Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 |
Tender Value
₹11.9 L
EMD Value
₹23,764
Closing Date
12 Dec 2023, 12:00 pmClosed
Executive Engineer
Executive Engineer, Water Supply and Sanitation Division, Kapurthala. Water Works site at village Dhaliwal Dona, Kapurthala
Providing and Construction of 1 No. Storage facility for Storing Sodium Hypochlorite (Disinfectant) in Village Wadala Khurd Block and Distt. Kapurthala (Under JJM/State Share)
2023_WSS_112094_1
2023-24/Re-Recall Sodium Hypochloride
Open Tender
Civil Works
Item Rate
90 days
In village Wadala Khurd
Please refer Tender documents.
3 documents required · 3 mandatory
₹100
₹23,764
29 Jan 2024
6 Nov 2023
12 Dec 2023
6 Nov 2023
12 Dec 2023
6 Nov 2023
Amount
Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.
Dressing of earth work :-
New work or remodeling work.
Earth filling:- Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 metres
Cement concrete 1:6:12 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position.
For roof trusses, well curbs, plates and trussed girders, etc. of any span for buildings and bridges up to 15 m span.And also including 4 Nos. MS poles of 100 mm Dia. Height upto Roof Truss
Providing and Fixing fibre sheet including nut bolts, etc.
Providing and Fixing Storage tank of 10000 ltr. capacity, supporting saddle including carriage, installation of accessories etc. Which should be corrosion proof & compitable for storage of sodium hypochloride solution
Providing and Fixing safety shower including accessories etc.
Providing evaporation tank of size 0.6m x 0.6m at base and 1.8m x 1.8m at GL with 10mm thick acid or alkaline resistant tiles
Providing and fixing 10mm thick acid and/or alkali resistant tiles 300 mm x 300 mm of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS : 4457 complete as per the direction of Engineer-in- Charge, in flooring or in dado / skirting on a bed of 12 mm thick mortar 1 : 4 (1 acid proof cement: 4 coarse sand).
Conglomerate floor 50mm thick cement concrete ratio 1:2:4 on 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing for material.
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
Wiring light point in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mm complete in all respect.
C.I Fire Hydrants Stand Post Type IS-908
Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
Providing and fixing Flow meter of size 50 mm complete
Providing and fixing Level Gauge for Tank complete
Providing and fixing Precaution Boards Flex complete
Providing & fixing MS gate including gate pillar, corner pillar, CC pole & barbed wire complete in all respects.
Providing Ramp and earth filling inside in Sodium hypochlorite plant complete in all respects.
Supply & erection of LED Street Light 45 watt with pressure die cast aluminium housing with control gear (with IP65/IP66 protection) toughened glass fitting surge protection 10KV and efficacy of LED texture minimum 100 lumens per watt complete in all repects as approved and desired by the engineer in-charge at site LED Fitting as per circular issued by Hon. Tech. Adviser to CM punjab Letter no. ATPB/20/GI Dated 30/11/2017. Make Havell ENDURAPEARLNEOEL45WLED757SASYTOPC / Wipro LR02-501-XXX-57-GI / Jaguar LSTO1S045XC / CROMPTION LSTP-45CDL.
GI PIPE POLES & BRACKETS: SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:
Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-
Single Arm Bracket 1.5 metre Long for Steel Tubular Pole (7 to 8m)
Carriage of Material such as bajri and sand lead at site complete in all respect
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .