Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 Nov 2023, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair / Maintenance of LT over head line, LT underground cable and connected items in ILP and Birdhwal under GE (A) Suratgarh at Suratgarh Mil Stn
2023_MES_622616_1
GE (A) SOG - Token No 60/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
SURATGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE ARMY SURATGARH
₹90,000
Yes
11 Dec 2023
10 Oct 2023
8 Nov 2023
10 Oct 2023
6 Nov 2023
24 Oct 2023
Amount
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Dismantling existing unserviceable continuous GI earth wire / guard / cradles of any size complete all as specified and as directed by Engineer-in-charge.
Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified. Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge. (ii) Length of each conductor shall be measured as one length.
S&F GI wire including stretching on LT poles as contineous earth wire or for guarding and cradles including binding as required complete all as specified and directed by Engineer-in-Charge. Note: -(i) For payment purpose, weight of galvanised wire shall only be considered. Clamps, eye hooks where provided shall be measured and paid for separately
Supplying, fixing & stretching aluminium conductor steel, reinforced (ACSR) of any size fixed on LT poles fixed on insulators and binding with & including 2 mm binding wire complete all as specified and directed by Engineer-in-Charge. Notes: - (i) The ACSR conductors shall be conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also be deemed to include for supply and fixing of binding wire, aluminum tapes etc. which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size multiplied by length of span and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.
S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement pin type insulator of size 100mm height, 65 mm dia porcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
Inspection/Checking of street light fitting 30/45/60/72/90 watt LED light fittings etc for tighting the connection with replacement of twin core multi stranded 1.5 sqmm aluminium wire complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Ladder wheel shall be arranged by the Contractor. (ii) The cost of wire replaced will not be paid seprately in over head conductors.
Taking down street light fitting upto 30/45/60/72/90 watt LED light fittings etc for finding faults including cleaning glass with castic soda solution and refixing the same in existing position after carrying out necessary repair / replacement of unserviceable parts complete all as specified and directed by Engineer-in-Charge. Notes :- (i) The accessories / spare parts which are required to be replaced shall be measured and paid for separately as “Supply only”. (ii) Ladder wheel shall be arranged by the Contractor. (iii) Detection and rectification of fault in over head/under ground line shall be done by the contractor.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 45 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement electronic driver 220/240 volts suitable for existing LED Street light fitting 60 watts complete all as specified and directed by Engineer-in-Charge. Make :- Wipro / Philips / Syska / Crompton / Surya or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement 10 KV surge protector suitable for LED fittings 45 / 60 / 72 / 90 watts complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat part No SRPSQ-10KV/5KA-440 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only weather proof PVC insulated, sheathed three core stranded aluminium conductor cable of size 2.5 Sqmm, 1100 Volts grade conforming to IS:9968 (Part-I) 1988 or IS:694-1990 complete all as specified and directed by Engineer-in-Charge.
S&F in repair street light bracket made out of 32mm dia GI pipe light grade 1.2m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Disconecting and taking down existing unservicable unserviceable street light fittings of any type and make along with accessories as directed by Engineer-in-charge. Notes:- (i) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
Fixing only street light fitting after repair and replacement of required spare parts installed with same or other location including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Note :- Street light retrieved vide item No 15 here-in-before shall be used under this item.
Supply, fixing and testing LED Street / Security light fitting of 45 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge.
All as per Srl item No 17 above but LED street / security light of 60 watt Notes for srl Item No 17 & 18 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
S&F in replacement cable junction box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Make :- Syntex / Hensal / Indokop Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
Inspection/checking of APFC panel 3 phase, 440 voltage 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel to make it serviceable with the help of connecting relays, capacitors, contactors, MCB's, CT's etc and rectifying the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid for separately under respective items of BOQ as supply only..
Supply only in replacement of AIPFC micro processor based relay 4 Stage PFC CONTROLLER-BR-4904-04 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of AIPFC micro processor based relay 8 Stage PFC CONTROLLER-BR-4000-08 ST RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of AIPFC micro processor based relay 12 Stage BR6000 SERIES 12 STP RELAY 230V complete all as specified and as directed by Engineer in charge.. Make - L & T /GE / EPCOS / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 1 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32447A4012B 40 / GE/L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 3 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4032B 40 / GE/L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 5 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4052B 40 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 10 KVAR complete all as specified and as directed by Engineer in charge. Make - Epcos Cat part- B32448A4102B 40 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 12.5 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part-B32448A4122B540 / GE / L& T / Siemens / Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Heavy duty Capacitor 3 Phase, 415Volt (AC), 50 HZ of cap 15 KVAR complete all as specified and as directed by Engineer in charge.. Make - Epcos Cat part- B32448A4122B540 / GE / L& T / Siemens /Crompton or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 10 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S1011C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 16 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge. Make - EPCOS Cat Part No B44066S1611C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Supply only in replacement of Capacitor duty contactors 3 Phase suitable up to 25 KVAR cap Duty cont 1 NO1NC240V complete all as specified and as directed by Engineer in charge.. Make - EPCOS Cat Part No B44066S2511C240N 1 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in repair of MCB 32 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge..
S&F in repair of MCB 40 Amps, 3 pole, C curve, 10 KA complete all as specified and as directed by Engineer in charge..
S&F in replacement MCB 63 Amps, Single Pole & neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
Supply only in replacement of current transformer of ratio 100/5, 5 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy class 1.0 including connection with 2.5 sqmm twin core PVC cable complete all as specified and as directed by Engineer in charge.
S&F in replacement pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
Disconnecting over head conductors and insulators any Nos on existing damaged steel tubular swaged LT poles, dismantling MS work such as cross arms /clamps/hooks etc, stay and street light (where exists), excavating and taking out damaged pole making good hole to receive new pole and S&F in same position new steel tubular swaged pole 09 meter long type 410 SP-31, re-fixing the MS work cross arms/clamps/hooks etc and insulators retrieved from dismantling and re-jointing the conductors with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying two coats of aluminium paint to remaining portion of pole, over cross arms, brackets, bracings, clamps, hooks etc and marking pole number complete all as specified and as directed by Engineer-in-charge.
M&L for painting on steel tubular poles 9 metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint in black and yellow colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying two coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with white synthetic enamel paint in 80mm high letters, over black synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge. Note :- Pole number shall be marked with white enamel paint over a base of size 20cm x 20cm prepared with two coats of black enamel paint on pole surfaces.
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles, filling & mass concrete including necessary form work complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
Suppyling, installing, testing and commissioning of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 45 Incoming (a) 300 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 200 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 06 Nos (b) Digital voltmeter and ampere meter flush type 96x96 mm including CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
All as per item No 45 above but comprising of following accessories :- Incoming (a) 250 Amps aluminium bus bar including Neutral and three phase - 01 Set (b) MCCB 160 Amps, 36 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 01 No Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, 415 Volts, thermal Magnetic release type - 04 No (b) Digital Voltmeter and Ampere meter flush type 96x96mm inlcuding CTs suitable size - Each Seprately (c) Internal all links & control cable and indicators - set of three
Suppyling, installing, testing and commissioning of factory made outdoor type bus bar chamber having MCCB 160 Amps, 4 pole, 415 volts, 3 phase, 4 wire, 50 Hz, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 200 Amps aluminium bus bar fixed horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators duly connected with 160 Amps MCCB including provision for taking out incoming and outgoing cable detacheable plate at bottom for cable entry and making six Nos hole in each bus bar including with bottom frame made out of angle iron 50mm x 50mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer-in-Charge. Note :- (i) Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account. (ii) All cables to be connected with busbar will be properly thimbles.
All as per item No 47 above but MCCB 100 Amps, 4 pole, 415 volts and 160 Amps aluminium bus bar
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge. Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
Laying, jointing, commissioning and testing in replacement XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 185 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions. (iii) Cable required for laying shall be issued under Schedule 'B' free for fixing only.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 51 above but cable of cross sectional area 120 sq mm 3.5 core
All as per item No 51 above but cable of cross sectional area 95 sq mm 3.5 core
All as per item No 51 above but cable of cross sectional area 70 sq mm 3.5 core
All as per item No 51 above but cable of cross sectional area 50 sq mm 3.5 core
All as per item No 51 above but cable of cross sectional area 35 sq mm 3.5 core
Supplying, laying, jointing, comissioning and testing of PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm 4 core confirming to IS : 1554 (Part-I 1988) laid in tenches along polesthrough pipe etc including taking down old unserviceable cable complete all as specified & as directed by Engineer –in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 57 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 57 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 57 above but cable of cross sectional area 10 sq mm 2 core
Supplying, jointing and testing heat shrinkable type straight through jointing kit, suitable for cable of size 16 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 61 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 61 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 61 above but suitable for cable of size 240 sqmm to 300 sqmm.
Supplying, jointing and testing heat shrinkable type, in / out door, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
All as per item No 65 above but suitable for cable of size 70 sqmm to 120 sqmm.
All as per item No 65 above but suitable for cable of size 150 sqmm to 185 sqmm.
All as per item No 65 above but suitable for cable of size 240 sqmm to 300 sqmm.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre) Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
Taking out old unserviceable underground LT Cable with standad aluminium conductor 1100 volts grade cross sectional area upto 10 sqmm 2 core to 95 Sqmm 3.5 core form trenches / floor / road / pipe / along poles and relaying in the same location after repair complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork, sand cushioning, cable cover, cable protection & GI Pipe shall be measured and paid seperately under respective items of BOQ.
All as per item No 70 above but cable of cross sectional area 120 sqmm to 300 sqmm
S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 16 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge. Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 74 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F in replacement Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account.
All as per item No 80 above but 80mm bore tubing
All as per item No 80 above but 50mm bore tubing
All as per item No 80 above but 40mm bore tubing
M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box (indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCCB 4 Pole 63 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
All as per item No. 85 here-in-before but MCCB 4 Pole, 100 Amps rating, breaking capacity 25 KA, 415 Volt
All as per item No. 85 here-in-before but MCCB 4 Pole, 125 Amps rating, breaking capacity 25 KA, 415 Volt
All as per item No. 85 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 36 KA, 415 Volt
All as per item No. 85 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 36 KA, 415 Volt
All as per item No. 85 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt
All as per item No. 85 here-in-before but MCCB 4 Pole, 630 Amps rating, breaking capacity 50 KA, 415 Volt
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 640mm, width 25mm, thickness 12mm, suitable for 3-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 940mm, width 25mm, thickness 12mm, suitable for 4-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F LT Line polypropylene composite phase separator, moulded or bolted type, overall length 1250mm, width 25mm, thickness 12mm, suitable for 5-lines wire complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MCB, four Pole 63 Amps, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge.
S&F in replacement air termination, single pointed aluminium rod 12 mm dia single pointed 300 mm long complete all as specified and directed by Engineer -in-Charge.
S&F in replacement galvanized iron strip of size 32 mm x6mm to be used as down conductor for lighting protection and to arrange ring main circuit for earth pit complete all as specified and directed by Engineer -in-Charge.
S&F in replacement Digital type Voltmeter 96mm x 96mm, of range 0-500 volts, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Digital type Ammeter 96mm x 96 mm of range 0-200 Amp, single phase, class -1 complete all as specified & as directed by Engineer-in-charge
S&F in replacement Phase indicator lamp assembly LED type complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
Supply only 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
Supply only 250mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in-Charge.
S&F in replacement heavy duty TPN bus bar chamber 100 Amps, 4 way fixed with hinges and locking arrangements, wall mounting type and arrangements for 4 Nos incoming / outgoing connections in each bus bar fixed on wall complete all as specified & directed by Engineer-in-Charge.
M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening / correcting the distorted parts, cuttings, welding / riveting, drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Supply only butt hinges and sliding door bolts shall be measured and paid seperately under respective items of BOQ.
Taking down unservicbable ACB of capacity 630/800 Amps from the LT panel and disconnecting the same for repair/replacement following parts:- (a) Decarbonizing of busbar and all defective parts - 01 Job (b) Replacement of control wiring - 01 Job (c) Replacement of heat shrinkable insulation of busbar with colour coding - 01 Job (d) Replacement of Male / Female contactor (e) Toggle switch (f) Repairing to triping mechanism including replacement of all defective parts - 01 Job After repair reassebling / refixing the same in the LT panel and testing the same for proper working complete all as specified and as directed by Engineer-in-charge. Note :- All necessary spare parts shall be provided by the contractor. Nothing extra shall be paid on this account.
S&F as in repair of ACB 4 pole, 415 volts, 2500 Amps, 50 KA electrical draw out type and motor mechanism & closing coil with microprocessor relay comprising with earth fault, over load and short circuit complete all as specified and as directed by Engineer in charge.
Taking out bricks in trenches of cable protection cover complete all as specified and as directed by Engineer in charge. Note :- Excavation shall be measured and paid seprately in respective item.
M & L for relaying of old serviceable bricks retrieved vide item No 108 of for cable protection of underground cable complete all as specified and directed by Engineer-in-Charge. ---------------------------------------------------------------------------- Note :- A sum of Rs. 376418/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 26 (R) & 27 (R) (Schedule of Credit) of Tender documents.
M/s Rohit Construction Co.
B.K. ROY & SONS
Gupta Suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .