Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAdmitted-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Admitted-Finance | |
| 2 | L2₹4.2 L+₹76,350 (22.3%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹5.4 L+₹2.0 L (57.6%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹6.3 L+₹2.8 L (83.0%)Admitted-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Admitted-Finance | |
| 5 | L5₹6.4 L+₹3.0 L (86.2%)Admitted-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L5 | Kakolil Trade Agencies L1 | OPS Associates L2 | SKV Engineering L4 | M/S SINGHAL ENGINEERS L3 | R DHARMALINGAM L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing, testing and commissioning of Retrofit emission control devices (RECD) for Existing 62.5 KVA DG Set for reducing emission as per CPCB guidelines including fixing frame with material and connected accessories for installation of RECD at DG Set Canopy installed at at Power house (Make-Kirloskar) Complete all as specified and as directed by the Engr-in-Charge.The exhaust limits of DG set Post fitment of RECD are as follows.
i) NOx+HC<4.7, ii) CO <3.5, iii) PM(Particulate Matter) < 0.3, iv) Smoke limit(Light absorption Coefficient, m-1) < 0.7
Technical Specifications:
a) Type of Emission device (Working principle of the PM reduction active element): Electrostatic Percipition (ESP), b) Polllutant captured: PM 2.5, c) Capturing efficieny: At least 70%, d) Back Pressure on engine: No Back pressure (Should be less than 100 mmwc), e) By product: Carbon Particles in dry form, f) By product disposals cope: Should be in vender scope Material of construction (Outer Body): Mild Steel Powder Coated. g) Material of construction (Inner Cells): SS-304. Testing, h) Requirements post manufacturing: ISO-81785 mode cycle for DG set up to 800 KW as per CPCB guidelines. Testing
i) Requirements post installation at site: Emission monitoring from stack will be done from any NABL approved lab.
j) Product Life: 10-15 Years
Note: i)Taking down of Existing Exhaust pipe and Suuply and fixing of New Extension Silencer pipe upto 4 mtr with asbestos rope and Insulation on emission devices: Glass wool Including Device installation fabrication work and transporation to site and any civil work, is to be included in the quoted rate by contractor.
ii) The Contractor shall submit test report certificate of RECD device as per CPCB latest Compliance
Make: Kirloskar, Cummins, Greaves suitable for existing Kirloskar make DG set | 1 | Each Job | 6,00,000 ₹6,00,000 | 2,56,650 ₹2,56,650 Lowest | 2,69,500 ₹2,69,500 | 4,75,000 ₹4,75,000 | 3,60,000 ₹3,60,000 | 7,30,000 ₹7,30,000 |
| 2.00 | Supply, installing, testing and commissioning of MS body fabricated Diesel Storage Tank of Capacity 1000 Ltrs , Leak proof, Corrosion Resistant having 10% free board for safety expansion painted with one coat of red oxide primer and two coats of synthetic enamel paint of Grey colour of square/rectangular shape with suitable dimensions as fiited in existing power house with PVC transparent Hose pipe fix vertically from top to bootom for Fuel level indication with scale in Ltrs, MS pipe dia 10-15mm fuel connection piping work from bottom of tank to existing 62.5 KVA DG set fuel tank with cut off valve and Fuel tank Drain valve for cleaning purpose including Provision of MS channel stand size 50x50x6mm of approx height 1.2 Mtr with PCC foundation complete all as specified and directed by the Engr-in-Charge. | 1 | Each Job | 38,000 ₹38,000 Lowest | 86,000 ₹86,000 | 1,49,500 ₹1,49,500 | 1,52,000 ₹1,52,000 | 1,80,000 ₹1,80,000 | 90,000 ₹90,000 |
Tender Value
₹5.8 L
EMD Value
₹11,600
Closing Date
30 Jun 2026, 6:00 pmClosed
AGE (I) Central, Sri Vijaya Puram
AGE (I) Central, Sri Vijaya Puram
PROVISION OF RETROFIT EMISSION CONTROL DEVICE (RECD) FOR 62.5 KVA DG SET AT SHAHEED DWEEP UNDER AGE (I) CENTRAL, SRI VIJAYA PURAM
2026_MES_769068_1
8140/E8
Open Tender
Civil Works - Others
Item Rate
120 days
Shaheed Dweep
As per NIT
9 documents required · 9 mandatory
₹500
AGE (I) Central, Sri Vijaya Puram
₹11,600
Yes
31 Jul 2026
1 Jun 2026
2 Jul 2026
1 Jun 2026
30 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installing, testing and commissioning of Retrofit emission control devices (RECD) for Existing 62.5 KVA DG Set for reducing emission as per CPCB guidelines including fixing frame with material and connected accessories for installation of RECD at DG Set Canopy installed at at Power house (Make-Kirloskar) Complete all as specified and as directed by the Engr-in-Charge.The exhaust limits of DG set Post fitment of RECD are as follows.
i) NOx+HC<4.7, ii) CO <3.5, iii) PM(Particulate Matter) < 0.3, iv) Smoke limit(Light absorption Coefficient, m-1) < 0.7
Technical Specifications:
a) Type of Emission device (Working principle of the PM reduction active element): Electrostatic Percipition (ESP), b) Polllutant captured: PM 2.5, c) Capturing efficieny: At least 70%, d) Back Pressure on engine: No Back pressure (Should be less than 100 mmwc), e) By product: Carbon Particles in dry form, f) By product disposals cope: Should be in vender scope Material of construction (Outer Body): Mild Steel Powder Coated. g) Material of construction (Inner Cells): SS-304. Testing, h) Requirements post manufacturing: ISO-81785 mode cycle for DG set up to 800 KW as per CPCB guidelines. Testing
i) Requirements post installation at site: Emission monitoring from stack will be done from any NABL approved lab.
j) Product Life: 10-15 Years
Note: i)Taking down of Existing Exhaust pipe and Suuply and fixing of New Extension Silencer pipe upto 4 mtr with asbestos rope and Insulation on emission devices: Glass wool Including Device installation fabrication work and transporation to site and any civil work, is to be included in the quoted rate by contractor.
ii) The Contractor shall submit test report certificate of RECD device as per CPCB latest Compliance
Make: Kirloskar, Cummins, Greaves suitable for existing Kirloskar make DG set | 1 | Each Job | - | - |
| 2 | Supply, installing, testing and commissioning of MS body fabricated Diesel Storage Tank of Capacity 1000 Ltrs , Leak proof, Corrosion Resistant having 10% free board for safety expansion painted with one coat of red oxide primer and two coats of synthetic enamel paint of Grey colour of square/rectangular shape with suitable dimensions as fiited in existing power house with PVC transparent Hose pipe fix vertically from top to bootom for Fuel level indication with scale in Ltrs, MS pipe dia 10-15mm fuel connection piping work from bottom of tank to existing 62.5 KVA DG set fuel tank with cut off valve and Fuel tank Drain valve for cleaning purpose including Provision of MS channel stand size 50x50x6mm of approx height 1.2 Mtr with PCC foundation complete all as specified and directed by the Engr-in-Charge. | 1 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
8140docs.pdf
Tender Documents • 1.06 MB
BOQ_861266.xls
BOQ • 5.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .