ELECTRICAL WORKS AT BARHI LPG PLANT
20000671-HD-10157
20000671-HD-10157
Open Tender
Two Bid
Balod, Chhattisgarh
₹0
Exempted
22 Dec 2020
1 Dec 2020
22 Dec 2020
22 Dec 2020
1 Dec 2020 - 15 Dec 2020
8 Dec 2020
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 5 | S,ITC of 40W FLP LGHT | S,ITC of 40W FLP LGHT — FLAMEPROOF LED WITH ENCLOSURE; POWER CONSUMPTION:40 W; MINIMUM LUMEN OUTPUT:N/A; INGRESS PROTECTION,ENCLOSURE:N/A; INGRESS PROTECTION:N/A; TYPE OF PROTECTION:N/A; ADDITIONAL INFORMATION:LINEAR FITTING; WELL GLASS LIGHT OR EQUIVALENT FITTINGS AS PER SPECS OF FLP LED LIGHTS OF APPROVED MAKE MEETING TECHNICAL AND FUNCTIONAL REQUIREMENTS FOR LED LIGHTS CONFORMING TO CMRI. DETAILED SPECIFICATION AS PER ATTACHED TENDER DOCUMENT. 6 S,ITC of WELD SCOKET 42662- Each 11 Yes FLAME PROOF TYPE 63 AMP. WELDING SOCKET-IP65 IIA/IIB-T3 CATEGORY. 7 S, ITC OF FLP 4W JB 42662- Each 15 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 20 A FLP SOCKET: FLAMEPROOF TYPE (SUITABLE FOR EX-D, ZONE-1, GAS GROUP IIA, TEMPERATURE. CLASS T2), 415 V, 20 A, 5 (3P+N+E) PIN THREE PHASE SOCKET OUTLET SUITABLE FOR IP 55 PROTECTION, WALL/STRUCTURE MOUNT WITH 20A 4 POLE MCB+ELCB AND PLUG TOP WITH TERMINAL SUITABLE FOR CABLE TERMINATION (SIZE TO BE CONFIRMED DURING DETAILING) LM6 DIE CAST BODY WITH LOOP IN LOOP OUT FACILITY. EACH SOCKET SHALL BE PROVIDED WITH FLAMEPROOF 4 WAY JUNCTION BOX WITH SUITABLE ENTRIES, PLUGS, GLANDS (SIZE TO BE CONFIRMED DURING DETAILING) ETC. AND ALL OTHER ACCESSORIES AS REQUIRED AT SITE. 8 S, ITC OF FLP 4W JB2 42662- Each 20 Yes JUNCTION BOX; CONFIGURATION:4-WAY; CLASSIFICATION,HAZARD AREAS:ZONE-1, IIA/IIB, T3; MATERIAL:LM6; DIMENSION:N/A; NO OF CABLE ENTRIES:N/A; ADDITIONAL INFORMATION:FLAMEPROOF; FLAMEPROOF, 8 NUMBER DIN MOUNTED TERMINAL, LIGHTING JUNCTION BOX ALONG WITH 4 NUMBER, FLAMEPROOF CABLE GLAND, PVC SHROUD, LUGS ETC. COMPLETE 9 S, ITC OF FLP 4W JB3 42662- Each 3 Yes JUNCTION BOX; CONFIGURATION:4-WAY; CLASSIFICATION,HAZARD AREAS:ZONE-1, IIA/IIB, T3; MATERIAL:LM6; DIMENSION:N/A; NO OF CABLE ENTRIES:N/A; ADDITIONAL INFORMATION:FLAMEPROOF; FLAMEPROOF, 8 NUMBER DIN MOUNTED TERMINAL, LIGHTING JUNCTION BOX ALONG WITH 4 NUMBER, FLAMEPROOF CABLE GLAND, PVC SHROUD, LUGS ETC. COMPLETE 10 S, ITC OF FLP 4W JB4 42662- Each 2 Yes JUNCTION BOX; CONFIGURATION:4-WAY; CLASSIFICATION,HAZARD AREAS:ZONE-1, IIA/IIB, T3; MATERIAL:LM6; DIMENSION:N/A; NO OF CABLE ENTRIES:N/A; ADDITIONAL INFORMATION:FLAMEPROOF; FLAMEPROOF, 8 NUMBER DIN MOUNTED TERMINAL, LIGHTING JUNCTION BOX ALONG WITH 4 NUMBER, FLAMEPROOF CABLE GLAND, PVC SHROUD, LUGS ETC. COMPLETE 11 Sup, ITC of SPN MCB 42662- Each 2 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF SPN MINIATURE CIRCUIT BREAKER: 6 A, SPN MINIATURE CIRCUIT BREAKER SUITABLE FOR EX-D, ZONE-1, GAS GROUP IIA, TEMP. CLASS T2 HAZARDOUS AREA WITH TWO ENTRIES SUITABLE FOR 3C X 2.5 SQ MM 2XWY (1100 V) ARMOURED CABLES.(FOR LIGHTING APPLICATION). 12 Sup, ITC of FLP Socket 42662- Each 4 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF FLAMEPROOF SOCKET: 24V AND 240 V, 15 A SINGLE PHASE FLAMEPROOF TYPE (SUITABLE FOR EX-D, ZONE-1, GAS GROUP IIA, TEMP. CLASS T2), PLUG AND SOCKET SHALL BE PROVIDED WITH 3 PINS (2P+E) WITH BUILT IN 100VA, 240 V/24 V TRANSFORMER. 13 S,ITC OF FLP HAND LAMP 42662- Each 4 Yes SUPPLY AND INSTALLATION OF LED DOWNLIGHT-15 WATT, APPROVED MAKE. 14 Sup,ITC of 9WDB 42662- Each 5 Yes SUPPLY INSTALLATION, TESTING AND COMMISSIONING OF DISTRIBUTION BOARD: 415 V, TPN, SINGLE FRONT, WALL MOUNT, FLAMEPROOF TYPE (SUITABLE FOR EX-D, ZONE-1, GAS GROUP IIA, TEMP. CLASS T2), 9 WAYS (EACH OF 240V, 1PH, 50HZ) NORMAL LIGHTING DB WITH 1 NO. 32A 4P MCB AS INCOMER AND 9 NOS 10A DP MCB + ELCB AS OUTGOING FEEDERS. CABLE SIZES TO BE CONFIRMED DURING DETAIL ENGINEERING. 15 Sup,ITC of 12WDB 42662- Each 1 Yes SUPPLY, INSTALLATION ,TESTING AND COMMISSIONG OF DB AS PER TECHNCIAL SPECIFICATION AND DESCRIPTION PROVIDED IN SOQ. 16 Sup,ITC of 6WDB 42662- Each 3 Yes SUPPLY, INSTALLATION ,TESTING AND COMMISSIONG OF DB AS PER TECHNCIAL SPECIFICATION AND DESCRIPTION PROVIDED IN SOQ. 17 S,ITC of WP 60W LGHT 42662- Each 10 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LED LIGHTS: INDUSTRIAL TYPE 240 V, 60 W LED (APPROVED MAKE CATALOGUE NO: A200044 60 W LED TENTO NXT B 60L WH MB SD OR EQUIVALENT), SUSPENDED MOUNTING, NON INTEGRAL HIGH BAY TYPE LIGHTING FIXTURE WITH JUNCTION BOX AND CONTROL GEAR BOX COMPLETE WITH LAMPS, HOUSING, REFLECTORS, INDUSTRIAL TYPE GLANDS, METALLIC PLUGS ETC. AND ALL OTHER ACCESSORIES AS REQUIRED AT SITE. 18 S,ITC of WP 40W LGHT 42662- Each 12 Yes SUPPLY, INSTALLATION ,TESTING AND COMMISSIONG OF LED LIGHTS AS PER TECHNCIAL SPECIFICATION AND DESCRIPTION PROVIDED IN SOQ. 19 S,ITC of WP 25W LGHT 42662- Each 6 Yes SUPPLY, INSTALLATION ,TESTING AND COMMISSIONG OF LED LIGHTS AS PER TECHNCIAL SPECIFICATION AND DESCRIPTION PROVIDED IN SOQ. 20 S,ITC OF SWITCH 42662- Each 6 995461 Yes SOCKET OUTLETS INSTALLATION OF FOLLOWING TYPE SWITCH- SOCKET OUTLETS AS PER ATTACHED SPECIFICATION OF EQUIPMENT SUPPLIED BY CONTRACTOR. INDUSTRIAL TYPE (NON FLAME PROOF) IP-55 5/15A, 240V, 50HZ, SINGLE PHASE DECORATIVE TYPE SWITCH SOCKET OUTLET 21 GI Pole for Handrail 42662- Each 6 Yes POLE; MATERIAL:GALVANIZED IRON; HEIGHT:3 MT; DIAMETER:80 MM; FOR HANDRAIL MOUNTING OF FIXTURE 22 Sup, ITC of light Pole 42662- Each 6 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LIGHT POLE: NB 50 PIPE WITH CLAMP, NUTS AND BOLTS REQUIRED FOR STREET LIGHT AS PER INSTALLATION DWG 11387-00-ELE-DWG-0001. 23 Sup, ITC of WP4W JB 42662- Each 6 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF JUNCTION BOX: 4 WAY JUNCTION BOX SUITABLE FOR SAFE AREA FOR TERMINATION OF 3C X 2.5 SQ MM 2XWY (1100 V) ARMOURED CABLES. 24 Sup,ITC of SPN MCB 42662- Each 1 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF SPN MINIATURE CIRCUIT BREAKER: 6A, SPN MCB WITH TWO ENTRIES SUITABLE FOR 3C X 2.5 SQ MM 2XWY (1100V) ARMOURED CABLES.(FOR LIGHTING APPLICATION). 25 Sup, ITC of 6W LDB 42662- Each 7 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DISTRIBUTION BOARD: 415 V, TPN, SINGLE FRONT, WALL MOUNT, INDUSTRIAL TYPE, 6 WAYS (EACH OF 240 V, 1PH, 50HZ) NORMAL LIGHTING DB WITH 1 NO. 32 A 4 P MCB AS INCOMER AND 6 NOS 10 A DP MCB + ELCB AS OUTGOING FEEDERS. CABLE SIZES TO BE CONFIRMED DURING DETAIL ENGINEERING. 26 Sup, ITC of LCS1 42662- Each 1 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF LOCAL CONTROL STATION (LCS): SUPPLY AND INSTALLATION OF LOCAL CONTROL STATION WITH ALL ACCESSORIES AS PER APPROVED DRAWINGS, LAYOUTS, SPECIFICATIONS, DATASHEETS, VENDOR LIST ETC. INCLUDING THE TRANSPORTATION UPTO THE SITE/YARD, UNLOADING, STORAGE AT SITE OF WEATHERPROOF, IP 55, INDUSTRIAL TYPE, MUSHROOM HEAD, PADLOCKABLE IN OFF POSITION, STAY PUT TYPE STOP P.B. WITH OFF INDICATION LAMP FOR TRANSFORMERS AND ESD IN CONTROL ROOM WITH 2 NO + 2 NC CONTACTS, GLANDS ETC. CABLE SIZES TO BE CONFIRMED DURING DETAIL ENGINEERING. 27 Sup, ITC of LCS2 42662- Each 1 Yes SUPPLY, INSTALLATION AND COMMISSIONING OF LOCAL CONTROL STATION AS PER TECHNCIAL SPECIFICATIONS AND DESCRIPTION PROVIDED IN BOQ 28 Sup, ITC of LCS3 42662- Each 1 Yes SUPPLY, INSTALLATION AND COMMISSIONING OF LOCAL CONTROL STATION AS PER TECHNCIAL SPECIFICATIONS AND DESCRIPTION PROVIDED IN BOQ 29 S,ITC OF 3CX2.5 CBL 42662- Running Meter 1000 995423 Yes SUPPLY, LAYING, TESTING AND COMMISSIONING OF 1.1KV GRADE XLPE INSULATED FRLS PVC OUTER SHEATH, ALUMINIUM/COPPER CONDUCTOR ARMOURED POWER/CONTROL CABLE (A2XWY/2XFY) CONFORMING TO GIVEN SPECIFICATION. THE CABLES SHALL BE LAID ON PERFORATED/LADDER TYPE TRAYS OR IN TRENCH/IN PIPES/CLAMPED TO WALL/CEILING AS REQUIRED. APPROVED MAKE OF 3C X 2.5 SQ.MM YWY (MULTISTRAND CU CONDUCTOR FLEXIBLE UNARMOURED CABLE, FROM LIGHTING JUNCTION BOXES TO LIGHTING FIXTURES). REFER BOQ AND TECHNICAL SPECIFICATIONS FOR DETAIL DESCRIPTION. 30 S,ITC OF 3CX4 CBL 42662- Meters 100 Yes SUPPLY, LAYING, TESTING AND COMMISSIONING OF 3C X 4 SQMM, COPPER - XLPE FRLS POWER CABLES AS PER ATTACHED JOB SCHEDULE, TENDER SPECIFICATION, AND DIRECTIONS OF ENGINEER-IN-CHARGE. 31 S,ITC OF 3CX6 CBL 42662- Meters 100 Yes SUPPLY, LAYING, TESTING AND COMMISSIONING OF 3C X 6 SQMM, COPPER - XLPE FRLS POWER CABLES AS PER ATTACHED JOB SCHEDULE, TENDER SPECIFICATION, AND DIRECTIONS OF ENGINEER-IN-CHARGE. 32 S,ITC OF 1CX300SM CBL 42662- Meters 1300 Yes CABLE LAYING: SUPPLY AND LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ. 33 S,ITC OF 3CX300SM HT CBL 42662- Meters 300 Yes CABLE LAYING: SUPPLY AND LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ. 34 S,ITC OF 9CX2.5SM CBL 42662- Meters 2900 Yes CABLE LAYING: SUPPLY AND LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ. 35 SITC OF OUT HV TER KIT 42662- Each 2 995461 Yes OUTDOOR TERMINATION KIT (EARTHED SYSTEM): SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 3 C X 300 SQ.MM 11 KV A2XCEFY (XLPE) ARMOURED HT CABLE TERMINATION KITS, TERMINATION SHALL BE INDOOR/OUTDOOR TYPE FOR HT CABLES. RATE SHALL INCLUDE ALL ACCESSORIES, GI CLAMPS, TAGS AND WHEREVER REQUIRED, INCLUDING CABLE LUGS. 36 SITC OF INDR HV TER KIT 42662- Each 3 995461 Yes INDOOR TERMINATION KIT (EARTHED SYSTEM): SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 3 C X 300 SQ.MM 11 KV A2XCEFY (XLPE) ARMOURED HT CABLE TERMINATION KITS, TERMINATION SHALL BE INDOOR/OUTDOOR TYPE FOR HT CABLES. RATE SHALL INCLUDE ALL ACCESSORIES, GI CLAMPS, TAGS AND WHEREVER REQUIRED, INCLUDING CABLE LUGS. 37 SITC OF I/O HV TER KIT 42662- Each 3 Yes END TERMINATION KIT FOR 3C X 240 -300 SQ MM, 11 KV CBLE LONG DESCRIPTION SUPPLY AND INSTALL INDOOR END TERMINATION KIT OF RAYCHEM MAKE AS PER SPECIFICATION AND DIRECTION OF ENGINEER-IN-CHARGE. 38 1Cx300 CBLE GLAND,SITC 42662- Each 92 995461 Yes NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 39 2Cx4CBLE GLAND,SITC 42662- Each 6 995461 Yes NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 40 2Cx6SQ MM CBLE GLAND,SITC 42662- Each 2 995461 Yes NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 41 2Cx10SQ MM CBLE 42662- Each 1 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 42 2Cx16SQ MM CBLE 42662- Each 4 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 43 3Cx2.5SQ MM CBLE 42662- Each 100 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3CX2.5 SQ.MM (CU) 44 3Cx4SQ MM CBLE GLAND,SITC 42662- Each 114 Yes WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3CX4 SQ.MM (CU) 45 3Cx6SQ MM CBLE GLAND,SITC 42662- Each 29 995461 Yes NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 46 4Cx10SQ MM CBLE 42662- Each 39 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 47 3.5Cx16 SQ MM CBLE 42662- Each 6 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 48 4Cx2.5 SQ MM CBLE 42662- Each 5 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:4CX2.5 SQ.MM (CU) 49 4Cx4 SQ MM CBLE 42662- Each 29 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:4CX4 SQ.MM (CU) 50 4Cx6 SQ MM CBLE 42662- Each 22 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:4CX6 SQ.MM (CU) 51 4Cx10 SQ MM CBLE 42662- Each 2 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:4CX10 SQ.MM (CU) 52 4Cx16 Sq.mm, 2XFY,1.1kV, 42662- Each 1 995461 Yes FRLS NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 53 3.5Cx25 SQ MM CBLE 42662- Each 46 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3.5CX25 SQ.MM (AL) 54 3.5Cx35 SQ MM CBLE 42662- Each 20 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3.5CX35 SQ.MM (AL) 55 3.5Cx50 SQ MM CBLE 42662- Each 16 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3.5CX50 SQ.MM (AL) 56 3.5Cx70 SQ MM CBLE 42662- Each 28 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 57 3.5Cx95 SQ MM CBLE 42662- Each 2 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 58 3.5Cx120 SQ MM CBLE 42662- Each 2 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3.5CX120 SQ.MM (AL) 59 3.5Cx150 SQ MM CBLE 42662- Each 23 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 60 3.5Cx185 SQ MM CBLE 42662- Each 10 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:3.5CX185 SQ.MM (AL) 61 3.5Cx240 SQ MM CBLE 42662- Each 1 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 62 5Cx2.5 SQ MM CBLE 42662- Each 144 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:5CX2.5 SQ.MM (CU) 63 7Cx2.5 SQ MM CBLE 42662- Each 20 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:7CX2.5 SQ.MM (CU) 64 9Cx2.5 SQ MM CBLE 42662- Each 11 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 65 12Cx2.5 SQ MM CBLE 42662- Each 4 Yes GLAND,SITC WEATHER PROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD OF THE FOLLOWING SIZE OF XLPE,ARMOURED FRLS CABLES:12CX2.5 SQ.MM (CU) 66 3.5Cx240 VFD CBLE 42662- Each 1 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 67 3.5Cx185 VFD CBLE 42662- Each 2 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 68 3.5Cx120 VFD CBLE 42662- Each 2 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 69 3.5Cx95 VFD CBLE 42662- Each 4 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 70 3.5Cx70 VFD CBLE 42662- Each 1 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 71 3.5Cx50 VFD CBLE 42662- Each 1 995461 Yes GLAND,SITC NFLP CABLE GLANDS AND TERMINATION:- SUPPLY AND INSTALLATION OF DOUBLE COMPRESSION NON FLAME PROOF NICKEL PLATED CABLE GLANDS OF APPROVED MAKE AND TERMINATION OF CABLES PANEL/JB GLAND PLATE AND FIXING THE SAME. 72 1Cx300 CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF GLAND FOR CABLE: SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF GLAND SUITABLE FOR 1 C X 300 SQ.MM, A2XFY, 1.1 KV, FRLS CABLE. 73 2Cx4CBLE FLP GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 74 2Cx6FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 75 2Cx10FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 76 2Cx16FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 77 3Cx2.5FLP CBLE GLAND,SITC 42662- Each 11 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:3CX2.5 SQ.MM (CU) 78 3Cx4FLP CBLE GLAND,SITC 42662- Each 90 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:3CX4 SQ.MM (CU) 79 3Cx6FLP CBLE GLAND,SITC 42662- Each 27 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 80 4Cx10FLP CBLE GLAND,SITC 42662- Each 9 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 81 3.5Cx16 FLP CBLE 42662- Each 6 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 82 3.5Cx25FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 83 3.5Cx35FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 84 3.5Cx50FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 85 3.5Cx70FLP CBLE GLAND,SITC 42662- Each 7 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 86 3.5Cx95FLP CBLE GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 87 3.5Cx120FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 88 3.5Cx150FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 89 4Cx2.5 FLP CBLE GLAND,SITC 42662- Each 1 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:4CX2.5 SQ.MM (CU) 90 4Cx4 FLP CBLE GLAND,SITC 42662- Each 11 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:4CX4 SQ.MM (CU) 91 4Cx6 FLP CBLE GLAND,SITC 42662- Each 10 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:4CX6 SQ.MM (CU) 92 4Cx10 FLP CBLE GLAND,SITC 42662- Each 1 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:4CX10 SQ.MM (CU) 93 4Cx16 Sq.mm, 2XFY,1.1kV, 42662- Each 1 Yes FRLS SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 94 3.5Cx25 FLP CBLE 42662- Each 5 Yes GLAND,SITC FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:3.5CX25 SQ.MM (AL) 95 3.5Cx35 FLP CBLE 42662- Each 4 Yes GLAND,SITC FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:3.5CX35 SQ.MM (AL) 96 3.5Cx50 FLP CBLE 42662- Each 2 Yes GLAND,SITC FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:3.5CX50 SQ.MM (AL) 97 3.5Cx70 FLP CBLE 42662- Each 7 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 98 3.5Cx95 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 99 3.5Cx120 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 100 3.5Cx150 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 101 3.5Cx185 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 102 3.5Cx240 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 103 5Cx2.5 FLP CBLE GLAND,SITC 42662- Each 112 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:5CX2.5 SQ.MM (CU) 104 7Cx2.5 FLP CBLE GLAND,SITC 42662- Each 20 Yes FLAMEPROOF DOUBLE COMPRESSION NI PLATED BRASS CABLE GLAND WITH PVC SHROUD SUITABLE FOR FOLLOWING XLPE , FRLS,ARMOURED CABLE SIZE & AS PER RELEVANT IS/IEC FOR HAZARDOUS AREA ZONE-1,IIA/IIB,T3:7CX2.5 SQ.MM (CU) 105 9Cx2.5 FLP CBLE GLAND,SITC 42662- Each 5 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 106 12Cx2.5 FLP CBLE 42662- Each 1 Yes GLAND,SITC SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 107 3.5Cx240 VFD FLP GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 108 3.5Cx185 VFD FLP GLAND,SITC 42662- Each 2 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 109 3.5Cx120 VFD FLP GLAND,SITC 42662- Each 2 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 110 3.5Cx95 VFD FLP GLAND,SITC 42662- Each 4 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 111 3.5Cx70 VFD FLP GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 112 3.5Cx50 VFD FLP GLAND,SITC 42662- Each 1 Yes SUPPLY INSTALLATION & TESTING OF FLP CABLE GLAND AS PER TECHNCIAL SOECIFICATIONA AND DESCRIPTION PROVIDED IN SOQ 113 2.5 Sq.mm Cable Lug , SITC 42662- Each 1730 Yes SUP. OF LUGS FOR 2.5 SQMM, CU- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 114 4 Sq.mm Cable Lug , SITC 42662- Each 790 Yes SUP. OF LUGS FOR 4 SQMM, CU- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 115 6 Sq.mm Cable Lug , SITC 42662- Each 310 Yes SUP. OF LUGS FOR 6 SQMM, CU- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 116 10 Sq.mm Cable Lug , SITC 42662- Each 155 Yes SUP. OF LUGS FOR 10 SQMM, CU- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 117 16 Sq.mm Cable Lug , SITC 42662- Each 50 Yes SUP. OF LUGS FOR 16 SQMM, CU- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 118 25 Sq.mm Cable Lug , SITC 42662- Each 160 Yes SUP. OF LUGS FOR 25 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 119 35 Sq.mm Cable Lug , SITC 42662- Each 75 Yes SUP. OF LUGS FOR 35 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 120 50 Sq.mm Cable Lug , SITC 42662- Each 60 Yes SUP. OF LUGS FOR 50 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 121 70 Sq.mm Cable Lug , SITC 42662- Each 110 Yes SUP. OF LUGS FOR 70 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 122 95 Sq.mm Cable Lug , SITC 42662- Each 30 Yes SUP. OF LUGS FOR 95 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 123 120 Sq.mm Cable Lug , SITC 42662- Each 1 Yes SUP. OF LUGS FOR 120 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 124 150 Sq.mm Cable Lug , SITC 42662- Each 1 Yes SUP. OF LUGS FOR 150 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 125 185 Sq.mm Cable Lug , SITC 42662- Each 45 Yes SUP. OF LUGS FOR 185 SQMM,AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 126 240 Sq.mm Cable Lug , SITC 42662- Each 1 Yes SUP. OF LUGS FOR 240 SQMM, AL- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 127 300 Sq.mm Cable Lug , SITC 42662- Each 280 Yes SUPPLY OF LUGS OF FOLLWING SIZES ALL COMPLETE AS PER TECHNICAL SPECIFICATIONS, APPROVED SAMPLES ETC. AND DIRECTIONS OF ENGINEER IN CHARGE.AL. LUGS 300 SQMM 128 SITC OF EARTH BUS1 42662- Each 50 Yes SUPPLY AND LAYING OF GALVANIZED IRON EARTH BUS BAR COMPLETE WITH ALL ACCESSORIES. 129 SITC OF EARTH BUS2 42662- Each 30 Yes SUPPLY AND LAYING OF GALVANIZED IRON EARTH BUS BAR COMPLETE WITH ALL ACCESSORIES. 130 SITC OF EARTH BUS3 42662- Each 10 Yes SUPPLY AND LAYING OF GALVANIZED IRON EARTH BUS BAR COMPLETE WITH ALL ACCESSORIES. 131 1C x 4 CBL, SITC 42662- Meters 20 995423 Yes SUPPLY AND LAYING OF 4 SQ.MM PVC INSULATED COPPER CONDUCTOR OF APPROVED MAKE (COLOUR CODING WILL BE DECIDED BY ENGINEER). 132 1C x 6 CBL, SITC 42662- Meters 3300 995423 Yes SUPPLY AND LAYING OF 6 SQ.MM PVC INSULATED COPPER CONDUCTOR OF APPROVED MAKE (COLOUR CODING WILL BE DECIDED BY ENGINEER). 133 1C x 10 CBL, SITC 42662- Meters 200 995423 Yes SUPPLY AND LAYING OF 10 SQ.MM PVC INSULATED COPPER CONDUCTOR OF APPROVED MAKE (COLOUR CODING WILL BE DECIDED BY ENGINEER). 134 1C x 16 CBL, SITC 42662- Meters 200 995423 Yes SUPPLY AND LAYING OF 16 SQ.MM PVC INSULATED COPPER CONDUCTOR OF APPROVED MAKE (COLOUR CODING WILL BE DECIDED BY ENGINEER). 135 1C x 25 CBL, SITC 42662- Meters 20 995423 Yes SUPPLY AND LAYING OF 25 SQ.MM PVC INSULATED COPPER CONDUCTOR OF APPROVED MAKE (COLOUR CODING WILL BE DECIDED BY ENGINEER). 136 1C x 120 CBL, SITC 42662- Meters 10 Yes SUP. OF 1C X 120 SQ MM, CU,PVC- FOR DETAILED DESCRIPTION, REFER SCHEDULE OF QUANTITIES 137 SITC OF 8 SWG solid GI wire 42662- Running Meter 100 995461 Yes EARTHING, SUPPLY AND INSTALLATION OF 8 SWG GI/COPPER STRIP AND WIRE. 138 SITC OF 10 mm (3/8”) GI wire 42662- Meters 100 Yes CONNECTING INDIVIDUAL EQUIPMENT TO THE EARTH STRIP OR EARTH PLATE WITH FOLLOWING SIZES OF G.I. WIRE / G.I. WIRE ROPE INCLUDING THE SUPPLY OF G.I. WIRE /G.I. WIRE ROPE, LUGS, CONDUCTORS, CONNECTING TO THE G.I. STRIP OR EARTH PLATE AND NECESSARY HARDWARE FO 139 SITC OF 16 mm (5/8”)GI WIRE 42662- Meters 100 Yes CONNECTING INDIVIDUAL EQUIPMENT TO THE EARTH STRIP OR EARTH PLATE WITH FOLLOWING SIZES OF G.I. WIRE / G.I. WIRE ROPE INCLUDING THE SUPPLY OF G.I. WIRE /G.I. WIRE ROPE, LUGS, CONDUCTORS, CONNECTING TO THE G.I. STRIP OR EARTH PLATE AND NECESSARY HARDWARE FO 140 SITC OF 25mm x 3mm GI strip 42662- Meters 2200 995424 Yes INSTALL 25 X 3 MM GI STRIP: EARTH CONDUCTOR MATERIAL (REF. DRG. 272261-500-ELE-A1-4802): EARTH CONDUCTORS FOR EQUIPMENT EARTHING, INSTALLATION AND CONNECTION OF FOLLOWING GI EARTHING STRIP AND CABLE ALONG THE CABLE TRENCHES/CABLE TRAYS OR FIXING TO WALLS OR STRUCTURES OR LAYING INDIVIDUALLY IN PAVED/UNPAVED AREAS. INCLUDING WELDING AT JOINTS, PROVIDING ANTI-CORROSIVE PAINT OR BITUMEN COMPOUND FOR WELDED PORTION, CLAMPING AND NECESSARY HARDWARE FOR CONNECTING, ETC. INCLUDING ALL LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS SPECIFICATIONS DOCUMENT NUMBER 2272261-500-SP-ELE-007 AND STANDARD EARTHING INSTALLATION DRAWING NUMBER 272261-500-ELE-A1-4802 OR OTHER RELEVANT DOCUMENTS ATTACHED WITH TENDER, APPROVED DRAWING AND DIRECTIONS OF ENGINEER-IN-CHARGE. 141 SITC OF 40mm x 5mm GI strip 42662- Meters 150 Yes HOT DIP GALVANIZED G.I. EARTH STRIPS WITH MIN 100 MICRON COATING:40MM X 5MM GI.STRIP. 142 SITC OF 50mm x 10mm GI strip 42662- Meters 3500 995424 Yes SUPPLYING AND LAYING OF 50 X 10 MM GALVANIZED IRON STRIP: SUPPLYING AND LAYING OF GALVANIZED IRON STRIP AT 0.50 METRE BELOW GROUND AS STRIP EARTH ELECTRODE, INCLUDING CONNECTION/TERMINATING WITH GALVANIZED IRON. NUT, BOLT, SPRING, WASHER ETC. AS REQUIRED. (JOINTING SHALL BE DONE BY OVERLAPPING AND WITH 2 SETS OF GALVANIZED IRON NUT BOLT AND SPRING WASHER SPACED AT 50 MM). 143 SITC IF GI EARTH PIT 42662- Each 81 995461 Yes SUPPLYING AND MAKING OF GI PIPE EARTH PIT AS PER IS-3043 AND ENCLOSED DRAWING. 144 SITC IF CU EARTH PIT 42662- Each 36 995428 Yes BUILDING EARTHING COPPER EARTH PITS: CONSTRUCTION OF EARTH PIT FOR BUILDING EARTHING SYSTEM WITH COPPER ELECTRODE AS PER LATEST EDITION OF IS: 3043 AND AS PER DRAWING GIVEN IN THE TENDER SPECIFICATIONS. SCOPE INCLUDES EXCAVATION, SUPPLY AND INSTALLATION OF COPPER ELECTRODE, SUPPLY AND FILLING IN LAYERS FOR CHARCOAL AND SALT, PCC AND BRICK WORK IN CEMENT MORTAR, EARTH PIT RESISTANCE MEASURING, CEMENT MORTAR (1:4 CEMENT SAND RATIO) PLASTER WORK AND CURING. JOB INCLUDES ALL TOOLS, TACKLES, MACHINERY, POWER, CONSUMABLES, MANPOWER, SUPERVISION. RESISTANCE OF INDIVIDUAL EARTH PIT SHALL NOT EXCEED 4 OHM. IN CASE SAME EXCEEDS 4 OHM, SUITABLE CORRECTIVE ACTION SHALL BE TAKEN BY CONTRACTOR AT HIS OWN COST TO BRING DOWN SAME TO ACCEPTABLE LIMIT. JOBS AND WORKS SHALL BE CARRIED OUT WITH GOOD ENGINEERING PRACTICE, AS PER CODES AND STANDARDS, TENDER SPECIFICATION AND DIRECTION OF HPCL. 145 S,ITC of 700mmAir term Rod 42662- Each 10 995461 Yes PROVIDING, SUPPLYING AND INSTALLATION OF LIGHTNING ARRESTOR WITH COPPER ROD. 146 S,ITC of 4000mmAir term Rod 42662- Each 6 995461 Yes PROVIDING, SUPPLYING AND INSTALLATION OF LIGHTNING ARRESTOR WITH COPPER ROD. 147 Sup, ITC of Clamps 42662- Each 10 Yes SUPPLY INSTALLATION, TESTING AND COMMISSIONING OF CLAMP: CLAMPS TO HOLD AIR TERMINATION ROD. 148 S,ITC of Roof Conductor 42662- Meters 1640 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF ROOF CONDUCTOR: 8 MM AL ROOF CONDUCTOR. DIAMETER CONDUCTOR-8 MM, CROSS-SECTION-50 MM2, MATERIAL-ALMGSI, STANDARD EN 62561-2. 149 S,ITC of Roof Holder 42662- Each 1640 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF ROOF HOLDER: CONDUCTOR HOLDER OF STAINLESS STEEL FOR RD 8-10 MM H 20 MM WITH FEMALE THREAD M8 PRE-ASSEMBLED WITH PLASTIC BASE. WITH ACCESSORIES SCREW AND GITTY, MATERIAL STAINLESS STEEL. 150 SUP,ITC OF Conductor Holder 42662- Each 1 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CONDUCTOR HOLDER: CONDUCTOR HOLDER WITH SLOTTED CLEAT FOR FIXING OF ROUND CONDUCTORS, FIXED CONDUCTOR LEADING. MATERIAL OF CONDUCTOR HOLDER- STST, CONDUCTOR HOLDER SUPPORT RD- 8-10 MM, CONDUCTOR HOLDER SUPPORT FL- 20 MM, HEIGHT OF CONDUCTOR HOLDER-20 MM. 151 S,ITC of Unidersal Con 42662- Each 75 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF UNIVERSAL CONNECTOR: UNIVERSAL CONNECTOR FOR INTERCONNECTING ROOF CONDUCTOR AND DOWN CONDUCTOR, MATERIAL OF CLAMP STAINLESS STEEL, CLAMPING RANGE RD 8-10 MM. 152 S,ITC of Expansion Piece 42662- Each 85 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF EXPANSION PIECES AT EVERY 20-METER DISTANCE. 153 S,ITC of down conductor 42662- Meters 395 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF DOWN CONDUCTOR: 8 MM ALUMINIUM DOWN CONDUCTOR. DIAMETER CONDUCTOR-8 MM, CROSS-SECTION-50 MM2, MATERIAL-ALMGSI, STANDARD EN 62561-2. 154 S,ITC of conductor holder 42662- Each 395 Yes SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF CONDUCTOR HOLDER: CONDUCTOR HOLDER WITH SLOTTED CLEAT FOR FIXING OF ROUND CONDUCTORS, FIXED CONDUCTOR LEADING. MATERIAL OF CONDUCTOR HOLDER- STST, CONDUCTOR HOLDER SUPPORT RD- 8-10 MM, CONDUCTOR HOLDER SUPPORT FL- 20 MM, HEIGHT OF CONDUCTOR HOLDER-20 MM. 155 S,ITC of Light counter 42662- Each 5 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF LIGHTNING COUNTER: LIGHTNING STRIKE COUNTER FOR DIGITAL RECORDING OF IMPULSE CURRENTS. THE DEVICE IS PREFERABLY INSTALLED ON THE DOWN CONDUCTORS OF THE LIGHTNING PROTECTION SYSTEM. OPERATING CURRENT (8/20 MICRO S):1 KA, MAXIMUM DISCHARGE CURRENT (10/350 MICRO S):100 KA, CLAMPING RANGE OF ROD:8-10 MM, CLAMPING RANGE OF FLAT:30 MM, DEGREE OF PROTECTION:IP 65. 156 SPLY AND INSTLN OF CLAMP 42662- Each 49 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF UNI DISCONNECTING CLAMP: UNI DISCONNECTING CLAMP WITH INTERMEDIATE PLATE FOR ROUND AND FLAT CONDUCTOR, MATERIAL STAINLESS STEEL, CLAMPING RANGE RD/FL 8-10/30 MM, EN 50164-1. | - | Each |
| 157 | S,ITC of 50mm Tray | S,ITC of 50mm Tray — CABLE TRAY; TYPE:N/A; MATERIAL:GALVANISED IRON; DIMENSION:50 MM; WITH ZINC BATH CONCENTRATION AS PER IS 2629 AND IS 4759 | - | Running Meter |
| 158 | S,ITC of 100mm Tray | S,ITC of 100mm Tray — CABLE TRAY; TYPE:N/A; MATERIAL:GALVANISED IRON; DIMENSION:100 MM; WITH ZINC BATH CONCENTRATION AS PER IS 2629 AND IS 4759 | - | Running Meter |
| 159 | S,ITC of 150mm Tray | S,ITC of 150mm Tray — CABLE TRAY; TYPE:LADDER STRAIGHT RUN; MATERIAL:GALVANISED; DIMENSION:150 MM; STRAIGHT LENGTH:3 M | - | Meters |
| 160 | S,ITC of 300mm Tray | S,ITC of 300mm Tray — CABLE TRAY; TYPE:LADDER STRAIGHT RUN; MATERIAL:GALVANISED IRON; DIMENSION:300 MM; STRAIGHT LENGTH:3 METRE 161 S,ITC of 450mm Tray 42662- Running Meter 10 Yes CABLE TRAY; TYPE:LADDER; MATERIAL:GALVANISED IRON; DIMENSION:WD: 450 MM; WITH ZINC BATH CONCENTRATION AS PER IS 2629 AND IS 4759 | - | Meters |
| 162 | S,ITC of 600mm Tray | S,ITC of 600mm Tray — CABLE TRAY; TYPE:LADDER STRAIGHT RUN; MATERIAL:GALVANISED IRON; DIMENSION:600 MM; STRAIGHT LENGTH:3 METRE 163 S,ITC of 900mm Tray HC 42662- Meters 160 995461 Yes SUPPLYING AND INSTALLING 900 MM WIDTH X 62.5 MM DEPTH X 2 MM THICKNESS SIZE OF PERFORATED HOT DIPPED GALVANIZED IRON CABLE TRAY (GALVANIZATION THICKNESS NOT LESS THAN 50 MICRONS) WITH PERFORATION NOT MORE THAN 17.5 %, IN CONVENIENT SECTIONS, JOINED WITH CONNECTORS, SUSPENDED FROM THE CEILING WITH GALVANIZED IRON SUSPENDERS INCLUDING GALVANIZED IRON BOLTS AND NUTS, ETC. AS REQUIRED. 164 S,ITC of 1000mm Tray HC 42662- Running Meter 120 Yes SUPPLY AND FIXING OF CABLE TRAY. REFER ATTACHMENT FOR SIZE. 165 S,ITC of 600mm Tray HC 42662- Each 10 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF TRAY FITTING: HORIZONTAL CROSS FOR 600 MM WIDE CABLE TRAY GALVANIZED IRON, 2 MM THICKNESS, 100 MM HEIGHT LADDER CABLE TRAY WITH ACCESSORIES. 166 S,ITC of 300mm Tray TEE 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 167 S,ITC of 600mm Tray TEE 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 168 S,ITC of 300mm Tray ELBOW 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 169 S,ITC of 600mm Tray ELBOW 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 170 S,ITC of 600mm Tray V ELBOW 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 171 S,ITC of 300mm Tray V ELBOW 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 172 S,ITC, 45 Deg 1000MM tray 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 173 SITC.45 Deg 300MM tray 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 174 SITC,TEE 1000-900-1000 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 175 SITC,TEE 1000-600-1000 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 176 SITC,TEE 1000-300-1000 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 177 SITC,TEE 900-600-900 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 178 SITC,TEE 900-300-900 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 179 SITC,TEE 300-300-300 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 180 SITC,TEE 300-900-300 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 181 SITC,Reducer 1000-900 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 182 SITC,Reducer 600-300 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 183 SITC,Reducer 300-1000 42662- Each 20 Yes SUPPLY,ITC OF CABLE TRAY FITTINGS AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 184 1Cx300SM, CABLE LAYING 42662- Meters 1300 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 185 2Cx4 SM, CABLE LAYING 42662- Meters 90 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 186 2Cx6 SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 187 2Cx10 SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 188 2Cx16 SM, CABLE LAYING 42662- Meters 95 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 189 3Cx2.5 SM, CABLE LAYING 42662- Meters 8160 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3CX2.5 SQ. MM (CU) 190 3Cx4 SM, CABLE LAYING 42662- Meters 100 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3CX4 SQ. MM (CU) 191 3Cx6 SM, CABLE LAYING 42662- Meters 100 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 192 4Cx10 SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 193 3.5Cx16 SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 194 3.5Cx25 SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 195 3.5Cx35SM, CABLE LAYING 42662- Meters 225 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 196 4Cx2.5SM, CABLE LAYING 42662- Meters 1183 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:4CX2.5 SQ. MM (CU) 197 4Cx4SM, CABLE LAYING 42662- Meters 22987 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:4CX4 SQ. MM (CU) 198 4Cx6SM, CABLE LAYING 42662- Meters 11399 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:4CX6 SQ. MM (CU) 199 4Cx10SM, CABLE LAYING 42662- Meters 3951 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:4CX10 SQ. MM (CU) 200 4Cx16 SM, CABLE LAYING 42662- Meters 2396 Yes LAYING OF CABLE IN INSTALLED CABLE TRAY AND FIXING IT WITH ALUMINIUM STRIP. 201 3.5Cx25SM, CABLE LAYING 42662- Meters 4720 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX25 SQ. MM (AL) 202 3.5Cx35SM, CABLE LAYING 42662- Meters 3341 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX35 SQ. MM (AL) 203 3.5Cx50SM, CABLE LAYING 42662- Meters 1600 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX50 SQ. MM (AL) 204 3.5Cx70SM, CABLE LAYING 42662- Meters 2700 Yes LAYING OF CABLE IN INSTALLED CABLE TRAY AND FIXING IT WITH ALUMINIUM STRIP. 205 3.5Cx95SM, CABLE LAYING 42662- Meters 2350 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX95 SQ. MM (AL) 206 3.5Cx120SM, CABLE LAYING 42662- Meters 1200 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX120 SQ. MM (AL) 207 3.5Cx150SM, CABLE LAYING 42662- Meters 1000 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 208 3.5Cx185SM, CABLE LAYING 42662- Meters 1350 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS POWER CABLE OF FOLLOWING SIZES:3.5CX185 SQ. MM (AL) 209 3.5Cx240SM, CABLE LAYING 42662- Meters 50 Yes LAYING OF CABLE IN INSTALLED CABLE TRAY AND FIXING IT WITH ALUMINIUM STRIP. 210 5Cx2.5SM, CABLE LAYING 42662- Meters 31920 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS CONTROL CABLE OF FOLLOWING SIZES.5CX2.5 SQ. MM (CU) 211 7Cx2.5SM, CABLE LAYING 42662- Meters 2500 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS CONTROL CABLE OF FOLLOWING SIZES.7CX2.5 SQ. MM (CU) 212 9Cx2.5SM, CABLE LAYING 42662- Meters 2845 Yes LAYING OF CABLE AS PER TECHNICAL SPECIFICATION AND DETAILED DESCRIPTION PROVIDED IN SOQ 213 12Cx2.5 SM, CABLE LAYING 42662- Meters 100 Yes HORIZONTAL AND VERTICAL LAYING OF FRLS , XLPE CABLES OF FOLLOWING SIZES AND PARTICULARS ON CABLE RACKS, RCC TRENCHES, BURIED TRENCH , FLOOR SLITS, IN G.I. CONDUIT (INCLUDING CHIPPING OF FLOOR WHEREVER REQUIRED), ON CABLE TRAYS, CABLE RACKS, CABLE RISERS, SUPPORTS, HANGERS, SADDLES ETC., SEALING OF WALL OPENINGS AND PIPE SLEEVES AFTER CABLE LAYING ETC., INCLUDING HANDLING, TRANSPORTATION FROM OWNER'S STORE/STORAGE YARD TO INSTALLATION SITE OF CABLES/CABLE DRUMS, UNPACKING , INSPECTION, CABLE DRESSING, FIXING OF CABLE CLAMPS IN VERTICAL AND IF NECESSARY IN HORIZONTAL RUNS, FIXING OF CABLE IDENTIFICATION TAGS (AT EVERY 20 MTR. INTERVAL ALL ALONG THE LENGTH); TESTING BEFORE AND AFTER LAYING; SUPPLY OF ALUMINUM CABLE CLAMPS AND CABLE TAGS, GI SADDLES AND GI SADDLE BARS ,PROVIDING CABLE ROUTE MARKER FOR BURIED CABLE TRENCHES, GI BOLTS, NUTS AND WASHER SCREWS ETC., ACTUAL SITE MEASUREMENT SHALL BE TAKEN BEFORE CUTTING THE CABLE FROM DRUM TO AVOID CABLE JOINT / WASTE,MEASUREMENT OF IR VALUE, TESTING OF CABLES BEFORE AND AFTER TERMINATIONS FOR IR VALUES, ALL WORK, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE.1.1 KV GRADE XLPE INSULATED,ARMOURED, FRLS CONTROL CABLE OF FOLLOWING SIZES.12CX2.5 SQ.MM (CU) 214 SITC of Gland 1/2" 42662- Each 185 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 215 SITC of Gland 3/4" 42662- Each 84 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 216 SITC of Gland 1" 42662- Each 104 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 217 SITC of Gland 1 1/2" 42662- Each 20 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 218 SITC of Gland 1.25" 42662- Each 20 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 219 SITC of Plug 1 1/2" NPTM 42662- Each 80 Yes CABLE GLAND & PLUGSSUPPLY & INSTALLTION CABLE GLAND PVC SHROUD FROM APPROVED VENDOR LIST, TECHNICAL SPPECIFICATION & DETAILED DESCRIPTION PROVIDED IN SOQ 220 SITC of 25mm counduit 42662- Meters 1000 Yes CLASS-B ,GALVANIZED IRON (G.I. PIPES) CONFORMING TO IS-1239 COMPLETE WITH ACCESSORIES (BENDS, REDUCERS, COUPLERS ETC.) OF FOLLOWING SIZES:25 MM NB 221 SITC of 50mm counduit 42662- Meters 500 Yes CLASS-B ,GALVANIZED IRON (G.I. PIPES) CONFORMING TO IS-1239 COMPLETE WITH ACCESSORIES (BENDS, REDUCERS, COUPLERS ETC.) OF FOLLOWING SIZES:50 MM NB 222 Laying of 1px1.5sm cable 42662- Meters 2000 995424 Yes LAYING OF 1PX1.5 SQMM FRLS SIGNAL CABLE. 223 Laying of 2px1.5sm cable 42662- Meters 500 995424 Yes LAYING OF 2PX1.5 SQMM FRLS SIGNAL CABLE. 224 Laying of 4px1.5sm cable 42662- Meters 500 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 225 Lay of 1Tx1.5sm cable 42662- Running Meter 500 Yes LAYING OF 1 TRIAD X 1.5 SQ.MM (BLUE), PVC INSULATED ARMOURED, FRLS, PVC SHEATHED, OVERALL SHIELDED, SIGNAL CABLE. 226 Lay of 12Tx1.5sm cable 42662- Running Meter 600 Yes LAYING OF 12 TRIAD X 1.5 SQ.MM (BLACK) OVERALL SHIELDED, ARMOURED, FRLS PVC, CONTROL CABLE. 227 Lay of 10Px1.5sm cable 42662- Meters 500 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 228 Lay of 12Px1.5sm cable 42662- Running Meter 1000 Yes LAYING OF 12 PAIR X 1.5 SQ.MM (LIGHT BLUE) PVC INSULATED ARMOURED CABLE, FRLS, PVC SHEATHED, INDIVIDUAL AND OVERALL SHIELDED, SIGNAL CABLE. 229 Lay of 20Px1.5sm cable 42662- Meters 500 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 230 Lay of 24Px1.5sm cable 42662- Meters 500 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 231 Lay of 6Px1.5sm cable 42662- Running Meter 2000 Yes LAYING OF 6 PAIR X 1.5 SQ.MM (LIGHT BLUE) PVC INSULATED ARMOURED, FRLS, PVC SHEATHED, INDIVIDUAL AND OVERALL SHIELDED, SIGNAL CABLE. 232 Lay of 6Cx1.5sm cable 42662- Meters 1800 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 233 Lay of 2Cx1.5sm cable 42662- Meters 2000 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 234 Lay of 3Cx1.5sm cable 42662- Meters 1000 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 235 Lay of 16Cx1.5sm cable 42662- Meters 1500 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 236 Laying of OFC cable 42662- Meters 1000 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 237 Laying of Netw cable 42662- Meters 400 Yes INSTALLATION OF INSTRUMENT CABLES -RECEIVING, HANDLING, LOADING, UNLOADING, UNPACKING, TRANSPORTING FROM STORAGE POINT OR ANY OTHER LOCATION WITHIN THE PROJECT SITE, LAYING (BRANCH CABLE, HOME RUN CABLE, DIRECT RUN CABLE ETC.), GLANDING, TERMINATION AT B 238 ITC of VCB 42662- Each 1 Yes INSTALLATION OF 11 KV HT VCB PANEL, INSTALLATION, TESTING AND COMMISSIONING OF 11KV, 25KA, 800A, 3 PH, 50HZ INDOOR PANEL VACUUM CIRCUIT BREAKER (SHROUDED VACUUM BOLT) WITH SUITABLE POWER PACK, 110V DC MOTOR OPERATED SPRING CHARGED MECHANISM, ANTI-PUMPING DEVICE, 24V DC SHUNT TRIP AND CLOSING COIL, MECHANICAL OPERATION COUNTER, 4 NO + 4 NC AUX. CONTACT WITH CONTACT MULTIPLICATION CONTACTOR, AUTOMATIC SAFETY SHUTTER, MECHANICAL CLOSE/TRIP KNOB, MECHANICAL ON/OFF INDICATION, OPERATING HANDLE. THE PANEL SHALL BE TOTALLY ENCLOSED, FREE STANDING, FLOOR MOUNTING, DUST AND VERMIN PROOF, INDOOR CUBICAL TYPE, IP42, MADE OF 14SWG SHEET STEEL POWDER COATED WITH NECESSARY CABLE ALLEY AND BUS BAR CHAMBER. THE PANEL SHALL BE WITH 800A ALUMINIUM BUS BAR AND SUPPORT INSULATORS, SPACE HEATER WITH THERMOSTAT, CUBICLE ILLUMINATION LAMP, MCBS FOR AC/DC CONTROL ETC, CONTROL WIRING ETC. THE PANEL ALSO CONSISTS OF 11KV, 25 KA FOR 3 SEC, 800A-1 NO, 3 NOS OF RESIN CAST 1 PH, PTS 11KV/V3/110 V /V3, 50VA(MINIMUM) CLASS 0.5, DRAW OUT TYPE COMPLETE WITH HT FUSE ON PRIMARY AND MCB ON SECONDARY SIDE-1 SET, 3 NOS OF RESIN CAST CURRENT TRANSFORMER OF 100/5A DUAL CORE (CORE 1-15VA CLASS 0.5 FOR METERING AND CORE 2-15VA 5P10 FOR PROTECTION)-1 SET, 3 NOS OF AMMETER ANALOG TYPE (0 TO 100 A)-1 SETSVOLTMETER (0-15 KV) ANALOG TYPE WITH SELECTOR SWITCH-1 SETS DIGITAL POWER ANALYZER SUITABLE FOR MEASURING V, A, F, KW, KVA, KVAR, KWH WITH RS 485 COMMUNICATION FACILITY (APPROVED MAKE)-1 SETS, 3 PH NUMERICAL RELAY WITH THREE OVER CURRENT AND ONE EARTH FAULT PROTECTION WITH HIGH SET ELEMENT AND RS 485 COMMUNICATION PORT-1 SETS, MASTER TRIP AND TRIP SUPERVISION RELAY-1 SET, LED TYPE INDICATION LAMPS FOR BREAKER ON/OFF AUTO TRIP/SPRING CHARGED AND R, Y, B PHASE INDICATION-1 SET, 12 WINDOW ANNUNCIATION-1 NO, TNC BREAKER CONTROL SWITCH-1 NO, THE PANEL SHALL BE WITH BOTTOM ENTRY TO RECEIVE INCOMING AND OUTGOING CABLE, ALL NECESSARY INTERCONNECTION AND ACCESSORIES AS PER PARTICULAR SPECIFICATION AND SINGLE LINE DIAGRAM. 239 ITC of MCC01 42662- Each 1 Yes INSTALLATION, ERECTION, TESTING AND COMMISSIONING OF FREE ISSUED ELECTRICAL ITEMS FROM HPCL-MCC PANEL RECEIVING FROM STORE, TRANSPORTING TO ERECTION SITE EXCLUDING CABLE GANGLAND AND POWER/CONTROL CABLE TERMINATION BUT INCLUDING HANDLING, ARRANGEMENT OF TRANSPORT VEHICLE, LOADING AND UNLOADING EQUIPMENT LIKE CRANE, SLINGS ETC, PLACING ON FOUNDATION, FIXING ON FOUNDATION CHANNELS, ALIGNING, LEVELING ETC. ASSEMBLING OF ALL ACCESSORIES/PARTS SUPPLIED LOOSE, BUS DUCT CONNECTION, CONNECTION OF AUXILIARY CIRCUITS, OPERATION AND FUNCTIONAL CHECKING, TESTING AND COMMISSIONING OF FOLLOWING HPCL ISSUED TRANSFORMER/PANEL AND OTHER ELECTRICAL ITEMS TOGETHER WITH ITS ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS AND DOCUMENTS, SPECIFICATIONS, CODES AND STANDARDS AND INSTRUCTIONS/DIRECTIONS OF ENGINEER-IN-CHARGE. 240 ITC of MCC02 42662- Each 1 Yes INSTALLATION, ERECTION, TESTING AND COMMISSIONING OF FREE ISSUED ELECTRICAL ITEMS FROM HPCL-MCC PANEL RECEIVING FROM STORE, TRANSPORTING TO ERECTION SITE EXCLUDING CABLE GANGLAND AND POWER/CONTROL CABLE TERMINATION BUT INCLUDING HANDLING, ARRANGEMENT OF TRANSPORT VEHICLE, LOADING AND UNLOADING EQUIPMENT LIKE CRANE, SLINGS ETC, PLACING ON FOUNDATION, FIXING ON FOUNDATION CHANNELS, ALIGNING, LEVELING ETC. ASSEMBLING OF ALL ACCESSORIES/PARTS SUPPLIED LOOSE, BUS DUCT CONNECTION, CONNECTION OF AUXILIARY CIRCUITS, OPERATION AND FUNCTIONAL CHECKING, TESTING AND COMMISSIONING OF FOLLOWING HPCL ISSUED TRANSFORMER/PANEL AND OTHER ELECTRICAL ITEMS TOGETHER WITH ITS ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS AND DOCUMENTS, SPECIFICATIONS, CODES AND STANDARDS AND INSTRUCTIONS/DIRECTIONS OF ENGINEER-IN-CHARGE. 241 ITC of PMCC 01 42662- Each 1 Yes INSTALLATION, ERECTION, TESTING AND COMMISSIONING OF FREE ISSUED ELECTRICAL ITEMS FROM HPCL-PCC PANEL RECEIVING FROM STORE, TRANSPORTING TO ERECTION SITE EXCLUDING CABLE GANGLAND AND POWER/CONTROL CABLE TERMINATION BUT INCLUDING HANDLING, ARRANGEMENT OF TRANSPORT VEHICLE, LOADING AND UNLOADING EQUIPMENT LIKE CRANE, SLINGS ETC, PLACING ON FOUNDATION, FIXING ON FOUNDATION CHANNELS, ALIGNING, LEVELING ETC. ASSEMBLING OF ALL ACCESSORIES/PARTS SUPPLIED LOOSE, BUS DUCT CONNECTION, CONNECTION OF AUXILIARY CIRCUITS, OPERATION AND FUNCTIONAL CHECKING, TESTING AND COMMISSIONING OF FOLLOWING HPCL ISSUED TRANSFORMER/PANEL AND OTHER ELECTRICAL ITEMS TOGETHER WITH ITS ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS AND DOCUMENTS, SPECIFICATIONS, CODES AND STANDARDS AND INSTRUCTIONS/DIRECTIONS OF ENGINEER-IN-CHARGE. 242 ITC of PDB-1 42662- Each 1 Yes INSTALLATION, TESTING, COMMISSIONING OF DISTRIBUTION BOARD: PDB-01, 415 V, TPN, 50 HZ, 400 A AND 200 A, 25 KA/1 SEC INCOMER, INDUSTRIAL, INDOOR TYPE, IP42, SINGLE FRONT, FIXED TYPE, FLOOR MOUNTED, POWER DISTRIBUTION BOARDS AS PER MV SINGLE LINE DIAGRAM 11387- 12-ELE-SLD-0003. 243 ITC DB-01 42662- Each 1 Yes SUPPLY, INSTALLATION ,TESTING AND COMMISSIONG OF DB AS PER TECHNCIAL SPECIFICATION AND DESCRIPTION PROVIDED IN SOQ. 244 ITC of APFC 42662- Each 1 Yes TRANSPORATION TO THE ERECTION SITE, INSTALLATION, TESTING AND COMMISSIONING OF SHEET STEEL ENCLOSED, FLOOR MOUNTING, FREE STANDING, CUBICLE TYPE FOLLOWING SWITCH BOARDS EXCLUDING GLANDING AND TERMINATIONS OF POWER , CONTROL & INTERFACING CABLES ,HANDLING, TRANSPORTATION FROM OWNER’S STORE/ STORAGE YARD TO ERECTION SITE BY ALL REQUIRED VEHICLE/CRANE ETC, UNPACKING AND INSPECTION, DRESSING OF FOUNDATION AS REQUIRED, FLOOR CUTTING & CHIPPING AS REQUIRED,ASSEMBLY OF TRANSPORTATION SECTIONS/PANELS, ALIGNING, LEVELING, BUS BAR BOLTING BETWEEN TRANSPORTATION SECTIONS, FIXING IN POSITION ON BASE CHANNEL GROUTED LEVEL IN FOUNDATION FLOOR OR DIRECTLY ON LEVEL FLOOR FOUNDATION BY BOLTING ETC., INTER PANEL WIRING AND EARTH CONNECTIONS, MOUNTING IN POSITION AND WIRING/CONNECTION OF LOOSE COMPONENTS/ ACCESSORIES E.G. RELAYS, METERS, CTS, PTS, ETC., DRILLING OF GLAND PLATES AS PER REQUIRED HOLES OR ENLARGING OF EXISTING HOLES FOR CABLE ENTRIES, FIXING OF CABLE GLANDS AND TERMINALS SUPPLIED LOOSE, PLUGGING OF ALL UNUSED ENTRIES AND OTHER HOLES IN PANELS TO MAKE THE SAME AND THE ENTIRE SWITCH BOARDS DUST AND VERMIN PROOF, MINOR REPAIR AND TOUCH UP PAINTING WORK, OPERATIONAL AND FUNCTIONAL CHECKING,TESTING OF RELAYS, THERMAL OVERLOAD RELAY,AUX. RELAYS, RELAY SETTING,CALIBRATION OF METERS,TESTING OF BREAKERS,INSULATION RESISTANCE ETC, MINOR WIRING MODIFICATION, SUPPLY OF FOUNDATION BOLTS, NUTS AND WASHERS AND OTHER NECESSARY HARD WARES AND CIVIL MASONRY MATERIALS, ALL WORK, LABOUR AND MATERIAL COMPLETE AS PER DRAWINGS AND DOCUMENTS, SPECIFICATIONS, CODES AND STANDARDS AND DIRECTIONS OF ENGINEER-IN-CHARGE:CAPACITOR PANEL:415 VOLT, 3PH-N, 50HZ, 630A, 50KA FOR 1 SEC. 300KVAR CAPACITOR PANEL WITH ALL REQUIRED ACCESSORIES. 245 ESCADA 42662- Each 1 Yes SUPPLY OF ESCADA TO COLLECT AND ANALYSE THE SWITCHGEAR SYSTEM DATA | - | Meters |
| 246 | ITC of Transformer | ITC of Transformer — TRANSFORMER,LOW VOLTAGE; TYPE:INDUSTRIAL DISTRIBUTION; PHASE:3; FREQUENCY:50HZ; VOLTAGE,INPUT:11000; VOLTAGE,OUTPUT:433 V; POWER,RATED:800 KVA; TYPE,COOLING:OIL NATURAL & AIR NATURAL; WINDING MATERIAL:TPC COPPER WITH 99.9% PURITY; VECTOR GROUP:DYN 11; TYPE OF INSTALLATION:OUTDOOR; LAMINATION:LASER SCRIBED CORE; CONNECTION OF HV / LV:DELTA / STAR; TAPINGS:+5 % TO -15% IN THE STEP OF 2.5%; TEMPERATURE RISE:50° C /55° C ABOVE AMBIENT OIL /WINDING; REF . STAND.:IS 2026; LOSSES SHALL BE AS PER IS 1180.HV TERMINAL:CABLE BOX; LV TERMINAL:PROVISION FOR CONNECTING BUS DUCT; TAP CIRCUIT:ON CIRCUIT TAP CHANGE. | - | Each |
| 247 | ITC RTCC | ITC RTCC — ITEM DESCRIPTION:TAP INDICATOR METER; TYPE:N/A; RANGE:N/A; DIMENSION:N/A; MODEL:N/A; MANUFACTURER:VOLTAMP; ADDITIONAL INFORMATION:RTCC PANEL 248 ITC of 750KVA DG 42662- Each 1 998732 Yes INSTALLATION, TESTING AND COMMISSIONING OF 750 KVA DG SET SHIFTING FROM CLIENT'S STORE AND ERECTION ON FOUNDATIONS (INCLUDING CONSTRUCTION OF FOUNDATION), ASSEMBLING OF ALL LOOSE SUPPLIED ACCESSORIES AND INSTALLATION OF DIESEL GENERATOR IN COORDINATION WITH THE DG VENDOR. PRE-COMMISSIONING OF THE DG SET WITH DUE CO-ORDINATION WITH THE DG SUPPLIER AND FINAL COMMISSIONING OF THE SAME. STRUCTURAL SUPPORT SUPPLY AND FABRICATION SHALL BE PAID SEPARATELY UNDER RESPECTIVE ITEM. JOB TO BE EXECUTED AS PER ATTACHED TECHNICAL SPECIFICATIONS AND AS DIRECTED BY ENGINEER-IN-CHARGE COMPLETE. SCOPE INCLUDE DESIGNING, SUPPLYING AND ERECTION OF CHIMNEY AS PER CPCB-II NORMS. STRUCTURAL STEEL WORK WILL BE PAID UNDER RELEVANT ITEM FOR THIS WORK.1) CARRY OUT THE FOLLOWING TESTS UNDER SUPERVISION OF DG SET OEM (THE VISIT OF DG SET OEM SHALL BE ARRANGED BY HPCL). VENDOR TO PROVIDE NECESSARY TOOLS, MANPOWER, ETC. TO FACILITATE THE BELOW MENTIONED TEST. A) AUTOMATIC MAINS FAILURE CUM AUTO START OPERATION OF DIESEL GENERATING SET AND LOAD TRANSFER TO D.G BUS.B) THE ELECTRICAL VENDOR SHALL EXECUTE THE FOLLOWING TEST AT SITE IN THE PRESENCE OF THE CLIENT'S REPRESENTATIVE BEFORE ENERGIZATION AS PER INSTRUCTION FROM DG SUPPLIER. C) CHECKING THE ALIGNMENT BY ENGINE MANUFACTURER'S REPRESENTATIVE AND OBTAINING APPROVAL. D) INSULATION RESISTANCE TEST ON ALTERNATOR, CONTROL PANEL AND CABLING/BUS BAR TRUNKING. E) CHECKING THE ENGINE SAFETY FOR SATISFACTORY OPERATION. F) CHECKING VIBRATION LEVELS.G) TESTING OF INDIVIDUAL PROTECTIVE DEVICE ON ENGINE AND ALTERNATOR AND ENSURING THAT THE WIRING IS CARRIED OUT PROPERLY.H) FULL LOAD RUNNING FOR 8 HOURS CONTINUOUSLY. ALL THE READINGS SHALL BE LOGGED TO EVALUATE THE FUEL CONSUMPTION, LUBE OIL PRESSURE, WATER AND OIL TEMPERATURE VIS-A-VIS THE ELECTRICAL LOADI) THE DG SET SHALL BE DEEMED TO BE COMMISSIONED AFTER SATISFACTORY PERFORMANCE OF ALL ASSOCIATED EQUIPMENT.J) LAYING, WRAPPING UP WITH INSULATION OF THE EXHAUST PIPING SYSTEM.K) INSTALLATION OF THE EXHAUST AND FUEL SYSTEM OF THE PIPING.L) STATUTORY APPROVAL OF DG SET.M) CIVIL FOUNDATION OF DG SET. (CLIENT SCOPE) 249 ITC of AMF Panel 42662- Each 1 Yes INSTALLATION, TESTING, COMMISSIONING OF AMF PANEL: AMF PANEL AND BATTERY CHARGER PANEL. 250 ITC of 160KVA DG 42662- Each 1 998732 Yes DIESEL GENERATOR SET: INSTALLATION OF 415 V, 3 PHASE, 0.8 P.F. EMERGENCY STANDBY POWER RATING (AS PER ISO 8528-1) DIESEL GENERATOR SET IN ACOUSTIC ENCLOSURE, COMPLETE WITH ALL THE AUXILIARIES, CONTROL AND PROTECTION PANELS, EXHAUST SYSTEM, PIPING, CABLING,ETC. AS PER ATTACHED SPECIFICATION. 415 V, 3 PHASE (TPN), 4 WIRE, 0.8 P.F, ABOVE 100 UPTO 250 KVA. 251 ITC of AMF Panel 42662- Each 1 Yes INSTALLATION, TESTING, COMMISSIONING OF AMF PANEL: AMF PANEL AND BATTERY CHARGER PANEL. 252 TC of High Mast 42662- Each 7 995468 Yes TESTING AND COMMISSIONING OF THE HIGH MAST POLE WITH LUMINARIES. 253 S,Fab of Structural steel 42662- Metric Ton 10 Yes SHOP FABRICATION AT A SHOP APPROVED BY HPCL INCLUDING SUPPLY, FABRICATION AND WELDING AND TRANSPORTATION FROM SHOP TO HPCL SITE WITH LOADING AND UNLOADING.SUPPLYING, STRUCTURAL STEEL WORK WITH STRUCTURAL/ TUBES OR APPROVED EQUIVALENT TUBULAR STEEL AND PIPES CONFIRMING TO IS 1161 FOR COLUMNS, PORTALS, BRACINGS, TRUSSES, PURLOINS, RAFTERS, ETC. INCLUDING GUSSET PLATES, HOLDING DOWN BOLTS, ANCHOR PLATES ETC, INCLUDING SITE AND SHOP FASTENERS, BOLTING, WELDING AT SHOP OR WORK SITE AT ALL HEIGHTS ETC. COMPLETE. NOTE: THE WEIGHT OF STEEL WORK FOR THE SAKE OF PAYMENT SHALL BE CALCULATED BY LINEAR MEASUREMENTS AND UNIT WEIGHTS TAKEN FROM THE RELEVANT BIS CODE, STANDARD STEEL TABLE BASED ON APPROVED STRUCTURAL DRAWINGS WITHOUT MAKING ANY DEDUCTIONS FOR HOLES, BEVEL ENDS, OR EDGE BEVELING OF PLATES. GUSSET PLATES SHALL BE PAID FOR THE MINIMUM RECTANGLE ENVELOPING THEIR ACTUAL PERIPHERY. PACKING CUT PIECES OF PLATES ETC. PROVIDED IN THE BASE PLATE OF COLUMN FOR LEVELING ETC. SHALL NOT BE MEASURED AND PAID SEPARATELY. STRUCTURAL, FABRICATION DRAWING TO BE SUBMITTED BY THE CONTRACTOR FOR APPROVAL OF CONSULTANT/ENGINEER IN-CHARGE. AS REQUIRED, CLEANING AND PREPARATION OF ALL STEEL SURFACES TO SWEDISH STANDARD SA 2-1/2 WITH COPPER SLAG BLASTING. THE PRIMER PAINT SHALL BE ONE COAT OF 65 MICRON INORGANIC ZINC SILICATE FOLLOWED BY ONE COAT OF 100 MICRON HB MIO FOLLOWED BY TWO COATS OF ACRYLIC POLYURETHANE EACH OF 40 MICRONS. FINISHING COAT SHALL BE APPLIED ONE BEFORE ERECTION AND ONE COAT AFTER ERECTION. TOTAL THICKNESS OF PAINT SHALL BE MINIMUM 245 MICRONS DFT. 254 Excavation of soil 42662- Cubic Meters 2500 Yes EXCAVATION OF ALL TYPE OF SOILS INCLUDING BREAKING OF CONCRETE,CUTTING OF ROAD ETC AS PER DIRECTION OF ENGINEER-IN- CHARGE.JOB INCLUDES REMOVAL OF EXTRA SOIL AND TRANSPORATION OF THE SAME AT LOCATION SUGGESTED BY ENGINEER-IN-CHARGE WITH ALL REQUIRED MAN POWER,VEHICLE ETC. 255 Backfilling of Soil 42662- Cubic Meters 1500 995431 Yes 256 Sand Filling in cable trench 42662- Cubic Meters 750 Yes SAND FILLING -SUPPLY & LAYING AS PER ATTACHMENT. 257 75mm thick Brick laying for ca 42662- Square Meters 250 Yes SUPPLY AND SPREADING OF APPROVED SECOND CLASS BRICKS OF 75 MM THICKNESS IN CABLE TRENCHES FOR CABLE PROTECTION, INCLUDING ALL LABOUR AND MATERIALS, AS PER APPROVED DRAWINGS, SPECIFICATIONS AND DIRECTIONS OF ENGINEER-IN CHARGE. (ACTUAL PLAN AREA OF LAID BR 258 TC of 0.37KW to 3.7KW motor 42662- Each 92 Yes MOTOR IS ERECTED BY MECHANICAL CONTRACTOR AT ERECTION SITE. HOWEVER, SCOPE OF ELECTRICAL CONTRACTORS IS EXCLUDING CABLE GLANDING & POWER / CONTROL CABLE TERMINATION BUT INCLUDING DEHYDRATION OF WINDINGS (IF REQUIRED), PLUGGING UNUSED CABLE GLAND CUTOUT IN MOTOR TERMINAL BOX, CHECKING & REPLENISHMENT / REPLACEMENT OF BEARING GREASE / LUBRICANT, CHECKING OF IR VALUES BETWEEN EACH WINDING & MOTOR FRAME, CHECKING OF CONTINUITY OF MOTOR WINDINGS, CHECKING OF DIRECTION OF ROTATION, MOTOR SHALL RUN IN UNCOUPLED CONDITION FOR 8 HRS. & CHANGING OF DIRECTION OF ROTATION (IF REQUIRED BY CHANGING SUPPLY CONNECTIONS), TRIAL RUNS ON NO - LOAD & LOAD TEST, SUPPLY OF APPROVED GREASE / LUBRICANT, INSTALLING OF CANOPY, NECESSARY HARDWARE’S, TESTING & COMMISSIONING OF FOLLOWING LT MOTORS TOGETHER WITH ALL ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS & DOCUMENTS, SPECIFICATIONS, CODES & STANDARDS AND INSTRUCTIONS / DIRECTIONS OF ENGINEER-IN-CHARGE. (CONTACTOR TO KEEP PROPER RECORD OF TESTS ON MOTORD FOR NO - LOAD & ON - LOAD RUNS.)0.37 KW TO 3.7 KW. 259 TC of 5.5KW to 22KW motor 42662- Each 22 Yes MOTOR IS ERECTED BY MECHANICAL CONTRACTOR AT ERECTION SITE. HOWEVER, SCOPE OF ELECTRICAL CONTRACTORS IS EXCLUDING CABLE GLANDING & POWER / CONTROL CABLE TERMINATION BUT INCLUDING DEHYDRATION OF WINDINGS (IF REQUIRED), PLUGGING UNUSED CABLE GLAND CUTOUT IN MOTOR TERMINAL BOX, CHECKING & REPLENISHMENT / REPLACEMENT OF BEARING GREASE / LUBRICANT, CHECKING OF IR VALUES BETWEEN EACH WINDING & MOTOR FRAME, CHECKING OF CONTINUITY OF MOTOR WINDINGS, CHECKING OF DIRECTION OF ROTATION, MOTOR SHALL RUN IN UNCOUPLED CONDITION FOR 8 HRS. & CHANGING OF DIRECTION OF ROTATION (IF REQUIRED BY CHANGING SUPPLY CONNECTIONS), TRIAL RUNS ON NO - LOAD & LOAD TEST, SUPPLY OF APPROVED GREASE / LUBRICANT, INSTALLING OF CANOPY, NECESSARY HARDWARE’S, TESTING & COMMISSIONING OF FOLLOWING LT MOTORS TOGETHER WITH ALL ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS & DOCUMENTS, SPECIFICATIONS, CODES & STANDARDS AND INSTRUCTIONS / DIRECTIONS OF ENGINEER-IN-CHARGE. (CONTACTOR TO KEEP PROPER RECORD OF TESTS ON MOTORD FOR NO - LOAD & ON - LOAD RUNS.)5.5 KW TO 22 KW. 260 TC of 22KW to 75KW motor 42662- Each 5 Yes MOTOR IS ERECTED BY MECHANICAL CONTRACTOR AT ERECTION SITE. HOWEVER, SCOPE OF ELECTRICAL CONTRACTORS IS EXCLUDING CABLE GLANDING & POWER / CONTROL CABLE TERMINATION BUT INCLUDING DEHYDRATION OF WINDINGS (IF REQUIRED), PLUGGING UNUSED CABLE GLAND CUTOUT IN MOTOR TERMINAL BOX, CHECKING & REPLENISHMENT / REPLACEMENT OF BEARING GREASE / LUBRICANT, CHECKING OF IR VALUES BETWEEN EACH WINDING & MOTOR FRAME, CHECKING OF CONTINUITY OF MOTOR WINDINGS, CHECKING OF DIRECTION OF ROTATION, MOTOR SHALL RUN IN UNCOUPLED CONDITION FOR 8 HRS. & CHANGING OF DIRECTION OF ROTATION (IF REQUIRED BY CHANGING SUPPLY CONNECTIONS), TRIAL RUNS ON NO - LOAD & LOAD TEST, SUPPLY OF APPROVED GREASE / LUBRICANT, INSTALLING OF CANOPY, NECESSARY HARDWARE’S, TESTING & COMMISSIONING OF FOLLOWING LT MOTORS TOGETHER WITH ALL ACCESSORIES, ALL WORKS, LABOUR AND MATERIALS COMPLETE AS PER DRAWINGS & DOCUMENTS, SPECIFICATIONS, CODES & STANDARDS AND INSTRUCTIONS / DIRECTIONS OF ENGINEER-IN-CHARGE. (CONTACTOR TO KEEP PROPER RECORD OF TESTS ON MOTORD FOR NO - LOAD & ON - LOAD RUNS.)ABOVE 22 KW TO 75 KW. 261 S & L Insu Mat 11 kV 42662- Meters 3 Yes 11KV, 900 MM WIDE, ELECTRIC GRADE FLOOR RUBBER MAT (IN PIECES OF LENGTH NOT LESS THAN 2 MTRS.) CONFORMING TO IS:15652 & ISI MARKED. 262 S & L Insu Mat 1.1 kV 42662- Meters 50 Yes 1.1 KV, 900 MM WIDE, ELECTRIC GRADE FLOOR RUBBER MAT (IN PIECES OF LENGTH NOT LESS THAN 2 MTRS.) CONFORMING TO IS:15652 & ISI MARKED. 263 Sup of First Aid Bod 42662- Each 5 Yes SHOCK TREATMENT CHART ( LAMINATED TYPE) IN BILINGUAL LANGUAGE (HINDI & ENGLISH). 264 Sup of Caution Bod 11kV 42662- Each 2 Yes 11KV , DANGER NOTICE PLATE / CAUTION BOARD AS PER IS:2551. 265 Sup of Caution Bod 440V 42662- Each 20 Yes 415 V , DANGER NOTICE PLATE / CAUTION BOARD AS PER IS:2551. 266 Sup, ITC of sealing compound 42662- Kilograms 40 Yes SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF SEALING COMPOUND: APPLYING FIRE PROOF MATERIAL (GPG/FOAM TYPE FIRE PROOF SEALING COMPOUND) FOR SEALING CABLE ENTRIES. 267 Sup, Fire Bucket 42662- Each 3 Yes 4 NOS. G.I FIRE BUCKET (9 LITRE) AS PER IS:2546 FILLED WITH SAND, PAINTED WITH RED COLOUR ALONG WITH ITS STAND FOR HOLDING THE SAND BUCKET INCLUDING RAIN HOOD FOR SAND BUCKET. 268 Rubber Hand Glove 1.1kV Grade 42662- Set 2 Yes RUBBER HAND GLOVE OF 1.1KV GRADE AS PER IS:4770. 269 Rubber Hand Glove 11kV Grade 42662- Set 2 Yes RUBBER HAND GLOVE OF 11KV GRADE AS PER IEC60903. 270 ELECTRICAL STATUTORY 42662- Each 1 Yes APPROVAL CHARGES FOR OBTAINING APPROVAL FOR LOAD/ADDITIONAL LOAD AND MAXIMUM DEMAND REQUIRED FOR LPG BOTTLING PLANT FROM LOCAL AUTHORITY/STATE ELECTRICITY BOARD. THE JOB ALSO INCLUDES ALL LIASONING TO BE CARRIED OUT WITH STATE ELECTRICITY BOARD AUTHORITIES FOR OBTAINING NECESSARY APPROVAL FOR SANCTIONING OF POWER FOR SUCCESSFUL COMMISSIONING OF THE LPG BOTTLING PLANT.JOBS INCLUDES PREPARATION OF ALL REQUIRED DRAWINGS/DOCUMENTS FOR GETTING APPROVAL. 271 Prov Electrician 42662- Man Day 30 Yes AS PER TENDER SPECIFICATIONS 272 Insulator Tester 42662- Each 1 Yes ITEM DESCRIPTION:LT INSULATION TESTER; TYPE:DIGITAL, INDUSTRIAL; RANGE:N/A; DIMENSION:N/A; MODEL:N/A; MANUFACTURER:FLUKE/MEGGER/YOKOGAWA; UP TO 1000 V AND UP TO 100 G OHM, TEST VOLTAGES: 50 V, 100 V, 250 V, 500 V AND 1000 V, RESOLUTION: 0.1 V, CAT IV 600 V APPLICATIONS, 200 MA CONTINUITY, TEST VOLTAGE ACCURACY: ± 2%, SHORT CIRCUIT TEST CURRENT: 1 MA NOMINAL, POLARIZATION INDEX: 10/1 MINUTE RATIO, DIELECTRIC ABSORPTION RATIO: 60/30 SECOND RATIO, SAFETY COMPLIANCE TO IEC 61010-1, ACCESSORIES: BATTERY, POUCH, REMOTE PROBE, TEST-LEADS TEST PROBES ALLIGATOR CLIPS, HOLSTER AND USERS MANUAL 273 LV Megger 42662- Each 1 Yes SUPPLY AND TESTING OF LT MEGGER UP TO 1000 VOLT AT HPGRDC FOR MEASUREMENT OF INSULATION RESISTANCE ALONG WITH ALL ACCESSORIES, ALL COMPLETE AS PER THE DIRECTIONS OF ENGINEER-IN-CHARGE. 274 S,I&T 6mm thk Chequered Plate 42662- Square Meters 80 Yes SUPPLY OF 6 MM THICK CHEQUERED PLATE 275 SIZE:1 TO 1.5IN,TERMINATION 42662- Each 50 995461 Yes GLANDING OF CABLES TO THE INSTRUMENTS/PANELS/THERMOCOUPLES/JBS ETC. (INSTALLED/LAID BY OTHER CONTRACTOR) BY USING DOUBLE/SINGLE COMPRESSION GLANDS OF 1 INCH TO 1.5 INCH INCLUDING TERMINATION WITH LUGS AND FERRULES. SUPPLY OF FERRULE AND LUGS IS IN VENDOR'S SCOPE. 276 SIZE:0.5 TO 42662- Each 50 995461 Yes 0.75IN,TERMINATION GLANDING OF CABLES TO THE INSTRUMENTS/PANELS/THERMOCOUPLES/JBS ETC.(INSTALLED/LAID BY OTHER CONTRACTOR) BY USING DOUBLE/SINGLE COMPRESSION GLANDS OF 0.5 TO 0.75 INCH INCLUDING TERMINATION WITH LUGS AND FERRULES. SUPPLY OF FERRULE AND LUGS IS IN VENDOR'S SCOPE. 277 DES SPL 11 KV H POLE 42662- Set 1 Yes STRUCTURE H POLE STRUCTURE-DESIGN AND SUPPLY OF H-POLE STRUCTURE FOR 11 KV INCOMING POWER SUPPLY WITH GANG OPERATED ISOLATOR, D.O. FUSE WITH BASE, LIGHTNING ARRESTORS, INSULATOR, EARTHING, PADLOCKING AND OTHER ACCESSORIES AS PER ATTACHED SPECIFICATIONS. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
20000671-HD-10157.pdf
TENDER_DOCUMENT • 36.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .