Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC C 89 CECC VILL POST PATHOLI AGRA UP | AGRA | AGRA | UTTAR PRADESH | 283105 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.0 L+₹1.6 L (7.15%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹24.7 L+₹2.3 L (10.4%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹24.9 L+₹2.5 L (11.2%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹26.2 L+₹3.9 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹34.9 L
EMD Value
₹69,840
Closing Date
11 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
SPECIAL REPAIR TO BLDG NO P 17, OR GOVT MD ACCN OF 29 PARA AT MP LINE UNDER GE EAST AGRA
2021_MES_489153_1
9396/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹69,840
Yes
28 Dec 2021
18 Nov 2021
21 Dec 2021
18 Nov 2021
11 Dec 2021
2 Dec 2021
60 days
Amount
Demolition of brick work or stone/boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking down cement or cemant lime plaster of any discription on bricks or stone walls/ceiling etc including racking out joints, hacking for kay, scrubbing down with water complete all as specified and directed.
M&L for rendering 10mm thick in two coats each 5 mm thick plastering on concrete surfaces of ceiling in CM 1:3, finished the surface even & smooth complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:6 on brick surfaces of walls & finishing the surface even & smooth complete all as specified and directed.
M&L for 15mm thick plastering in CM 1:4 with and including WPC on brick surfaces of walls & finishing the surface even & smooth complete all as specified and directed.
M&L for 20 mm thick cement plaster (on roof projection, chajja's, ceiling etc.) in CM(1:3) in two coat each 10 mm thick finished even and smooth without using extra cement complete all as specified and directed.
M&L GI Wire nettimg 0.90mm dia and 12 mm mesh lathing to wood or metal studding, joints, etc. sandwitched between two layers of plastering (Plastering shall be measured and paid separately) in walls, ceiling, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of average 2mm thick Birla putty on new plastered surfaces including preparation of surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of wall including cornices, pilaster etc by brooming down by steel wire brushing, scrapping down smoke Soot, moulds, moss and trading oil and greasy spots etc and apply one coat of white wash complete as specified and directed.
Material and Labour for preparation of old plastered or unplastered surfaces of ceiling and apply one coat of white wash complete as specified and directed.
M&L Preparing old plastered or unplastered surfaces of walls and applying two coats of oil bound distamper over a coat of average 2mm thick Birla putty complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
Material and Labour preparation of old painted wood & wood based surfaces of any description over 10 cm width or girth and apply one coat of synthetic enamel paint wood or tinted complete as specified and directed.
Material and Labour preparation of old painted steel surfaces of any description over 10 cm width or girth and apply one coat of synthetic enamel paint wood or tinted complete as specified and directed.
S&F in repair stainless steel plate rack of size 31"x30"x10" mm fixed to wall complete all as specified and as directed.
S&F in repair kitchen sink with draining board made of stainless steel 1mm thick with sink coupling & waste pipe including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm, bowl size 410mm x 330mm x160 mm complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connections etc complete all as specified and directed.
Refixing only old GI tubing 15mm bore pipe and connection in new or old position as on walls, ceiling, floors including cleaning and necessary GI fittings etc.complete all as specified and directed.
S&F 15mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Taking up or down 20mm dia steel tubing and connections etc complete all as specified and directed.
Refixing only old GI tubing 20mm bore pipe and connection in new or old position as on walls, ceiling, floors including cleaning and necessary GI fittings etc. complete all as specified and directed.
S&F 20 mm bore GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S & F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement (Diameter of outlet 75mm), jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1) mixed with pedilite water proofing liquid @ 200ml in 50 kg cement, , connecting up and making good disturbed portion complete all as specified and directed.
Supply & fixing in repairs C.P. grating 100/125 mm dia as reqd at site complete all as directed.
S&F in repair PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors, wall including fittings complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S&F 110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls, floor etc. as per site requirement making good disturbed portion to match the existing complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with cement joints fixed to walls including making good disturbe portion to match the existing complete all as specified.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and cement joint including making good disturbed portion to match the existing complete all as specified and directed .
S&F in repairs 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and cement joint including making good disturbed portion to match the existing complete all as specified and directed.
Dismantling/ demolition of polymeric water proofing membrane single layer with and including plaster, PCC, Padding, brick coba etc on roofs complete including removal of material and debris away from the site etc complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in roof kerbs, paddings, mud stops slightly chamfered or rounded in edges including required grove cutting and including water proofing compound @ 2% by weight of cement complete all as specified and directed.
Material and labour for applying 15 mm thick plaster in CM 1:4 including water proofing compound @ 2% by weight of cement finished even and smooth complete all as specified and directed.
M & L for Provn of polymeric water proofing roof treatment to assessable RCC roof described as under and all as specified :- (a) Preparing RCC roof surface and applying one coat of bitumen primer @ Rs. 0.30 Kg /Sqm (b) Applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm (c) Laying of water proofing teratment with 3mm thick APP modified polymeric water proofing membrane with non woven polyster mat of weight 160gms/sqm as centre core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane unrolled and bonded to substance with side and end laps 75mm and 100mm as per manufacturer’s all as specified. (d) Applying one coat of hot blown grade bitumen 85/25 grade @ 1.20 kg/Sqm over the membrane (e) Finally provide PCC tiles 250 x250 x20mmthick machine made over 1 5 mm thick screed in CM 1:4 grouted and pointed in CM 1:3 mixed with and including WPC @3% by weight of cement all as specified (For accessible roof surfaces)
S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket or PPR pipe etc making good disturbed portion complete all as specified and directed.
S&F in repairs Vitreous China wash hand basin white flat back size 550x400mm including cutting for and pinning in ends of brackets or erecting stand , 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gm) and 32 mm PVC flexible waste pipe 800mm long etc complete all as specified and directed .
S&F in repairs Pillar taps cast copper alloy fancy type with capstan heads chromium plated scrwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for 15 mm dia iron pipe complete all as specified and directed.
S&F in repairs 15mm bore CP stop cock, cast copper alloy fancy type, screwed down high pressure, screwed for iron pipe or for unions and fixed complete all as specified and directed .
Supply and fixed in repair angular valve , 15mm dia, cast copper alloy,CP fancy type with long shank and cup screwd down, high pressure ,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed.
S & F in repairs PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC connections 15mm size with PTMT nuts of length 450mm , connecting up and making good disturbe portion complete all as specified and directed.
S&F in repair 500 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including 20 mm dia PVC float valve (Make: paryag) complete all as specified and directed.
Supply & fixing in repair CP tubular towel rail, 60 cm long, 20mm bore, chromium plated complete all as specified and directed.
S&F in repairs CP brass Soap dish complete all as specified and directed .
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) inlcuding taking out of old lime/cement concrete bedding, unserviceable connections etc connecting up new and making good disturbe portion complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
S & F for rolled steel section as in door frame to receive the door shutter etc Fe 410-W (Gde E- 250) complete all as specified and directed.
M&L for factory made Pressed steel frames 125mm x 60mm x 1.25mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock, strike plate,etc complete including PCC (1:3:6) type C-0 (using 12.5 mm graded stone aggregate) as in filling hollow portion of frame complete all as specified and directed.
S&F mild steel work for hold fast and similar small articles conforming to Fe 410-0 or Fe 310-0 including MS screws, bolts, including tarring with a coat of tar and sanding complete all as specified and directed.
M&L for providing, PCC 1:3:6 type C-1 (using 20mm graded aggregate) for embedding hold fasts including necessary form work etc.complete all as specified and directed.
S & F Second class hardwood factory made door 35mm thick plain framed, panelled shutter (Two pane) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part I) klin seasoned and chemically pressure treated complete all as specified and directed.
Supply & fix Glazed or skeleton factory made door shutter, 35mm thick of second class hard wood (hollock), open rebated and prepared to receive glass, gauge ( without sash bars) with plain, chamfered or rounded, mitred beads for glass etc , size of members of shutters shall be as specified in SSR Part I, section -8 clause 8.24 (a) complete all as specified & directed.
S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 150mm long alluminium handles, cast type, anodized and fixed complete all as specified and directed.
S&F 200 mm long Aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S & F 300 mm mild steel sliding bolt bolt type stove enamelled black with bright bolt not less than 12 mm dia with and including a minium of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed.
S&F Butt hinges, medium weight, cold rolled mild steel, and fixed with screw/ welding (Size of hinges in 100 mm) complete all as specified and directed.
S & F, 150mm floor door stopper of aluminium alloy body and tongue, anodised,with hard drawn steel spring, fixed in floor complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface over 10 cm width or girth including preparation of new or previously untreated wood surfaces complete all as specified and directed
Supply & fix solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes complete all as specified and directed.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification and drawing for Item No. 08080 on page No 149 of SSR 2020 (Part-II).
S & F factory made steel windows with side hung shutters using steel section with glazing bars including box type hinge, 01 'Z' section handle, 02 Nos 100mm MS tower bolt, one steel peg stay etc in each leaf dovetailed or welded complete all as specified and directed.
S & F factory made steel windows with side hung shutters with using 'Z' steel section without glazing bars including box type hinges, 01 'Z' section handle, 02 Nos 100mm MS tower bolt, one steel peg stay etc in each leaf dovetailed or welded complete all as specified and directed.
S & F mild steel framed work such as grill , grating guard bar as in steel window etc complete all as specified and directed.
M&L 3mm thick ordinary quality sheet glass and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
Supply & fix galvanized mild steel wire cloth 0.40 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S & F steel ventilators with top hung shutter & glazing bars hinges, steel peg stay etc dovetailed or welded, size and thickness of members confirming to IS 1038 complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F in repairs dropery rod 25mm dia with PVC pipe over MS conduit, side cups including fixing arrangement with drilling holes in walls brackets etc complete approved quality and colour complete all as specified and directed.
S & F in repair of 25 mm thick particle boards, grade 2 quality, interior grade, commercial type fixed with nails to timber frame work or steel frame as in cupboard shelves, kitchen, cupboards etc including required butt hinges complete all as specified and directed.
S&F Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws but of aluminium anodised (Size of hasp and staple in 125mm) confirming to IS 363 complete all as specified and directed.
S&F 75 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed confirming to IS 1341 complete all as specified and directed.
S&F 100mm long alluminium handles, cast type, anodized and fixed complete all as specified and directed.
M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&Lfor 25 to 35mm thick sand stone slabs in sun shades, chajjas, shelves, cills, landings, cover stones, templets incl cutting chases, pinning in brick work etc n. exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and as directed.
S & F Chimney bars (straight or camber); bearing bars; support of chajja, tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 using 20 mm stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Cutting holes in brick wall built in cement mortor or cement lime mortor and stone wall built in lime mortor or wall of cement concrete of superficial area n. exc 150 sqcm and making good in cement mortor 1:3 or cement concrete 1:2:4 type B1etc complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors / dados, etc laid bedded and pointed in any mortar complete all as specified and directed.
M&L for non skid ceramic coloured tiles (squre/ rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving n exc 15cm thickness (below or above the ground level) built in cement mortar complete all as specified and directed.
M&L,cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate ) as in foundation filling and mass concrete complete all as specified and as directed.
M & L 75 mm thick Cement concrete 1:3:6 type C-2(using 40mm graded aggregate) as in sub base complete all as specified and directed.
M&L Varoda green marble stone 16-18 mm thick in steps, pillars, wndow cills, pillars, window cills, cooking platforms (min size 2.5 X 0.65 m) and like laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary screed bed/ backing coat and rubbing, polishing complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 20-25mm thick over 15mm thick screed bed in CM 1:6. laid and jointed with grey cement slurry mixed with match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for kota stone slab 20-25 thick in riser of steps, skirting, dado and pillar laid over 10mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with match the shade of the slab including rubbing and polishing complete.
M & L for coloured designer chequered tiles 300mm X 300mm exterior grade (ENDURA or equivalent) 12.50 mm thick laid over 15 mm thick screed bed in CM 1:6 set & jointed in neat cement slurry with pigments to match the tile, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FR PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FRLS PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint out side/PVC polycarbonate PVC rectangular block 50 mm deep, including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Make Polycab/Finolex/RR Kablel/Grandlay. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One light point controlled by two 2 - w a y s w i t c h e s , with cables 1.5 sq. mm size
All as per item No 99 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FR PVC insulated sheathed cable with FR PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.. Make : Plaza/Cona/Havells
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed. Make : Plaza/Cona/Havells
Supply and fix socket 5 amps 5 pin flush type, 240 volts. with polycarbonate body complete all as specified and directed.. Make : Plaza/Cona/Havells
Supply and fix socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed. Make : Plaza/Cona/Havells
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd, complete all as specified and directed. Make : Plaza/Cona/Havells
S&F piano type bell push 5 Amp 240 Vlot complete all as specified and directed. Make : Havells/Bajaj/Philips/CG
Supply and fix Call Bell, AC, 230 volts, single pole, complete all as specified and directed. Make : Plaza/Cona/Havells
S&F ceiling rose , PVC/polycarbonate,, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed. Make : Plaza/Cona/Havells
Supply and fix in repair Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed. Make : Bajaj/Havells/Wipro/Philips
Supply and fix in repair of LED Bulb 7 W, warm white complete all as specified and directed. Make : Bajaj/Havells/Wipro/Philips
S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. Make : Havells/Philips/Wipro/Bajaj
Supply and fixing in replacement LED light fitting with high out put diffuser 4 feet, 20 watt 220 V AC, LUMEN < 2000 with lumen efficacy 120 lumen/watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Philips/Wipro/Bajaj
Supply and fixing in replacement LED light fitting with high out put diffuser 2 feet, 9 watt 220 V AC, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Philips/Wipro/Bajaj
Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make : Havells/Philips/Wipro/Bajaj
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed. Make : Havells/Bajaj/Crompton
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers, complete all as specfied and directed. Make : Havells/Bajaj/Crompton
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.. Make : Havells/Bajaj/Crompton
S&F sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing conduit complete all as specified and directed including taking down of existing un serviceable sub main wiring complete.Make Polycab/Finolex/RR Kablel/Grandlay
Supply & fix in replacement sheet metal enclosure MCB distribution board. TPN 415 volts 4 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make : Legrand/Schneider(Acti-9) /L&T .
Supply and fixing in repair MCB TPN 40 to 100 Amps, 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning. complete all as specified and directed. Make : Legrand/Schneider/L&T/Hager
Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link all as specified and directed. Make : Legrand/Schneider/L&T/Hager
Supply and fixing MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.. Make : Schneider/Havells/L&T /Legrand
Supply and fixing MCB SP 1 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.. Make : Legrand/Schneider/L&T/ Hager
Supply and fix in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 Core, Complete all as specified and directed. Make : Havells/Polycab/KEI
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Supply and fix in replacement steelTubes,'light grade' galvansized 40mm dia for cable protection with all fitting and fixed complete to walls and ceiling or laid in floors/road crossing complete all as specified and directed.
Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition. Make : HPL/Schneider/L&T/Hager
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 2mm dia galvanised iron or steel wire complete all as specified and directed.
M/s Tomar Builders
M/S MAHAR CONSTRUCTION
M/s Salim Mohomad
Sree Ram Enterprises
M/s S. K. Construction Co.
Apoorva Constrution
Asha Construction
VIPRABANDHU CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .