Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest and quoted rates are reasonable | |
| 2 | L2₹27.6 L+₹1.1 L (3.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.8 L+₹1.2 L (4.57%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹27.9 L+₹1.3 L (5.07%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹28.1 L+₹1.5 L (5.73%)Rejected-Finance PULGAON | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹52,720
Closing Date
1 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD CAMP- 442303
REPAIR/REPLACEMENT OF OLD EXISTING STREET LIGHT AND CONNECTED ITEMS OF DEPOT AND PERIMETER AREA UNDER GE PULGAON
2023_MES_635131_1
8064/PUL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹52,720
Yes
1 Apr 2024
4 Jan 2024
8 Feb 2024
4 Jan 2024
1 Feb 2024
19 Jan 2024
5 Jan 2024 - 18 Jan 2024
Amount
Disconnecting and taking down exiting unserviceable Street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. Repairing/replacing unserviceable parts refixing the same on pole/wall after testing and removing of carbon from line jumpers/Tightening of jumper/alligment of fitting defective street light/security light/flood lights fitting/LED light from electric pole complete all as directed by EIC. Note: (i) Spare parts and accessories such as LED Driver and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included under this item.
Supply only LED street light Driver for 45 Watts LED Street light complete all as specified and directed.
Supply only LED street light Driver for 60 Watts LED Street light/ Flood light type complete all as specified and directed.
Supply and fix in repair LED streetlight of 60 Watt, supply 240 Volt/50 Hz comprises of pressure die cast Aluminium, toughened glass, secondary optic lens distribution of light bat wing and having LED system efficiency>130 lumens/Watt , system efficancy >100 watt, lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 10KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand upto 440 v for 8 hr,IP 66 Protected,THD<10%,CRI>70CCT Natural white range (4600-6500K), PF>0.95/>0.98, Driver efficiency>85%,LM79 including 3 core 1.5 sqmm copper multi stranded wire of length not less than 1 mtr and accessories.Conforming IP-66 including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge. Make : Havells cat part No LHETAEU7PA7K060 or equivalent make in Crompton/Wipro/Phillips
Supply and fix in repair LED streetlight of 45 Watt, supply 240 Volt/50 Hz comprises of pressure die cast Aluminium, toughened glass, secondary optic lens distribution of light bat wing and having LED system efficiency>130 lumens/Watt , system efficancy >100 watt, lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 10KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand upto 440 v for 8 hr,IP 66 Protected,THD<10%,CRI>70CCT Natural white range (4600-6500K), PF>0.95/>0.98, Driver efficiency>85%,LM79 including 3 core 1.5 sqmm copper multi stranded wire of length not less than 1 mtr and accessories.Conforming IP-66 including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge Make : Havells cat part No LHETAEU7PA7K045 or equivalent make in Crompton/Wipro/Phillips
Supply and fix in repair LED Flood light of 100 Watt, supply 240 Volt/50 Hz comprises of pressure die cast Aluminium, toughened glass, secondary optic lens distribution of light bat wing and having LED system efficiency>130 lumens/Watt , system efficancy >100 watt, lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 10KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand upto 440 v for 8 hr,IP 66 Protected,THD<10%,CRI>70CCT Natural white range (4600-6500K), PF>0.95/>0.98, Driver efficiency>85%,LM79 including 3 core 1.5 sqmm copper multi stranded wire of length not less than 1 mtr and accessories.Conforming IP-66 including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge Make : Havells cat part No LHEPARU7P17J100 or equivalent make in Crompton/Wipro/Phillips
S&F in repair 1100 volts grade 2.5 Sqmm 3 core flat heavy duty cable PVC insulated,PVC sheathed with copper conductors, multistranded served with an inner sheathing of PVC tape and overall PVC sheathed including PVC connector of suitable size in service connections/street light connection including disconnection and removing the unserviceable cable.
S&F in replacement street light bracket made out of 25mm dia light grade pipe 1.2 mtr long bend to shape along with two FI clamp made out of 20 mm x 3mm including nut, bolt, washers all as directed and taking down the existing bracket.
Material and Labour Earthing complete with galvanised earth plate electrode 60cmx60cmx6.00 mm thick buried directly in ground nut less then 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nut check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to main switch distribution board complete and testing on completion all as specified and directed by Engr-in-charge. Note : The unit rate shall also includes for excavation and earth work, in/any type of soil, pit in PCC 1:3:6 type C1 funnel with watering pipe 20mm bore GI medium grade, earth lead protection pipe 40mm bore GI medium grade, RCC 1:2:4 type B1 cover for earrth chamber, 50mm thick with 8mm dia TMT bar 100mm C/C both ways & 6mm dia MS round bars as handles of cover slab all as specified. Note: Rate of GI earthing strip and GI Protection pipe upto 7.50m shall be included in unit quoted rate of this item.
Supply & Fix in repair steel tubing GI light grade 50mm bore for cable protection passing under Road/Floor or for fixing to poles all as specified and directed.
All as per item No. Above but GI Pipe of dia 40 mm dia
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole upto ground level complete all as directed by Engr-in-Chrage.
M & L PCC (1:3:6) type C-1 using 20 mm graded stone aggregate as in coping/plinth block including necessary form work all as directed by Engr-in-Chrage.
Road cutting for laying UG cable under road /railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dia and making it good to match with the adjoining surfaces/structure for after cable passing complete all as specified and directed. Note :- GI Pipe and PCC will be measured and paid against respective item.
M&L for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe and painting one coat of aluminium paint from 2.1 mtr above ground level to top of pole and cross arms and protection pipe and painting of bottom area of pole upto 2.1 mtr from ground level with synthetic enamel paint in alternate bay ( 30 cm wide) with black and yellow paint including writing poles numbers in white letter on black ground complete all as specified and directed by Engr-in-Charge.
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof/trenches complete all as directed by Engr-in-Chrage.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, watering, and well ramming complete all as directed by Engr-in-Chrage.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all as directed by Engr-in-Chrage.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches ,ducts for cable protection incliding levellling and consodilation complete all as specified and directed by EIC. Note : Punned thickness shall be measured.
ReLaying only old bricks/PCC Cover obtained from excavation complete as directed by Engr-in-Charge
Supply and laying brick sub class "B" having minimu compressive strength 75 kg/sqcm laid in trenches for cable protection etc complete all as directed by Engr-in-Chrage.
S and F in repair loop in / loop out box of internal size 250 x 200 x 100mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.SINTEX CAT PART NO. GSJB-2520 or equivalent in HENSEL / HANSU
S&F MCB TPN 63 amps 415 volts Complete all as specified and directed including taking out old one.
S&F MCB SPN 6-32 amps 230 volts Complete all as specified and directed including taking out old one.
Taking down existing cable from loop and pole including protection pipe, from pole/wall of any size including old clamps, juction box etc "for proper clamping,re-connecting cable and alignment of pipe with pole/wall " including proper looping and coping etc
I P Constructions
SHUBHAM SALES
SHRI RANI SATI TRADERS
M/S Maa Durga Constructions,Pulgaon
M/S. ELECTROPOWER TECHNOLOGIES
SHREE SIDDHIVINAYAK TRADERS
MAHARASHTRA ENTERPRISES
Rama Electricals
Bidder Name
Rama Electricals
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
MAHARASHTRA ENTERPRISES
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S. ELECTROPOWER TECHNOLOGIES
SHUBHAM SALES
I P Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .