Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
14 Dec 2021, 6:00 pmClosed
SE
EDC KANPUR
33 KV LINE SHIFTING WORK ON TURN KEY BASIS.
2021_DVVNL_651455_1
141/2021-22
Open Tender
Electrical Works
Turn-key
45 days
KANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EDC KANPUR
₹86,000
28 Dec 2021
4 Dec 2021
15 Dec 2021
4 Dec 2021
14 Dec 2021
4 Dec 2021
11 KV Work
Supply and Errection of ST POLE 11 mtr. ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of P.C.C. 09 mtr. ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Stone Paid 300 X 300 mm( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Top Channel 125 X 65 MM with clamp ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of M.S. Bracing Angle 65 X 65 X 6 mm, with clamp ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Disc. Insulator B&S Type 7000 KG.( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Disc Fitting B&S Type 70 KN( As Per Norms of UPPCL/DVVNL)
Supply and Errection of 33 KV pin Insulator( As Per Norms of UPPCL/DVVNL)
Supply and Errection of 33 KV G.I. Pin with Nut & Bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Earth wire clamp with Nut & Bolt( As Per Norms of UPPCL/DVVNL)
Supply and Errection of P.G. Clamp Dog to Dog ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of E Clamp for 33 KV with Nut & Bolt( As Per Norms of UPPCL/DVVNL)
Supply and Errection of No Plate ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Danger board with clam for 33 KV( As Per Norms of UPPCL/DVVNL)
Supply and Errection ofAlu minium Winding Wire-6 SWG ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of All. Paint( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Red - Oxide Paint( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Barbed Wire ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Bolt Nut & Washer ( As Per Norms of UPPCL/DVVNL)
Supply and Errection ofStay (Stay rod 16Xl800mm. Stay wire 5 Kg, Stay Clamp, Bolt & Nut with Grouting)( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Earthing Complete ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of V-type X-Arm for 33 KV ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of MS Channel Piece 100x50x6 mm 350mm & 250 mm Long with clamp , Nut & Bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of PP clamp for 11 Mtr STP with nut & bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of F-clamp with nut & bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of X-Arm Holding Clamp with nut&bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of M.S. Angel 65x65x6mm long for Dropper( As Per Norms of UPPCL/DVVNL)
Supply and Errection of M.S. Angel 75x75x6mm long ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of G.I. wire 6swg ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of G.I. wire 10swg ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Eye Bolt ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Turn Buckle ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of PP & Clamp for 11 Mtr STP with bolt & nut( As Per Norms of UPPCL/DVVNL)
Supply and Errection of 33 KV 3X300 SqMM X.L.P.E. Cable ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of ACSR DOG Conductor ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Cable Box out door jointing Kit for 33 KV 3x300 SqMM X.L.P.E. Cable ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of Clamp for fixing cable on channel of double pole ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of M.S. Angel for Dropper 65X65X6 mm ( As Per Norms of UPPCL/DVVNL)
Supply and Errection of G.I. Pipe 6" Dia ( As Per Norms of UPPCL/DVVNL)
Supply & Laying of H.D.P.E. Pipe 6" Dia by HDD Method( As Per Norms of UPPCL/DVVNL)
Concreting of Pole ( As Per Norms of UPPCL/DVVNL)
Laying of 33 KV 3x300SqMM Cable through HDPE pipe by HDD Method.( As Per Norms of UPPCL/DVVNL)
Laying of 33 KV 3x300SqMM Cable through Trench including digging of trenches and filling earth , Dressing &Ramming and laying cable with sand & bricks arrangement .( As Per Norms of UPPCL/DVVNL)
Laying of 33 KV 3x300SqMM Cable through G.I. Pipe on double pole , mounting on poles with proper clamping .( As Per Norms of UPPCL/DVVNL)
Dismantling of all accesseries from 11 Mtr single pole like X-Arm , insulator , GI pin, clamps etc. Digging out 11 mtr STP pole safely after breaking grouting of pole and stacking at nearest store encluding carriage.
Dismantling of old and used ACSR Dog conductor encluding oppening of binding , removal of gun fittings from Double poles, making rolls and safe carriage to local store .
Dismantling of all accesseries from 09 Mtr Single /Double / Four PCC pole like X-Arm , insulator , GI pin, clamps etc. Digging out 09 Mtr PCC pole safely after breaking grouting of pole and stacking at nearest store encluding carriage.
Dismantling of old and used 33 KV 3x300SqMM X.L.P.E. Cable encluding oppening of binding , removal from Double poles, making rolls and safe carriage to local store .
AMIT ENGINEERING CORPORATION
HARVITEC ENTERPRISES PVT LTD
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .