Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹49.2 L+₹85,611 (1.77%)Rejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹51.1 L+₹2.8 L (5.69%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹52.9 L+₹4.6 L (9.43%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹59.3 L+₹10.9 L (22.6%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹57.8 L
EMD Value
₹1.1 L
Closing Date
14 Sept 2021, 6:00 pmClosed
Col Subhro Banerjee CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO BLDG NO P-216 AT CTI AF STATION JALAHALLI
2021_MES_468525_1
85213/E8
Open Tender
Civil Works
Item Rate
180 days
GE (M) (AF) Jalahalli
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE (M) (AF) Jalahalli
₹1.1 L
Yes
12 Oct 2021
17 Aug 2021
16 Sept 2021
17 Aug 2021
14 Sept 2021
2 Sept 2021
17 Aug 2021 - 26 Aug 2021
Amount
Taking down chowkats or frames not exceeding 1.5 sqm each with shutters (without taking off shutters from the frame) of any description (Steel/wooden/) all as specified and directed.
All as per item 1 above but exceeding 1.5 sqm but not exceeding 4 sqm each all as specified and directd.
M&L for taking down shuttes of any description exc 1 Sqm and n.exc 2 Sqm, each all as specified and directed.
Taking down chowkats or frames any description .exc 1.5 Sqm nexc 4 sqm each all as specified and directed.
Taking down shuttes of any description exc 1 Sqm and n.exc 2 Sqm,& refixing in the same opening all as specified and directed.
Dismantling of MS work as in of any description all as specified and directed.
Cutting holes in brick/stone walls built in CM for inserting hold fast and making good dismantled portion in CM 1:3 or PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate ¸depth of embedded portion of hold fast exceeding half brick and n.exc one brick complete all as specified and directed.
S&F steel windows with side hung shutters including box type hinges with steel handle with strike plate, telescopic peg stay, locking bracket complete with glazing bars for glazed shutter all as specified.
All as per item No 8 above but without glazing bars .
S&F steel ventilators with centre hung shutter including two pairs of brass cup pivots catch spring and pulley wheel with glazing bars for glazed shutter all as specified and directed.
All as per item No 10 above but for gauged shutter
S&F for 4.00mm thick sheet glass and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane all as specified and directed.
S&F for 4.00mm thick figured Pin headed glass and glazing with oil putty in squares not exceeding 0.50 Sqm in each pane all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified and directed.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet one side reinforced with M.S. Square tube, another side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet all as specified and directed.
M&L Factory Made 28 to 30mm thick factory made EPS Core Solid PVC Moulded Door Shutter consisting of frame made out of M.S.Tube. The core panel shall consist of 25mm thick High Density EPS conforming to IS 4671, routed with design, sandwiched in between 2mm thick Moulded prelam PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face. the door on all the edges to be sealed with lipping of 10mm (5mm x2) thick x 25mm wide PVC sheet for three sides & 60mm wide PVC sheet for lock side. The lipping shall be bonded to the 2mm Moulded / Plain PVC sheet with solvent cement. including neccessary fitiings etc complete as specified and directed.
Material & labour for 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, puttogether with glue pinned at joints, 2nd class hard wood complete all as specified and directed.
M&L Preparing surfaces of wood and wood based materials,new or old, of any description and girth, not otherwise described and treated with Creosote Oil all as specified and directed.
M&L for Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, built in cement mortar 1:4 including facing and pointing (if necessary) to match existing work complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains;hand made sliding bolts; clamps;hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F 2nd class hard wood 30mm thick panelled shutters (any no of panels) with panels of timber flat on both sides (feather edged or veneered particle board medium density , wood particle board with commercial face veneers all as specified and directed.
S&F Butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type C-21 including necessary weldding where ever required all as specified and directed.
S&F aluminium alloy anodised, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet , cast or extruded section and fixing bolts and sliding bolts of extruded section all as specified and directed.
All as per item No 23 above but fixed in repairs all as specified and directed.
S&F for aluminium anodised, barrel tower bolt 200mm of extruded section all as specified and directed.
All as per item No 25 above but fixed in repairs all as specified and directed.
S&F for aluminium handle 150mm cast type anodised all as specified and directed.
All as per item No 27 above but fixed in repairs all as specified and directed.
Supply and fix floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor 150 mm size of cover plate all as specified and directed.
All as per item No 29 above but in repairs all as specified and directed.
S/F sheet glass ordinary quality 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and glazed with putty andnecessary oil putty complete including all as specified.
M/L Preparing of new wooden surfaces of any description not otherwise describrd , over 10 cm width or girth and applying two of Synthetic enamel Paint over a coat of pink primer all as specified and directed.
M & L for Preparing old painted wooden surface and applying one coat of Synthetic enamel Painting over 10 cm width or girth all as specified and directed.
M&L preparing old steel surfaces of anydescription and applying one coat of synthetic enamel paint all as specified and directed
Demolition of dressed Stone/Brick & precast concrete block walling masonry wall walls built in cement mortar and removing the rubbish off the premises complete all as specified and directed
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping).NOTE (steel scafoldings for the support of existing RCC floor/roof slab with ISMB - 200 beams below RCC slabs in both directions supported with adjustable tubular steel props at 90cm centre to centre and bracings horizantally for rooms of size 5.50m X 3.5m and its height is of about 3.20m for carrying out the repair works like dismantling the side walls ,Provision of new walls completely including removing carefully the scafolding on completion of work complete all as specified and directed)
M&L Walling of random rubble,brought up to course, well bonded, bedded and solidly hearted, built in Cement mortar 1:4 all as specified and directed
Ditto all as per item No 37 above but except stone all as specified and directed
M&L for Keyed pointing in Cement mortar 1:4 to random or polygonal rubble including raking out joints/pointing of cement or cement lime mortar all as specified and directed.
Taking down cement plaster on brick or stone walls/ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L for 15mm thick rendering on stone masonry in cement mortar 1:6, surface is to be finished even and smooth without using exra cement all as specified and directed
M&L for 10 mm thick rendering on concrete surfaces as in ceiling in cement mortar 1:4, surface is to be finished even and smooth without using exra cement all as specified and directed
M&L for rendering 15mm thick out of 15mm thick ,5mm thick in CM 1:4 with WPC over 10 mm thick in CM 1:6 ( external/roof plaster ) on stone masonry or other fair faces of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and directed Note : WPC shall be measured & paid seperately.
M&L for distempering walls with two coats of washable oil emulsion distemper on new surfaes over a coat of alkali resistant priming paint (white or tinted) including preparation of new surfaces all as specified and directed.
M&L preparation of newly plastered surfaces of ceilings and applying two coat of white wash all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coat of cement based Paint over a coat of primer all as specified and directed
M&L for Complete removal of existing treated surface finishes and applying one coat of priming plastered and other surfaces with alkali resistant priming paint including filling up of all nail holes, and applying two coat of OBD all as specified and directed
M&L preparation of old ceiling surfaces and applying two coats of White wash all as specified and directed.
M&L for complete removal of existing treatment on wall surfaces,including preparation of old surfaces and applying two coat of cement based Paint over one coat of primer all as specified and directed
Demolition of cement concrete (un reinforced)of any description and in any position not other wise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete in roofs, floors, beams, staircases, landings, chajjas, and similar suspended work , water tank etc all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc including Brushing neat cement slurry with 3.0kg of cement per sq. Metre complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 using 12.50mm graded stone aggregate as in sub base flooring complete all as specified and directed.
M&L for Machine cut mirror polished kota stone slab flooring 20-25mm thick over 20 mm thick cement screed with CM 1:4 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as per item No 55 above but as in skirting, dado, pillar etc over and including 10 mm thick rendering in cement mortar 1:3, surface to be finished even and fair to receive kota stone complete all as specified and as directed.
Rounding to edges of stone slab one edge such as steps,cooking platform etc all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate laid in bays as in plinth protection finished even and smooth w/o using extra cement complete all as specified and directed.
M/L Forming Contraction (Dummy)joints 30mm deep x 10mm wide,filled with sealing compound Grade A complete all as specified and directed.
M & L for Joint free non skid coloured ceramic tiles 7 to 8 mm thick matt finish(square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including 15mm thick screed bed with CM 1:4 complete all as directed and specified.
M & L for Glazed coloued Ceramic tiles of size 350 X 250 X 7mm or 450 X 350 X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match as in skirting/dado including 10mm thick rendering with CM 1: 3 all as specified and directed
M & L for Joint free Non skid coloured Ceramic tiles 7 to 8 mm thick and area of each tiles exceeding 0.18 Sqm and not exceeding 0.38 Sqm as in flooring /skriting including 15 mm thick screed bedding with CM 1:4
M&L 300x300x20mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry with mixture of gray cement and pigment in equal qty to match the color of tiles incl screed bed of 20mm thick in CM (1:6) complete all as specified and directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports,overhangs,etc. also plays between floors and beams, etc complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L TMT bars 10mm dia and over cut to length, bent to shape required, including spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded aggregate as in fins, fascia, parapets all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded aggregate as in Chajjas all as specified and directed.
M&L for use and waste of form work to fins, louvers, fascia with rough finished flat concrete surfaces all as specified and directed.
M&L for use and waste of form work to chajjas and smimilar items including edges with rough finished flat concrete surfaces all as specified and directed.
M & L for Pre-cast cement concrete block masonry type C1, 1:3:6 (using 20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4,complete all as specified and directed.
M&L for Providing precast cement concrete solid building blocks or slabs type C1,1:3:6(using 20mm graded aggregate) set in CM 1:4,10cm thick (with plain or interlocking joints as directed)setting in mortar,complete, in walls all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 on ceiling,chajja,roof projection etc including finished even and smooth without using extra cement all as specified and directed.
Dismantling of PVC / any type of drain pipes 100mm dia, jointed in cement mortar and taking out of trenches, if required all as specified and directed.
Dismantling of PVC/ any type of drain pipes 75mm dia, jointed in cement mortar and taking out of trenches, if required all as specified and directed.
S&F PVC(SWR) Pipe 110mm dia single soketed, in any length with rubber ring joints, laid in trenches or in floors/ wall all as specified and directed
S&F PVC(SWR) Pipe 75mm dia single soketed, in any length with rubber ring joints, laid in trenches or in floors/wall all as specified and directed.
S&F PVC floor trap 110mm dia, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
S & F PVC (SWR) bends 110 mm dia in any radius with access door all as specified and directed.
S & F PVC (SWR) bends 75 mm dia in any radius with access door all as specified and directed.
S & F 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door inlcuding jointing with rubber washer and clamps etc all as specified and directed.
S & F 75mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door inlcuding jointing with rubber washer and solvent clamps etc all as specified and directed.
S & F 110mm dia PVC (SWR) branch piece double (double 'Y') equal or unequal with access door inlcuding jointing with rubber washer and solvent clamps etc all as specified and directed.
S & F 75mm dia PVC (SWR) branch piece double (double 'Y') equal or unequal with access door inlcuding jointing with rubber washer and solvent clamps etc all as specified and directed.
S & F 110mm dia PVC (SWR) junction single (single T') equal or unequal with access door inlcuding jointing with rubber washer and solvent clamps etc all as specified and directed.
S & F 75mm dia PVC (SWR) junction single (single T') equal or unequal with access door inlcuding jointing with rubber washer and solvent clamps etc all as specified and directed.
S&F PVC SWR vent cowl 110mm dia all as specified and directed.
S&F PVC SWR vent cowl 75mm dia all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 100 mm dia complete all as specified and directed.
Taking up or down 15mm steel tubing and connections all as specified and directed.
Taking up or down 20mm steel tubing and connections all as specified and directed.
Taking up or down 25mm & 32 mm steel tubing and connections all as specified and directed.
Supplying and laying of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
Supplying and laying of 32mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S & F for Female Brass Threaded Adaptor for 16mm dia pipe (FTA/ FBTA) complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in stone concrete block or slab walls complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white premium quality (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S/F plastic seat cover for pedastal water closets, solid, with flat bottom and cover and MS chormium plated/ PVC hinging type device complete all as specified and directed.
Supply and fixing in repairs 10 litre capacity PVC syphonic action type for low level flushing cistern including all fittings and including flushing pipe fixed in repair complete all as specified and directed.
S&F in repairs vitreous china white wash hand basin flat back size 550x400mm 'including CI/MS brackets including cutting for and pinning in brackets but excluding waste pipe complete all as specified and directed.
S & F for 32mm Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 40 gms) suitable for wash hand basins complete all as specified and directed.
S & F for Vitreous China urinals, half stall(back wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S & F for 32mm Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 40 gms) suitable for urinals all as specified and directed.
S & F for Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) all as specified and directed.
S & F in repair Pillar taps fancy type of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-120gms) complete all as specified and directed.
S&F in repair two way Bib taps of any color of PTMT two way with double control knobs 15 mm with fancy type with capstan head handle fixed to iron pipe or for union complete all as specified and directed.
S & F in repairs 15 mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed.
S & F in repairs Angle cock/ stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified complete all as specified and directed.
Supply and Fixing in repairs PVC connection 15mm size with PTMT nut of length 600mm etc complete all as specified and as directed .
S & F Towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats,(Minimum weight 90 gms) as specified and as directed.
S & F in repair viterous china squatting pan 'Orissa pattern ' size 580 x 440mm white with integral foot rests incl connecting to 'P' or 'S' trap and to flush pipe antisyphonage pipe etc compete including provn of lime concerte bedding and making good to floor complete all as specified and directed.
S&F for PTMT health faucet with 1.00m long PVC flexible pipe and wall hook complete all as specified and directed.
S&F for 600mmx450mm bevelled edge mirror of elected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
S&F UPVC spout pipe 40mm dia 60cm long all as specified and directed.
S & F Hand rails, half round or other stock section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F for MS work as in framed work such as in railings with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, railings and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M/L for Preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of Synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Taking down aluminium point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
M & L for surface point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor (FRLS) with 1.5 sq mm nominal cross-sectional area, single core, cable 1100 Volts grade ISI-694 marked with valid CM/L No. drawn in medium grade new PVC conduit of dia not less than 20MM and conduit accessories in wall/floor (except on RCC celling and on roof trusses where conduit shall be on surface ) ISI marked conduit and conduit accessories with mild steel/pressed steel sunkun box (with earth dolly ) sully painted with two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3mm thick plastic laminated sheet cover for fixing of switches, sockets including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light point controlled by one piano type 5 amp switch complete all as specifed and directed.
All as per item No 122 above but for one fan point controlled by one piano type 5 amp switch and one fan regulator complete all as specifed and directed.
All as per item No 122 above but for one 3 pin socket outlet, 5 amps on independent board complete all as specifed and directed.
All as per item No 122 above but for one socket outlet 3 pin, 5 amps on the same board controlled by separate switch all as specifed and directed.
All as per item No 122 above but for one light point controlled by two way switchs all as specifed and directed.
All as per item No 122 above but for but with 2.5sqmm un sheathed multistranded cable for one socket outlet 15 Amps indipendent including continuous copper earth wire, PVC insulated of 2.5 sqmm size all as directed
S&F switch piano flush type single pole one way 5/6 Amps, 240 volts complete all as specified and directed.
S&F switch piano flush type single pole two way 5/6 Amps, 240 volts complete all as specified and directed.
S&F socket outlet 2 in1, 5 pin, 5/6 Amps flush type, 240 Volts ISI Marked complete all as specified.
S&F switch piano flush type 15/16 Amps, 240 volts, one way complete all as specified and directed.
S&F socket outlet 2 in1, 5 pin, 6/16 Amps flush type, 240 Volts ISI Marked complete all as specified and directed.
S&F the Ceiling rose, surface bakelite, three terrminal complete all as specified and directed.
S & F step type electronic fan regulator, flush type, 240 Volts and electrical connections complete all as specified and directed.
Taking down unserviceble DBs, with MCBs and Main switches including making good to the disturbed surface to match with the existing complete all as specified and directed.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix in repair MCB SPN 40 Amps, 10KA, c series, 240 volts, 50 Hz AC supply complete all as specified & directed.
Supply and fix in repair MCB SP 6 to 32 Amps, 10KA, c series, 240 volts, 50 Hz AC supply complete all as specified & directed.
Supply and fix in repair MCB SP 63 Amps, 10KA, c series, 240 volts, 50 Hz AC supply complete all as specified & directed.
Supply and fix for VTPN distribution board, 50 Hz, 4 way with 200 Amps rated bus bar, vertical double door type, having IP:43 protection, suitable for 160 Amps 4 pole MCCB as incommer and MCBs SP as out going complet, fixed on wall and connecting with all electric connections/circuit including making good to disturbed surface to match with existing surface complete all as directed by Engineer in charge.
S&F testing and commissioning of MCCB 100 Amp 415 Volts, 16 KA, 4 pole with thermal magnetic release, fixed type complete all as directed.
Taking down existing sub main wiring with aluminum conductor cable of 2 runs of 10 sqmm with GI earth wire on and including wooden batten/ conduit and removing materials from the site and making good distrubed surface of walls and and roofs complete all as specified and as directed by Engr-in-Charge
Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 10 sq mm drawn through not less than 25mm non-metallic PVC rigid conduit, medium grade with one run of 10 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/ recessed as required including colour coding as per IS complete all as specified and directed.
Note :- 2 runs of 10 sqmm, 1 run of 10 sqmm as earth cotinuity conductor and 1 run of PVC conduit shall be measured as one unit length.
S&F as in repair LED building street light along with fixture 18 W IP-65 complete all as specified and directed.
Supply and fix LED down lighter surface mounted slim square 12 watt ultra sleek general purpose with low height CRCA house and soft diffuser lighting height 32mm and colour temperature 6000K complete all as specified and directed.
Supply and fix LED luminaire 600mm X 600mm, 35/36 watt, 220Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver 3 core flexible copper conductor cables of suitable size complete all as specified and directed.
Supply and fix LED luminaire 1195 X 295mm, 30/31 watt, 220Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver 3 core flexible copper conductor cables of suitable size complete all as specified and directed.
Taking down Ceiling fan from any height, opening and dismantling blades from fan, painting of Ceiling fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust including writing MES No with black paint etc , refixing and connecting up including provision of cable from celling rose/ connector to fan including keeping in safe custody for reuse at site and making good the disturbed surfaces complete all as specified and as directed.
M & L for cutting hole in circular shape in stone masonary wall for fixing of exhaust fan of size 300mm and making good the disturbed surfaces complete all as specified and as directed.
Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC 1:2:4 type B-1, pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion.
Taking down exhaust/ wall mounted fan from any height, opening and dismantling blades from fan, painting of exhaust fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust including writing MES No with black paint etc, refixing and connecting up including provision of cable from celling rose/ connector to fan including keeping in safe custody for reuse at site and making good the disturbed surfaces complete all as specified and as directed.
Taking down earth continuity conductor or earth lead with all connected nut, bolt, screw etc and old air termination any type/ any size complete all as specified and as directed.
M & L for lightening arrester earth continuity conductor or main earthing lead aluminium strip 25 X 3.15mm with saddles and fixing screws etc fixed to roof conductors and down conductors connection with test terminal box and other situaton including jointing by tinned copper/ brass nuts, bolts, screws in addition to brazing complete all as specified and as directed.
S & F in repair the single pointed air termination copper rod 12mm dia and 300mm long fixed to PCC Block or on insulator base complete all as specified and as directed
S & F in repair the test point terminal block made up of bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws, etc complete all as specified and as directed.
M & L for renewal of earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to copper earth strip of size 25x3.15 mm by means of copper bolts , nuts , washers with GI protection pipe 40mm dia medium grade up to 7.5m long , galvanized iron pipe medium grade 20 mm bore for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT HCR/ CRS steel bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I .
G K CONSTRUCTIONS
UNITED ENGINEERS CORPORATION
S CHANDRASHEKAR (SREE BUILDERS)
D NAGI REDDY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .