Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹10.4 L+₹45,805 (4.60%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance not lowest | |
| 3 | L3₹11.1 L+₹1.1 L (11.5%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINTANENCE OF AIR COOLING DUCT SYSTEM AND CONNECTED ACCESSORIES AT COMMAND BLDG AT VSN NAGPUR
2022_MES_501605_2
GE/NAG/21-22/8506/58
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹24,000
31 Mar 2022
19 Feb 2022
14 Mar 2022
19 Feb 2022
12 Mar 2022
26 Feb 2022
60 days
Amount
Taking down electric motor 30/25 HP 415 volt coupled to pump after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to workshop, checking the serviceability of ball bearing both side of motor, greasing of bearing upto free rotation of shaft of motor greasing on re-assemblying the motor complete, reinstallation on foundation, reconnecting back the cable and earth connections and varnsihing, drying, opening, overhauling, greasing, Alignment pump/motor properly by authorised mechanic including repair to foundation if required at site etc complete in all respect and starting the pump all as directed. Note:(1) Contractor shall be responsible for maintaining required RPM after repair, non compliance of speed will be considered as incomplete repair. (2) Cost of Rewinding & Bearings shall be measured and paid separately.
Taking down electric motor 0.5 upto 1 HP 415 volt coupled to pump after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to workshop, checking the serviceability of ball bearing both side of motor, greasing of bearing upto free rotation of shaft of motor complete, greasing on re-assemblying the motor to re-installation on foundation, re-connecting back the cable and earth connections and varnishing, drying, ovening, overhauling, greasing, Alignment pump/motor properly by authorised mechanic including priming of PVC foot valve etc complete in all respect and starting the pump all as directed. Note :(1) Cost of rewinding , Bearings shall be measured and paid separately under relevent item. (2)Contractor shall be responsible for maintaining required RPM including Priming work for motor for taking out water cellouse pads after repair ,non compliance of speed will be considered as incomplete repair
Supply only spare parts for pump set of capacity 30/25 HP vide item No.1 as follows:- a) Supply only Motor shaft as per exiting site requirement complete
b) Supply only check nut
c) Supply only ball bearing as per existing site requirement fitted in motor complete Make : SKF/Timker/NSK/URB
M&L for Dark Blue Colour of synthetic enemal painting of air blower motor /blower stand and floor of ambient chamber , water pump including motor of capacity upto 35 HP Including 0.5 HP water pump after removing all dust, dirt etc, clean the surface thoroughly and apply two coats of synthetic enamel paint by spray painting including writing MES No complete all as specified and directed . MakeAsian paint/Berger/Nerolac paint
M&L for Dismantling of existing defective/unserviceable motor of following capacity, three phase/Single phase , 415 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, transportation to work shop, separating the stator and rotor assembly ,cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding of stator with super enamelled solid copper conductor (winding wire) of appropriate gauge and size to match with the existing winding motor so as to achieve desired RPM , including varnishing, drying, ovening, overhauling, greasing, providing insulation and reassembling stator and rotor, connecting coils/ winding in star and delta mode at the junction box/terminal, fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed by Engineer-in-Charge. (a) 0.5 up to 1 HP
(b) All as per Item No 7.00 herein before but 30/ 25 HP
Supply and laying LT Rubber mating chequered of size 2 mtr x 1 mtr x12 mm thick as per ISI mark complete all as specified and directed.
Taking down U/s ACP sheet and supply and fix ACP Sheet of thicknes 4 mm with 0.5mm thick aluminium cladding on both side including framework with 25x50mm aluminium pipe for AHU fixing in out side of AHU complete all as specified and directed. Make :Hindalco/Nalco/Balco
Taking down u/s and Supply and fix industrial Exhaust fan axial flow motor with blade and frame heavy duty industrial exhaust fan (36 inch with IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and scid alkali fumes , totally enclosed highly efficient heavy duty copper motor including testing of motor with suitable copper wire winding ,including refixing of exhaust fan motor with blade and frame, AC, volts, Heavy duty and blades 36 inch sweep, suitable for air washer plant complete all as specified and directed. Make :- CG,Havells or bajaj, Blowtek
Taking down U/S & Supply & fixing V belt cat part MN 30 for capacity of 30000 to 40000 cfm blower motor suitable for the existing plant size 32/20 complete all as specified and directed. Make Mitsuboshi/Dunlop/Poly-F
Supply & install Blower pully as per existing blower capacity fitted in site for air washer ambiator chamber including taking down old u/s pulley complete all as specified directed by Engr-in-charge. (Sample availabe at AGE E/M office)
Taking down U/S old nitrile insulation / glass insulation & supply and fix new Nitrile insulation 13 mm thick nitrile rubber sheet with suitable adhesive of duct work fixed out side of duct/ inside duct and air washer chamber for weather proofing using 13 mm thick nitrile rubber sheet fixing with nylon cloth complete all as specified and all as directed by Engr-In--Chargre Note 01: The cost of Nitrile insulation patch occured during contract period maintenence shall be deemed to be included in this item rate. Make : K-flex/Armacel/Suprem
Taking down U/S old nitrile insulation / glass insulation & supply and fix new Nitrile insulation 25 mm thick nitrile rubber sheet with suitable adhesive of duct work fixed outside of duct/ inside duct and air washer chamber for weather proofing using 25 mm thick nitrile rubber sheet fixing with complete all as specified and all as directed Note No-01 The cost of Nitrile insulation patch occured during contract period maintnence shall be deemed to be included in this item rate. (2) Aluminium strip 25x3mm will be measured and paid separately Make : K-flex/Armacel/Suprem
Supply and fix aluminium strip 25x3 mm thick by providing suitable support for fixing of nitrile insulation inside/outside of AHU and duct for air washer plant complete all as specified and directed. Note: (1) The cost shall be deemed to be included making holes in strip , nut bolts and washers etc all as specified and as directed
M & L for Scaffolding by using steel structure etc for repair of Existing duct insulation defected portion of duct & material and labour for erected with steel structure for repairing work in CMD building site and rigidly supported safe working height 13 mtrs complete all as specified and directed. Note :Removing structure after completion of repairing work, cost of labour and transportation shall be included for the same
Taking down U/S and S & F short neck of duct connected with air diffuser with long type and complete fixing with air sealed diffuser for avoiding of noise and air leakage complete all as specified and directed. Note : If found leakge or noise in the duct or plant the contractor shall be responsible to repair the same without any extra cost.
Taking down U/S & supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre-filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 60cmx60cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design complete all as specified and directed. (sample available as AGE E/M office) Make : Alpha Kel India/AAF Camfil/Freudenberg
Taking down U/S & supply and fix high performance plated panel or air pre-filters for central cooling system and general ventilation used as pre-filtration made of GI /Aluminium construction having efficiency 90% down to 20 micron suitable for existing plant size of filter 30cmx30cm, having features low initial pressure drop, disposable,washable , maintenance free, compact design complete all as specified and directed. (sample available as AGE E/M office)
M&L for cleaning of rusted portion of duct and dust settled in existing duct & dampers in whole building where is passing of duct and Air all floors going from main duct to connected branch duct, number unit duct and diffusers and open of AHU cleaning the portion & refixing the same plant by using suitable equipment or suction machine/compressor from AHU to neck duct complete all as specified and directed. Note: Rusted portion of duct should painted in red oxide, rate of same shall be deemed to be included in quoted rate
M&L for Comprehensive maintenence /overhauling /repair of complete air washer ambiator chamber including necessary oiling/greasing, cleaning and re-alignment of motor properly by technican, visit if any motor alignment with blower of existing plant of capacity 10000 to 40000 CFM, Grease gun shall be used for greasing whenever necessary complete all as specified and directed. Make of Greasing : Castrol/Lithium Grease/ServoMP3 Note :(1) The materias for Oil/Greasing including labour shall be provided by the contractor without any extra payment. (2) Monthly basis for oiling/greasing comprehensive maintenance air washers properly and shall be intimated Engr-in-charge before work excution.
Taking down U/S & supply and fix aluminium grills for air supply made out of powder coated extruded aluminium grills adjustable type with variable angle and verticle and horizantal louvers and gap between louvers should be 25 mm with volume controls dampers complete all as specified and directed. Make:Aircon Airiqpment/Mapro/Air flow Note : (a) Damage of Aluminium grill fitted in site including cutting of wall and POP work shall be deemed to be included in quoted rate.
Taking down U/S Cellulose or celldek pads and supply and fix new consists for cellulose wood fibres in paper form having high quality standard and posses on efficiency of more than 85% complete all as specified and directed (sample available as AGE E/M office) Make Hutek/Munters/DRI Note : Contractor should noted that only damage portion is to be changed.
Supply only grease for suitable for pump bearings complete all as specified and directed.
Taking out U/S & supply and fix ball Bearing for Blower shaft fitted in site for air washer ambiator chamber complete all as specified directed by Engr-in-charge. (sample available as AGE E/M office)
Takin down U/S & Supply & install Motor pully as per existing Motor capacity fitted in site for air washer ambiator chamber complete all as specified and directed by Engr-in-charge.(Sample availabe as AGE E/M office)
Taking down u/s exhaust fan heavy duty of size 36 " removing old unserviceable copper winding , rewinding the same with existing gauage copper wire winding complete including testing after rewinding and repainting with existing colour and refixing in original position complete all as directed by Engr-In-Charge.
Taking down u/s and Supply and fix MCCB 4 pole 63 amps, breaking capacity 10 KA, confirming to IEC60947-2, 415 volts, 50 Hz including making necessary incoming and out going electrical connection with suitable size of copper lugs etc. complete all as specified and directed. Make : Legrand Cat No. 408702 /hager Siemens
Taking out unservicable & S & F MCCB 4 pole 200 amp , breaking capacity 36 Ka, 415 volts, 50 Hz confirming to IEC60947-2 including necessary incoming and outgoing electric connection with suitable size of copper lugs etc. complete all as specified and directed. Make : Legrand Cat No 408702 / Siemens/schneider,Ckt Breaker Easy pact cvss250 f ,Thermal magnetic TM- d trip unit 4p 3d
Taking down U/S Air cooler ambient chamber tray (Tray size sample availble at site) and M & L for Air cooler ambient chamber tray by using 2 mm thick GI Sheet including necessary cutting ,welding fabricating etc for complete tray/portion of tray etc required for fabrication and tightening of door handle and damage any door handle to replace the same complete all as specified and directed Note No -01 The cost shall be included for suitable arrangement of welding machine, electric arrangemenet / gas cyclinder . Note No-02 The cost shall also be included for dismantling of pre-air filter, water pump , water piping and cellulose pads from water cooler tray and refixing of the same after rectification of leakage and completely leak proof arrangementof tray as specified and as directed. If any air filter / celluose pads damaged during execution , The contractor will rectify the same free of cost.
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting upto the electrical system of size 4 sqmm 3 core complete all as specified and directed.
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting upto the electrical system of size 2.5 sqmm 3 core complete all as specified and directed.
Taking out unserviceable control burnt wiring including unserviceable spares from control panel of central air cooling duct and M & L for new control wiring with FRLS copper wire of existing size and length by using suitable lugs/thimble etc complete including replacement of old unserviceable spares and Spares will be measured and paid separetely under relevant items and making necessary setting to work the plant in Auto-mode complete all from existing panel all as specified and as directed. Note Spare part will be measured and paid separately. Make - POLYCAB, FINOLEX.Havells
Supply only RYB indicator complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only voltmeter CTs 0-500 Volt Digital type complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only Amp meter CTs 0-300 Amps complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only over laod relay range 0.2-15 A complete all as specified and directed. Make: Make : Schneider/L&T/Siemens
Supply only Auxillary contactor 2 NO-2 NC complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only on delay timer 0.2 to 60 second complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only push button start/ stop complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only red indication complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only yellow indication LED neon bulb complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only green indication LED neon bulb complete all as specified and directed. Make : Schneider/L&T/Siemens
Taking down u/s and supply and fix 4 sqmm copper wire for internal wiring single core FRLS complete all as specified and directed. Make : Finolex/Polycab/Havells
Taking down u/s and supply and fix suitable sizew copper lugs fitted in motor complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only Add on 2 NO - 02 NC M MCX 9-80/MO 9-110 complete all as specified and directed. Make : Schneider/L&T/Siemens
Supply only spreader link kit complete all as specified and directed. Make : Schneider/L&T/Siemens
Taking down U/S & supply and fix GI duct of difference sizes made out of MS flat iron of any size duly cutting , bending to shape required , welding as required for different size ducts and making hole on flat iron for fixing anchor bolts at RCC slab complete all as specified and directed
Taking down U/S & supply and fix MS angle frame work for installation of GI duct of different sizes , made out of MS angle iron of any size including fabrication of suitable frames for GI ducts different size ducts and making hole for fixing nut bolts complete all as specified and directed.
Taking out unserviceable & S&F MCCB 4 pole 100 amp, breaking capacity 16 Ka, 415 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed. Make- Schneider, L&T/ Siemens
Supply only Power contactor 3 pole 415V AC type 32A MNX 50 complete all as specified and directed. Make : L&T Cat No. ST19001 or equivalent in Siemens, C&S.Schneider, L&T
Supply only Power contactor 3 pole 415V AC type 16A MNX 50 complete all as specified and directed. Make : L&T Cat No. ST19001 or equivalent in Siemens, C&S.Schneider, L&T
Supply only electronic type ET 100 with time range 0 to 60 second, 360 Volt complete all as specified and directed. Make : L&T Cat No 3 Each Q1748 or equivalent in Siemens, C&S. Schneider , L&T
Taking out u/s and supply and fix PVC insulated 1100 volt grade heavy duty cable multistranded copper conductor and connecting panel to Exhaust fan to the electrical system of size 4 sqmm 3 core complete all as specified. Make- Polycab, Havells, Finolex
Taking down U/s and supply and fix Push Button Remote Kit complete all as specified and directed. Make- Schneider ,L&T/ Siemens
Taking down U/S & dismantling of canvash Airwaisher toi Duct supply and fix high performance Double layered Flixible canvash Duct to Airwaisher complete all as specified and directed. Make- Resistoflex, donlop Aircon, Airequipment
Shri Sai Enterprises
Paragon Electrotechnics
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .