| 1 | Admitted-Fee/PreQual/Technical 135 139 BILAKHIA HOUSE MUKTANANAD MARG CHALA VALSAD GUJARAT 396191 | VALSAD | GUJARAT | 396191 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹90 L
EMD Value
₹1.8 L
Closing Date
9 Mar 2026, 10:00 amClosed
PMO DH DAUSA
DISTRICT HOSPITAL DAUSA
PURCHASE OF ARTHOPLASTY IMPLANTS FOR DISTRICT HOSPITAL DAUSA
2026_MEDIC_543139_1
DH DAUSA EBID 10/2025-26 (2065) FOR Arthoplasty Implants, C-Arm Machine Machine
Open Tender
Medical Equipments/Waste
Item Wise
DH DAUSA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
MEMBER SECRETARY RMRS DISTRICT HOSPITAL DAUSA
₹1.8 L
Yes
DH DAUSA
3 May 2026
1 Mar 2026
9 Mar 2026
1 Mar 2026
9 Mar 2026
5 Mar 2026
4 Mar 2026
Total Hip replacement (THR) – All Sizes Un cemented: -(Metal on Poly) All should be of Same Make Implant Should be USFDA / INDIANFDA approved only
The femoral Stem should have morphometric wedge geometry and HA coating Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options / Two Neck Angle minimum and made up of titanium material.
The acetabular shell made of Titanium Hemispherical should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with required cancellous bone screws. Can accomadate 22, 28, 32, 36, head
Insert should be Highly Cross linked polyethylene. The Polyethylene should have 0-20 degree or more posterior superior lip. The Polyethylene is compatible to accommodate 22mm/28mm, 32mm, and 36mm heads.
Femoral heads should be COCR with all sizes 22mm/ 28mm/32mm/36mm with minimum 4 variable necklength.
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
Total Hip replacement (THR) – All Sizes Un cemented: -(Ceramic on Poly) All should be of Same Make Implant Should be USFDA / INDIANFDA approved only
The femoral Stem should have morphometric wedge geometry and HA coating . Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options / two neck angle minimum and made up of Ti6Al4V material.
The acetabular shell made of Titanium Hemispherical should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 38 to 64 mm with required cancellous bone screws. Can accomadate 22, 28, 32, 36, head
Insert should be Highly Cross linked polyethylene. The Polyethylene has 0-20 degree or more posterior superior lip. The Polyethylene is compatible to accommodate 22mm/28mm, 32mm, and 36mm heads.
Femoral heads should be Ceramic with all sizes 22mm/28mm/32mm/36mm with minimum 4 variable necklength. .
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
Total Hip replacement (THR) – All Sizes Cemented: - With metal on poly. Note: - All should be of Same Make except cement Implant Should be USFDA / INDIANFDA approved only
Cemented femoral stem ss should Highly polished, Double tapered with collarless design.
The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cement spacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 22mm/28 /32 / 36 mm with OD 42 – 60 mm with two packets of bone cement.
Femoral heads should be COCR Metal Head with all sizes 22mm/28mm/32mm/36mm with minimum 4 variable necklength.
Total Knee replacement Cemented Oxidized Zircoinum Hi-flex – All Sizes Note: - All should be of Same Make except cement Should provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only
femoral component should be availabe in have both PS/CR Option should have standard & narrow option ,Should have ability to accept Augments in Primary femur, should be made up of Oxidized Zirconium meterial,Primary femur should accept constrained insert also
Tibial component Should be Anatomical & made up of titanium alloy,Same tibia should accept all type of inserts PS/CR/ConstraintShould have highly polished surface
Polyethelene Should have PS/CR/Constraint Insert option both in PS/CR
Patella Should be Round Made up of UHMPWE Polyethelene Size should have 29-35mm
Bone Cement
Complex/ Revision hip replacement with all type & size of wedges & cages etc.THR. Note: - All should be of Same Make except cement Implant Should be USFDA / INDIANFDA approved only
The acetabular shell should porous coating. The acetabular shell should feature two independent locking mechanisms for polyethylene liners and ceramic liners ( optional). The acetabular shell should have minimum 3 hole options.. The Acetabular Shell sizes should come in sizes from 44 to 62 mm with required cancellous bone screws. The system should compose of a Liner and Poly Insert. The system should incorporate the following dual points of articulation- • 22.2mm or 28mm femoral Metal head. • Large polyethylene insert that mimics a femoral head
Dual Mobility Liner- • Dual Mobility Liner should be made of CoCr. • The system should have inner change locking mechanism and positive rotation tabs • The Liner should come with Removal Tool Slot. • The Liner should be available in all sizes- 36 to58
Poly Insert- The insert should be made up of Highly Cross linked polyethylene which should be wear resistant
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck lengthoptions, two offset options minimum and made up of Ti6Al4V material.
Femoral heads should be COCR Metal with all sizes 22.2/ 28mm
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
Total Knee replacement Cemented Gold TKR– All Sizes Note: - All should be of Same Make except cement Should provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only
Gold (TiNbN coated) Femur with 7 radii design, with thin Anterior flange, Femur should have 6 degree deep trochlear groove with asymmetrical cam & Spine mechanism for rotation up to 15 degree.
Gold (TiNbN coated) Tibial Base Plate should have a 5 point locking mechanism, All Sizes
Ultra High Molecular weight Polyethylene liner with Vitamin-E.
Universal Patella
40 gms Bone Cement
Complex/ Revision hip replacement with all type & size of wedges & cages etc.THR. Note: - All should be of Same Make except cement Implant Should be USFDA / INDIANFDA approved only
Revision uncemented stem should be long and length should be between 180 - 380 mm, Modular or distal fixing stem / Calcar replacing
Revision uncemented acetabular shell have multi hole with min. 8 holes and HA/ highly porous Coated.
Revision uncemented acetabular shell should provide dual mobility cup which composed of CoCr liner and highly crossed linked polyethylene which support 22- and 28-mm femoral metal head.(optional)
Acetabulum augments
Acetabulum mesh.
Acetabulum cages various sizes
Uncemented acetabular shell especially designed for protrusion which is peripherally locking.
Cancellous bone screws of 6.5 mm in length and 20 to 60 mm in diameter.
Revision cemented stem should long and the length would more than 200 mm, with bone cements.
The Cemented cup should have Ultra-High Molecular Weight Polyethylene with PMMA cementspacer easily identifiable the cup position on an X-ray. Cup Should be available in the I.D 28 /32 / 36mm with OD 46 – 60 mm.
The femoral Stem should have morphometric wedge geometry and HA coating/ porous coating. Coating of minimum 50-micron thick, Proximal body should be circumferentially plasma sprayed ( optional ) , Incremental Neck length options, two offset options minimum and made up of Ti6Al4V material.
Femoral heads should be COCR Metal Head with all sizes 22mm/ 28mm/ 32mm/ 36mm.
Insert should be Highly Cross linked polyethylene. The Polyethylene has 10-degree or more posterior superior lip. The Polyethylene is compatible to accommodate 28mm, 32mm, and 36mm heads.
Femoral heads should be Ceramic with all sizes 28mm/32mm/36mm. Note- Should provide quotation for individual components.
Total Knee replacement Cemented (TKR) Hi-flex – All Sizes Note: - All should be of Same Make except cement Should provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only
Primary Cemented TKR- Femoral components COCR various sizes, Narrow & standard option with ability to accept both distal and Posterior augment, PS & CR TKR can be done with same instrument. Implants should have good survivourship rate
Tibial Baseplate various sizes, titanium, anatomical tibia base plate with ability to accept extension stem/ rod, Tiba can accommodate any size ( + 2) Femoral Component
highly crossed linked polyethylene various sizes, should have option for High fkex, constrained poly inn same poly both PS & CR
patellar component various sizes
Bone Cement Note: - All should be of Same Make except cement
Unicondylar Knee replacement Fixed Bearing Unicondylar Knee Note: - All should be of Same Make except cement
Uni-condylar Knee Femoral Component Should be made up of Oxidized Zirconium Material,Should have Size 2-7 LM/RL, Should have same Lug preparation from Size 3-7,
Uni-condylar Knee tibial Component Should be made up of titanium Alloy
Inserrt Should be Madeup of Highly crosslinked P{olyethelyne material Size should be 8,9,10,11mm
Bone Cement
Mobile Bearing Unicondylar Knee Note: - All should be of Same Make except cement
Uni-condylar Knee Femoral Component Should be made up of Cocr Material,Should have Size 2-7 LM/RL, Should have same Lug preparation from Size 3-7,
Uni-condylar Knee tibial Component Should be made up of Cocr
Inserrt Should be Madeup of Highly crosslinked P{olyethelyne material Size should be 8,9,10,11mm
Bone Cement antibiotic/ normal
Revision Knee replacement all size and stems and wedges Semi constraint TKR should have following components Note: - All should be of Same Make except cement Implant Should be USFDA approved only
Femoral component compatible with stem extension.
Tibial Baseplate compatible to stem extension.
Semi constrained polyethylene.
Distal Augments.
Posterior Augments
Offset
Tibial wedges various options
Patellar component
Fluted Stem
Bone Cement
Revision knee replacement all size and stems and wedges Hinge TKR should have following components Note: - All should be of Same Make except cement Implant Should be USFDA / INDIANFDA approved only
Femoral component compatible with stem extension.
Tibial Baseplate compatible to stem extension.
constrained polyethylene.
Distal Augments.
Posterior Augments
Offset
Tibial wedges various options
Patellar component
Fluted Stem
Bone Cement
Sleeve Tibia/Femur sleeve
Tibia femur cone
HEMI Shoulder replacement implants – all sizes including fracture stem All should be of Same Make Note - Note Should provide quotation for individual components
Fracture Stem Reverse Morse Taper provides the ability to move between a hemi, total, or reverse shoulder arthroplasty without removing a well-fixed Comprehensive Fracture Stem Anatomic 45 degree neck angle provides ample room under the collar for tuberosity reconstruction Contoured suture holes provide for significant reduction in suture wear. Six diameters available: 4, 6, 8, 10, 12, and 14mm Designed for cemented or uncemented applications
Humeral Head - Different variable sizes available in 38mm, 42mm, and 46mm
Taper Adaptor
Total Knee replacement Cemented (TKR) Hi-flex – All Sizes Note: - All should be of Same Make except cement Should provide option both PS and CR knee in same implant Implant Should be USFDA / INDIANFDA approved only
Primary Cemented TKR- Femoral components COCR various sizes, Narrow & standard option with ability to accept both distal and Posterior augment, PS & CR TKR can be done with same instrument. Implants should have good survivourship rate
Tibial Baseplate various sizes, titanium, anatomical tibia base plate with ability to accept extension stem/ rod, Tiba can accommodate any size ( + 2) Femoral Component
highly crossed linked polyethylene various sizes, should have option for High fkex, constrained poly inn same poly both PS & CR
patellar component various sizes
Bone Cement Note: - All should be of Same Make except cement
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.23 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BID_Aarthoplasty.pdf
Tender Documents • 14.21 MB
BOQ_968270.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .