RequiredExperience with Government
RequiredAnnual Turnover
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Inverter With Sine Wave Output ( 16 pieces ) Technical Specifications * As per GeM Category Specification 1/4 Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Inverter Governing specification Generally conforming to IS:13314 * Rating in KVA & Min. VAH Capacity of Battery 1 KVA/4320 VAH 1 KVA/4320 VAH Technology IGBT-PWM MOSFET-PWM
RequiredIGBT- PWM Energy Star Rating 4 Star 3 Star
Required4 Star
Required5 Star Trolley with trolley with trolley Type of Battery Tubular battery confirming to IS:13369 Tubular battery confirming to IS:13369 Backup time (Minutes) Minimum 180 Minutes * CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 * Trolley Material CRCA Steel * Type of enclosure CRCA Steel * Thickness of sheet for enclosure ( in mm) minimum 1.2 * Inverter shall have by pass facility Yes * FUNCTIONAL Total Harmonic distortion </=5% * Input Single Phase sine wave(120 to 260 V) * Output Single Phase sine wave 230 V * Inverter Efficiency (%) >/=87% * Overload Time (in Minutes) >/=10 * Overload of rated load (in %) >/=10 * PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 * Degree of protection IP 21 * METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in Yes * 2/4 accordance with IS 1248 : 1983 CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes * Climatic test report as per clause 7.10.1 of IS 13314 yes * Type Test Certificate No. - * Name of Lab - * Type Test Certificate date - * Address of Lab - * Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer. Additional Specification Documents