Karnataka Power Transmission Corporation Limited
AEE-2
Dismantling, Transportation (to and fro), Re-Conditioning/Repair, Testing, Erection and commissioning of sick Power Transformer of rating 31.5 MVA, 66/11KV, BBL make, Sl. No. 4934/20 Year of Manufacture 2006 lying at Banaswadi and failed at 66/11kVBanaswadistationon total turnkey basis
KPTCL/2023-24/EL/WORK_INDENT844/CALL-3
KPTCL/2023-24/EL/WORK_INDENT844/CALL-3
Open
Electrical
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Circle BMAZ North Bengaluru
20 documents required · 20 mandatory
The repairer participating in the tender for repair of Power Transformer shall be approved vendor for supply of minimum 33 KV Class and 5 MVA Capacity Transformer to Public Utilities with minimum 02 (TWO) years of experience in manufacturing/repairing, testing and commissioning of 33 KV Class 5 MVA or higher voltage class Transformer . The manufacturing unit/facility of the bidder shall be located within Karnataka State
The Bidder shall have necessary facilities at his own works for carrying out all routine tests mentioned in this specification including facility to carry out special tests namely Impulse Test and Temperature Rise Test on a repaired Power Transformer as prescribed in the latest IS:2026/1977or any relevant standard as applicable for testing of repaired Power Transformer. The testing facilities shall have testing and measuring instruments calibrated by National Accreditation Board for Testing and Calibration Laboratories (NABL). Valid calibration reports of Testing and measuring instruments shall be uploaded to the e-portal.
The Bidder shall have experience of minimum 05 (five) years in manufacturing / repairing, testing and commissioning of same or higher. voltage class of Power Transformer herein tendered involving designing, manufacturing and replacement of faulty windings in case of Power Transformer which has been repaired for any of the Government / public sector power utility in India which should have been in satisfactory continuous operation for at least 02 (two) years prior to the date of opening of the tender or The repairer participating in the tender for repair of Power Transformers shall be the approved vendor for supply of minimum 33kV Class and 5MVA capacity Transformers to Public Utilities with minimum 02 (Two) years of experience in manufacturing/repairing, testing and commissioning of 33kV Class 5 MVA or higher voltage class Transformers. The manufacturing unit facility of the bidder shall be located within Karnataka state
The Bidder should have executed either manufacture or repair on total turnkey basis (involving designing manufacturing and replacement of faulty windings of Power Transformer) of a same or higher voltage class in the past 05(five) years ending last day of the month previous to the one in which tender is invited for any of the Government public sector power utility for any one of the following value of work which shall have rendered satisfactory service of at least 02 (two) years continuously or The repairer participating in the tender for repair of Power Transformers shall be approved vendor for supply of minimum 33kV Class and 5MVA capacity Transformers to Public Utilities with minimum 02(Two) years of experience in manufacturing repairing, testing and commissioning of 33kV Class 5 MVA or higher voltage class Transformers. The manufacturing unit facility of the bidder shall be located within Karnataka state Applicable to 110kV and below voltage Class Power Transformers a) a minimum of 60 percent of the value of the tendered amount against each of 02 (two) distinct work orders on total turnkey basis or b) a minimum of 50 percent of the value of the tendered amount against each of 03 (three) distinct work orders on total turnkey basis or c)a minimum of 40 percent of the value of the tendered amount against each of 04 (four) distinct work orders on total turnkey basis. Clause (a), (b) and (c) as above will not be applicable if the bidder is a Vendor for supply of minimum 33kV Class and 5 MVA capacity Transformers to Public Utilities with minimum 02 (Two) years of experience in manufacturing repairing, testing and commissioning of 33kV Class 5 MVA or higher voltage class Transformers. The manufacturing unit facility of the bidder shall be located within Karnataka state. Applicable to 220kV and below voltage Class Power Transformers a) a minimum of 60percent of the value of the tendered amount against each of 02 (two) distinct work orders on total turnkey basis or b) a minimum of 50percent of the value of the tendered amount against each of 03 (three) distinct work orders on total turnkey basis.
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
The Bidder shall have necessary facilities at his own works for carrying out all routine tests mentioned in this specification including facility to carry out special tests namely Impulse Test and Temperature Rise Test on a repaired Power Transformer as prescribed in the latest IS:2026/1977or any relevant standard as applicable for testing of repaired Power Transformer. The testing facilities shall have testing and measuring instruments calibrated by National Accreditation Board for Testing and Calibration Laboratories (NABL). Valid calibration reports of Testing and measuring instruments shall be uploaded to the e-portal
List of works for which tenders already submitted
The Bidder should have their own repair shop with all the facility such as Crane, Oven, winding machines, etc., required for carrying out necessary repairs on Power Transformers.
The Bidder shall upload the proof of having possessed the above T&P equipment along with valid calibration certificate for testing / measuring equipment to the e-portal for verification
The Bidder should have established own workshop to accommodate and repair EHV Transformers, and should maintain dust free environment for winding works and should have the essential equipment
The performance of the Transformer repaired supplied by the Bidder in the past shall be a vital factor in determining the responsiveness of the tenderer. (In case bidder is a Vendor for supply of minimum 33kV Class and 5 MVA capacity Transformers to Public Utilities with minimum 02 (Two) years of experience in manufacturing repairing testing and commissioning of 33kV Class 5 MVA or higher voltage class Transformers. The manufacturing unit/facility of the bidder shall be located within Karnataka state, then the clause stated above is not applicable.)In case of substantial failure of the Transformers repaired / supplied by the Bidders in the past contracts, failure to adhere to the completion schedules or to meet the technical requirements and guarantees and, if the Transformer so repaired supplied and installed were affected by persistent operational problems, damages, breakdowns etc., owing to design inadequacies, workmanship defects etc., the Bids shall be rejected. Notwithstanding anything stated above, the Owner reserves the right to inspect the works to assess Bidders capability and capacity to perform the work, should the circumstances warrant such an assessment in the overall interest of the Owner
COMPANY REGISTRATION CERTIFICATE
The solvency required will be 100 % of the amount put to tender . The solvency certificate shall be from a nationalized or scheduled Bank and issued 12 Months from the date of submission of tender
Reports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years
Bidders shall have adequate financial stability and status to meet financial obligation pursuant to the scope of this assignment and shall meet the following minimum criteria Minimum Average Annual Turnover MAAT of the Bidder for best 03 three years out of last preceding 05 five financial years on the date of Tendering ending on March shall not be less than the amount put to tender.
₹2,820
₹1.1 L
26 Sept 2024
26 Sept 2024
21 Oct 2024
3 Oct 2024
4 Oct 2024
Dismantling, Transportation (to and fro), Re-Conditioning/Repair, Testing, Erection and commissioning of sick Power Transformer of rating 31.5 MVA, 66/11KV, BBL make, Sl. No. 4934/20 Year of Manufacture 2006 lying at Banaswadi and failed at 66/11kVBanaswadistationon total turnkey basis
Dismantling, Transportation (to and fro), Re-Conditioning/Repair, Testing, Erection and commissioning of sick Power Transformer of rating 31.5 MVA, 66/11KV, BBL make, Sl. No. 4934/20 Year of Manufactu...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Estimate Banaswadi dtd 26.09.2024.pdf
Others - Estimate Copy • 0.21 MB
tender doc-Banaswadi 20.07.docx
Tender Document • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .