| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC L-1 |
| 2 | L2₹1.7 Cr+₹5,539.55 (0.03%)Rejected-Finance | ₹1.7 Cr+₹5,539.55 (0.03%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non Responsivea |
| Sl No | Description | Qty | Unit | N K Enterprises L2 | MUNMUN KUMAR L1 |
|---|---|---|---|---|---|
| 1.00 | Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I | 397.58 | Cum | 151 ₹60,034.13 Lowest | 151.82 ₹60,360.14 |
| 2.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) | 274.4 | Cum | 15 ₹4,116.06 Lowest | 15.51 ₹4,256.01 |
| 3.00 | Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.) | 241.02 | Cum | 55 ₹13,256.16 Lowest | 55.28 ₹13,323.64 |
| 4.00 | Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding | 96.8 | Cum | 589 ₹57,015.79 Lowest | 589.51 ₹57,065.16 |
| 5.00 | Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l | 31.59 | Cum | 5,165 ₹1,63,136.53 | 5,110.26 ₹1,61,407.56 Lowest |
| 6.00 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. | 158.68 | Cum | 4,551 ₹7,22,134.48 | 4,509.16 ₹7,15,495.47 Lowest |
| 7.00 | Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I. | 68.53 | Sqm | 578 ₹39,612.07 Lowest | 578.3 ₹39,632.63 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
P.C.C in FOUNDATION | 77.87 | Cum | 4,961 ₹3,86,327.95 Lowest | 4,961.73 ₹3,86,384.8 |
| 9.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) | 1.25 | Cum | 4,598 ₹5,747.5 Lowest | 4,598.23 ₹5,747.79 |
| 10.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) | 0.51 | Cum | 4,125 ₹2,099.63 Lowest | 4,125.41 ₹2,099.83 |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
2 Feb 2026, 11:00 amClosed
E.E. BCD Building Division No.-2, Ranchi
E.E. BCD Building Division No.-2, Ranchi
Proposed Construction of Indoor Stadium Multipurpose Hall at ITI, Hehal, Ranchi, Jharkhand
2026_BCD_109552_1
15/2025-26/EE/BCD/DIV-2,RANCHI
Open Tender
Civil Works - Buildings
Works
90 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹3.4 L
26 Mar 2026
24 Jan 2026
3 Feb 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
Earthwork in excavation Trenches in hard soil (vide classification of soil item -B) all complete as per approved design, building specification and direction of E/I
Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
Filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dresssd with earth obdiened from excavation of foundation trenches within a lead of 50 m and lift of 1.5 M all complete as per building specification and direction of E.I (Mode of measurement compacted volume.)
Providing coarse clean SAND FILLING in foundation trenches or plinth including ramming & watering in layers not exceeding
Providing designation 75 Abrick work in C.M (1:6)in foundation and plinth with approved quality of clean coarse sand of F.M2 to 2.5 including providing 10mm thick morter joints , cost of screening materials , raking of joints to 15mm depth , curing taxes and royality all complete as per building specification and direction of E/l
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) P.C.C in FOUNDATION
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing R.C.C. M-200 in band at plinth level with nominal mix of (1:1.5:3) of approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position vibrating, skirting, curing, (but excluding the cost of reinforcement, taxes and royalty all complete job as per building specification and direction of E/I.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 25 mm thick
Supplying, fitting & fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminum fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 35 mm thick solid core type decorative double leaf flush door shutter with both side Nondecorative veneered with black board core bended with hight quality phenol formal dehydes synthetic resin of standered make with aluminium fittings such as hinges tower bolts, handles cleats, sand blocks and, taxes all complete as per building specification and direction of E.I
Providing T or steel reinforcement of 8,10 mm, 12 mm, &16 mm dia barsas per approved design and drawing excluding carriage of bars to work site, cutting, bending and binding with annealed wie with cost of wire, removel of rust, placing the rods in position all complete as per building specification and direction of E.
providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
providing Tor steel reinforcement of 10mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
providing Tor steel reinforcement of 12mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
providing Tor steel reinforcement of 16mm dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing designation 75B one BRICK FLAT SOILING joint filled with local sand including cost of watering taxes royalty all complete as per
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I (Cost of Cico will be paid separately)
Providing and laying 25 mm thick kotah stone slab flooring of approved sizes, texture and colour over 19 mm thick base of lime morter (1:1:1) lime putty surkhi coarse sand laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubing and polishing to granolithic finish with approved quality carborandum stone including cost of curing taxes and royalty all complete as per building specification and direction of E.I
Providing and laying 25 mm thick kotah stone tiles in risers of step skirting and pillars of approved sizes texture and colour lead over 12 mm thick cement mortar and joined with grey cement slurry mixed with pigment to match the shade of slab including rubing and polishing to granolithic finish with approved quality -- do --
proved and laying 6mm .precast white glazed tiles in wall over 12mm .cement morter (2:3)and jointend with grey cement slurry flush pointed with white cement including rubbing ,polisingand cost of curing taxes ,and royalty all complete as per building specification and direction of
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I..
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface
Providing two coats of synthetic enamel paint of apporoved shade and make over steel surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. Rate per cum for grading-III Material
Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over bed as per relevent IRC Code, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
50mm thick factory made soiled both side Prelaminated Panel PVC Chowkhat shutter consisting of frame made out MS tube of 19 guage thickness as per your size .
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
Casement window double panels with French (False) Mullion with S.S. 304 fricction hinges as per size and wieght of sash,multi-point locking system,zinc alloy (zamak) power Coated handal Using R3 series with frame (55mm& above)x (45mm& above) & sash (55mm& above) x(65mm&above) & French (Flase) mullion (55mm& above) x(65mm&above). (Height upto 1.8m)
Providing and fixing pressed steel door frames confirmig to IS: 4351 manufactured form commercial mild steel sheet of 1.25 mm thickness including hinges jomb, lock jamb, bead and if required angle threshold of mild
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes
38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
RIDGE
GUTTER
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes
75 mm diameter
110 mm Rain water pipe
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Coupler - 110mm
Single tee with door 110x110x110 mm
Bend - 110mm
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete
75mm dia
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing wash basin with C.I. rackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, ncludingpainting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing toilet paper holder : C.P. brass
Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. Internal work -Exposed on Wall
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
40 mm nominal outer dia pipes
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc.
15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete. 150 MM dia R.C.C. pipe
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
Providing & Applying high quality acrylic modified resin based texture of Dholpur/Red sand stone Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kgs/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litres/10 sqm, complete as the direction of Engineer -in-Charge .
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti- Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I
CHIPS
BRICK
Fly Ash
Moorum
Supplying fitting and fixing the following items complet with all material s as per direction of E/I.
(b) (i) 600x450mm mirrors of 6mm thick.,
Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S. Approved make with 100mm H.C.I. 'P' trap 15liters C.I. Pull and let go flushing cistern of names or other I.S.S. Equipment make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pert of vitreous white glazed earthenwere were footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. (A) 580 mm long (a) With 10ltr low level PVC cistern
Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification and direction of E/I. (b) With 10 ltr low level PVC cistern
Supplying fitting and fixing vierous white glazed eathan ware Indian Squating size 600mmx350mm urinal plate all complete as per direction of E/I. (A) Flat back or standing corner (600mm x 350mm) size (large)
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exaust fan point / callbellpoint with 1.5sq.mm FRPVC insulated copper conductor single core cable in surface/recrssed PVC conduit,with modular type switch, modular plate, suitable size G.I. box etc.as required.
Group C
Power plug wiring in PVC conduit (2x4 sq.mm):-Power plug wiring in PVC conduit (2x4 sq.mm):- Wiring for light / power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surfface / recessed PVC conduit along with 1 Nos. 4 sq.mmFR PVC insulated copper conductor single core cable for loop earthing as requried.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Circuit /sub main wiring in PVC conduit :- Wiring for circuit / sub main wiring along with earth wire with the following size PVC insulated copper conductor ,single core cable in surface /recessed PVC conduit as requried.
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq.mm + 1x2.5 sq.mm earth wire
4x2.5 sq mm + 2x2.5 sq mm earth wire
4x10 sq mm + 2x6 sq mm earth wire.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. S/F celling rose :-
S/F Batten holder :- Supplying and fixing battrn / angle holder including connection etc as requried.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
ITC. Exhaust fan upto 450 mm sweep. Installation of exhaust fan upto 450 mm sweep in the existing opening , including making the hole to suit size of the size of the above fan , making good the damage , connection , testing , commissioning etc. as required.
Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 Way (4+24), Double Door Horizontal Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6/32 amps, Single pole
40 Amp TPN
Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as required
1200 mm ( 48") BLDC 5 Star rating 32W Ceiling Fan
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as
10/12 W LED Tube Light
20/22 W LED Tube Light
Iron Sheet Plate 12mm
12" ( 300 MM ) Metal exhaust fan.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe all complete job as per direction of E/I.
Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to125.00 M
(c) From126.0 M to150.00 M
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer in-charge
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing of standered make starter pannel Board with arrangement of all necsssury protection including all taxes , all complete job as per direction of E/I.
Add 18 % GST
Add 1% Labour Cess
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_147989.xls
BOQ • 0.34 MB
F2-15.pdf
Tender Documents • 3.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .