Tender Value
₹2.6 L
EMD Value
₹3,200
Closing Date
28 Apr 2025, 5:00 pmClosed
Staff Officer (EnM)
Office of the General Manager, Dipka Area, Ph. No. 9424141353
Installation of an additional transformer and re-organization of HT and LT overhead line for New MQ type at Pragati Nagar Colony under Dipka Area.
2025_SECL_334092_1
SECL/GM/DA/SO(EnM)/ e-tender/25-26/04 dtd-12/04/25
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Dipka Area
Please refer to tender documents
5 documents required · 5 mandatory
₹3,200
27 Jun 2025
15 Apr 2025
30 Apr 2025
15 Apr 2025
28 Apr 2025
16 Apr 2025
15 Apr 2025 - 22 Apr 2025
Amount
Erection/ replacement of damaged 10/ 11/ 13 mtr. long steel tubular poles including excavation of pole pit as per site conditions and grouting by cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) etc (0.38 cum each pole)
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Stringing of ACSR Rabbit conductor, including loading onto departmental vehicle, transporting to site and unloading, laying of conductor along route, stringing and binding on insulators and jumpering.
Supply, laying & stringing of 8 SWG GI wire earth
Fabrication of MS Channel/Angle/Flat for bracket or clamp as per requirement.
Supplying and fixing of MS nut, bolt of different size as required
Supply of GI wire & erection of cradle guarding wire between the span including binding of guard wire.
Supplying and erection of 100 mm X 65 mm pin insulator complete with G.I. Spindle and nuts etc. as required.
Supplying and erection of Shackle insulator (75 mm X 90 mm) with G.I. bolts and nuts and GI straps etc as required
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply & fixing of 11 KV, 400 Amp, 3 Phase Isolator
Note: The estimated cost is excluding CMPF @ 12% and CMPS @ 7%. These statutory payment as applicable shall be reimbursed to the contractor on production of proof of payment limited to the maximum likely number of workmen to be deployed per day is 06 nos.
Total impact of GST for the purpose of CTC
V R ENTERPRISES (BID ID -1150657)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .