| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.1 L+₹3.2 L (10.3%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹35.8 L+₹4.8 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹35.8 L+₹4.9 L (15.7%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹36.4 L+₹5.4 L (17.5%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹87,000
Closing Date
15 Mar 2021, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Spl repair / replacement of LT OH line into underground cable for security light and certain sanctioned works under GE (Army) Suratgarh at Suratgarh Mil Stn
2021_MES_422841_1
GE (A) SOG - 72/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹87,000
Yes
22 Mar 2021
16 Feb 2021
17 Mar 2021
16 Feb 2021
15 Mar 2021
1 Mar 2021
Amount
Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc including ridges complete all as specified and directed by Engineer-in-charge.
Dismalting chain link fencing of any description fixed to any type of fencing posts complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 7 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for hard core of stone / boulders of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
M&L for PCC (1:2:4) type B1, using 20mm graded stone aggregate as in coping, benching and bed blocks etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished even and fair complete all as specified and directed by Engineer-in-charge.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases splices, angle brackets, cleats and other connections etc conforming to Gde Fe-290 or Gde E- 165, complete all as specified & directed by Engineer-in-charge.
S&F mild steel round bars 10mm dia, cut to length, bent to shape as in tie bar fixed to chain link fencing including necessary welding where required as per site requirement & other similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-charge.
S&F MS screw bolt 05 to 10mm dia, length of bolt not exceeding 50mm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge.
Supply only mild steel galvanized chain link fencing of any mesh, size and type complete all as specified and directed by Engineer-in-charge. Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE.
Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge. Note :- Supply only chain link fencing shall be measured and paid for separately under replace items of BOQ.
S&F in repair galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
S&F mild steel work such as angle iron in posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc., flat iron fillets (for securing wire mesh etc) includingmild necessary welding where required as per site requirement and other similar works complete, conforming to Gde E-165 (Fe 290) complete all as specified and directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor, top surface finished fair & even including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and as directed. Note :- PCC shall be laid in alternate bays in panels of size not exc 2m x 1m and joints shall be filled with bitumen mastic (1:3). Quoted rate shall deemed inclusive for same.
S&F factory casted 60mm thick machine pressed cement concrete interlocking paving blocks M-35 having compressive strength not less than 350 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid over & including 25mm thick sand cushion (local tibba sand), laid dry, joint filled with dry sand complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment including preparation of surfaces and applying two coat of exterior emulsion paint on walls over a coat of exterior primer complete all as specified & directed by Engineer-in-Charge. Note :- After complete removal of existing treatment surfaces shall be inspected by the Engineer-in-Charge and further each coat of exterior paint and primer shall be applied only after passed by Engineer-in-Charge.
M&L for complete removal of existing treatment including preparation of surfaces and applying two coats of cement base paint shade/tint on walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new untreated steel and iron surfaces of any description, not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge
Hacking out old broken glass any thickness, size, quality or description from wooden / metal frame and punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engineer-in-charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F in replacement 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches / sunken complete all as specified and directed by Engineer-in-charge.
S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
S&F gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 600mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F in repair Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
M&L for removing loose ceiling plaster completely, cleaning and dripping mortars and curing of effected surface area, cleaning well expossed reinforcement and applying two coats of anti-corrosive paint to it, supply and fixing mild steel XPM mesh of size 25mm x 25mm (wire dia min. 2mm) to the effected ceiling surface either by welding with exposed reinforcement or by stapling nails or screw or tie with reinforcement, applying cement slury and 25mm thick microphone of 1:1:1 using 6mm graded aggregate and cuting it for 3 days and then making well finish the surface using cement mortar 1:3 complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete with 2.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 2.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
S&F switch piano flush button 15 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3/5 pin, 15 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
Supply installing & testing water cooler of 80 Ltr storage capacity with nominal cooling capacity 40 Ltr per hour, single phase, 230 volts, Five Star Rating with necessary inlet connection with HDPE / Flexible pipe both ends CP brass union for GI Pipe and ball brass valves complete including electric connection through voltage stabilizer complete all as specified and directed by Engineer in charge. Note :- Voltage stabilizer shall be measured and paid seperately under respective items of BOQ
Supply, installing & testing Voltage Stabilizer of capacity 2 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge.
S&F street light bracket made out of 32mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F in repair street light bracket made out of 32mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing of LED Street / Security light fitting of 45 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Crompton Cat Part No LSTV-45-CDL / Havells Cat part No ENDURAPEARL NEOSL45WLED757SASYTOPC / Wipro Cat Part No LR02-501-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per Srl item No 59 above but LED street / security light of 25 watt including taking down old light Make :- Make :- Crompton Cat Part No LSTS-25-CDL/NL-M / Havells Cat part No. ENDURAPEARL SL25WLED757SASYTOPCMP / Wipro cat part No LR02-291-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
All as per Srl item No 59 above but LED street / security light of 60 watt including taking down old light Make :- Crompton Cat Part No LSTP-60-CDL-M / Havells Cat part No. ENDURAPEARLNEOSL60W LED757PA SYTOPC / Wipro cat part No LR02-671-XXX-57-G2 or equivalent in makes mentioned in Appendix 'A' here-in-after.
Notes for srl Item No 59 to 61 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
M&L for Construction of brick masonry valve pit of internal size 110cm x 110cm x 110cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 25mm x 4mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts / nuts / washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position (iv) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 64 above but cable of cross sectional area 16 sq mm 4 core
All as per item No 64 above but cable of cross sectional area 300 sq mm 3.5 core
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
All as per item No 69 above but 50mm bore tubing including taking out old tubing
All as per item No 69 above but 32mm bore tubing including taking out old tubing
All as per item No 69 above but 15mm bore tubing
All as per item No 69 above but 15mm bore tubing including taking out old tubing
Dismantling existing unserviceable Aluminium conductors, steel reinforced (ACSR conductor) from overhead lines on LT poles, of any type and any size complete all as specified and as directed by Engineer-in-charge
Disconecting and taking down existing unserviceable bracket and unserviceable street light fittings of any type/ make and refixing in existing or other position including connection with cable from security light to pole box along with accessories as directed by Engineer-in-charge. Notes:- (i) Any T & P and Ladder wheel required for the work shall be arranged by the Contractor. The rate of this aspect is included in this item and nothing extra shall be paid on this account.
Dismantling existing unserviceable cross-arms of M.S. channel or angle sections etc. of any size and type complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking down insulators of any type and size complete all as specified and directed by Engineer-in-Charge.
S&F street light pole box of size not less then 300x200x105mm, made of high quality thermo plastic polystyrene, weather proof, dust, jet water proof, chemical, acid corrosion, impact, insulated & shock proof IP 65 for outdoor Installation with internallly embedded gasket (PUR) including MCB SP 6 Amps 01 No along with left side hinge door (notch arrangement not acceptable) & premoulded knockout all sides including back of the base must. The box fitted with 10 sqmm stud type terminal - 04 Nos including Elimex stud type TB 4 Nos. Note :- (i) Cost of flat iron clamp is deemed to included in unit rate of this items. Nothing extra shall be paid on this account. (ii) Size of junction box for different mafufacturer may slightly varried from size mentioned in description of item. Contractor has to provide junction box as per cat No mentioned against make of junction box. where cat No is not mentioned against any make, in that case junction box of size mentioned in description has to provide, if exact size of junction box is not available, then next higher size junction box has to be provided. Nothing extra shall be paid on this account.
S&F PVC insulated stranded copper conductor, 1100 volts grade, 2.5sqmm 3 core size of ISI marked connection from security light to pole box complete all as specified and directed by Engineer-in-Charge.
S&F three phase automatic street light switch suitable for 5 KW load complete with Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a Rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure with hinged lid confirming to IP66 protection class 2. The circuit should also have provision for manual operation (i.e. sensor By-pass option). The enclosure should be platform mounted and structure must be grouted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm complete all as specified and directed by Engineer in charge. Make :- KAKATIYA ENERGY SYSTEM PVT LTD (Swadeep 02EC3KW1P) or equivalent in makes mentioned in Appendix 'A' here-in-after.
S & F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998 erecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and yellow colour up to 1.5 metre height from top of PCC pedestal/coping of poles including numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed by Engineer-in-Charge. Note : PCC for foundation and earth work shall be measured and paid for separately.
Supplying, jointing and testing heat shrinkable type,out door type, end termination jointing kit, suitable for cable of size 240 to 300 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 4 Pole 160 Amps, thermal magnetic release having, breaking capacity 36 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 40x6 mm aluminium strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge.
Supplying, installing, testing and commissioning of thermoplastic polycarbonate IP 65 outdoor type in accordance with EN 60 529 (dust proof, weather proof & water proof) power distribution board of suitable size as per Engineering practice, shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant & self extingushing, UV Resistant, silica and halogen free recyclable material, glow wire tested at 960⁰C in accordance with IEC 60 695-2-11. type tasted as per IEC 61 439-1. total insulated with system. The manufacturer of board / panel shall submit a copy of ASTA certification by CPRI for the Degree of ingress protection in accordance with IEC 60529. The gasket material shall be polyurethane while the gasket shall be internally embedded including provision for taking incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable , danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs. The manufacturer of board / panel shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with IEC 61 439-1. The report shall have mention of following tests performed and passed out satisfactorily:- (i) Tempreture rise. (ii) Dielectric properties (iii) Short circuit withstand current - rated peak & short time with stand current and rated conditional short circuit current. (iv) Efffectiveness of protective circuits (v) Clearance & Creepage distance (vi) Degree of protection (vii) Mechanical operation
Contd/-... Srl Item No 84 The impact strength of polycarbonate enclosure / boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm with and including following accessories :- Incoming (a) 250 Amps copper bus bar for phases and Neutral - 01 Set (b) MCCB 160 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 160, 420097 or equivalent in makes mentioned in Appendix 'A' here-in-after. Outgoing (a) MCCB 63 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 02 Nos Make - Legrand Cat Part No DPX³ 160 420053 or equivalent in makes mentioned in Appendix 'A' here-in-after. (b) MCCB 40 Amps, 16 KA, 4 Pole, thermal Magnetic release type - 03 No Make - Legrand Cat Part No DPX³ 160 420052 or equivalent in makes mentioned in Appendix 'A' here-in-after. (c) Digital Voltmeter flush type 0-500 Volts square type 96mm x 96mm - 01 No (c) Digital Ampere meter flush type 0-200 Amps square type 96mm x 96mm - 01 No (d) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S&F in replacement pipe ERW steel including special fittings i.e. flanged band, reducer etc of nominal dia 200mm as per IS : 3589 (1981) Gr. 330 thickness minimum 6 mm fixed to wall, passing through concrete wall on support structure, floor / trenches etc. including welding work and two coat of synthetic enamel paint as per existing colour code on outer surface of pipe and making of fluid name with direction on pipe complete all as specified and as directed by Engineer-in-Charge. Note : Rate includes the cost of all welding work, cement work, jointing flanged and fittings and making holes for movement of sewage water as required etc.
All as per item No 85 above but 150mm dia
All as per item No 85 above but 100mm dia
S&F in replacement of GI pipe heavy class inlcuding all fittings size 80 mm dia fixed on wall, frame structure, laid in floor, trenches etc including making holes for movement of sewage water as required and two coat of synthetic enamel paint as per existing colour code on outer surface of pipe and marking name of fluid and direction on pipe complete all as specified and as directed by Engineer-in-Charge.
All as per item No 88 above but 50mm dia
All as per item No 88 above but 40mm dia
S&F in replacement of pipe ERW steel of dia 200 mm of 1 mtr length with one end colsed and one end flanged having holes of size 10-12 sqmm on circumference for water outlet as per existing sample complete all as specified and as directed by Engineer-in-Charge.
Supply and laying in replacement of MBBR bio pac Media for sewage treatment, fluidized bio media, made of vigin PP UV stablized, media height 16 mm, media diameter 22 mm with effective specific surface area of media 400 m2/m3 colour white, cylindrical with external fins, min voidage 98% complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Tube settler media for sewage treatment, square shape, PVC, separator height 500mm, with 5.5 m2 settling area/m2 by taking out oud unserviceable and fixing new by necessary cutting as required complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of water pressure gauge, Stainless Steel body (0-16) kg/cm2 complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of air pressure gauge Stainless Steel body (0-16) kg/cm2 complete all as specified and as directed by Engineer-in-Charge.
Demolition of old u/s foundation of centrifugal pumpset capcacity 20 HP and fabrication of common angle iron base frame for pump and motor fixed in concrete foundation as per original specificaiton with grouting of bolts for fixing of frame as directed by Engr-in-charge. Note: (i) Angle iron frame will be measured and paid seperately. (ii) Rate includes the cost of removing of pumpset from foundation and keeping aside and refixing of the same with proper alignment after foundation work.
Cutting existing CI/DI water tubing 150mm bore for insertion of flanged tee including necessary welding work / thread work and including insertion of necessary fitting new tee of size 150mm x 150mm x 80mm alterations or additions (each cut measured), complete all as specified and as directed by Engineer-in-Charge. Note :- Cost of fittings and tee required is deemed to included in the unit rate of this item. Nothing extra shall be paid on this account.
Supplying, fixing and testing of 80mm bore cast iron sluice valve with langed ends drilled ISI marked class PN - 1.6 conforming to IS 14846-2000 with stainless steel spindle with iron wheel, CI gate with brass nut, bolts, washers and rubber packing for connecting pieces etc complete all as specified and as directed by Engineer-in-Charge.
Suppyling, installing, testing and commissioning in replacement of factory made indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2.00mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
S&F in repair chain Pulley, Hand operated, capcity 200 kg for submersible pump set, with chain, pulley, hook complete all as specified and directed by Engineer-in-charge.
S&F in replacement butterfly valve of size 150mm, CI body, SS disc & stem, lever operated conforming to IS-13095 with nut, bolts, washer and gasket complete all as specified and directed by Engineer-in-charge.
All as per item No 101 above but 100mm dia
All as per item No 101 above but 80mm dia
All as per item No 101 above but 50mm dia
All as per item No 101 above but 40mm dia
Supplying, laying & jointing in replacement submersible cable flat type, copper conductor of size 10 Sqmm, 3 core complete all as specified & as directed by Engineer –in-charge.
Supply, install and testing in replacement of sodium hypochlorite dosing system, outdoor type with dosing capacity 6 Ltrs per hour at pressure 4 bar, PTFE diaphragm, LED display, 110-250 V, 50 Hz inpurt power supply and mounted on 200 Ltrs PVC storage tank (initially filled with sodium hypochlorite 200 kg) with all electrical connection upto eletrical panel and inlet and outlet pipe upto clear water tank complete all as specified & as directed by Engineer –in-charge. Note: Old unserviceable dosing system shall be deposited in AGE E/M store yard by the contractor at his own arrangement. Noting extra shall be paid on this account.
M&L for testing of treated water of STP (PH, TSS-, COD, BOD) from recognized laboratory and submitting the test report complete all as specified & as directed by Engineer –in-charge.
S&F gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge. --------------------------------------------------------------------- Note :- A sum of Rs. 157039/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 28 & 29 (Schedule of Credit) of Tender documents.
M/S GODARA CONSTRUCTION CO.
MISHRA CONSTRUCTION COMPANY
BHADU BUILDERS
GURDEEP SINGH AND COMPANY
SHARMA CONSTRUCATION COMPANY
GARG ENTERPRISES
M/s Yash Electrical and Maintenance
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .