Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.1 LAccepted-Finance | 1 | Accepted-Finance L1 |
Tender Value
₹3.2 L
EMD Value
₹6,350
Closing Date
27 Jan 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-III/RZ/NZ
EEE-III/RZ/NZ
Improvement of Lighting arrangement in various parks of village Kirari and other area of ward no-42 under Rohini zone
2022_NDMC_102688_1
EEE-III/RZ/NZ/TC/2021-22/19.3
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ/NZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹6,350
3 Mar 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
27 Jan 2022
21 Jan 2022
180 days
Amount
Supply and Replacement of 15 watt LED Retrofit lamp including connections etc as required.
Supply and Replacement of 9/11/15/18 watt LED lamp including connections etc as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supply of XLPE insulated and PVC Sheathed Al conductor armoured cables conforming to IS-7098 (Part-I)/1976 as required. 2x 10 sqmm
Supply of XLPE insulated and PVC Sheathed Al conductor un -armoured cables conforming to IS-7098 (Part-I)/1976 as required. 2x 6 sqmm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm
P&F of water/weather proof junction /pole box made out of hot press moulded sheet moulding (SNC) compound fire retaradant (temp. resistance upto 200 C) of size 200 X 160 X 98 mm (NS) complete with Suitable arrangement for fixing of 2 nos of 6 to 32 amp one No SP-MCB(6to32Amp) & 63 amp Double pole Isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channel with 2 nos of MS clamp with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..direct in ground (75 cm below ground level)including excavation and refilling the trench but excluding sandcushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recessfor loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
SITC of 25 watt LED IP 65 post top fitting made of die cast aluminium spigot spun aluminium powder coated top cover and clear acrylic diffuser with high volatage protection low power LEDs connected in series and Prallel combination with better heat sink arrangement input voltage 160-260 volts AC 50 HZ AC ssupply power factor >0.95 luminous efficacy >100 Lm/wt CCT 5700K +_300K surge Protection not less than 10KV complete as reqd.
Supply and Replacement of 9/11/15/18 watt CFL Choke including connections etc as required.
Providing & laying in position M25 grade reinforced a cement concrete foundation of size suitable RCC(1:2:4) shallow foundation of size 1m(L) X 2m deep i/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bar of 12 mm -2100 long(approx) -16 nos and reinforcement of cold twisted bar of 8 mm-3700 mm (approx)- 13 nos (with 150 mm spacing) as required with Positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast Considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material plate as reqd suitable for 12 meter poles.
Dismantling/removing transportation and Erection of 12 mtr semi high mast pole by maintaining proper safety rules after removing the base ,stacking the poles at proper place and refilling the pit with loose earth and remaining all removal of malba by maintaining proper safety i.e use rope and crane while shifting the pole.
Foundation of pole of following length in brick ballast and ramming the foundation, finishing with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 3 metre and upto 4.5 metre
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .