Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance C 62 SHATABDI NAGAR ALIGARH UTTAR PRADESH 202001 | ALIGARH | ALIGARH | UTTAR PRADESH | 202001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 503 GROUND FLOOR SECTOR 4 VAISHALI GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 26 YASHODA KUNJ MAWANA ROAD MEERUT U P | MEERUT | MEERUT | UTTAR PRADESH | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹38.8 L
EMD Value
₹78,000
Closing Date
6 Oct 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
OFFICE OF THE CHIEF GENERAL MANAGER CandDS LUCKNOW
OFFICE OF THE CHIEF GENERAL MANAGER CONSTRUCTION and DESIGN SERVICES (E/M) NALKOOP WING UP JAL NIGAM LUCKNOW
Interconnection work of New Tube well to existing pipe line system and construction of Pump House cum Chlorination Room complete in all respect at Jai Bhim Nagar Meerut
2021_CDSNW_626088_1
1216 / Karya3 / 21/16 Dated 17/09/2021
Open Tender
Civil Works - Water Works
Item Rate
365 days
Meerut
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
Director CandDS E/M Nalkoop wing UP Jal Nigam
₹78,000
7 Oct 2021
30 Sept 2021
7 Oct 2021
30 Sept 2021
6 Oct 2021
30 Sept 2021
120 days
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 150 mm dia
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 250 mm dia
P/F S&S C.I. sluice valves/N.R.V Kirloskar make as per I.S :780-1960 complete with bolts nuts, rubber insertions etc 300 mm dia sluice valve (Kirloskar/IVC Make)
P/F S&S C.I. sluice valves/N.R.V Kirloskar make as per I.S :780-1960 complete with bolts nuts, rubber insertions etc 250 mm dia sluice valve (Kirloskar/IVC Make)
P/F S&S C.I. sluice valves/N.R.V Kirloskar make as per I.S :780-1960 complete with bolts nuts, rubber insertions etc 150 mm dia sluice valve (Kirloskar/IVC Make)
Providing and laying double flanged (screwed/welded) centrifugally (spun) cast iron class '' B '' (IS : 1536) pipe. 250 mm dia
Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS : 9523 upto 600mm dia.
Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :Over 300 mm dia
Providing and fixing of C.I. different size nut-bolt with washer
Supply and filling with jamuna sand over & below for proper cushion of CI pipe consolidating and dressing complete.
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 18.35.1 With common burnt clay F.P.S. bricks of class designation
Constructing masonry Chamber 100x100x120 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement 3 coars sand) 12 mm thick finished with a floating coat of near cement complete as per standard design
RCC Thurst block with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Reinforced cement concrete including supply of Reinforcement and all materials labour, T&P etc required for proper completion of work.
Mild steel or iron work in R.C.C. worth to required shape as necessery including bending for proper completion of the work including supply of steel & wastage etc.
Construction of Pump House cum Chlorination Room as per approved design of Meerut Nagar Nigam including Internal/External Electrification of pump house complete in all respect as per tender document.
SHREE JEE BUILDERS AND CONTRACTORS
Pioneer Drilling Company Pvt. Ltd.
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .