| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.2 LAccepted-Finance | L-1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L-2₹36.6 L+₹1.4 L (3.97%)Rejected-Finance FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L-2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L-3₹36.9 L+₹1.7 L (4.69%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L-3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L-4₹38.8 L+₹3.6 L (10.2%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L-5₹41.9 L+₹6.7 L (19.1%)Rejected-Finance | L-5 | Rejected-Finance GREATER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
11 Nov 2020, 6:00 pmClosed
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
SPL REPAIRS TO ROOF TREATMENT OF BLDG NO. P213, P229, P230, P231 AND P254 AT SMQ AND BLDG NO. P308 TO P314 AT NSB AND BLDG NO P434 TO P437 OMA AT INS SHIVAJI LONAVLA
2020_MES_391250_1
GE/LONAVLA/8953/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹88,000
Yes
13 Nov 2020
30 Oct 2020
13 Nov 2020
30 Oct 2020
11 Nov 2020
6 Nov 2020
1 Nov 2020 - 5 Nov 2020
Amount
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , exc 500& not exc 1000 litrs tanks complete all as specified.
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , exc1000& not exc 2000 litrs tanks complete all as specified.
Taking down steel tubing and connections including all fittings 20 mm bore with all fittings and bends.
Taking down steel tubing and connections including all fittings 25 mm bore with all fittings and bends.
Demolition of RCC water tank ,chajja of any description and in any position not otherwise specifically provided rainforced (rainforcement of cut as required to facilasite demolition etc) complete all as specifed and directed.
Dismantling wrought iron or mild steel pipe work of any description and at any place complete all as specified and directed.
Removing Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris etc , complete all as specified and directed .
M/L for rendering 15 mm thick in cm 1:4 using readi plaster on external surface of brick walls or concrete roof surfaces mixed with water and all as per manufacturer instructions etc, finishing the surface even and smooth without using extra cement etc , complete all as specified and directed . Make:- Ultra Tech / Silico / Renaplast/Kaneria
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- (a) Apply one coat of bituminous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reniforcement weighing not less than 4.00 Kg/Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
M&L for making the grooves 25mm wide and 50mm deep to 'V' section in existing walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves, inserting chajja of PPGI sheet and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F for Tubes, ‘medium grade’ galvanised, 20 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
Ditto all as per item No 13 above but 25 mm bore.
S&F in repairs 1000 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed.
S&F in repairs 2000 ltrs Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed.
S&F framed work such as gates, grills gratings hooks and pintle hinges for large steel gates, railing etc encluding round headed screws or welding seams including bending or truning up mitred angles etc as required etc, with ends of bars shouldered and /or riveted or forged into spiles framed guard bars, barred iron doors, ladders framed balusters walk ways gates railings, rollers etc and similar work conforming to Fe-29 or Gde -E-165 and complete all as specified and directed.
S&F Roof trusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) all as specified and directed by Eng-in-Charge.
S&F Pre-painted galvatume aluminim zinc coating GI based corrugated steel sheet 0.50mmthick of any colour having tensile strength of 550 Mpa as in roof covering/chajjas fixed with slef tapping screws etc complete all as specified and directed.
M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F 16 to 20mm diameter of neck mild steel screws bolts any length (machine made) with hexagonal or square heads at one end and screwed the other ,or screwed both ends each screwed and to be fitted with washers and one hexagonal or square nut,n,exc.5cm etc complete all as specified and directed.
Complete removal of existing treatment of external surface of wall including removing fungus /algae dirt, oil, grease and loose particles by wire brush,cleaning, washing and removing dust, . Cracks less than 2 mm, should be cleaned free of dust with a vaccum cleaner and apply Dr. Fixit Primeseal (Efflorescence resistant penetrating primer.) let it dry. Then pour Dr. Fixit Raincoat into these cracks and wait for it to dry Apply the first coat of Dr. Fixit Raincoat without any dilution at the rate of 2 sqm per litre and allow it to dry before taking up the second and third coats, the rate of application being the same, Drying time between coats will be 6 to 8 hrs, A total thickness of 1 to 1.2 mm must be achieved when Dr. Fixit Raincoat is dry and including necessary scaffoldings etc , complete all as specified and directed Note:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
Dismantling loose/disintegrated portion of RCC Chajjas, sunshade & Roof Projection drop etc including necessary form work, scaffolding etc and dubbing with PCC (1 : 1.5 : 3) not exc 100mm thick using 6 to 12 thick graded stone aggregate in any broken/loose portion of RCC member and plastering in CM 1:3 in desired shape, including removing the waste material / debris etc , complete all as specified and directed. Note:- (i) This item is operative when only portion of RCC member is repaired and for the purpose of payment each member made good shall be measured. (ii) If reinforcement required for repair of chajja, sunshade & roof projectiom it will be paid separately.
S&F Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips on slab, MH cover etc. complete all as specified and directed by Engineer-in-charge.
Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bends nahani traps etc
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75 mm bore
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore
PVC (SWR) bends any radius 75 mm bore
PVC (SWR) bends any radius 110 mm bore
PVC (SWR) junction single, (Single Y) equal or unequal 75 mm bore
PVC (SWR) junction single, (Single Y) equal or unequal 110 mm bore
PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet 75 mm
DWARKESH STRUCT-CON
VIJAYA ENTERPRISES
M/s S.D Construction Co
RK AND SONS CREATION
SHAILENDRA B TULSANI
Mehta Construction Co.
Modern Engineering Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .