Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹48.8 L+₹1.2 L (2.45%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹49.1 L+₹1.5 L (3.10%)Rejected-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹49.3 L+₹1.7 L (3.51%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹49.4 L+₹1.8 L (3.79%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹95,500
Closing Date
10 Jun 2021, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
GE E/M BASE HOSPITAL DELHI CANTT-110010
PROVN OF CIVIL AND ELECTRICAL WORKS INCLUDING INSTALLATION TESTING AND COMMISSIONING OF EXISTING OXEYGEN GENERATION PLANT AT BASE HOSPITAL DELHI CANTT-10
2021_MES_446407_1
GE/BH-14/2021-22
Limited
Miscellaneous Works
Item Rate
30 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category a(i) and b(i) or b(ii)
6 documents required · 6 mandatory
₹500
GE E/M BASE HOSPITAL DELHI CANTT
₹95,500
Yes
30 Jun 2021
31 May 2021
12 Jun 2021
31 May 2021
10 Jun 2021
4 Jun 2021
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
M&L RMC (ready mix concrete) 1:1.5:3, type A1, using 20mm aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
Excavation in post holes as in soft /loose soil (or similar holes) each not exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and as directed.
M & L PCC 1:2:4, type B1 Using 20mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
M&L PCC 1:4:8, type D-2, Using 20mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.
S&F 50mm thick, 40+2 Kg/Cum density, Panel consisting of 0.5mm TCT Lioydeck profiled coloured sheet on top and 0.5mm TCT plain PPGI sheet at the bottom with 50mm thick PUF sandwiched in between complete all as specified and as directed (Make Isolloyd/JSW/TATA/Jindal
S&F pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F steel tubular trusses, purlins, rafter vertical post and similar works including special shaped washer etc. complete using ERW or induction butt welded tubes including cleats, plates, hold fast and including conforming to IS 1161-1998 Gde st-240 complete all as specified and as directed.
S & F plain/chequered MS plate including cutting / welding & drilling confirming to Fe-290 (Gde -165) complete all as specified and as directed.
S&F 0.80mm thick plain galvanised, mild steel sheeting, in hips, valley gutters, drip and straight flashings (length and girth as fixed with grade of zinc coating 275 complete all as specified and as directed.
M&L preparation of new steel surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coats of synthetic painting over and including one coat of red oxide primer on new steel surfaces complete all as specified and as directed.
Use & waste of form work to flat edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC, PCC bands in walls, horizontal or sloping and similar work all exceeding 20 cm wide. (where RCC/PCC band in walls spanning and opening) complete all as specified and as directed
M&L plain cement concrete 1:3:6, type C1, using 20mm graded stone aggregate as in surface channel and drains complete all as specified and as directed.
Extra for forming fair finished drain or channel not exc 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped ends etc complete all as specified and as directed.
S&F welded steel wire fabric weight per Sqm exc 4 Kg, supplied and fixed complete to wood or steel members complete all as specified and as directed.
M&L for framed work as in doors or gates of angle or other section complete drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including bolts, if required, hook and pintle hinges; hand made sliding bolts; clamps; hold fasts either hooks and hinges or steel hanging door fitting etc conforming to Fe-410-W Gde-250 Quality -A complete all as specified and as directed
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying/ taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed.
Returning filling in,. including spreading, leveling,. watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated material from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed.
M&L Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L rendering 15mm thick cement plaster in cement mortar 1:4 on external surfaces of brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick cement plaster in cement mortar 1:6 on external surfaces of brick or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer to walls to obtain uniform surfaces including making good the surface complete all as specified & directed.
M&L preparation of new plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer of any tint on walls complete all as specifed and directed.
S&F factory made precast cement concrete U shaped drain size Width-450mm height-450mm and wall thickness 75mm jointed with cement mortar 1:4 complete all as specified an as directed.
S&F factory made precast reinforced cement concrete drain cover (RCC 1:2:4, using 20mm graded stone aggregate) 80mm thick (Square/rectangular) with and including 10mm dia TMT bars and placed over manholes at site complete all as specified and directed.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor, 11000 volts grade 95 Sqmm, 3 Core complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm complete all as specified and directed. Note:- The cost of jointing material like long sleeve for RMU connection and other connected items shall deemed to be included in quoted rate.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 Sqmm complete all as specified and directed. Note:- The cost of jointing material like long sleeve for RMU connection and other connected items shall deemed to be included in quoted rate.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 32X6 mm GI earth strip electrode welded and revetted to earth plate up to a distance of 7.5 mtr long, GI earth strip encased in and including 40mm bore GI light grade pipe, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable, heavy duty with stranded aluminum conductor, 1100 Volt grade, size 400 Sqmm, Single core complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable, heavy duty with stranded aluminum conductor, 1100 Volt grade, size 120 Sqmm, 3.5 Core complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable, heavy duty with stranded aluminum conductor, 1100 Volt grade, size 95 Sqmm, 3.5 Core complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire moured, electric power cable, heavy duty with stranded aluminum conductor, 1100 Volt grade, size 70 Sqmm, 3.5 Core complete all as specified and as directed.
S&F 320Amp Fuse Switch units, fitted with sturdy side operating handle which drives the quick make break mechanism incorporating operating springs, Liberal sized silver plated terminals, suitable for aluminum cable/bus-bar termination, provided with terminal cover shields to prevent any accidental contact with live metal parts, Positive ON-OFF indication shall be provided on the switch door, Contacts made out of electrolytic copper, electro-plated with silver, for better contact and greater resistance to corrosion, Specially designed female contacts ensure low contact resistance and better arc-control, Fuse switches designed for use with HBC Cartridge fuse links conforming to IS:13703. The enclosure shall be made out of sheet steel, rust protected, phosphatised and powder coated, duly fitted with removable top and bottom end plates, provided with knock- outs for bus bars/cables entry, front accessible door, fitted with dust-excluding gasket, interlocked to prevent opening when the switch is in ‘ON’ condition, suitable for surface mounting complete all as specified and as directed. Make Havells Cat No - IHFNTW4320 or equivalent Model of Make Siemens, Schenider.
Supplying, installation, testing and commissioning 100 KVA Servo controlled voltage stabilizer in sheet steel ventilated natural oil cooled construction (complete with first filling of transformer oil) having construction is in such a manner that all the 3 units of single phase line voltage stabilizers connected in star. The set shall cater for unbalanced load and unbalance supply provided the input voltage between any phase and neutral and output current in any phase shall be with in limits as specified below including necessary foundation with block masonry work complete all as specified and as directed: - I/P Voltage : 320V-480B, 3 Phase, unbalance I/P Frequency : 47-53 Hz O/P Voltage : 415V ± 1%, 3 Phase,50 Hz O/P should be star connected as per is 9815 O/P Adjustment : ± 5% of Rated O/P O/P Voltage accuracy : Better than + 1% Rating : 100 KVA at UPF Load : Unbalance Speed of correction : 8 V / Sec (Ph-Ph) Efficiency : Better than 96% Waveform distortion : Nil Effect of load : Nil Environment : Indoor tropical use Ambient : 0-50 Deg. C. Material for windings : Copper The Servo controlled voltage stabilizer shall also have following additional features: Full solid state control circuit, No effect ON load Power factor, Auto/manual operation facility, Tripping indication : High/Low I/P voltage tripping with overload /short circuit tripping facility, By pass arrangement with changes over switch, Audio visual alarm circuit, Indicator for I/P/O/P Volt O/P Amp frequency meter Digital/Analog.
Installation, testing and commissioning of existing Oxymat Oxygen Generation Plant, 580 LPM, including refrigeration dryer Make KAESER , along with inter connection PPR-F high pressure pipe lines max working pressure 10 Bar, with all necessary connections including providing resources for supervision and round the clock operation of oxygen plant for 30 days from the date of successful commissioning of complete plant by deploying sufficient trademans for 30 days in three shift and cost of these trademans included in quoted rate of this items.
M&L Boring holes 2 m deep in any type of soil for under-reamed piles and getting out and disposal of soil to a distance of not exc. 50 m including providing HDPE pipe of 200 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
S&F change over switch 4 pole, 415 Volt , 200 Amp capacity complete all as specified and as directed.
Supply Installation Testing & Commissioning copper pipes of 22 mm internal dia, 0.9mm wall thickness, drawn half hard temp., solid drawn, seamless, phosphorous deoxidized, non-arsenic and degreased copper pipe conforming to EN 13348: 2001 and chemical composition as per BS-6017 of 1981 table 2 complete all as specified and as directed. Note: The supplies of copper pipe shall be accompanied with manufacturers test certificate for the physical properties of copper pipes and their Chemical composition
Supply Installation Testing & Commissioning isolation ball valve with both sides end fittings for 22 mm copper pipe complete all as specified and as directed.
Supply and laying GI tubing light grade 80 mm dia with connected fitting and accessories , laying in trenches for protection of UPS power cable for ICU & HDU critical facility including inserting of cable through pipe complete all as specified and as directed.
M&L point wiring for with 1.5 Sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through and including concealed, non rigid, medium grade, PVC Conduit of minimum 25mm dia as requirement of site including cadmium plated screws as per ISI, including 3 mm thick phenolic laminated sheet top covers on and including 1.2 mm thick sunk type CI/steel terminal box, concealed in wall, including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light/fan/bell exhaust point controlled by one No, 5 Amp, one way complete all as specified and as directed.
All as per item No. 39.00 here in before but one three pin 5 Amps socket out let on independent board complete all as specified and as directed.
All as per item No. 39.00 here in before but one three pin 5 Amps socket out let on same board complete all as specified and as directed.
All as per item No. 39.00 here in before but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
S&F Switch Piano type, white polycarbonate body, 5 Amp, 230 V, single pole, one way, including connecting complete all as specified and as directed.
S&F Switch Piano type, white polycarbonate body, 15 Amp, 230 V, single pole, one way including connecting complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amp, 230 V, Multipurpose, flush type, including connecting complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amp, 230 V, flush type, including connecting complete all as specified and as directed.
S&F stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete all as specified and as directed.
S&F sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated & unsheathed cable, 1100 Volts grade, with multi stranded, copper conductor, drawn through and including 25 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS, with all fittings and one run of 4 Sqmm size PVC insulated copper conductor complete all as specified and as directed. Note:- Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S & F distribution board, double door type, SPN, 12 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and as directed.
S & F MCB SP, 240 Volts, 6 Amps to 40 Amp complete all as specified and as directed.
S & F MCB DP, 240 Volts, 40 Amps complete all as specified and as directed.
Supply, fixing and connecting Surface/Wall Mounted, 20 Watt, integrated LED, 4 feet Fitting, with polycarbonate housing & opal diffuser finish, Integral electronic driver with Output short circuit protection, Surge Voltage Protection of minimum 3 KV and Safety test as per IS15885 Part 2/ Sec 13. Total system Lumen shall be 2000 or above in Cool day Light (6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy 100 Lm/w, THD(%) < 20, LED with Average life of 50000 Burning hours. Complete with all accessories as required complete all as specified and as directed. Make - Havells Cat part No - LUMILINEBS20WLED865SPCWH or equivalent model of Make Philips/Bajaj
Supply, fixing ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
Supply, fixing PVC body, exhaust fan 380 mm dia sweep, 900 RPM, 240 Volt, heavy duty, with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed.
Supply, fixing ceiling fan 1400mm sweep, (white), BEE 3/5 star rating, including suitable size of down rod and flexible wire 2 core of size 23 X .0076' and clamps and nut and bolts complete all as specified and as directed.
Supply, fixing and connecting LED security light fitting, 45 Watt, cast aluminum housing, toughened glass, silicon gasket, high power LED with lens for uniform distribution, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including 1.5 Metre long, 40 mm bore, medium grade, GI pipe bracket with clamps and bolts complete all as specified and as directed. Make - Havells Cat Part No- ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent model of Make Philips/Bajaj.
M&L Earthing complete with galvanised Iron earth plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25mtrdeep below GL) with top edge of the plate not less than 1.5 metre below normal ground level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Building at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate up to main DB of bldg, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including excavation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type BI duly reinforced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Rajindera Enterprises
L G BUILDERS
M/s Dhapola Elevator and Engineering
M/S Sunil Steel Works
SANJEEV ENTERPRISES
Shivam Firetech Engineers
Vishal Traders
M/S Rohit Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .