Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹11.1 L+₹44,574.50 (4.19%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹11.8 L+₹1.2 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹12.0 L+₹1.4 L (13.1%)Rejected-Finance SHOP NO 2 JANKI PLAZA BHAGWAN MAHAVIR PATH KOPARGAON AHMEDNAGAR MAHARASHTRA 423 601 | KOPARGAON | AHMEDNAGAR | MAHARASHTRA | 423601 | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹14.4 L+₹3.8 L (35.6%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
27 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Vipin Kumar Singh
GE (S) Ahmednagar Military Engineer Services Ahmednagar 414002
PROVISION OF HARDSTANDING AT CT BN, PAVED AREA AT MAC GP AND RECHARGE PITS FOR DEFI OTM ACCN AT MIRC UNDER GE(S) AHMEDNAGAR
2021_MES_428568_1
8776/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AHMEDNAGAR
Class E Cat a(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹28,000
Yes
1 Apr 2021
6 Mar 2021
29 Mar 2021
6 Mar 2021
27 Mar 2021
12 Mar 2021
6 Mar 2021 - 12 Mar 2021
60 days
Amount
Surface excavation in hard/dense soil n exc. 30 cm deep and averaging 15 cm and getting out complete all as specified and directed.
Excavation over areas, n exc 1.50 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas, n exc 1.50 m deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas, exc 1.5 m but not exc. 3.00 m deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas, exc 3.00 m but not exc. 4.50 m deep and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas, exc 4.50 m but not exc. 6.00 m deep and getting out in hard / dense soil complete all as specified and directed.
Returning, filling including spreading, levelling watering and well ramming in layers not exc 25 cm as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Hardcore of gauge not exc 63 mm , deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface complete all as specified and directed.
Moorum filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate), 75 mm thick as in sub base of floors including form work where required complete all as specified and directed.
100 mm thick PCC 1:2:4, type B-1 (by using 20 mm graded aggregate) as in flooring laid in alternate bays each not exc. 2 sqm surface finished even and fair without using extra cement complete all as specified and as directed by Engr-in-charge.
Plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate), 100 mm thick as in sub base of floors including form work where required complete all as specified and directed.
Plain cement concrete 1:2:4, type B-2 (using 40 mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified.
Plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified.
Stone set flooring with stone setts of size 200 to 250 mm long, 150 to 200 mm wide and 150 mm deep and sides dressed; bedded in CM 1.3, 20 mm thick; joints grouted in CM 1:2 with an admixture of metallic hardener 5% by weight of cement and struck flush complete all as specified and directed.
Edge stones to flooring with stone setts of size 250 to 300 mm long x 150 to 200 mm wide and 450 mm deep and sides dressed; bedded in CM 1.3, 20 mm thick; joints grouted in CM 1:2 with an admixture of metallic hardener 5% by weight of cement and struck flush complete all as specified and directed.
Precast cement concrete solid block masonry using solid block of grade C-1 (1:3:6) exc 10 cm in width, built in CM 1:6 complete all as specified and direted.
Rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces surface finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge
Plain cement concrete1:2:4, type B1 using 20 mm graded aggregate as in copings, kneelers, splash stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work as required complete all as directed.
Loose filling with broken stone or boulders of gauge 80 to 150 mm in rain water harvesting pits complete all as specified and directed.
Loose filling with broken stone or boulders of gauge 40 to 80 mm in rain water harvesting pits complete all as specified and directed.
Loose filling with broken stone or boulders of gauge 20 to 30 mm in rain water harvesting pits complete all as specified and directed.
Sand filling with course sand/pea size gravel in rain water harvesting pits including spreading and levelling in layers n exc 25 cm thick complete all as specified and directed.
Reinforced cement concrete M-25 (design mix) using 20 mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs complete all as specified and directed by Engineer-in-Charge.
Precast reinforced cement concrete 1:2:4, type B1, using 20 mm graded aggregate as in manhole covers etc and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
Formwork to edges of concrete flats, treads and roofs n exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10 cm but n exc. 20 cm wide complete all as specified and directed.
TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified
TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified
Mild steel work as in bands, straps, supports or stays, clamps, hold fasts, rungs, hooks, handles, steps and simillar small articles conforming to FE 410-0 all as specified & directed by Engr-in-Charge.
Mild steel framed work as in grills and gratings etc. with end of bars shouldered and or rivetted or forged into spikes, framed guard bars, railing and similar work coforming to Fe 290, Gde-E-165 complete all as specified and directed.
Trial bore 9 inch dia upto loose strata below ground level in any kind of (strata) including hard stone / boulders for inserting perforated pipes complete all as directed by Engineer-in-charge.
Trial bore 165.1 mm dia (6.5 inch) upto 30.48 meters (100 feet) depth below ground level in any kind of soil strata including hard stone / boulders for inserting perforated pipes complete all as directed by Engineer-in-charge.
Trial bore 165.1 mm dia (6.5 inch) upto 60.96 meters to 91.44 meters (100 to 200 feet) depth below ground level in any kind of strata including hard stone / boulders for inserting perforated pipes complete all as directed by Engineer-in-charge.
Trial bore 165.1 mm dia (6.5 inch) upto 30.48 meters to 60.96 meters (200 to 300 feet) depth below ground level in any kind of strata including hard stone / boulders for inserting perforated pipes complete all as directed by Engineer-in-charge.
UPVC pipes 180 mm dia perfotated pipes including jointing with and including jointing material, fixed in bore holes complete all as specified and directed.
Ms. D.G. SHIRKE
MS. G.A. CONSTRUCTION
sunway associates
M/s Meher Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .