Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC OPPOSITE GATE NO 2 NORTH BENGAL UNIVERSITY PO N B U DIST DARJEELING WB | DARJEELING | DARJEELING | WEST BENGAL | 734013 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹46.2 L+₹82,350.50 (1.82%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹47.3 L+₹1.9 L (4.25%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹47.6 L+₹2.3 L (4.99%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹47.8 L+₹2.5 L (5.46%)Rejected-Finance MAKARDHA PO MAKARDHA PS DOMJUR BANERJEEPARA WEST BENGAL 711409 | HOWRAH | WEST BENGAL | 711409 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Oct 2021, 6:00 pmClosed
GE Bengdubi
Bengdubi Military Station, PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/42 OF 2021-22 REPAIR / REPLACEMENT OF OLD UNSERVICABLE FITTINGS, DBS REMOVAL OF EARTHING EXTERNAL ELECTRIC SUPPLY WORKS INCLUDING LT PANELS/CABLES AT OTM MD ACCN AND VARIOUS LOCATION UNDER AGE E/M OF GE BENGDUBI MIL STN
2021_MES_475591_1
GE/BENG/42 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Bengdubi
MES Enlisted/ Un-enlisted contractor of E and above category b(i)
8 documents required · 8 mandatory
₹500
GE Bengdubi
₹90,000
Yes
30 Oct 2021
16 Sept 2021
16 Oct 2021
16 Sept 2021
13 Oct 2021
7 Oct 2021
18 Sept 2021 - 23 Sept 2021
Amount
SCHEDULE 'A'
Dismantling of ACSR or AAC conductor from service feeder or distributor span, complete all as specified and directed.
Taking out old / unserviceable damaged bending/broken existing steel /concrete pole of any size/length with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same from site complete all as specified and as directed. (Note : Dismantling of cross arms and insulators fixed with pole shall be measured and paid separately under relevant items of Sch 'A'/BoQ)
Dismantling cross arms of MS channels or angle sections etc, complete all as specified and directed.
Dismantling insulators any type any sizes complete all as specified and directed by Enge-in-Charge.
Supply, errection, fixing and testing of steel tubular swaged poles 9.0 metre long, type 410 SP-31 complete with cast iron base plate, final taper plug, bolts, nuts and screws, pole cap etc confirming to IS-2713 of 1980 including painting two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces and numbering to be done in black synthetic enamel paint complete all as specified and directed.
S&F digital Ammeter in replacement for measuring alternating current of range : 0 - 200 A flush type 96x96MM size complete all as specified and directed.
S&F digital Voltmeter in replacement for measuring alternating current voltage of range : Range 0-500 V flush type 96x96MM size complete all as specified and directed.
S&F in replacement LED indicator - R/Y/B/G 240 V AC complete all as specified and directed.
Repair to LT panel ot door /in door type including taking out old damaged / unservicable door hings and welding new hinges of size as per existing and providing one locking arrangement all as directed.
M&L for preparation of old rusted steel surface or feeder pillar box /LT panel of any size, applying one coat of synthetic enamel paint as per the existing pattern above the PCC and black paint on legs of feeder pillar/LT panel and re-writing panel number or location and cutting vegetation growth all around and on the feeder pillar box/panel board upto 1 mtr radius complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI strip protected by 40mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and as directed.
S&F in repairs MCCB 100 amps, 3 pole, 415 Volt adjustable type with breaking capacity 16 KA, 100% ICU including spreader terminals & connected accessories complete all as per directed and specified. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 160 amps, 3 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as per directed and specified. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 200 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as directed. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 250 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as directed. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 350 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as per directed and specified. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 400 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as directed. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 500 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as directed. (Make : Legrand / ABB / L&T)
S&F in repairs MCCB 630 amps, 4 pole, 415 Volt adjustable type with breaking capacity 36 KA, 100% ICU including spreader terminals & connected accessories complete all as directed. (Make : Legrand / ABB / L&T/ Havells)
S&F in repairs on load change over switch with side handle in sheet enclosure 200 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/Havells)
S&F in repairs on load change over switch with side handle in sheet enclosure 320 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/Havells)
S&F in repairs on load change over switch with side handle in sheet enclosure 400 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Havells)
S&F in repairs change over open execution type 200 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/Havells)
S&F in repairs on load change open execution type 250 Amps, 4 Pole, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/Havells)
S&F in repairs busbar chamber in sheet enclosure 100 Amps, TPN, 4 way, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Havells)
S&F in repairs busbar chamber in sheet enclosure 200 Amps, TPN, 4 way, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Havells)
S&F in repairs busbar chamber in sheet enclosure 400 Amps, TPN, 4 way, 415V, 50 Hz complete all as spcecified and directed. (Make : Legrand / ABB / L&T/ Havells)
Taking out the existing sheet metal loopin /loopout and S&F junction box made of polycarbonate with IP-65 protection of size of size 230mm x 170mm x 105mm, having terminals for termination of cable with necessary nuts and bolts, poly carbonate cable gland of 2 Nos including 01 No DIN rail for mounting of MC and 01 Nos of MCB SP 10 KA 6 Amps including fixing clamp of FI 50x6mm with necessary nuts and bolts complete all as directed. (Make : Hensel/Syntex)
S&F in repairs MCCB enclosure upto 250 Amps, 3 Pole, 415V, 50 Hz complete all as directed.
M&L for PCC (1:3:6) type D-2 with using 40 mm grade crushed stone aggregate as in beding of steel tubular poles (15 mm thick) with necessary form work (if required) complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 with using 20 mm grade crushed stone aggregate as in foundation, copping of steel tubular poles and stay with necessary form work i(f required) complete all as specified and directed.
Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed.
Ditto all as per item No. 34.00 here-in-before but exc 1.5 m and n.exc 3.0 m in depth.
Returning, filling in approved earth, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and as directed.
M&L for Sub Class 'B' Bricks,old size, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Relaying of old serviceable brick as in cable protection all as specified and directed.
Taking out old U/S underground LT cable of any sizes including bricks from excavated trenches/pipes for reuse after placing joint kit all as specified and directed. (Note ;- Excavation & RFR, segregation of cable cover/bricks shall be measured and paid seperately under respective items of Sch 'A'/BoQ)
Relaying of serviceable cable after detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 6 Sqmm 2 core to 16 Sqmm 2core including supply and fixing straight through joint kit complete all as specified and directed.
Relaying of serviceable cable after detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 25 Sqmm 3.5 core to 70 Sqmm 3.5core including supply and fixing straight through joint kit complete all as specified and directed.
Relaying of serviceable cable after detecting the fault and making straigth through jointing kit of LT 440 volt under ground system of LT feeder/location of size 95 Sqmm 3.5 core to 200 Sqmm 3.5core including supply and fixing straight through joint kit complete all as specified and directed.
Supply and laying XLPE insulated, armoured, Heavy duty electric cables with aluminium conductor 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches /Through pipes / ducts or on poles/ wall / floorjointing to O/H conductor, LT panels, main switch with cable size aluminium lugs and testing complete all as specified and directed. (Note ;- Excavation & RFR shall be measured and paid seperately under respective items of Sch 'A'/BoQ)
Ditto all as per item No. 45.00 here-in-before but 10 Sqmm 2 core
Ditto all as per item No. 45.00 here-in-before but 16 Sqmm 2 core
Ditto all as per item No. 45.00 here-in-before but 16 Sqmm 4 core
Ditto all as per item No. 45.00 here-in-before but 25 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 35 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 50 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 70 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 95 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 120 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 150 Sqmm 3.5 core
Ditto all as per item No. 45.00 here-in-before but 185 Sqmm 3.5 core
Material and labour for surface dressing averaging 15cm depth in soft/loose soil for cleaning and cutting/removal of green vegetation in and around the installations and removal of the soil outside of the installation including spreading thin layer of anti vegetation chemical to prevent abnormal growth of grass/bushes, complete all as specified and directed.
Cutting and trimming of tree branches of any girth all around the LT over head lines upto two mtr from all around the over head lines complete and removing the cut branches from site to a distance not exc 50 mtr, complete all as specified and directed.
Supply & fixing cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts and washers drilled for insulator bolts welding bending cold or hot in any shape or size as directed and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. (Make: TATA/SAIL)
Supply and fixing LT line polyproplene composite phase separators 2 line (bolted Type) at suitable spans conforming to IS 1445 all as specified and directed.
Supply and fixing LT line polyproplene composite phase separators 3 line (bolted Type) at suitable spans conforming to IS 1445 all as specified and directed.
Supply and fixing LT line polyproplene composite phase separators 4 line (bolted Type) at suitable spans conforming to IS 1445 all as specified and directed.
M&L for painting of LT steel tubular pole (9 mtr long) any type or size externally above foundation including all MS work with one coat of aluminium paint after scrapping / clearing well the existing surface complete all as specified and directed. (Note;- The above work includes painting of 03 nos black & 02 yellow bands with 30cm by fluorescent paint in alternate layers upto 1.5 metre height above foundation / plinth block)
M & L for painting of 9 m PCC pole with cement wash two coat by using the cement and two coat of aluminium paint over cross arms, clamp of any length and shape for LT overhead line including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three black & two yellow bends width 30 cm by fluorescent paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
M&L for repairs to main electrical panel at sub stations by tightning the all loose connections of the cable ends & replacing the damaged/US/burnt aluminium lugs of required sizes, insulating/secure the weak insulated portin of cable ends inside the panel by taping with good quality of insulation tape, clean the dust by air blower all as specified and directed.
M&L for stringing, ACSR conductor of required size for O/H lines, on LT poles, including binding wire, including taking down old ACSR Conductor complete all as specified & directed
Restringing of each OH conductor with to permissible sag rebinding to insulators with new wire where cut point jumpers to be higher size of the OH conductor all as per specified and directed.
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Bus bar Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- Incoming (a) Copper bus bar - 300 amps rating - 03 Nos. for phases and 150 amp rating - 01 No. for neutral
Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type Feeder pillar box 'Pedastal type' Confirming to IP 43, CPRI approved, factory fabricated & factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penal made out of suitable size angle iron, channel and fabricated from 3.15 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & including busbars made of pure copper duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitable earth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the pillar box in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with multistranded copper condutor FRLS with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply :- Incoming (a) Copper bus bar - 800 amps rating - 03 Nos. for phases and 400 amp rating - 01 No. for neutral
M&L for horizontal boring under the road below 1 mtr from the road surface and dia of hole not exc 100 mm without damaging the existing road getting out and disposal of soil to a distance not exceeding 50 m from the site of work all as specified and as directed.
S&F in repair of GI Pipe 40 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair of GI Pipe 50 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair of GI Pipe 80 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair of GI Pipe 100 mm light grade including fittings to poles/laid under road for protection of under ground cable including making good in disturb surfaces and sound coundition complete all as specified and as directed.
S&F in repair earth continuity conductor GI strip 25x4mm size all as specified and directed.
S&F in repair earth continuity conductor GI strip 32x6mm size all as specified and directed.
Taking down carefully existing copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators etc for reuse at site complete all as specified and directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
M&L for concealed point wiring One light point/one fan/light/exjaust/bell point controlled by one switch with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface all as specified and directed.
All as per item No 81.00 here-in-before but One 3 pin socket outlet, 5 Amp on independent board all as specified and directed.
All as per item No 81.00 here-in-before but One 3 pin socket outlet, 5 Amp on same board all as specified and directed.
All as per item No 81.00 here-in-before but one light point controlled by 2-way switch all as specified and directed.
All as per item No 81.00 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed.
M&L for point wiring One light point/one fan/light/exjaust/bell point controlled by one switch with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc complete all as specified abd directed.
All as per item No 86.00 here-in-before but one light point controlled by 2-way switch all as specified and directed.
All as per item No 86.00 here-in-before but One 3 pin socket outlet, 5 Amp on independent board all as specified and directed.
All as per item No 86.00 here-in-before but One 3 pin socket outlet, 5 Amp on same board all as specified and directed.
M&L for point wiring with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 2.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 2.5 sqmm size through and including PVC casing & caping (double lock) of suitable size with all necessary fittings, terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mm x 300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of one 15 Amp switches-sockets outlet independent complete all as specified and directed.
S&F Switch piano, flush button, 5/6 Amps, single pole, two way, 230 Volts complete all as specified and directed.
S&F Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed.
Fixing only Switch piano any type (as retrived against item No 80.00 here-in-before) complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amp complete all as specified and directed.
Fixing only Socket outlet 5 Amp any type(as retrived against item No 80.00 here-in-before) complete all as specified and directed.
S&F Switch socket combination 2 in 1, 5 Amp flush type complete all as specified and directed.
Fixing only Switch socket combination 2 in 1, 5 Amp flush type (as retrived against item No 80.00 here-in-before) complete all as specified and directed.
S&F Switch socket combination 5A/ 16A, 5 in 1 flush type complete all as specified and directed.
Fixing only Switch socket combination 5A/ 16A, 5 in 1 flush type (as retrived against item No 80.00 here-in-before) complete all as specified and directed.
S&F Bell push, flush type, 5 amp complete all as specified and directed.
Fixing only Bell push (as retrived against item No 80.00 here-in-before) complete all as specified and directed.
S&F Bell, AC, 230 Volts, single pole complete all as specified and directed.
S&F Ceiling rose, 3 way PVC insulated body complete all as specified and directed.
Fixing only Ceiling rose any type (as retrived against item Ser No 80.00 here-in-before)
S&F stepped socket type electronic fan regulator flush type (2-Module) complete all as specified and directed.
S&F stepped switch type electronic fan regulator flush type (2-Module) complete all as specified and directed.
S&F LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete all as specified and directed . Make Havells cat part no. LUMILINEBS18WLED865SPWH OR EQUIVALENT MODEL OF CG /Philips.
S&F LED Tube Light luminaries with high performance LED with driver 1 x 10W (2 Feet long, Cool day/Warm white) complete all as specified and directed .make:Havells CAT PART NO.LUMILINEBS9WLED865SPCWH or equivalent model of Philips/CG
S&F Decorative CITY 1 wall light fixture made up of Polycarbonate suitable for 9 W LED lamp (B22) includin 10W LED Bulb etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexiblecopper conductor cable with suitable size.(Make:- Havells model no.LHDL02160099 OR equivalent model of philips/CG.
S&F CFL light fitting,1x10W LED bulk head luminaries IP65, complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V,50HZ. make:Havells cat part no.RUGBYGENX10W or equivalent model of Philips/CG
S & F Building security LED light luminaire fitting 1X20 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clam made out of MS flat of size 25X3 mm , 4 nos Anchor Bolt of suitable size etc all as specified and as directed by the Engineer-in-charge . MAKE Havells cat part no. VILUMINA 20W or equivalent model of Philips/CG.
S&F Lamp holder , PVC / Polycarbonate type with back plate suitable for B22 lamp including 9 Watt LED Bulb complete all as specified and directed. Make: Havells, Model: PHHD015 or equivalent model of Philips / Bajaj /Surya
S&F 12W LED Round/Square surface mounted downlighter including suitable driver & all accessories to fixed on Ceiling/Wall all as specified & directed by Engr-in-Charge.make:Havells cat part GLOW DL REC RD 12W or Eqivalent model of Philips/CG
S&F 12W LED Round/Square recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed by Engr-in-Charge.make:Havells cat part GLOW DL SUR RD 12W or Equivalent model of Philips/CG
S&F 36W LED Square Type 2' x2' recessed mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed by Engr-in-Charge.Make:crompton cat part no.LCTLRN-36-FO-CDL or Equivalent model of Philips/havells.
S&F 36W LED Square Type 2' x2' surface mounted downlighter including suitable driver, cutting of False ceiling as required and all accessories for fixing arrangement all as specified & directed by Engr-in-Charge.make:Havells cat part no.PLANO SURFACE 2 X2 36W or Equivalent model of Philips/CG.
Fixing only serviceable light fitting any type (as retrived against item No 79.00 here-in-before) complete all as specified and directed.
Taking down of Old MCB DB / control box any type any size including MCBs and separating the serviceable MCB DBs and MCBs for reuse at site complete all as specified and directed.
S&F sheet metal enclosure for MCB, DBs, Vertical type, double door, phosphatised, Powder coated , Triple Pole and Neutral (TPN), fixed flush to wall , IP 30 and IK 08 Protection Grade, including adjustable type MCCB as incoming of capacity 100Amp,4 pole with breaking capacity 25kA, 4 way, Double door 415 Volts all as specified and as directed .Make:LEGRAND cat part no.IP54- 507753 or equivalent model of Havells/L&T/ABB.
S&F Sheet metal enclosure for MCB DB double door Triple pole & Neutral 4 way with common bus bar at incomming end. Make:Legrand/havells/L&T/ABB.
S&F Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end Make:Legrand/havells/L&T/ABB.
S&F Sheet metal enclosure for MCB DB double door single pole & Neutral 8 way with common bus bar at incomming end.Make:Legrand/havells/L&T/ABB.
S&F Sheet metal enclosure for MCB DB double door single pole & Neutral 4 way with common bus bar at incomming end.Make:Legrand/havells/L&T/ABB.
S&F Sheet metal enclosure for MCB DB Single door single pole & Neutral 2 way without busbar.Make:Legrand/havells/L&T/ABB.
Refixing of MCB DB any type complete all as specified and directed.
S&F MCB Four pole, 415 volts, 40-63 Amps, breaking capacity 10KA complete all as specified and directed. Make:- Legrand L&T/ C&S/ Indoasian
S&F MCB 'C' series Double pole 6 to 32 Amps, breaking capacity 10KA, complete all as specified and directed. Make: Legrand /L&T/ C&S/ Indoasian
S&F MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. Make: Legrand /L&T/ C&S/ Indoasian
Refixing of MCBs any size any type complete all as specified and directed.
Taking down of old Submain wiring upto 10 sqmm any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through PVC Conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
M&L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit complete all as specified and directed. Note :- (a) PVC Conduit / casing- caping shall be included in same rate. (b) For concealed sub-main wiring cutting chases will be measured & paid separately. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
S&F in replacement Modular Switch 1 way 6 A, 1 module complete all as specified and directed.
S&F in replacement Modular Switch 1 way 16 A, 1 module complete all as specified and directed.
S&F in replacement Modular Socket 6 A, 2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement Modular Regulator Step Type 120 watt, 2 module complete all as specified and directed.
S&F in replacement Modular Blank plate, 1 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 2 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 3 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 4 module complete all as specified and directed.
S&F in replacement Modular type White cover plate with frame 6 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 2 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 3 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 4 module complete all as specified and directed.
S&F in replacement Modular type Metal Flush box 6 module complete all as specified and directed.
S&F in replacement LED bedside light fitting with 180O swivel and in-built on-off switch as directed.Make:philips cat part no. 48042 3W or equivalent model of havells/CG.
S&F LED post top light 30/40 Watt as suitable including all accessories as specified and as directed. make:havells cat part no.RUBYPT25WLED830SSYMTOPC or equivalent model of philips/CG.
S&F in replacement MS Box in concealed of any type and any size complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 300 x 250 x 3 mm complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 250 x 150 x 3 mm complete all as specified and directed.
S&F in replacement PVC hylum sheet 3mm thik top cover of size 100 x 100 x 3 mm complete all as specified and directed.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 200 x 150 x 50 mm deep.
S&F in replacement PVC ractangular block for mounting switch/socket/MCB DB's with 3 mm thick plastic laminated sheet cover of size 175 x 100 x 50 mm deep.
S&F in replacement Single Pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 16/25Amp complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable PVC insulated Aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core 10 Sqmm cable flate or Circular complete all as specified and diercted. Make:polycab/finolex/Havells/plaza
S&F in repair analog timer switch, surface mounting as per sample for automatic operation of street light complete all as specified and directed.
S&F in repair contactor modular type with ON/OFF indicator and label holder 4 pole 230 V 40-63 Amps coil operating voltage 230 volt complete all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 47543.00 (refer Tender Srl Page No 47(R). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
Shree Ram Construction
CHAKRABORTY AND SONS
M/S Joy Construction
M/S Banerjee construction co
M/S G D CONSTRUCTION
M/S R. K. INDUSTRIES
M/S K M CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .