| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC C O JAS INDUSTRIES MA ROAD PHOENIX BAY PORT BLAIR 744 102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | ₹43.1 L Quoted ₹43.5 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹45.4 LRejected-Finance | ₹45.4 L | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹45.5 LRejected-Finance | ₹45.5 L | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹46.4 LRejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹46.4 L | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹46.9 LRejected-Finance C O VM UMMER STEWARTGUNJ BAMBOOFLAT SOUTH ANDAMAN PORT BLAIR 744107 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744107 | ₹46.9 L | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | V M YOUSUF L1 | M/s Harjas Construction & Waterproofing Co L6 | RPG AND COMPANY L4 | NAWAZ CONSTRUCTIONS L7 | M/S AMK CONSTRUCTIONS L5 | M/s VMK Construction L2 | M/s K Moorthi L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed | 585 | Sqm | 100 ₹58,500 | 99 ₹57,915 | 135 ₹78,975 | 120 ₹70,200 | 120 ₹70,200 | 115 ₹67,275 | 104 ₹60,840 |
| 2.00 | M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in levelling course to receive top layer complete all as specified | 495 | Sqm | 300 ₹1.5 L | 299 ₹1.5 L | 320 ₹1.6 L | 350 ₹1.7 L | 330 ₹1.6 L | 320 ₹1.6 L | 312 ₹1.5 L |
| 3.00 | M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed | 480 | Sqm | 1,750 ₹8.4 L | 1,892 ₹9.1 L | 1,860 ₹8.9 L | 1,800 ₹8.6 L | 2,000 ₹9.6 L | 1,820 ₹8.7 L | 1,822 ₹8.7 L |
| 4.00 | M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in vertical surfaces such as skirting, dados and riser etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed of cement mortar 1:3 complete all as specified and directed | 30 | Sqm | 1,800 ₹54,000 | 1,946 ₹58,380 | 1,910 ₹57,300 | 20,000 ₹6 L | 1,850 ₹55,500 | 1,820 ₹54,600 | 1,874 ₹56,220 |
| 5.00 | M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed | 15 | Sqm | 1,600 ₹24,000 | 1,730 ₹25,950 | 1,700 ₹25,500 | 1,700 ₹25,500 | 1,700 ₹25,500 | 1,625 ₹24,375 | 1,666 ₹24,990 |
| 6.00 | M&L for coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:3 complete all as specified and directed | 60 | Sqm | 1,650 ₹99,000 | 1,784 ₹1.1 L | 1,750 ₹1.1 L | 1,800 ₹1.1 L | 1,700 ₹1.0 L | 1,690 ₹1.0 L | 1,718 ₹1.0 L |
| 7.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed | 370 | Sqm | 60 ₹22,200 | 99 ₹36,630 | 60 ₹22,200 | 70 ₹25,900 | 65 ₹24,050 | 70 ₹25,900 | 62 ₹22,940 |
| 8.00 | S&F for anodized aluminum snap grid frame work for false ceiling incl hangers 6mm dia/3mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed | 370 | Sqm | 800 ₹3.0 L | 865 ₹3.2 L | 850 ₹3.1 L | 1,000 ₹3.7 L | 850 ₹3.1 L | 810 ₹3.0 L | 833 ₹3.1 L |
| 9.00 | M&L for 4mm thick non asbestos fiber cement building design board of size 605x605mm fixed or laid to aluminum grid work with screws and including preparation of surface with two coat of oil bound distemper over a coat of chalk whiting primer complete all as specified and as directed | 370 | Sqm | 700 ₹2.6 L | 757 ₹2.8 L | 740 ₹2.7 L | 800 ₹3.0 L | 750 ₹2.8 L | 715 ₹2.6 L | 729 ₹2.7 L |
| 10.00 | Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed | 8 | Each | 300 ₹2,400 | 324 ₹2,592 | 320 ₹2,560 | 350 ₹2,800 | 320 ₹2,560 | 360 ₹2,880 | 312 ₹2,496 |
Updated dates
Tender Value
₹43.6 L
EMD Value
₹87,500
Closing Date
19 Feb 2026, 6:00 pmClosed
GE Haddo Sri Vijaya Puram
GARRISON ENGINEER HADDO MILITARY ENGINEER SERVICES HADDO SRI VIJAYA PURAM 744102
ADDITION AND SPL REPAIR TO COMNETCEN SVP OFFICE AT ANC UNDER GE HADDO SRI VIJAYA PURAM
2026_MES_749582_1
8228E8
Open Tender
Civil Works
180 days
GE Haddo Sri Vijaya Puram
As per ENIT
9 documents required · 9 mandatory
₹500
GE Haddo
₹87,500
Yes
23 May 2026
22 Jan 2026
26 Feb 2026
22 Jan 2026
19 Feb 2026
5 Feb 2026
23 Jan 2026 - 30 Jan 2026
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in levelling course to receive top layer complete all as specified
M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed
M&L for light shade vitrified ceramic tiles minimum 8mm thick (square/ rectangular) polished area of each tiles n. exc 0.36 Sqm (600x600mm) in vertical surfaces such as skirting, dados and riser etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed of cement mortar 1:3 complete all as specified and directed
M&L for Non Skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed
M&L for coloured Glazed ceramic tiles in vertical surfaces 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed with white or coloured cement over and including 10mm thick rendering or bedding layer of cement mortar 1:3 complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed
S&F for anodized aluminum snap grid frame work for false ceiling incl hangers 6mm dia/3mm dia GI wire (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60 mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and as directed
M&L for 4mm thick non asbestos fiber cement building design board of size 605x605mm fixed or laid to aluminum grid work with screws and including preparation of surface with two coat of oil bound distemper over a coat of chalk whiting primer complete all as specified and as directed
Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
Taking down Chowkats exc 1.5 Sqm but n. exc 4 Sqm each with shutters (Without taking off shutters from the frame) complete all as specified and directed
M&L for anodised aluminium frame for doors, windows, ventilators, partition with one or more rebates, wind tie including joining cleat for fixing etc complete as specified
M&L for anodised aluminium door shutters, aluminium section weighing not less than 1.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, tower bolts, anodised aluminium snap beading screws etc complete all as specified. Note : Supply only floor spring, glass, SS friction hinges, particle board, wire gauze will be measured seperately
M&L for anodised aluminium window and ventilator shutters, side hung/sliding type without sash bars, aluminium sections weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays/Imax hinges 01 No, hinges type B-21 100mm long 02 Nos suitable handle 01 No per shutter or as required etc complete all as specified Note : Supply only glass, particle board, wire gauze will be measured and paid seperately
S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/ pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed
S&F door closer hydraulically regulated aluminium (die cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified
Supply only sheet glass 4 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter not exc 0.5 Sqm in each pane complete all as specified and as directed
Supply only sheet glass 5.5mm thick ordinary quality and glazing with aluminium glazing clip in aluminium door/window/ventilator shutter not exc 0.5 Sqm in each pane complete all as specified and as directed
Supply only 12mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination, fixed with screws to timber frame work complete all as specified
S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140mm overall length of cover plate complete all as specified and as directed
S&F 250mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm both side prelam PVC sheet and edges will be painted to match with the prelam sheet reinforced with MS square tube in opening incl necessary fixing arrangements as per specification and drawing complete all as specified and directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelam PVC sheet for top rail, lock rail and bottom rail on either side as gap insert for top rails, bottom rail, panelling of both side prelam PVC sheet to be fitting in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement in the frame at site as per specification and drawing complete all as specified and as directed
S&F for 2nd class hard wood (SAL) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
S&F 30mm thick plain, framed, panelled shutters (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers complete all as specified
S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works like cooler stand conforming to Fe-290, Gde -E-165 complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded aggregate stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, holdfast, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L for applying two coats of synthetic enamel paint to new undecorated wooden surfaces over a coat of pink primer including preparation, over 10cm width or girth complete all as specified
S&F 100mm size stainless steel butt hinges medium weight complete all as specified
S&F 150mm aluminium, anodised, barrel tower bolts of extruded section all as specified
S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised all as specified
M&L for 18mm thick HDF boarding (Fire and water proof) as in cup boards/shutters/racks/shelves exterior grade with one side white lamination and other side coloured prelaminated, size of the cabinet as per requirement of the site complete all as specified and as directed by Engr-in-Charge. Make : bajaj/ Kitply/Greenply/ Bhutan board/A-1 Boards/Charminar. Note : (i) Cutting edges of cupboard shutter/ shelves to be finished with adhesive edge binding tape all as directed
S&F stainless steel auto closing hinges 35mm of 0 crank( KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters complete all as specified. Make : Hettich/Harrison/Godrej
S&F stainless steel non megnetic bow handle "D" type anodized 150mm long complete all as specified Make : Hettich/Harrison/Godrej
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth complete all as specified and directed
M&L for applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth after complete removal of existing treatment complete all as specified and directed
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittingS&Fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc to match with existing surrounding surfaces complete all as specified and as directed
Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed
M&L for Point wiring two single core 1.5 sqmm size PVC insulated, unsheathed FRLSH multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLSH multistranded copper conductor cable as earth continuity conductor, 1100 volt grade (with proper colour coding Red/Blue/yellow for phase, black for neutral and green for earth) complete drawn through and including PVC casing and caping not less than 25 mm width with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :- Note 1:- The unit rate quoted shall deemed to include the cost of following :- Make of wire : Polycab/ Gloster/ Anchor/ Havells/ Finolex/ V-Marc and Make of PVC Conduit or Casing & caping : Modi/ Precision/ Supreme/ Finolex/ Polycab. Note 2: (a) GI metal flush box of minimum thickness of 1.6mm and modular cover plate with frame of any module complete. (b) Proper colour coding is to be followed as per IS specification. (c) Wiring shall be concealed/ on surface with rigid PVC conduit medium grade/PVC casing caping as per site requirement. (d) Cutting chases in wall/floor /beam/ceiling to be concealed conduit and making good the disturbed surfaces.
All as per item Ser No 43 above, but , for One light/fan point controlled by one modular switch 6 Amps one way complete all as specified and directed
All as per item Ser No 43 above, but , for two light point controlled by one switch 6 Amps one way complete all as specified and directed
All as per item Ser No 43 above, but, for one modular 3 pin 6 Amp socket out let on independent board complete all as specified and directed
All as per item Ser No 43 above, but , for one modular 3 pin 6 Amps socket outlet on same Board complete all as specified and directed
All as per item Ser No 43 above, but , for one bell point controlled by one modular bell push switch 6 Amps one way complete all as specified and directed
All as per item Ser No 43 above, but , point wiring with 4.0 sqmm PVC FRLSH insulated multistranded copper conductor suitable for one 3 pin 16 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed
S&F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells
S&F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells
S&F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells
S&F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16 Amp , universal complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells
S&F modular bell push 6 Amps 1 modular 230v, 50Hz AC complete all as specified and directed Make : Roma (Anchor)/ Legrand/ Havells
S&F stepped type electronic fan regulator modular type complete all as specified. Make : Roma (Anchor)/ Legrand/ Havells
S&F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete. Make : Anchor/ Legrand/ Havells
Supply & fix Modular Ac Box With 20A DP MCB "C' Type, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top, 240 volts AC supply for air conditioner, flush mounting in the wall complete all as specified and directed Make:- Anchor (Roma) model no 98492 or equivalent in L&T / Havells
Taking down carefully ceiling fan of any make, size from its location, dismantling complete, examine complete parts thoroughly, oiling, greasing all parts and complete overhauling of fan including replacement of small parts such as split pin, nut bolt, screws and assembling back the fan, make fully functional, re-fixing the fan to its position including replacing and providing of twin core copper wire 23/0.0076 from fan to ceiling rose and painting the fan with same colour of fan complete all as directed
S&F air ventilating fan 200 mm sweep single ph, 230 volt, PVC body with louvers incl all fixing arrangement complete all as specified and directed Make: Luker model No-LXCOB HS or equivalent to CG/Havells/ Orient / Usha
S&F of LED slim panel lighting fixture of 18 Watt recess mounted 220V , 50Hz with finished in premium white powder coating ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed Make - Luker Cat Part No : LNPR18 or equivalent make in CG/ Philips/ Havells. Note : The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting .
All as per item sl No 54 above, but, 15 watt. Make - Luker Cat Part No : LNPR15 or equivalent make in CG/ Philips/ Havells
All as per item No 54 above but 61 watt (square shape). Make - Luker Cat Part No : LNPS30 or equivalent make in CG/ Philips/ Havells
S&F and testing Tube light fittings aluminium tubes 22 watts 4 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT522 or equivalent to CG/Philips Havells
S&F and testing Tube light fittings LED 10 watts 2 feet including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Luker Cat Part No : LT510P or equivalent to CG/ Philips/ Havells
S&F and testing LED recessed mounted 595 mm x 595 mm luminarie with high transmitive diffuser of cap 36 watt, with longer life and less maintenance including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: LUKER model No LKM 2236 of any colour (WH/NWH/WW) as reuired or equivalent to Philips/CG/ Havells . Note : The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm dia PVC conduit and conduit accessories fixed on surface of wall/ceiling/roof/ floor complete all as specified and as directed
All as item No 60.00 above, but , four runs (3P+1N) of 6.0 Sqmm. Note : Four runs (3P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories on surface of wall/ceiling/roof/ floor complete all as specified and as directed Note : Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC casing and capping shall be measured as one unit length.
All as per item No 62.0 above but 6.0 sqmm 2 core complete all as specified and as directed Note for item No 62 to 63 : Two runs of copper conductor (1P+1N) , One run of copper conductor as earth wire and one run of PVC casing and capping shall be measured as one unit length
S&F DB VTPN sheet metal enclosure double door suitable for incoming upto MCCB 100 Amps/125 Amps & outgoing MCB TP / SP (IP-43) Protection Triple pole and neutral 415 V 6 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete all as specified and directed
S&F Triple pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 415 V, 50 Hz supply double door TPN DB system 04 ways,including taking down old unserv DB of any type /rating and making good to the distrubed surface /walls.
S&F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 12 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete.
All as per item No 66 above, but , 8 way complete all as specified and as directed
S&F in replacement of MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release alongwith copper separator terminals complete all as specified and as directed
S&F of MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed
S&F of MCB, TP, "C" series, 415 volts, 25-63 Amps, 10 KA rupturing capacity complete all as specified and as directed
S&F of MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed .
S&F of MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed Note for item No 68 to 72 :- All copper conductors should be connected with MCCB/ MCB alongwith copper reducer terminals of suitable size duly crimpled.”
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_839492.xls
BOQ • 0.35 MB
8228TENDER1.pdf
Tender Documents • 1.12 MB