Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.8 L+₹30,540 (0.72%)Rejected-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹43.7 L+₹1.2 L (2.75%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹44.4 L+₹1.9 L (4.49%)Rejected-Finance OPP MARICAR HOSPITAL JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹45.0 L+₹2.5 L (5.84%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹43.3 L
EMD Value
₹86,500
Closing Date
30 Sept 2023, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
SPECIAL REPAIRS AND REPLACEMENT OF OLD UNSERVICEABLE BER COOLING APPLIANCES AND CONNECTED ITEMS AT HQ ANC, PROVISION OF ADDITIONAL COPE BOXES FOR D AND E BERTHS AND PROVISION OF 01 IN NUMBER WATER COOLER AT CDU (PBR) UNDER GE HADDO, PORT BLAIR
2023_MES_618221_1
8766/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and Category b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹86,500
Yes
7 Dec 2023
11 Sept 2023
7 Oct 2023
11 Sept 2023
30 Sept 2023
25 Sept 2023
12 Sept 2023 - 20 Sept 2023
Amount
Supply and fix room window type air conditioner with stand and drain pipe connected upto ground level, electric driven (single phase), cooling capacity 4500 K Cal per hour (1.5 Ton) BEE 5 Star rated Make : Bluestar WFA518LL/DAIKIN/HITACHI
Supply, install, test & commissioning of Split type air conditioner, 2.0 TR capacity,BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum (3+8*) RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, complete all as specified and as directed. MAKE: BLUESTAR IC 524 DNU/HITACHI/DAIKIN NOTE: 1. Extra All connected pipes upto 8* RM shall be included in quoted rate. 2. The drain out water pipe connection should be conncted up to ground level.
Supply, install, test & commissioning of Split type air conditioner, 3.0 TR capacity,vertical tower type having cord less remote control unit, inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, three phase, 430 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum (3+8*) RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, complete all as specified and as directed. MAKE: BLUESTAR VC36GATUR3/HITACHI/DAIKIN NOTE: 1. Extra All connected pipes upto 8* RM shall be included in quoted rate. 2. The drain out water pipe connection should be conncted up to ground level.
Supply and fix Voltage Stabilizer for autimatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and capacity 4 KVA complete all as specified and as directed. Make : V-Guard / Premier
Taking down the cooling appliances such as split/window AC, water coolers, refrigarators of any capacity at various location and shifted to MES store yard
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +- 2.5 % and capacity 5 KVA complete all as specified and as directed.
S &F of Starter switch of capactity 25 Amps, working on 240 Volts AC Supply, suitable for Air Conditioner. Make : (Crabtree : Cat Part No. ACTO 252504/ or equalent in Anchor/Standard.
S & F Sub main wiring with PVC insulated cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC casing and caping (ISI marked) incl all specials and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as directed.
S & F Sub main wiring with PVC insulated cable 4 single core 6 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC casing and caping (ISI marked) incl all specials and provision of PVC insulated copper conductor single core 4.0 sq mm for earth continuity all as directed.
S &F Sheet metal enclosure with tripple pole and Earth Metalplug & Socket including 32A 3P MCB complete including taking down unserviceable enlosure all as directed by Engr-in-Charge
Material and Labour for lifting the RCC slab, approximately length (2 to 4.5m) x width (1 to 2m) and upto 300mm thick and about 3.0 to 5.0 ton in weight on IN Jetty as per site conditions by cutting/chipping the clearance groove all around, keeping aside using a crane for laying of LT/HT cables including of cable duct without disturbing the existing system including re-fixing the same slab at same location after carrying out repairs/laying of cables including making good the surfaces with PCC1:2:4 complete as directed. Note: 02 to 03 Nos of slab shall be taken out/ removed as per site condition for laying of cables/earth strip in the cable duct of jetty after for a span of 15 to 20 metres or as per site requirement.
Supply, laying and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area of size 500 sq mm 3.5 core laid in trenches / floors/ ducts or fixed on wall with suitable clamps/ saddles or drawn through pipes etc complete all as specified and directed.
Disconnecting and taking out old serviceable/under rated LT UG cables of size 300 to 500Sqmm from cable duct/trench without disturbing existing services and re-connecting the same cables complete all as specified and directed.
S & F GI earth strip of size 32x6mm laid in trench or fixed to wall/pole with necessary clamps and nuts, bolts etc. including taking out unserviceable earthing strip complete all as specified and as directed by Engineer-in-Charge.
Fabricate, supply install, test and commissioning of cope box of size 0.9 m length x 0.6 m width x 1 meter height made out of 6mm thick MS sheet, made out of 50 x 50 x 5mm angular iron frame and with provision for bottom cable entry, top opening, hinged lid and two side canopy with cable entry and 03 Nos of copper bus bar of 800 Amps capcity and 80cm ( 2 x 40cm long) , 40 x 10mm thick size fitted with bakelite sheet of 20mm thick including mounting on RCC slab with cutting and making holes for cable laying complete all as specified and as directed. Note :- Rate quoted includes cost of breaking the existing jetty slab and finishing work
Fabricate, supply install, test and commissioning of cope box of size 0.9 m length x 0.6 m width x 1 meter height made out of 6mm thick MS sheet, made out of 50 x 50 x 5mm angular iron frame and with provision for bottom cable entry, top opening, hinged lid and two side canopy with cable entry and 03 Nos of copper bus bar of 1200 Amps capcity and 80cm ( 2 x 40cm long) , 50 x 10mm thick size fitted with bakelite sheet of 20mm thick including mounting on RCC slab with cutting and making holes for cable laying complete all as specified and as directed. Note :- Rate quoted includes cost of breaking the existing jetty slab and finishing work
M & L for preparation of RCC jetty slabs of existing type, shape and thickness with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) with MS angle iron frame, reinforcement and lifting hooks as per existing slab complete all as specified and directed.
Supply and laying HDPE DWC pipe of size 120mm (OD) x 103mm (ID) along with connected accessories like couplers, bends, end caps etc, for LT/HT cable protection complete all as specified and as directed by Engineer-in-Charge. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd.
Supply & lay GI pipe 100mm medium grade in trench for road crossings/obstructions for cable protection complete all as specified & directed Make : Oswal/Jindal/TATA
Supply and fix water cooler electric driven ( single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour complete all as speified.
Supply and laying of CPVC pipe of size 20mm, SDR 11 & plain CPVC SDR 11 including all fittings such as Tees/bends/sokets/unions/ball valves on wall/ ceiling or laying in floors complete all as specified.
M&L for Point wiring two single core 2.5 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 2.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade (with proper colour coding Red/Blue/yellow for phase, black for neutral and green for earth) complete drawn through and including PVC casing and caping not less than 25mm width with all fittings, surface on wall/roof /floor including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for one 15Amps socket point controlled by one 15Amps switch Make of wire : Polycab/Gloster/Anchor/Havells/ Finolex/Anchor Make of PVC Casing & caping : Modi/Precision/Supreme/Finolex /Polycab
S&F Switch piano, flush type, single pole one way 15 amps all as directed. Make : Anchor/Cona/Legrand
S&F socket outlet 2 in 1, 3 pin 15 amp, flush type, universal all as directed. Make : Anchor/Cona/Legrand
Sree Tirumala Enterprises
ISLAND SALES ENTERPRISES
CHANDER SEKER ENTERPRISE
SKV Engineering
AMR TRADERS
M/s Karbhagam Sales Agency
Tropical Refrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .