| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAdmitted-Finance | ₹15.6 L | L1 | Admitted-Finance |
| 2 | L2₹19.5 L+₹3.9 L (25.2%)Admitted-Finance | ₹19.5 L+₹3.9 L (25.2%) | L2 | Admitted-Finance |
| 3 | L3₹24.7 L+₹9.2 L (58.9%)Admitted-Finance | ₹24.7 L+₹9.2 L (58.9%) | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-FDR / EMD not submitted by the contractor. |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Raj Engineering Co. L3 | ABS ELECTRICAL COMPANY L2 | K R ELECTRICAL L1 |
|---|---|---|---|---|---|---|
| 1.01 | Supply, Installation, testing & commissioning of 415 Volts LT panel made out of sheet steel enclosure of 2mm CRCA sheet totally enclosed, powder coated, mounted on heavy MS base frame, panel should be designed as per space available at site, dust& vermin proof, outward opening, front operated, cable entry from bottom, incomer & each outgoing feeder must have terminals of appropriate size in a cable alley to connect field cables, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets.The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be 50x6 mm in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire. MCCB installed in the panel shall be thermal magnetic type& door operated, MCB shall be C curve type. LT Panel having following components as per DJB approved makes:
(1) Incomer MCCB 415 Volts, 4 pole, high breaking capacity 50 KA, 50 Hz, 200 Amp with spreader - 01 No.
(2) On load change over switch for DG supply 200 Amp - 01 No.
(3) Outgoing motor feeder MCCB 415 Volts, 3 pole, high breaking capacity 50 KA, 50Hz, 100 Amp with spreader - 06 Nos.
(4) Outgoing MCCB 415 Volts, 4 pole, high breaking capacity 50 KA, 50 Hz, 100 Amp with spreader- 01 No.
(5) MCB four pole 63 Amp - 03 Nos.
(6) MCB double pole 32 Amp - 05 Nos.
(7) MCB single pole 6 Amp - 16 Nos.
(8) Over load relay 36- 60 Amp - 06 Nos.
(9) Over load relay 4.5 - 7.5 Amp - 04 Nos.
(10) Power Contactor 220V 3pase 70 Amp - 12 Nos.
(11) Power Contactor 220V 3 phase 40 Amp - 06 Nos.
(12) Power Contactor 220V 3 phase 18 Amp - 04 Nos.
(13) Star delta timer on delay - 06 Nos.
(14) Current transformer 200/5 - 06 Nos.
(15) Current transformer 100/5 - 39 Nos.
(16) Digital Amp. meter - 09 Nos.
(17) Digital Volt meter - 02 Nos.
(18) Indicating lights LED type RYB & ON/OFF - 39 Nos.
(19) Push button start - 10 Nos.
(20) Push button stop - 10 Nos.
(21) Over load relay reset push button - 10 Nos.
(22) Motor protection relay M10 type - 06 Nos.
The work also includes dismantling of existing LT panel and installation, Testing &commissioning of new LT Panel with termination of cables including supply & fixing of cables, thimbles, lugs etc. wherever required, checking continuity, megger testing, alignment of doors, tightness of nut and bolts etc. to the satisfaction of engineer in charge. | 3 | Jobs | 20,97,000 ₹24,74,460 | 16,53,000 ₹19,50,540 | 13,20,000 ₹15,57,600 Lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
21 Aug 2026, 2:30 pmClosed
EE(EnM)
40 MGD WTP Nangloi
SITC of LT Panel 415 volts at Pkt. B2, A and C BPS at Loknayakpuram Bakkarwala.
2026_DJB_296516_1
NIT No. 6 (2026-27)/ EE(EM)WTP-Nangloi
Open Tender
Miscellaneous Works
Works
90 days
WTP Nangloi
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
As per tender documents.
₹50,000
14 Sept 2026
5 Aug 2026
21 Aug 2026
5 Aug 2026
21 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply, Installation, testing & commissioning of 415 Volts LT panel made out of sheet steel enclosure of 2mm CRCA sheet totally enclosed, powder coated, mounted on heavy MS base frame, panel should be designed as per space available at site, dust& vermin proof, outward opening, front operated, cable entry from bottom, incomer & each outgoing feeder must have terminals of appropriate size in a cable alley to connect field cables, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets.The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be 50x6 mm in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire. MCCB installed in the panel shall be thermal magnetic type& door operated, MCB shall be C curve type. LT Panel having following components as per DJB approved makes:
(1) Incomer MCCB 415 Volts, 4 pole, high breaking capacity 50 KA, 50 Hz, 200 Amp with spreader - 01 No.
(2) On load change over switch for DG supply 200 Amp - 01 No.
(3) Outgoing motor feeder MCCB 415 Volts, 3 pole, high breaking capacity 50 KA, 50Hz, 100 Amp with spreader - 06 Nos.
(4) Outgoing MCCB 415 Volts, 4 pole, high breaking capacity 50 KA, 50 Hz, 100 Amp with spreader- 01 No.
(5) MCB four pole 63 Amp - 03 Nos.
(6) MCB double pole 32 Amp - 05 Nos.
(7) MCB single pole 6 Amp - 16 Nos.
(8) Over load relay 36- 60 Amp - 06 Nos.
(9) Over load relay 4.5 - 7.5 Amp - 04 Nos.
(10) Power Contactor 220V 3pase 70 Amp - 12 Nos.
(11) Power Contactor 220V 3 phase 40 Amp - 06 Nos.
(12) Power Contactor 220V 3 phase 18 Amp - 04 Nos.
(13) Star delta timer on delay - 06 Nos.
(14) Current transformer 200/5 - 06 Nos.
(15) Current transformer 100/5 - 39 Nos.
(16) Digital Amp. meter - 09 Nos.
(17) Digital Volt meter - 02 Nos.
(18) Indicating lights LED type RYB & ON/OFF - 39 Nos.
(19) Push button start - 10 Nos.
(20) Push button stop - 10 Nos.
(21) Over load relay reset push button - 10 Nos.
(22) Motor protection relay M10 type - 06 Nos.
The work also includes dismantling of existing LT panel and installation, Testing &commissioning of new LT Panel with termination of cables including supply & fixing of cables, thimbles, lugs etc. wherever required, checking continuity, megger testing, alignment of doors, tightness of nut and bolts etc. to the satisfaction of engineer in charge. | 3 | Jobs | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
BOQ_394725.xls
BOQ • 0.26 MB
CORRIGENDUM.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .