Construction of ROB No.469 in lieu of closing of Manned level crossing at Km 829/15-17 between Vizianagaram-Korukonda stations with spans:1x60.0m camel type truss girder, 1x30.0 CWG +1X18.0m CG +3x30.0m PSC Girder with RE Walls on East Coast Railway.
DYCEGSUWATENGG2026006
DYCEGSUWATENGG2026006
Open
24 Months
Vizianagaram, Andhra Pradesh
₹0
₹27.4 L
29 Jan 2026
29 Jan 2026
Item- 6 Execution of all items as per Schedule-F.
S No. Item No Description of Item Unit Qty Rate Amount
13.0 FINISHING
13.44S EXTERIOR FINISHING
Finishing walls with Acrylic Smooth
exterior paint of required shade :
13.46.1 New work (Two or more coat applied Sqm 275.04 160.6 44171.42
@ 1.67 ltr/10 sqm over and including
priming coat of exterior primer
applied @ 0.90 litre/10 sqm)
Applying priming coats with primer of
approved brand and manufacture,
having low VOC (Volatile Organic
Compound ) content.
ECOR-CONST-HQ-ENGG/ECOR
13.85.3 With water thinnable cement primer Sqm 2960.45 73.95 218925.28
2 on wall surface having VOC content
less than 50 grams/litre
16.0 ROAD WORK
16.1S ROADS
16.1 Preparation and consolidation of sub Sqm 4920 218.9 1076988
grade with power road roller of 8 to
12 tonne capacity after excavating
earth to an average of 22.5 cm
depth, dressing to camber and
consolidating with road roller
including making good the
undulations etc. and re-rolling the sub
grade and disposal of surplus earth
with lead upto 50 metres.
16.9 Scarifying metalled (water-bound) Sqm 10475 33.3 348817.5
road surface including disposal of
rubbish, lead upto 50 m and
consolidation of the aggregate
received from scarifying with power
road roller of 8 to 10 tonne capacity.
16.30S PREMIX CARPET
Providing and applying tack coat
using hot straight run bitumen of
grade VG - 10, including heating the
bitumen, spraying the bitumen with
mechanically operated spray unit
fitted on bitumen boiler, cleaning and
preparing the existing road surface as
per specifications :
Providing and applying tack coat
using bitumen emulsion conforming
to IS:8887, using emulsion pressure
distributer including preparing the
surface & cleaning with mechanical
With medium setting bitumen
16.49S MISCELLANEOUS
16.50 Providing and fixing Glow studs of Each 1000 206.3 206300
size 100x20 mm made of heavy duty
body shall be moulded ASA (Acrylic
styrene Acrylonitrile ) or HIP (High
impact polystyrene) or ABS having
electronically welded micro- prismatic
lens with abrasion resistant coating
as approved by Engineer in charge.
The glow stud shall support a load of
13635 kg tested in accordance with
ASTM D4280. The slope of retro-
reflective surface shall be 35 (+/-5)
7 degress to base .The reflective panels
on both sides with at least 12 cm of
reflective area up each side. The
luminance intensity should be as per
the specification and shall be tested
as described in ASTM I: 809 as
recommended in BS: 873 part 4 :
1973. The studs shall be fixed to the
Road surface using the adhesive
conforming to IS, as per procedure
recommended by the manufacturer
complete and as per direction of
Engineer-in-charge.
ECOR-CONST-HQ-ENGG/ECOR
Providing and laying Dense Graded
Bituminous Macadam using crushed
stone aggregates of specified
grading, premixed with bituminous
binder and filler, transporting the hot
mix to work site by tippers, laying
with paver finisher equipped with
16.54 electronic sensor to the required
grade, level and alignment and rolling
with smooth wheeled, vibratory and
tandem rollers as per specifications to
achieve the desired compaction and
density, complete as per
specifications and directions of
Engineer-in-Charge.
thickness with bitumen of grade VG-
30 @ 5% (percentage by weight of
8 total mix) and lime filler @2%
(percentage by weight of Aggregate)
prepared in Batch Type Hot Mix Plant
of 100-120 TPH capacity.
Providing and laying Bituminous
concrete using crushed stone
aggregates of specified grading,
premixed with bituminous binder and
filler, transporting the hot mix to work
site by tippers, laying with paver
finisher equipped with electronic
sensor to the required grade, level
and alignment and rolling with
smooth wheeled, vibratory and
tandem rollers to achieve the desired
compaction and density as per
specification, complete and as per
directions of Engineer-in-Charge.
16.57.1 40/50 mm compacted thickness with cum 566.73 12126.2 6872281.33
bitumen of grade VG-30 @ 5.5%
(percentage by weight of total mix)
9 and lime filler @ 3% (percentage by
weight of Aggregate) prepared in
Batch Type Hot Mix Plant of 100-120
16.62 Providing and applying 2.5 mm thick Sqm 854 747.8 638621.2
road marking strips (retro- reflective)
of specified shade/ colour using hot
thermoplastic material by fully/ semi
automatic thermoplastic paint
applicator machine fitted with profile
shoe, glass beads dispenser, propane
tank heater and profile shoe heater,
driven by experienced operator on
road surface including cost of
material, labour, T&P, cleaning the
road surface of all dirt, seals, oil,
grease and foreign material etc.
complete as per direction of
Engineer-in-charge and accordance
with applicable specifications.
ECOR-CONST-HQ-ENGG/ECOR
Construction of granular sub-base by
providing close graded Material
conforming to specifications, mixing
in a mechanical mix plant at OMC,
carriage of mixed material by tippers
to work site, for all leads & lifts,
16.78 spreading in uniform layers of
specified thickness with motor grader
on prepared surface and compacting
with vibratory power roller to achieve
the desired density, complete as per
specifications and directions of
Engineer-in-Charge.
16.78.1 With material conforming to Grade-I cum 2095 2784 5832480
11 (size range 75 mm to 0.075 mm)
having CBR Value-30
16.79 Providing, laying, spreading and cum 3142.5 2914.3 9158187.75
compacting graded stone aggregate
(size range 53 mm to 0.075 mm ) to
wet mix macadam (WMM)
specification including premixing the
material with water at OMC in for all
leads & lifts, laying in uniform layers
12 with mechanical paver finisher in sub-
base / base course on well prepared
surface and compacting with
vibratory roller of 8 to 10 tonne
capacity to achieve the desired
density, complete as per
specifications and directions of
Engineer-in-Charge.
22.0 WATER PROOFING
22.1S General
22.22 Providing and mixing integral Kg 11550.51 388 4481597.88
crystalline admixture for water
proofing treatment to RCC structures
like basement raft, retaining walls,
reservoir, sewage & water treatment
plant, tunnels / subway and bridge
deck etc. at the time of transporting
of concrete into the drum of the
ready-mix truck , using integral
crystalline admixture @0.80%
(minimum) to the weight of cement
content per cubic meter of concrete)
or higher as recommended by the
manufacturer's specification in
reinforced cement concrete at site of
work. The material shall meet the
requirements as specified in ACI-212-
3R-2010 i.e. by reducing permeability
of concrete by more than 90%,
compared with control concrete as
per DIN 1048 and resistant to 16 bar
hydrostatic pressure. The crystalline
admixture shall be capable of self-
healing of cracks up to a width of
0.50 mm. The work shall be carried
out all complete as per specification
and the direction of the Engineer-in-
charge. The product performance
shall carry guarantee for 10 years
against any leakage.
26.0 NEW TECHNOLOGIES AND MATERIALS
26.1S General
ECOR-CONST-HQ-ENGG/ECOR
Providing at all heights, levels and
locations Aluminium profile industrial
troughed sheet of Alloy
31500/31000/40800, conforming to IS
1254, IS 737, IS 2676. The sheet shall
be fixed using self drilling/self tapping
SS screws of size 5.5x65 mm with
EPDM seal complete upto required
pitch in horizontal, vertical or curved
26.19 surfaces including cutting to size and
shape where required as per
specifications, detail drawings and
direction of Engineer-in-Charge. The
rate shall be inclusive of all screws,
seal, ridge, labour, scaffolding,
machinery for fixing and approved
sealant where required etc. but
excluding the cost of purlins, rafters
14 width 1044/920 mm, cover width
26.41S NEW TECHNOLOGY ITEMS
26.65 Providing and fixing roofing consist of Sqm 2647.2 1525.6 4038568.32
0.8 mm thick galvanized steel deck
sheet confirming to IS 277:1992 used
as permanent shuttering over which
MS wire mesh 3mm laid at 100x100
mm grid including edge trim covered
with concrete. This metal deck will be
supported on structural steel beam
with shear studs. (Structural steel like
Beam, column, joists etc. & concrete
of different grade as per design will
be paid separately).
Schedule Schedule G-Execution of Non Schedule items (Non USSOR-2021 & CPWD-DSR-2023 items).
Item- 7 Execution of all items as per Schedule-G.
S No. Item No Description of Item Unit Qty Rate Amount
0.2mm) thick heavy duty, full-body
homogeneous, anti-algal, all weather
resistant, exterior use Paving vitrified
tiles of size upto 400mmx400mm in
approved shade, colour & quality,
having anti-skid matt finish surface
with plain or projected texture. Tiles
to be laid on 20 mm average thick
cement mortar bed of 1:4 (1 cement :
4 coarse sand) with all labour,
material complete job.
carboxylate ether base water
reducing admixture Plast Super- C700
conforming to lS:9103-1999 (to be
added @ 1% by weight of cement) for
CC & RCC work for controling water
cement ratio and for gaining early
ECOR-CONST-HQ-ENGG/ECOR
3 3 Providing precast RCC slab for use as cum 68.48 8121.00 556126.08
shuttering slabs, foot path slab etc,
using M-30 design mix with 20 mm
graded stone aggregate including
fixing and removal of contractor's for
works ,shuttering supports, vibrating
,curing etc and fixing in position (all
labour and materials including
cement by the contractor) with all
lead and lift etc as per approved
drawing and as directed by the
Engineer-in-charge.
4 4 Providing two coats of elastic Sqm 10892.87 534.00 5816792.58
elastomeric membrane coating with
breathing property(viz., "Emce colour
Flex"/Deck guard 'S' or similar type
coating materials) over one coat with
its primer, the system should be
made of water based acrylic polymer
with selected mineral fillers having
properties of ultra violet resistant
crack bridging type, carbonation
resistant, water proofing coating, the
consumption of primary coat and two
coats of protective coating shall be as
per the manufacturers specification
should be in suitable approved
shades, including cost of materials,
cleaning chipping and removing the
dirt particles of the concrete with wire
brush and water, labour for applying
the above coatings, scaffolding
charges, all inclusive taxes etc for
sub structure and super structure of
the Road over Bridge. Dry film
thickness of each coating shall not be
less than 150 microns. Manufaturer
specifications shall be followed.
5 5 Fabricating, supplying & installing Kg 1560.00 993.89 1550468.40
stainless steel railings for staircases,
balconies, FOBs, Enquiry/Reservation
complex etc., made of SS 304 grade
stainless steel, laser cut / water jet
cut (no shearing), polished with
Automatic round/flat polishing
machine to get a uniform hairline
finish. All parts shall be connected to
each other with the help of
prescribed size CNC made solid
connectors, countersunk screws.
Welding should be finished ensuring
that no welding marks are visible and
assembly is mounted on floor with the
help of dash fasteners. Railings shall
be fabricated as per approved
drawings by engineer-in-charge.
Manufacturer shall submit aintenance
manual and basic material test report
for grade certification.
6 6 Painting of crash barrier/kerb stones Sqm 3766.30 149.00 561178.70
of CC/RCC slabs, stone with approved
quality reflective type of Enamel
paint , including one coat of primer
with contractor's own labour and
material etc. complete as directed by
Engineer -in -charge.
ECOR-CONST-HQ-ENGG/ECOR
7 7 Provision of an reinforced cement Metre 1000.00 783.15 783150.00
concrete crash barrier /RCC wall type
railing at edge of the road,
approaches to bridge structure and
medians, constructed with M-25
Grade concrete with HYSD
8 8 Conducting non destructive tests on Numbers 550.00 2795.00 1537250.00
butt and fillet welds as per IS codes
by Radiography/Ultrasonic, Magnetic
particle test report and dye
penetration tests by approved
agency and submitting the proper
test report to thedepartment duly
certification by the approved agency
with contractor, labor, materials,
tools and plants including leading,
loading and unloading etc complete
as directed by the Engineer-
incharge.R.T.Test (Film 300m long).
9 9 Conducting non destructive tests on Metre 5000.00 608.00 3040000.00
butt and fillet welds as per IS codes
by Radiography/Ultrasonic, Magnetic
particle test report and dye
penetration tests by approved
agency and submitting the proper
test report to the department duly
certification by the approved agency
with contractor, labor, materials,
tools and plants including leading,
loading and unloading etc complete
as directed by the Engineer-in-
charge.D.P.Test/ M.P.Test/U.T.Test.
10 10 Launching girders under traffic block. MT 926.64 12911.36 11964182.63
11 11 Supplying & fixing of bearing with Each 2.00 122121.26 244242.52
fixtures for 25T loading for composite
girders- welding type 18.3m/24.4m
and 30.5m span Metallic guided
bearing as per RDSO approved
drawings with latest amendment. The
rate is inclusive of supply of Metallic
guided bearings and all other
components of approved dimensions
and specifications based on RDSO
Drawings with latest amendment,
fixing in position on bed block true to
line and level on pier/ abutment. This
included testing charges from
reputed laboratories, inspection
charges, if any, fixing with any other
adhesive material to the satisfaction
of Engineer at site with all lead, lift,
labour etc. complete in all respect.
Note The bearing shall meet with the
requirement as mentioned in the
respective approved drawings.
ECOR-CONST-HQ-ENGG/ECOR
12 12 Providing and laying well graded cum 1640.00 2533.45 4154858.00
drainage fill by 450 mm thick
composed of 20mm, 10mm, and
6mm of well graded aggregate as per
drawing and technical specification
and including cost, seignorage and
conveyence Of all the material to site
and all labour charge, drain pipe
wrapped With geotextile, hire charges
of plant and machinery for laying
filter Media, incluiding technical
supervision as directed by engineer-
in-charge for finished item of work for
drainage layers behind the facts. As
per approved reinforced soil wall
earth(RE) walls with good gravel
(Angle of interna friction not less than
32) depositing the gravel between
walls, spreading gravel, sectioning,
grading and consolidatlon with 8 to
10 Tonnes vibratory road Roller @
OMC and with plate compactor/small
vibrator for 1.5 m width from facia to
meet requirement of table 300-2 of
MORTH, including all hire and
operational charges of T&P and
seigniorage charges, complete for
finished item of work as per MoRT&H
specification 305 & 2200 (5th
Revision) (Payment will be made
based on level for finished Item of
work) as per approved drawing and
as per the directions of the Engineer-
14 14 Providing Reinforced earth structure Sqm 4920.00 9848.09 48452602.80
including excavation for foundation,
foundation concrete in M15 and
cement concrete grooved seating in
the foundation for facing elements
inM35 (facia material) and its
placement, assembling, joining with
facing elements and layingof the
reinforcing elements asper Clause
3103, fixing frictionties and anchor
pins etc. as per approved design and
drawing, providing filter media of
minimum 300 mm width or more
behind wall with perforated drainage
pipe of required diameter both
longitudinal and transverse direction
as directed, back filling with
approved granular selected material ,
laying in layers of 150mm thick,
breaking clods, dressing in required
lines, grades& section, watering and
compaction by vibratory roller etc.
including all lifts (for 5 Km lead &
average height of 8 m)complete. Note
: Back filling of approved granular
material of1500mm width to be
ECOR-CONST-HQ-ENGG/ECOR
15 15 Supplying, cutting and fixing 18 mm Sqm 150.00 1203.00 180450.00
thick mastic pads for clean
joints/expansion joints in between
slab etc. as per IS: 1838 specification
inclusive of costs of labour, materials,
tools and equipment, loading,
unloading, all lead and lift, including
crossing of railway track, taxes,
royalty and all other incidental
charges etc., complete as diretced by
Engineer-In-charge (cut pieces less
than 500 mm should not be used).
16 16 Providing Speed breakers as per Each 2.00 2953.00 5906.00
Railways approved Plans/Drawings
including painting white and yellow
bands, diagonals etc., complete with
contractors labour men and
materials, machinery, consumables,
approved paint, T&P, Crew, fuel etc.,
complete inlcuidng all lead and lifts
and directed by egineer-In -Charge.
17 17 Supply, fabrication, painting and Each 15.00 4429.00 66435.00
erection of road traffic warning
boards of suitable height of various
purposes such as No parking, No
entry , HTV and prohibited etc as per
IRC standards made of 50 * 50 * 5
mm MS angles such and 3 mm thick
MS plate for the board of appropriate
enamel paint and pasted with
reflective stickers reflective paint on
the board erected into the ground
with cement concrete 1:3:6 for 0.30 *
0.30 * 0.60 metre including earth
work excavation, etc as directed by
the Engineer-in-Charge.
18 18 Supplying & fixing G.I. lamp posts in Each 10.00 10290.00 102900.00
crash barriers of ROB. The Post shall
consist of G.I. Pipe 100 mm dia 3m
long reduced to 75 mm dia 2.5m long
and again reduced to 50 mm dia 2.5
m vertical height including fixing of
G.I. reducers and welding of G.I.
Pipes, bending ,transportation, all
taxes ,lead, lift etc. Necessary
provision for Electrical concealed
wiring shall be made in the parapets
and lamp posts complete as require.
Rate is also inclusive of fixing of
contractors junction boxes in crash
19 19 supplying and fixing approved quality Sqm 100.00 3663.00 366300.00
of poly carbonate sheets 2mm thick
in side walling to suit the required
profile embossed clear translucent UV
protected with all fittings such as J
bolts bitumen and cup washers,
including drilling holes in sheets,
filling the gaps with Sqm silicon
sealant including all cost of labour
materials, lead, lift, transportation,
loading, unloading, etc. Complete as
directed by Engineer-in- charge.
Note: The area of individual sheets
will be taken into consideration for
ECOR-CONST-HQ-ENGG/ECOR
20 20 Comprehensive Land Acquisition Each 1.00 631880.00 631880.00
Liaison Services under Railways Bridge
(Amendment) Act, 2008 including Site
office with all category of Man power
(Land expert, Amin, Legal expert,
Chainman etc.), Camp for public
consultation, boundary making and
fixing of stone with supervision
charges involving below activities:
NOTE: 1. PRE-ACQUISITION
ACTIVITIES (Sections 20-A to 20-D)
1.1 Land Survey and Verification
(Section 20-A Support) 1.2
Stakeholder Consultation and
Documentation 1.3 Survey
Operations Support (Section 20-B) 1.4
Damage Assessment and
Compensation (Section 20-C) 1.5
Objection Management (Section 20-
D) 2. DECLARATION PROCESS
(Section 20-E) 2.1 Declaration
Documentation 2.2 Publication and
Notification 3. COMPENSATION AND
ACQUISITION (Sections 20-F to 20-I)
3.1 Valuation and Compensation
(Sections 20-F & 20-G) 3.2 CALA and
Arbitration Support 3.3 Payment and
Possession (Sections 20-H & 20-I) 4.
POST-ACQUISITION ACTIVITIES 4.1
Land Transfer and Mutation 4.2 Final
Demarcation and Handover 4.3
Compliance and Reporting 4.4 Fixing
of Boundary stone Payment Schedule:
i) 40% of the accepted rate will be
made after complting Section -11/20A
to 20-D. ii) 20% will be released on
clearing Section - 20-E (iii) 20% on
clearing Section - 20-F (iv) 20% in the
Final bill after completing all land
acquisition work, including mutations
of land to the name of the Railway.
21 21 Supplying & fixing of bearing with Each 2.00 154046.49 308092.98
fixtures for 25T loading for composite
girders- welding type 18.3m/24.4m
and 30.5m span Metallic guided
bearing as per RDSO approved
drawings with latest amendment. The
rate is inclusive of supply of Metallic
guided bearings and all other
components of approved dimensions
and specifications based on RDSO
Drawings with latest amendment,
fixing in position on bed block true to
line and level on pier/ abutment. This
included testing charges from
reputed laboratories, inspection
charges, if any, fixing with any other
adhesive material to the satisfaction
of Engineer at site with all lead, lift,
labour etc. complete in all respect.
Note The bearing shall meet with the
requirement as mentioned in the
respective approved drawings.
(45.7m - 30.5m Span)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexedDocument469ROB.pdf
SpecialconditionofROB469.pdf