Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹10.0 L+₹11,289.60 (1.14%)Accepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L2 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
29 Jan 2022, 1:00 pmClosed
EEEnMHPI
OFFICE OF THE CHIEF ENGINEER WW THROUGH EE EnM HP-I DELHI JAL BOARD GOVT OF NCT OF DELHI HAIDERPUR WATER WORKS DELHI 110085
Improvement of power factor through standard make APFC Panels, fixed capacitor banks, and static capacitor banks installed at CWPH, Bawana WTP.
2022_DJB_215255_9
NIT 21
Open Tender
Miscellaneous Works
Works
30 days
Haiderpur WTP
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹19,800
5 Feb 2022
22 Jan 2022
29 Jan 2022
22 Jan 2022
29 Jan 2022
22 Jan 2022
RENOVATION OF 2 Nos. STANDARD MAKE APFC PANELS Dismantling of defective components like capacitors, relays, contactors, indication lightest. from 2 nos. APFC panels including dismantling of terminations, wirings, hardware etc. as required at site
Supply of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors in various stages of APFC panels as required at site -make standard
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/aluminium bus bars using necessary hardware, lugs, tapes etc. as required at site
Supply of microprocessor based, 12 step APFC relay with digital display of power factor and other parameters to replace defective relay for providing phased impulses to contactor coils on receipt of low or high-power factor signal from the control CT - make "standard"
Control wiring of APFC relay with multistrand copper wire of 1.5 mm sq. size from relay connectors to various contactor coils to replace defective / burnt out control wiring as required at site
Supply of contactors MNX40 or equivalent-make to replace defective contactors in various stages of APFC panels L&T/GE /Schneider
Supply of contactors MNX70 or equivalent make to replace defective contactors in various stages of APFC panels L&T/GE /Schneider
Supply of TP MCBs up to 63A rating to replace defective MCB of various stages of APFC panels-make L&T/Schneider/Havell’s
Supply of Indication lights of various colours to replace defective indication lights of various stages of APFC panels as required at site -make FTC/Vaishno/Teknik
Installation and connection of various components as described above in APFC panels using necessary hardware, mounting arrangement and termination with multistrand copper wires, lugs and tapes etc. as required at site
Servicing of panels including complete dusting of all components, decarbonising of contactor contacts, tightening of various connections, alignment of doors for proper fitment to prevent ingress of m moisture, dust and all types of vermin and touching of all rusted parts to prevent damage to the panel from further rusting etc., as required at site
Testing & commissioning of APFC panels as per required parameters including following: i. Meggering of all equipment for phase to phase, and phase to earth. ii. Programming of APFC relay for target power factor iii. All function tests iv. Monitoring of power factor
RENOVATION OF FIXED CAPACITORS OF MOTORS Dismantling of defective components like capacitors, fuses, MCBs etc. from fixed capacitor banks of motors including dismantling of terminations, wirings, hardware, as required at site
Supply of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors in various capacitor banks of motors as required at site -make standard
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/aluminium bus bars using necessary hardware, lugs, tapes etc. as required at site
Supply of 250 A, fuses to replace blown out fuses of various SFUs of capacitor banks of various motors - make L&T/Schneider/Havell's
Installation and connection of various components as described above in fixed capacitor banks of motors using necessary hardware, mounting arrangement and termination with multistrand copper wires, lugs and tapes etc. as required at site
RENOVATION OF STATIC CAPACITORS OF TRANSFORMERS Dismantling of defective components like capacitors, MCBs etc. from static capacitor banks of transformers including dismantling of terminations, wirings, hardware, as required at site
Supply of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device -make standard
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/aluminium bus bars using necessary hardware, lugs, tapes etc. as required at site
Supply of 250 A, fuses to replace blown out fuses of various SFUs of capacitor banks of various motors - make L&T/Schneider/Havell's
Installation and connection of various components as described above in fixed capacitor banks of motors using necessary hardware, mounting arrangement and termination with multistrand copper wires, lugs and tapes etc. as required at site
Premier Engineering Company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .