Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹20.8 L+₹76,095 (3.79%)Rejected-Finance B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | SAMEER ELECTRICAL SUPPLIER L2 | Raj Contruction L1 |
|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||
| 1.10 | Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed. | 50 | Each | 300 ₹15,000 | 280 ₹14,000 Lowest |
| 2.00 | All as per item No.1.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts complete all as specified and directed. | 6 | Each | 300 ₹1,800 Lowest | 300 ₹1,800 Lowest |
| 3.00 | All as per item No.1.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts complete all as specified and directed. | 15 | Each | 250 ₹3,750 Lowest | 250 ₹3,750 Lowest |
| 4.00 | All as per item No. 1.00 here-in-before but wall / pedestal fan, of any sweep and capacity complete all as specified and directed. | 5 | Each | 300 ₹1,500 Lowest | 300 ₹1,500 Lowest |
| 5.00Note: - for items No 1 to 4. (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before star work (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted. | |||||
| 6.00 | Supply and fix in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed. | 20 | Each | 600 ₹12,000 Lowest | 600 ₹12,000 Lowest |
| 7.00 | S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed. | 50 | Each | 15 ₹750 Lowest | 15 ₹750 Lowest |
| 8.00 | S&F in replacement upper set of clips for down rod with rubber bush (garari) including set of nut bolts and washer, pin complete all as specified and directed. | 20 | Each | 25 ₹500 Lowest | 25 ₹500 Lowest |
| 9.00 | S&F in replacement rubber bush (garari) for mounting at upper side of down rod clip complete all as specified and directed | 50 | Each | 10 ₹500 Lowest | 10 ₹500 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
5 Mar 2026, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
COMPREHENSIVE MAINTENANCE OF INTERNAL WIRING AND ALLIED ITEMS IN MD ACCN AT SI LINES UNDER GE BHOPAL
2026_MES_752369_1
8535/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹60,000
Yes
19 May 2026
12 Feb 2026
7 Mar 2026
12 Feb 2026
5 Mar 2026
26 Feb 2026
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Dismantling of ceiling fans AC single phase 230 volts of sizes 1200mm/1400mm any make / model except old vintage, dismantling its stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws etc as required and reassembling and depositing the repaired fan to MES fan store after testing complete all as specified and directed.
All as per item No.1.00 here-in-before but exhaust fan, 300/380 mm sweep, AC single phase, 230/240 volts complete all as specified and directed.
All as per item No.1.00 here-in-before but exhaust fan, 230/250 mm sweep, AC single phase, 230/240 volts complete all as specified and directed.
All as per item No. 1.00 here-in-before but wall / pedestal fan, of any sweep and capacity complete all as specified and directed.
Note: - for items No 1 to 4. (i) The quoted rate deems to include for all minor expenses required for making the complaint functional. (ii) Repairing/ rewinding of ceilling fan/ exhaust fan shall be carried out in the SI Line E/M yard in present of concern JE E/M and winding wire sample produced for sample before star work (iii) Space/room will be provided by AGE E/M in the E/M yard for carring out repair work. (iv) Contractor staff will collect defective fans from concern JE E/M, check the fans after opening it, and intimate the defects in the fan to JE E/M before carring out the repairs. (v) The bearing of fan should be of NBC/SKF/FAG make only. No other make will be accepted.
Supply and fix in replacement of LED slim square/circular panel light fitting for surface ceiling light 12 watt, colour warm white including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed.
S&F in replacement condenser carrier clip (PVC) in build connector two way fixed with screw on down rod or housing complete all as specified and directed.
S&F in replacement upper set of clips for down rod with rubber bush (garari) including set of nut bolts and washer, pin complete all as specified and directed.
S&F in replacement rubber bush (garari) for mounting at upper side of down rod clip complete all as specified and directed
S&F in replacement gun metal bush self lubricated, any size, suitable for ceiling and wall fans complete all as specified and directed
S&F in replacement flexible copper conductor stranded 1100 Volt PVC insulated cable three core 23/0.0076 size complete all as specified and directed.
S&F in replacement Fan condenser 2.5 mfd, 230 volts complete all as specified and directed.
S&F in replacement Fan condenser 3.15 mfd, 230 volts complete all as specified and directed.
Supply only the following items for fixing against defective parts of fan taking down under item No 1.0 here in before complete all as specified and directed.
(a) Bearing No 6201'ZZ'
(b) Bearing No 6202'ZZ'
(c) Bearing No 6203'ZZ'
(d) Bearing No 6204'ZZ'
Taking down ceiling / wall fan from fan hook and disconnection from ceiling rose, dismantling of fan parts i e. down rod and connector/condenser, nut bolts, split pins, rubber bush (garari), condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
Taking down exhaust fan and disconnection from ceiling rose, dismantling of fan parts i e. connector/ condenser, nut bolts, condenser carrier clip (PVC), in build connector two way, etc complete servicing by cleaning greasing/oiling in side surface of rotar by CTC with sand paper and repair and re - fitting / reassembling and making the fan fuctional and fixing the fan in position and testing complete all as specified and directed. Note: - Only rubber packing (garari) condenser, condenser carrier clip (PVC) in build connector two way shall be measured and paid separately.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 300 mm long 19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement down rod for ceiling fans duly painted with synthetic enameled paint 600 mm long19 mm outer dia with holes on both ends of the rod for connection wire replacement complete all as specified and directed.
S&F in replacement exhaust fan metal blade duly powder coated suitable for 300 mm/230mm sweep as per existing complete all as specified and directed.
S&F in repairs blade assembly of celling fan of 1200 mm sweep (set of three) of make, colour and pattern as per existing complete all as specified and directed.
S&F in repairs top and bottom canopy of ceiling fan(any sweep) of make , colour and pattern as per existing model all as specified and directed
S&F in repairs outer frame complete with clamps, rubber packing, nut bolts etc & all accessories duly painted suitable for 230 mm /300 mm sweep exhaust fans complete all as specified and directed.
S&F ceiling fan regulator switch/socket type electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and as directed.
Dismantling of cabin fan of any sweep and overhauling by means of cleaning of stator, oiling & greasing including replacement of nut and bolt, etc and reassembling, re-fixing and testing the fan complete all as specification and directed.
Taking down unservicable sub main wiring including service connections, of any size and any description including conduit pipe and making good disturbed surface of walls/ ceiling to match with existing surface complete all as specified and directed .
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i) Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
Taking down carefully existing point wiring (any type viz. aluminum or copper) with wooden batten/surface PVC conduit (with its fittings)/PVC casing-capping or any other type for light, fan, power point (including switch, socket, ceiling rose, etc.) and making good disturbed surface of wall/ceiling to match with existing surface after necessary rewiring complete.
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FRLS H cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates)
All as per ser item No. 29.00 here-in-before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
All as per ser item No. 29.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
All as per ser item No. 29.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.complete all as specified and directed.
All as per ser item No. 29.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.complete all as specified and directed.
M&L for casing caping/conduit point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and includidng single core PVC insulated unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LSH cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed (Note cost of cutting chase and making good shall be included in the quated rates)
All as per ser item No 34.00 here-in-before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed.
All as per ser item No 34.00 here-in-before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
All as per ser item No 34.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.complete all as specified and directed.
All as per ser item No 34.00 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4.0 Sqmm and 4.0 Sqmm as earth wire.complete all as specified and directed.
S&F in replacement building security light fitting luminaire of 36 watt LED system efficacy not less than 110 lm per watt, type pressure die cast aluminium housing and heat resistant toughened glass with frame protection IP-66 suitable for voltage range should be 170 to 240 Volts,CCT >= 5700K, 4kv inbuilt and 10 kv external surge protection and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with three core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 volt AC, ISI marked complete all as specified and as directed.
S&F socket outlet multipurpose 2 in 1 having provision for 3 pin, 6 Amp piano, flush type, 230 volt AC complete all as specified and as directed.
S&F switch socket combination, multipurpose, 3 pin, 5-15 Amp, flush type including PVC gang box, ISI marked complete all as specified and as directed.
M&L geyser of 25 ltrs capacity of cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution mixed with water in suitable proportion till the complete deposits/scale is removed and approved by the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks, fixing the serviceable parts in position, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting, fixing & installation of the geyser in position including dismantling old geyser of any description complete all as specified and directed. NOTE:-(i) De-scaling chemical shall be concentrated HCL of make as approved by GE. (ii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of schedule. (iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool and additional quantity of glass wool for insulation, if any required, is deemed to be included in the quoted unit rate. (v) Spares as required shall be measured and paid seperately.
All as per Item Sl No. 43.00 above but geyser of capacity 50 Ltrs .complete all as specified and directed.
S&F 1.5 KW capacity heating element (ISI marked) round type/thread/triangle / push/ screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F 2.0 KW capacity heating element (ISI marked) round type/thread/triangle/ Push/ Screw base type with ‘O’ ring including making electrical connection complete all as specified and directed.
S&F electronic heating element (ISI marked) fitted with auto cut thermostat 1.5/2.0 KW suitable for 25/50 ltr geyser including making electrical connection complete all as specified and directed.
S&F in replacement geyser assembly suitable for 25 ltr capacity, ISI marked as per existing complete all as specified & directed.
S&F in replacement geyser assembly suitable for 50 ltr capacity, ISI marked as per existing complete all as specified & directed.
S&F in replacement thermostat suitable for 25/50 Ltr geyser ISI marked with setting range 30 C to 80 C suitable for 230 volts AC electric supply complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 25 Ltr geyser complete all as specified & directed.
S&F in replacement inner tank made of stainless steel suitable for 50 Ltr geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement outer tank made of steel duly powder coated suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 25 Ltr Geyser complete all as specified & directed.
S&F in replacement bottom cover suitable for 50 Ltr Geyser complete all as specified & directed.
S&F in replacement Indicating lamp (set of two) 230 volts 50 HZ AC suitable for geyser any type (round, square or rectangular type) any capacity complete all as specified and as directed.
S&F in replacement single pole and neutral sheet metal enclosure with two pin and earth, plug and socket, IP 43 ,suitable for single phase 240 V, complete with and including one single pole MCB of capacity 20 amps having `C` charactristic, breaking capacity 10 KA, and including industial plug top complete all as specified and as directed.
S&F in replacemnt PVC connections 15 mm size nylon braided, heavy duty, 600 mm long ISI marked including rubber washers (suitable for hot water) complete all as specified & directed.
S&F in replacement pressure release valve suitable for 25/50 Ltr capacity geyser complete all as specified & directed.
S&F in replacement PVC insulated multistranded copper conductor, 3 core of size 2.5 Sqmm, 1100 volts grade complete all as specified & directed.
S&F in replacement LED decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2 feet, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed.
S&F in replacement warm white LED decorative aluminium casted edge ceiling light, recess mounting LED 2 x 2 feet, luminaire 36 watt with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm two core complete all as specified & directed.
Supply and fix in replacement coral post top lantern fitting 25 Watt, IP 65, energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories all as specified and directed by Engineer in charge.
S&F in replacement LED tube light complete fitting , surface mounted luminanaires, 20 watt, 240V, decorative ultra slimround/square profile LED lighting fixture with extruded polycarbonate body, environmental friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F in replacement of warm white LED tube light fitting two feet 10 watt, slim design, 230 volts, including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 1.5 Sqmm AC 230 V complete all as specified and directed.
S&F PVC insulated unsheathed, ISI marked FRLS copper cable, 2.5 Sqmm AC 230 V complete all as specified and directed.
S & F modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S & F modular switch, one way, 16 Amp, one module, 240 volts complete all as specified and directed.
S & F modular bell push switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F modular socket outlet 2-in-1, 5pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
Supply and fixing modular switch socket combination, multipurpose 6 pin, 16 amp, 3 module complete all as specified and directed.
Supply and fixing modular fan regulator, 5 stepped, high speed complete all as specified and directed.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including MCCB/MCB and wooden boards complete all as specified and directed.
S&F sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. NOTE:- MCB shall be measured and paid seperatly.
Supply and fixing factory made epoxy powder coated Distribution Board TPN, 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-54 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperatly.
S&F sheet metal enclosure double door type surface mounted concealed in wall 8 ways, 240 Volts, IP 43 ISI marked 200 amps bus bar dust and vermin proof ( IP-54 protection )suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F sheet metal enclosure double door type surface mounted concealed in wall 12 ways, 240 Volts, ISI marked 200 amps bus bar dust and vermin proof IP-54 ,suitable for incorporation MCBs and isolators etc complete all as specified and directed. NOTE:- MCB shall be measured and paid separately.
S&F MCCB 160 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed.
S&F in repairs MCB, SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 6 to 32 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB, SP, 240 volts, 10 KA breaking capacity, 'B' curve, of capacity 40 amps including connection with suitable size aluminium / copper lugs complete all as specified and directed.
S&F in repairs MCB, SPN suitable for 240 volts, 'B' curve,AC supply 6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
S & F in repairs MCB, SPN suitable for 240 volts, 'B' curve, AC supply 40 to 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB, TPN suitable for 240 volts, 'B' curve,AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S & F in repairs MCB, TPN suitable for 240 volts, 'B' curve,AC supply 100 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement 3 pin plug top, AC-230 V, 15 Amp,ISI marked complete all as specified and directed.
Supply & fixing in replacement recess mounting spot LED light round downlighter designed with excellent thermally managed luminaire 12 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size Make:- Cart Part No - SPARKLEPROADJDLR8W830MOD40DWHTNEEM of Havells or equivalent Bajaj/C & G.
Supply & fixing Flexible LED strip IP-43, uses high brightness SMD LED as the light source for indoor application only, luminaire 24 watt, 220V AC with high efficiency light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with three core flexible coppder conductor cases of suitable size Make:- Havells Cart Part No LHEHDLPFUN1W024 (Flexion Neo Led Strip 24 W of any colour).
M&L for supply Installation testing commissioning of IP-65 flexion tri coloured LED strip rope light of 120 LED/mtr and with all necessery accessories rated Input power : 8 W Per meter , LED Driver : AC Adapter, Input voltage Rated voltage: - 220V-240V AC, Working Voltage Range:- 100-300 VAC,Supply frequency 50/60Hz, Power factor >0.9, Protections Open Circuit, LED reverse polarity, surge withstanding 2.0KV, CCT 3000K/4000K/6500K, temperature : 0 to 50°C high quality of lighting color consistency but also protect products outdoor against from harsh environments outdoors, It’s can be used for decoration lighting and guidance lighting outdoors, delivers good performance of lightig in tri color complete all as specified & directed.
Supply & fixing in replacement LED decorative wall light,IP65, gold finish fixture with white glass diffuser suitable for 9 W LED bulb E27 base (Gobleto WL 1LS E27 GLD) complete all as specified & directed. Cat part No-LHFOAKD1TZ1D060 of Havells or equivalent make.
Supply & fixing in replacement LED garden light (BAMBOO LED BOLLARD) new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source complete all as specified & directed. Cat part No-BAMBOOBLS8WLED830PSYMTOPC of Havells or equivqlent Bajaj / C&G.
Supply & fixing in replacement curved 6 watt LED warm white adjustable multiple angle mirror Light including inbuilt LED driver new generation, energy saving, environmental friendly, long life aesthetically designed for diffused lighting with high power LED as light source complete all as specified & directed.
Supply & fixing in replacement 3 watt LED warm white rotate in 360 degree angle Bed Side Light including inbuilt LED driver energy saving, environmental friendly, long life aesthetically designed aluminium landscape for diffused lighting with high power LED as light source complete all as specified & directed. Make - Cart Part No - 48042 of Philips or equivalent Bajaj / C&G complete all as specified and directed by Engineer in charge
S&F non metallic rigid PVC casing and caping ISI marked of 20mm size medium grade , complete all as specified and directed.
S&F non metalic PVC conduit ISI marked of size 20mm dia medium grade ,complete all as specified and directed.
M & L for chemical earthing with earth electrode made of low carbon steel circular rods, molecularly bonded with copper on outer with minimum thickness of 250 micron, 17 mm dia, 3 metre long including drilling of bore hole of 150 mm dia of 20 metre depth, filling the bore hole with black cotton soil up to 17 metres level i.e. below the electrode bottom level, placing electrode by penetrating 150 mm into black cotton soil, filling earth enhancement material (minimum approx. 30 kg) into the augured hole in slurry form and allowed to set, minimum 125 mm dia covering of the composite structure (earth electrode + earth enhancement material), covering remaining portion with backfill soil/ material, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth electrode, to test point upto 7.5 metre & construction earth pit including testing complete all as specified and as directed.
S&F in repairs laminated hylem sheet cover, ISI marked of Make" Hylem" including cutting grooves for mounting of fittings like switches, sockets, fan regulators etc; including fixing in location with new galvanised screws and cup washer complete all as specified and directed of following sizes:-
(a) 11 x 13 inches
(b) 9 x 11 inches
(c) 5 x 8 inches
(d) 5 x 5 inches
Deduct Schedule of credit (calculation will be done off line) Rs. 25563.00
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_842686.xls
BOQ • 0.34 MB
TENDER_DOCU_8535.pdf
Tender Documents • 0.78 MB
CREDIT8535.pdf
Additional Documents • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .