Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.1 L
Closing Date
27 Mar 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
14 conditions · 2 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Technical Eligibility Criteria: (a) The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity.
Defination of Similar Work :- Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC Gate or Yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HA-SSDAC) or Automatic signaling.
7 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
TENDER FORM (First Sheet) Annexure-I
ANNEXURE-V
ANNEXURE V-A
Annexure-VIB
Audited Balance Sheets duly certified by the Charted Accountant along with Annexure VI-B
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Provision of shunting neck at Ariyalur station by extending the overrun line at road No.6 at VRI end.
T-SG-36-I-41-2025-2026
T-SG-36-I-41-2025-2026
Open
Works - General
9 Months
Chennai, Tamil Nadu
₹0
₹2.1 L
27 Mar 2026
3 Mar 2026
13 Mar 2026
69 items across 1 schedule · ₹60,32,437.54 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 100.00 | 382.12 | 38,212 |
| 2 | Designing o f Signalling plan i n AUTOCAD 2000 or latest a n d submission o f negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 s e t s of prints s h a l l b e supplied t o Railways for checking. One set will b e returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall b e supplied to Railways on 80/90 gsm tracing paper and 2 CDs.[2 interlocked sidings will be considered equal for one loop line](Approved permanent w a y p l a n w i l l be supplied by Railways).b)Designing of Signalling plan in AUTO CADD - 'U' size - for stations from 5 to 8 roads | Station | 1.00 | 17,147.65 | 17,147.65 |
| 3 | Designing o f circuits diagrams/ table of control in AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and a l s o t h e s o f t c o p y i n compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will b e returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied t o Railways o n 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs.(Approved Signalling plan will be supplied by Railways f o r preparing table o f control. Approved table of control will be supplied by Railways for preparing circuits diagrams).a) D e s i g n i n g of circuits/TC in AUTO CADD 2000 - A3 SIZE | Sheet | 50.00 | 1,089.28 | 54,464 |
| 4 | "Supply and Provision of 64 Input Digital Stack Card (Digital Input Card) to suit Datalogger as per IRS S- 99/2006 amt 3 or latest" | Numbers | 1.00 | 26,458.78 | 26,458.78 |
| 5 | Supply and Provision of 128 input tag block for termination of relay wiring inside Datalogger | Numbers | 1.00 | 7,349.87 | 7,349.87 |
| 6 | Supply a n d Provision o f E u r o R a c k for housing additional cards and Mother Boards of Datalogger | Numbers | 1.00 | 17,247.76 | 17,247.76 |
| 7 | "Supply and Provision o f Housing Rack for Housing Euro Rack, Power arrangement, terminations etc." | Numbers | 1.00 | 18,698.79 | 18,698.79 |
| 8 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 75.00 | 285.86 | 21,439.5 |
| 9 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 10.00 | 285.86 | 2,858.6 |
| 10 | Supply and Provision of indicative type Class D Surge Protection Device for 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of the Engineer in charge at site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make).All o t h e r miscellaneous materials required for installation shall b e supplied b y the contractor. | Numbers | 9.00 | 6,328.8 | 56,959.2 |
| 11 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions of t h e Engineer in charge a t s i t e ( O B O , DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All o t h e r m i s c e l l a n e o u s m a t e r i a l s required for installation shall be supplied by the contractor. | Numbers | 2.00 | 6,830.72 | 13,661.44 |
| 12 | Supply o f e a r t h electrodes ( G I ) a s p e r Drg no SG/CN/02/13 | Numbers | 11.00 | 1,618.75 | 17,806.25 |
| 13 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 11.00 | 1,707.55 | 18,783.05 |
| 14 | Supply o f Low maintenance secondary cells of the following capacities w i t h necessary inspection as p e r specification/ drawing/ description enclosed in this document.b)Supply o f Secondary cells - 2V- 80AH capacity | Numbers | 6.00 | 3,379.2 | 20,275.2 |
| 15 | Supply of 'B type choke IRS:S 65-83 | Numbers | 4.00 | 2,855.6 | 11,422.4 |
| 16 | Supply o f 2 4 C o r e x 1 . 5 S q . m m PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 4000.00 | 388.15 | 15,52,600 |
| 17 | Supply o f 12Cx1.5 SQMM PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 6000.00 | 215.92 | 12,95,520 |
| 18 | "Supply o f 2x2.5 sq.mm P V C insulated Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest" | Metre | 500.00 | 98.76 | 49,380 |
| 19 | Supply o f 3 C x 10SQMM P V C insulated Armoured, unscreened, underground Railway Signalling Aluminium power cable as per as per spec IRS.S.63/2014(Rev.4.0) or latest | Metre | 250.00 | 80.97 | 20,242.5 |
| 20 | Supply o f Underground jelly filled 6 QUAD, 0.9MM Dia as per spec IRS:TC 30-05 with amd 5 or latest | Metre | 1000.00 | 301.05 | 3,01,050 |
| 21 | Supply and provision o f normal joint using Thermo shrink jointing k i t (RDSO specs No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing k i t t o be inspected b y RDSO) f o r 4 / 6 qua d cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e same after completion of cable joint as per the instruction of Railway representative at site. | Numbers | 2.00 | 4,628.91 | 9,257.82 |
| 22 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as p e r t h e instructions o f Railway representative at site.) as per drawing enclosed | Numbers | 75.00 | 262.65 | 19,698.75 |
| 23 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 1500.00 | 64.1 | 96,150 |
| 24 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site after l a y i n g of DWC/RCC pipes. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench s h a l l b e f r o m t h e bottom o f sleepers for track crossings. Laying o f cables a n d DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 50.00 | 385.45 | 19,272.5 |
| 25 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f D W C / R C C p i p e s with couplers/collars is not included in this schedule). | Metre | 20.00 | 501.03 | 10,020.6 |
| 26 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 50.00 | 208.54 | 10,427 |
| 27 | L a y i n g o f signaling/power/ telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre | 9800.00 | 18.18 | 1,78,164 |
| 28 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." | Metre | 1500.00 | 15.4 | 23,100 |
| 29 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting o f concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating i t b y ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits a n d 5 0 Mtrs. outside station limits throughout t h e cable route, diversions and also at every track/road crossing." | Numbers | 75.00 | 123.35 | 9,251.25 |
| 30 | Excavation of cable coil pit t o a size of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 1.00 | 949.05 | 949.05 |
| 31 | "Road crossing/ Track Crossing through Horizontal Drilling at approximately depth of 1.5 to 2 m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DW C pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination as directed b y the site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)" | Metre | 50.00 | 1,351.45 | 67,572.5 |
| 32 | Supply o f subsidiary Signal Aspect - Shunt LED as p e r R D S O Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 3.00 | 5,740.7 | 17,222.1 |
| 33 | Manufacture and supply of Enameled Number plates a s p e r drawing No.TY/08/2008 with fixing arrangements and fixing t h e m o n t h e existing S i g n a l s a s per the instructions of Railway representative at site.[Enameled n u m b e r plates with fixing arrangements with bolts a n d nuts shall be supplied by the Contractor]. | Numbers | 2.00 | 305.25 | 610.5 |
| 34 | Supply of Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 1.00 | 7,463.5 | 7,463.5 |
| 35 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Re l a y ( K L C R ) w i t h one number K-50 neutral Relay to work on 24V DC non AC immunized as per specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with o n e extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 11.00 | 10,722.72 | 1,17,949.92 |
| 36 | Supply of electronic time delay units (120/60 secs) with plug boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 2.00 | 2,742.03 | 5,484.06 |
| 37 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, w i r i n g a n d termination as per approved circuit diagram a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers a n d all other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 5.00 | 4,945.51 | 24,727.55 |
| 38 | Fabrication and Supply of box suitable for 8 Nos of KLCRs | Numbers | 1.00 | 28,143 | 28,143 |
| 39 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 1.00 | 15,009.6 | 15,009.6 |
| 40 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s b a r f o r supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet o f thickness 3mm wherever required. The termination and cable core particulars shall be painted o n the PVC/ nylon sleeves. T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 100.00 | 167.99 | 16,799 |
| 41 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s b a r f o r supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet o f thickness 3mm wherever required. The termination and cable core particulars shall be painted o n the PVC/ nylon sleeves. T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g P B T f u s e b l o c k i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 20.00 | 201.27 | 4,025.4 |
| 42 | Fixing o f plug boards, 5 0 way terminal blocks with 2 B A terminals, a n d wiring of relays a s p e r the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken to provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts for data logger and terminating them in tag blocks, provision of relay index board.(Supply o f relays, plug boards, connectors and retaining clips i s not covered i n this schedule). [Wire P V C 16/0.2mm copper, tag blocks, 2BA terminals, hard wood plank of size 600mmx 900mmx25mm with decolum finish, MS angles of size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, phynolic sheet 6 m m t h i c k o f s i z e 1200mmX1800mm with aluminium grooved channel frame f o r relay index board, paints, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l o t h e r miscellaneous materials required f o r t h e w o r k s h a l l b e supplied by the Contractor]. | Per Relay | 30.00 | 1,045.76 | 31,372.8 |
| 43 | Fixing o f additional plug boards, 5 0 ways terminal blocks a n d wiring o f additional relays a s p e r the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f relays, plug boards, connectors and retaining clips and 5 0 way terminal boards i s n o t covered i n t h i s schedule). [Wire PVC 16/0.2mm c o p p e r , 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, v a r n i s h a n d a l l o t h e r miscellaneousmaterials required f o r t h e w o r k s h a l l be supplied by the Contractor ] | Per Relay | 10.00 | 726.5 | 7,265 |
| 44 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 1 6 / 0 . 2 m m copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Per Relay | 2.00 | 695.67 | 1,391.34 |
| 45 | Supply o f C a b l e Ro u t e Tr a c e r a s per Technical specification | Numbers | 1.00 | 5,78,788.99 | 5,78,788.99 |
| 46 | Supply of Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification N o . IS 14930(Part 2 ) : 2 0 0 1 w ith one coupler for every 6 m o f p i p e a s p e r Technical specification | Metre | 120.00 | 365.19 | 43,822.8 |
| 47 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 50.00 | 1,119.16 | 55,958 |
| 48 | Supply of High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 M e t e r s a s per specification N o . I S 4984: 2016 w i t h latest amendments and Material Grade:PE 80 | Metre | 700.00 | 853.55 | 5,97,485 |
| 49 | Supply of Electronic Cable Route Marker 3M make or similar, Model: RFID (1421) and installation, cable detection of capacity to detect the cable upto 5 feet depth. | Numbers | 75.00 | 2,441.72 | 1,83,129 |
| 50 | Supply o f PBT terminals 25mm/ 60mm centre and P B T Fuse blocks with necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 250.00 | 61.44 | 15,360 |
| 51 | Supply o f PBT terminals 25mm/ 60mm centre and P B T Fuse blocks with necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 100.00 | 93.02 | 9,302 |
| 52 | Supply o f PBT terminals 25mm/ 60mm centre and P B T Fuse blocks with necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 50.00 | 103.84 | 5,192 |
| 53 | Supply and installation of yard layout diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fine weave cotton fibre board (matt finish) 6 m m thick size 1800mm X 1200mm w ith aluminium channel frame. The yard layout shall be neatly painted and fi x e d a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 16,722.15 | 16,722.15 |
| 54 | S u p p l y o f magneto telephone h a n d l e type and supply of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC | Numbers | 2.00 | 8,106.7 | 16,213.4 |
| 55 | "Excavation o f pit and casting concrete foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f s i z e 20/25mm a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 1.00 | 4,645.17 | 4,645.17 |
| 56 | "Erection o f Ground t y p e s h u n t signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing o f lens guards, number plate, termination of tail cables, wiring o f signal u n i t w i t h P V C wire 3/0.75mm coppe r, provision o f E W S locks and painting of one coat o f red oxide and two coats of Aluminium/ enamel paint.(Supply o f Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covere d i n t h i s schedule).[Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts a n d nuts, lead wool, paints and all other miscellaneous materials shall b e supplied by the Contractor]." | Numbers | 1.00 | 3,170.44 | 3,170.44 |
| 57 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 2.00 | 8,914.5 | 17,829 |
| 58 | Excavation o f pit, casting concrete foundation and erection o f apparatus case full s i z e a s p e r Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & n u t s , ' E ' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fi x i n g b o l t s & n u t s a n d a l l other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers | 1.00 | 11,333.1 | 11,333.1 |
| 59 | "Excavation of pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required for the work shall be supplied by the Contractor]""" | Numbers | 8.00 | 8,787.04 | 70,296.32 |
| 60 | Termination of new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ C T boxes/ cable termination racks a s per approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n t h e d o o r s of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w ork includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing t h e bottom o f t h e apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 100.00 | 73.59 | 7,359 |
| 61 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks on t h e terminal b o a r d , drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso o n the inner side o f t h e doors of apparatus cases. After terminations are "over, t h e s i d e o p e n i n g s of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination o n 2 5 / 6 0 m m PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 350.00 | 172.14 | 60,249 |
| 62 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks on t h e terminal b o a r d , drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves andalso o n the inner side o f t h e doors of apparatus cases. After terminations are "over, t h e s i d e o p e n i n g s of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 50.00 | 209.93 | 10,496.5 |
| 63 | Termination o f m a i n , t a i l , Signaling and power c a b l e s a n d internal w i r i n g b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n t e a k w o o d b a s e plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram and cable plan, painting o f particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. a)Termination o f cables o n 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 50.00 | 151.09 | 7,554.5 |
| 64 | Termination o f m a i n , t a i l , Signaling and power c a b l e s a n d internal w i r i n g b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n t e a k w o o d b a s e plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram and cable plan, painting o f particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with M sand u p t o base level a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. b)Termination o f cables o n P B T fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 20.00 | 188.86 | 3,777.2 |
| 65 | Installation of charged secondary cells of the following capacities i n apparatus cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule). [Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit | 6.00 | 491.59 | 2,949.54 |
| 66 | Installation of magneto telephones with Nicad pack | Numbers | 2.00 | 3,322.6 | 6,645.2 |
| 67 | Transportation of Signalling materials by road as per t h e instructions o f Railway representative a t site. The work also includes loading and unloading of the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 100.00 | 22.75 | 2,275 |
| 68 | Transportation o f Signalling materials more than 100km | MT-Km | 500.00 | 13.91 | 6,955 |
| 69 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and a s p e r t h e instruction of Railway representative at site. | Hour | 10.00 | 1,202.5 | 12,025 |
| Schedule total | ₹60,32,437.54 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
LetterofCreditRBLr_1.pdf
ATTACHMENT
ProcedureforundertakingdiggingworkinvicinityofSignalingElectricalandTelecomcables.pdf
ATTACHMENT
41-TD-ShuntingALU.pdf
ATTACHMENT
NITCPROIADSNFOB_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .