| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹18.5 L+₹2.2 L (13.5%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹22.2 L+₹5.9 L (36.3%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
7 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
PROVN OF CERTAIN SACTIONED WORKS AT AF STN JAISALMER, RAMGARH AND CHANDAN UNDER GE (AF) JAISALMER
2020_MES_376323_2
8691/GE/E8
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
180 days
GE (AF) Jaisalmer
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹32,000
Yes
5 Dec 2020
8 Oct 2020
9 Nov 2020
8 Oct 2020
7 Nov 2020
20 Oct 2020
60 days
Amount
Rough excavation not exceeding 1.50m deep and getting out any type of locally available soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells cesspits, manholes, pier holes etc or not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells cesspits, menholes, pier holes, laying of cables & CI/GI pipes lines etc not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out soft/disintegrated rock complete all as specified.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out any type of soil.
Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface in soft/ loose soil.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Removal of excavated rock/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Removal of excavated rock/ material to a distance exceeding 250 metre but not exceeding 500 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
M&L for Hardcore of guage not exceeding 63mm deposited spread and leveled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified.
M&L for plain cement concrete (1:4:8) Type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for Plain cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in cill, steps, and for inserting hold fast of door and window, plinth cources, parapets, copings and like including weathering slightly rounded or chamfered angles and throating, necessary formwork as required etc complete all as specified.
M&L for precast cement concrete (1:3:6), type C-1 (using 20 mm graded stone aggregate) solid block masonary exceeding 10cm and set in cement and sand mortar (1:6), complete all as specified and directed.
M&L for providing cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping, plinth courses, kneelers, apex, stones, bed plates, water through, kerbs and the likes including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:2:4) Type B-1 (using 20 mm graded stone aggregate) as in surface channels and drains and benching to manholes complete all as specified and directed.
M&L for plain cement concrete (1:2:4) Type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L precast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes, chajjahs water troughs, mangers, shelves and similar articles with plain faces including use and waste of form work and and set in cement and sand mortar (1:6) complete all as specified & directed.
M&L for broken stone or boulder loose filling with aggregates of gauge 40 to 80mm in grease trap complete all as specified and directed.
M&L for reinforced cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub bases of floor or hard standing and finished even and fair surfaces complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in floor, sub bases of floor and finished even and fair surfaces complete all as specified and directed.
M&L for M-35 grade 60mm thick grey cement with pigment machine pressed factory made precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 with and including 25mm thick compacted thickness of sand bedding laid to required level & slope complete all as specified and directed
M&L hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Gde E-165 (Fe-290) complete all as specified and directed.
S&F mild steel work in framed work such as grills, gratings, framed guard bars, barred iron doors etc. with ends of bars shouldered and/ or riveted, or forged into spikes, and in ladders, railings, frame of water tank etc.and similar work confirming to Fe- 290 Grade E-165 for framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed.
S&F mild steel for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, conforming to Grade E-165 (Fe-290), drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete including necessary welding etc and fixing in position complete all as specified.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as directed.
S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc as directed. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
S&F galvanised steel Concertina coil with punched tape concertina coil 1050mm diameter (when coil unstretched) and fixed to iron angle post/strusts with necessary bolts with angle iron and GI staples, concertina coil of core wire diameter 3.15mm, complete all as specified and directed.
Cutting holes in any type of masonary built in cement mortor for inserting hold fasts and making good dismantled portion in cement concrete (1:2:4) type B-1 etc complete all as directed.
M&L for 10mm thick plaster in cement (1:4) on fair face of concrete surfaces or stone masonry surfaces of wall finished even and smotth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement and mortar (1:4) on fair faces of stone masonry or concrete surfaces with using water proofing compound at the rate of minimum 3% by weight of cement and as per manufactures instructions, finishing even and fair complete all as specified. Note : Water proofing compound shall be measured and paid separately at supply only rates.
M&L for 15mm thick plaster in cement (1:4) on stone masonary surface on other than fair face of brick work or concrete surfaces or stone masonry surfaces of wall and including taking down cement plaster of any description on any surfaces complete all as specified.
Supply only integral water proofing compound (ISI marked).
M&L for preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper of approved tint over a coat of alkali resistant priming paint complete all as specified.
M&L for preparation of newly plastered or unplastered of wall surfaces and applying two coats of cement based paint of different tints of approved complete all as specified and directed by Engr-in-charge.
M&L for prepariation of newly or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of newly plastered and unplastered surface of walls and applying three coats of white wash complete all as specified and directed.
S&F coloured glazed ceramic tiles 300mm x 200mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement and sand mortar (1:4) and including dismantling of floor, hearth or wall tiling stone partitions including cement mortar bedding complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified.
S&F anodised aluminium extruded sections as in frames for doors, windows, ventilators, grills, partitions with one or more rebates including necessary joining cleats, glazing clips complete all as specified and directed.
Dismantling of aluminium anodised snap grid work with suspenders as in false ceiling complete all as specified.
Dismantling/taking down of linoleum sheets in floors fixed with adhesive etc complete all as specified.
S&F solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given in SSR.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make to make PVC frame as per specification complete all as specified and directed.
S&F Anodized aluminium sections as in window and ventilator shutters, side hung type without sash bars (aluminium sections weighing 0.55 kg/m) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (01 Nos each shutter), extruded anodised aluminium alloy with galvanised mild steel hinge pin, 100mm long (03 Nos each shutter), extruded anodised handle of suitable type (01 No. each shutter) etc. complete all as specified and as directed.
S&F anodized aluminium snap grid frame work using corner angle, main and cross 'T' of sizes as specified for false ceiling fixed with hangers of 6mm dia GI (upto 1200mm length) adjusing level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long complete all as specified & as directed.
M&L for 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60ommx 600mm in size, fixed with screws to iron frame work in ceiling, fixed in ceiling, flat or sloping complete all as specified & as directed.
M&L for 2mm thick linoleum plain coloured fixed with approved adhesive in floors including stretching, cutting and fitting last two items if linoleum is sealed down with an approved adhesive etc complete all as specified & as directed.
S&F 5mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
S&F 100mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors complete all as specified.
S&F 100mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed to walls complete all as specified.
S&F 75mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or floors complete all as specified.
S&F 75mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, fixed to walls complete all as specified.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & as directed.
S&F 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & as directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for 150mm bore drain pipes for bed concrete including cradles the sides of pipe after they are laid and tested complete all as specified and as directed.
M&L for 150mm bore reinforced concrete pipe, class NP2, laid and jointed complete with collars complete all as specified & as directed.
S&F cast iron floor trap of 75mm bore, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified & as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surface of concrete flat surface complete all as specified.
M&L for machine cut kota stone flooring 20-25mm thick laid in floors in squares or rectangular pattern over and including 15mm thick cement screed bed in cement and sand mortar (1:6) set and jointed neat cement slurry and pointed in coloured cement to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for 20mm thick black granite slab/ tiles in floors/treads etc, set & jointed with neat cement slurry over and including 15mm thick screed bed in cement mortar (1:6) and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) complete all as specified and as directed.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and complete to walls and ceiling or laid in floors, complete all as specified and directed.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and complete to walls and ceiling or laid in floors, complete all as specified and directed.
S&F Sink tap 15mm bore, fancy type, cast copper alloy, chromium plated, long body fancy type, with crutch or butter fly handle screwed down or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified.
S&F 20mm bore Gun-metal globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified.
S&F stainless steel sink size 750x450x250mm sinks kitchen or laboratory with plugs, washers and wastes; including beding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipes upto 0.50 sqm each complete all as specified.
M&L for construction of soakage wells exc in any type of soil/rock, foundation in PCC 1:3:6 walls of honey combed solid masonry, with top ring of RCC slab including made of brick masonry in cement mortar, RCC cover slab, interconnecting pipes and filling with brick bats complete of size 3.60m dia x 4.50m effective deep complete all as shown in TD Drg No CEAA/TD/80 sheet No 1/2 to 2/2.
M&L for dry sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
M&L for stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles complete all as specified and directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks, three layered, white coloured (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position, including 20mm bore PVC ball valve, high pressure with polythene float and flynut etc complete all as specified.
S&F Bib tap cast copper alloy, chromium plated with crutch or butter fly handle screwed down, screwed for iron pipe or for brass ferrule of 15mm bore complete all as specified
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and complete to walls and ceiling or laid in floors, complete all as specified and directed.
Supply and fixing of LT Panel, double door, outdoor type mounted on pedestal factory made, totally enclosed with necessary ventilation weather, dust and vermin proof (also to confirm IP-54 standard) front and rear opening and locking arrangement made of MS angle iron frame work the panel shall be suitable for incoming MCB of 40 Amp SPN and outgoing of 6 Nos, 6 to 32 Amp MCB, 240 volts complete all as specified. Incoming MCB 40 Amp, SPN, 240 Volts, repturing capacity 10 kA, ‘C’ Curve, Make : Legrand/Siemens/C&S - 01 No Outgoing MCB, 6 to 32 Amps, SP, 240 Volts, repturing capacity 10 kA, ‘C’ Curve, Make : Legrand/Siemens/C&S - 06 Nos
Supply, installation, commissioning and testing of tripode ring earthing system to construct earthing of resistance not more than 01 ohm mainly consisting of 250 micron pure copper high tensile low carbon steel rod earth electrode of minimum 3.0m length, 50mm dia with copper strip of size 20x3.15mm for inter connection to earth electrode and for connected to equipment as per required length, with set of steel nut and bolts, earth enhancement material of mainly consisting of Jamfill compound 50 kg (25 x 2 bags in each pit) jam fill to provide maximum contact between the electrode and jam fill compound. Back fill compound. Jam fill compound shall be eco friendly having CPRI certification, Earthing shall be maintenance free and does not require regular manual addition of water and PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) earth chamber and Earth Pit cover 300 x 300mm. Make: JMV earthing/Daksh Power Solutions/Ashlok. Note: (i) Copper strip of size 20x3.15mm required to connect the electrode shall be passed through GI pipe of suitable size. (ii) Copper strip beyond earth test point shall be mearued and paid for seperately. (iii) Quoted rate deemed to included the cost of excavation and earth work, PCC pit, funnel and cover etc.
M&L for point wiring for one light point controlled by one, one way 5 Amp switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 1.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed by Engineer-in-Charge.
All as per serial item No. 81.00 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 81.00 here-in-before but for one 3 Pine, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board.
All as per serial item No. 81.00 here-in-before but for one 3 Pine, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on same board.
M&L for point wiring for one light point controlled by one, one way 15/16 Amp switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including including providing new 3 mm thick plastic laminated sheet cover (Hylem) and including taking down old unserviceable point wiring complete all as specified and directed. Note : (i) Unit rates quoted by contractor shall be deemed to included for cutting chases in walls, ceilings and making good surfaces in cement and sand mortar (1:3) and finishing the surfaces to match with existing surfaces. (Make : Hylem/Anchor/Formica including machine screws and washer etc for fixing switches sockets etc including 2.5 sqmm copper conductor, standard (green colour earth), PVC insulated unsheathed earth wire to commen earth and connected to earth dolly as specified and directed by Engineer-in-Charge.
S&F in replacement of Modular switch 6 Amps, 250 Volt, AC, one way, one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 00 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular switch 16/20 Amps, 250 Volt, Single Pole, AC, one way with indicator one module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5720 63 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular Socket shuttered, 6 Amps, 250 volts, 2/3 Pin combined, Single Pole, universal India two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 70 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F in replacement of Modular Socket shuttered, 6/16 Amps, 250 volts, 3 Pin combined, Single Pole, Indian two module (ISI Marked) complete all as specified. Make : Legrand (Arteor) Cat Part No 5734 71 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Metal flush mounting box of 3 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 08 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Metal flush mounting box of 4 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 09 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Metal flush mounting box of 6 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 10 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F Modular Metal flush mounting box of 8 Module complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 6890 42 or equivalent in Schneider (Opale)/Anchor(Ave).
S&F white colour modular blanking plate, one module blank complete all as specified and directed. Make : Legrand (Arteor) Cat Part No 5736 49 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 3 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 20 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 4 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 30 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 6 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 40 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing white colour plates with frame for modular switch of 8 module complete all as specified and as directed. Make : Legrand (Arteor) Cat Part No 5757 50 or equivalent in Schneider (Opale)/Anchor(Ave).
Supply and fixing modular fan step regulator, 120 Watts - 2 module, flush type and connecting up, ISI marked, 240 Volts complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65mmx17.5mm with two or three terminal PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified.
S&F in replacement of MCB, 6 to 32 Amp, Single Pole, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4085 95 or equivallent
S&F in replacement of MCB, 10 to 40 Amp, Single Pole with Neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 18 or equivallent.
S&F in replacement of MCB, 40 to 63 Amp, Single Pole with Neutral, 240 Volt, repturing capacity 10 kA, ‘C’ Curve, complete all as specified. Make : Legrand Cat Part No. 4086 20 or equivallent.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 240 Volts, 8 way, SPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard/Legrand/Indoasian/Siemens/Schneider.
S&F in replacement of Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amps rated copper bus bar 415 Volts, 4 way, TPN DB, suitable for fixing MCB as outgoing and MCCB Triple Pole 100 Amp, rupturing capacity 25 kA as main incoming duly painted including fixing of lugs in main incoming and outgoing line and fixing of cable glands of suitable size including grouting the same in wall by means of nut bolts, angle iron and making good distrurbed surfaces complete all as specified and directed. Make : Standard Cat Part No DSDNTHODIW04 equivalent in Legrand/Indoasian/ Siemens/Schneider.
M&L for Sub main wiring with 2x4.00 sqmm, single core, PVC insulated unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) 1100 volts grade conforming to IS 694 including and 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke (FRLS) cable 1100 Volt grade as continuous earth wire in green colour including drawn through in 25mm dia PVC conduit including taking down old unserviceable submain wiring complete all as specified and directed. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and one run 25mm dia PVC conduit shall be measured & paid as one unit.
M&L in replacement of Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground level complete all as specified and directed.
S&F in replacement surface and wall mounted LED tube light fittings of capacity 20 watt, robust and high performance batten, basic all purpose surface and wall mounted LED batten with luminaire comprises of extruded channel in thermally conductive material. High translucent serrated milky white diffuser to get glare free and smooth light distribution efficacy 100 lumen/watt complete all as specified and directed by Engineer-in-Charge. Make : Cromton Greaves Cat Part No. LDL-20W-CDL or equivallent in Havells/CG Philips/GE
S&F in replacement of ultra modern designed architectural, LED Recessed full open 2X2 Tile, Glare free uniform illumination with longer life and less maintenance, luminaire of capacity 36 watt which provides soft-light and suitable for armstrong/grid ceiling complete all as specified and directed. Make : Crompton Greaves Cat Part No. LCTLRNE-36-FO-CDL or equivallent in Philips/GE/Havells.
S&F capacity 20 Amp, metal clad box with top plug and socket, including 20 Amp, MCB SPN complete all as specified and directed by Engr-in-Charge. Make Siemens Cat Part No. 8GB0501RC and equivalent Havells.
S&F MCCB, 3 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed. Make : Legrand Cat Part No. 4200 05 or Havells/Siemens/ABB.
S&F Cable tray 6" wide and 3mm thick including nut, bolts, screws complete all as specified and directed.
Supply, and installation, hi wall Split type Air conditioning unit indoor/outdoor, electric driven single phase of capacity 1.5 TR (5 Star EER) complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality and connecting up all as per manufacturer’s instructions & as directed. Note:- Cost of cutting chases/cutting holes etc in walls/floors including making good in cement mortar 1:4 and other necessary arrangement for fixing indoor & outdoor unit & other minor extras shall be deemed included in quoted rate of this item
Supply and fixing Voltage stabilizer for automatic operation single phase naturally air cooled indoor type copper wound and designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of ± 2.5% of capacity 5 KVA with mounting bracket with time delay relay complete all as specified and directed.
Nitin Enterprises
M/s Fateh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .