make :- BAJAJ-830206 or equivelent in WIPRO / Philips/ Halonix)
Supply & fix LED PL Lamp 18 watt 4 pin indoor decorative LED extruded aluminium (powder coated) anodized with opal diffuser, 2G11 pin, IP20 suitable for existing fitting complete including taking down existing all as directed. (Make :- Halonix-HLL-01-18-CW or equivelent in WIPRO / Philips)
Supply & fix LED PL Lamp 10 watt 4 pin indoor decorative LED extruded aluminium (powder coated) anodized with opal diffuser, 2G11 pin, IP20 suitable for existing fitting complete including taking down existing all as directed. (Make :- Halonix-HLL-01-10-CW or equivelent in WIPRO / Philips)
Supply & fix LED recess mounting downlighter 12 watt with LED backlit round downlighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20 including taking down existing all as directed. (Make :- Halonix-HLDLR-31-12-CW or equivelent in WIPRO / Philips)
Supply and fix in replacement unsv LED indoor driver for LED fitting 10 to 35 Watts of the existing make including connection complete all as specified and directed
Supply and fix in replacement unsv LED indoor driver for LED pannel Recess mounted -2'x2' - 36 watts of existing make including connection complete all as specified and directed
Supply and fix in replacement unsv LED indoor driver for LED pannel Recess mounted -2'x2' - 50 watts of existing make including connection complete all as specified and directed
Supply & fix in repair Chock electronic Ballast SLIM Type 36/40 watt commercial type fixed in existing make complete all as specified and as directed.
Supply & fix in repair Chock electronic Ballast SLIM Type 18/20 watt commercial type fixed in existing make complete all as specified and as directed.
Supply and fix in replacement unsv LED out door driver for LED fitting 60 to 90 Watts of the existing make including connection complete all as specified and directed
Supply and replace old unserviceable LED out door driver for LED fitting120 to 150 Watts of the existing make including connection complete all as specified and directed
S&F in repair IP-43, protection metal double door Vertical TPN - DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blank plates, cable ties, identification labels TPN 4 way, 12 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Note - MCCB 100 Amps 4 pole 16 KA as incomer will be measured seprately in relevant item)
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blank plates, cable ties, identification labels TPN 8 way, 24 modules suitable for accommodating 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed (Note - MCCB 100 Amps 4 pole 16 KA as incomer will be measured seprately in relevant item)
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blank plates, cable ties, identification labels TPN 12 way, 36 modules suitable for accommodating upto 160 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed (Note - MCCB 160 Amps 4 pole 25 KA as incomer will be measured seprately in relevant item)
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated busbar, 415 volts, 50 HZ complete with interconnection links, blank plates, cable ties, identification labels TPN 4 ROW of, 10 modules suitable for accommodating upto 40 nos SP/ TP/ TPN MCB as Incoming / out going and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing make complete all as specified and as directed
S&F in repair, IP-43 ,MCB DB 4 way ,double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing make complete all as specified and as directed
S&F in repair, IP-43, MCB DB 8 way, double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing make complete all as specified and as directed
S&F in repair, IP-43 ,MCB DB 12 way ,double door, with 100 amp rated busbar 240 V, SPN concealed / surface on wall as directed by Engr in charge including cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing make complete all as specified and as directed
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 10Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor FRLS cable drawing into and including rigid non metallic PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One run of conduit and four runs of 10 sqmm cable and two runs of 10 sqmm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor FRLS cable drawing into including rigid non metallic PVC heavy duty conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc including all cutting / chases etc in any type of wall, making good to walls etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One run of PVC conduit and four runs of 6 sqmm cable and two runs of 6 sqmm cable earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor FRLS cable drawing into including rigid non metallic, heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall , making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:- One run of conduit and two runs of 6 sqmm cable and One run of 6 sqmm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor FRLS cable drawing into and including PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One run of conduit and two runs of 4 sqmm cable and One run of 4 sqmm earth shall be measured as one unit length.)
M&L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One run of PVC casing capping and Two runs of 4 sqmm cable and One run of 4 sqmm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One run of PVC casing caping and two runs of 6 sqmm cable and One run of 6 sqmm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:- One run of PVC casing caping and four runs of 6 sqmm cable and two runs of 6 sqmm earth Cable shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 10 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including ontinuous earth wire of size 10Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor FRLS cable including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour wash / distemper etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One run of PVC casing caping along with four runs of 10 sq mm wire and two runs of 10 sqmm earth wire shall be measured as one unit length.)
Supply and fixing ceiling fan regulator, electronic, flush type, rotary steps, hum free, AC, 230 volts, 100 watts, complete all as specified & directed.
S&F in repairs armoured copper cable PVC insulated 3 core 4.0 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed
S&F in repairs armoured copper cable PVC insulated single core 16.0 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed
S & F in repair modular Black colour plate with frame 2 modules complete all as specified and as directed.
S & F in repair modular Black cover plate with frame 3 modules complete all as specified and as directed,
S & F in repair modular Black cover plate with frame 4 modules complete all as specified and as directed.
Supply & fix in repair existing fan Condenser 2.5 mfd 230 Volts complete all as specified and as directed.
Supply & fix in repair existing fan Condenser 4 mfd 230 Volts complete all as specified and as directed.
S&F in replacement burnt out and unserviceable fan motor assembly complete including double bearing, copper winding with metal plate top & bottom side suitable for 1200 mm sweep complete all as specified and as directed.
Supply and replace fan blade (set of 3) suitable for 1200 mm of existing Make complete all as specified and as directed.
Supply and fix in replace anchor bolt & nut 8 mm dia of the geyser for fixing on wall in a suitable way and making good the distrubed area all as specified and directed
Supply and fix in replace pvc box with 06 Amps switch and socket 06 Amps dully fixed on wall all as specified and directed
Supply and fix in replace pvc box with 16 Amps switch and socket 06 / 16 Amps dully fixed on wall all as specified and directed
Supply only Self adhesive PVC electrical Insulation tape 7 mtr long, ISI mark with superior quality complete all as specified and as directed.
Supply only the following spare parts :-
Bearing 6200 to 6203 ZZ Make - SKF/NBL
Conductor Terminal 3 way Bakelite
Brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan.
Supply and Fix in replacement canopy for ceiling fans (Set of two) complete all as specified and as directed.
Supply and Fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc. suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed.
M&L for replacement of burnt winding of following fans, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and refixing the fan at positions to the satisfaction of Engr-in-charge :-
Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
Exhaust fan upto 250/300/450 mm sweep working on 230 volts AC supply
Wall mounting fan of any 230/450 mm size,working on 230 volts AC supply
S&F in replacement down rod for ceiling fan made out of GI pipe medium grade 15mm dia with fan clamps incl drilling, cutting, threading etc all as directed for ceiling fan 1200/1400 sweep of following sizes:-
2 ft long
3 ft long
4 ft long
Taking down geysers carrying to workshop for leakage repairing , servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for :- (Note:- Heating element, geyser tank, thermostat, indicator lamp & thermal cutout etc shall be measured and paid separately as supply only)
25 liters capacity
50 liters capacity
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only steel tank for 25 Ltrs geyser capacity as per existing geyser complete all as specified and as directed.
Supply only steel tank for 50 Ltrs geyser capacity as per existing geyser complete all as specified and as directed.
Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50/100 liters capacity geyser complete all as specified and as directed.
Supply only thermostat ISI marked complete suitable for 25/50 liters capacity geyser complete all as specified and as directed.
Supply and Fix in replacement 3 pin CFL 3pin 36 watts complete all as specified and as directed.
Supply and Fix in replacement CFL electronic choke 36 watts complete all as specified and as directed.
Supply and Fix in replacement CFL cross 4 pin 10 to 18 watts suitable for downlighter complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 300mm sweep complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 250mm sweep complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 200mm sweep complete all as specified and as directed.
S&F in repairs PVC flexible three core copper wire 23/0.0076 size complete all as specified and directed.
Supply & fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 45/60cm long for cold water as per requirement complete all as specified and as directed
Supply & fix PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 45/60cm long for hot water as per requirement complete all as specified and as directed
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket/switch to geyser complete all as specified and as directed.
Supply and fix in replace multi core flexible copper conductor PVC insulated and sheathed cables 2core 0.75 Sqmm 1100Volt all as specified and directed
Supply and fix in replace flat twin 4 Sq mm with aluminium conductor multistranded black cable as per IS 694-1990 complete all as specified and directed
Supply and fix replace flat twin 6 Sq mm with aluminium conductor multistranded black cable as per IS 694-1990 complete all as specified and directed
RELIABLE ENTERPRISES
KESARI AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .