Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹41.7 L+₹2.1 L (5.39%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹41.9 L+₹2.3 L (5.74%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹43.1 L+₹3.5 L (8.84%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹44.3 L+₹4.7 L (12.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
17 Sept 2022, 6:00 pmClosed
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Provision of toilet for visitors at Stn HQ MES Staff at Kk Ranges near Bldg No P-56 and P-57 at Auto Regt and Special Repairs to Bldg Nos P-18 (Atta Store) of 58 Coy ACS (Sup) and P-51 at ASW in the area of AGE B/R II under GE (N) Ahmednagar
2022_MES_543594_2
8664 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a(i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹92,000
Yes
4 Oct 2022
30 Aug 2022
19 Sept 2022
30 Aug 2022
17 Sept 2022
5 Sept 2022
Amount
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes cable, etc. n exc 10sq m on plan and getting out in Soft / loose soil etc complete all as specified and directed by Engineer-in-Charge
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and getting out in soft / diintegrated rock etc complete all as specified and directed by Engineer-in-Charge
Excavating over areas, n exc 1.5m deep and getting out in Soft/diintegrated rock etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D2 (40mm graded stone aggregate) as in foundation, filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L for hardcore or gauge of broken stone or boulders n.exc 63mm, deposited spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for pre-cast cemnet concrete (1:3:6) type C1 (20mm graded stone aggregate) block masonary with solid block exc 10cm in width and setting in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
S&F steel ventilator with centre hung shutter including two pair of brass cup pivots catch spring and pully wheel etc complete all as specified and directed by Engineer-in-Charge
Supply and fix solid PVC door frame of s ize 50mm x 47mm made out of 5mm plain colur PVC sheet reiforced with MS square tube etc complete all as specified and directed by Engineer-in-Charge
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples etc complete all as specified and directed by Engineer-in-Charge
All as per Sl item 10 (here-in-before) but in repairs
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix mild steel tower bolt stove enamelled black with bright bolt 200mm long etc complete all as specified and directed by Engineer-in-Charge
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new steel/steel ornamental and iron surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer etc complete all as specified and directed by Engineer-in-Charge
M&L for moorum filling in floors or paving laid in layers n.exc. 15cm thick spread levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base of floor etc complete all as specified and directed by Engineer-in-Charge
Material and labour for non skid ceramic coloured tiles 8-10 mm thick size of tile 400x400mm, as in floor etc laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed with neat cement slurry & pointed with white cement or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
Material and labour for galzed ceramic colured tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles, laid over and including 10mm thick backing coat in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
Material and labour for vitrified ceramic tiles 600 x 600 mm x 10mm thick as in floors etc set and jointed in neat cement slurrry and pointed in white or colured cement to match the shade of tiles, laid over & including 15mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for Chequered cement concrete tiles With grey cement and pigments size of tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors including bedding layers of cement and sand mortar (1:6) (15mm thick) etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick in cement and sand mortar (1:6) on brick or concrete surface and finishing even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 Design mix using 20 mm graded stone aggregate as in roof slab Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden form work to sides of pillars, posts, struts, piers, columns and Stanchions etc complete all as specified and directed by Engineer-in-Charge.
Rough finished wooden Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
Use and waste for form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200 m thick (Horizontal or slopping) rough finished flat surfaces etc complete all as specified and directed by Engineer-in-Charge
Use and waste for form work to edges of concrete flats, treads, breaks in floors window cills, concrete railings openings in concrete wall foors and roods not exceeding 20 cm wide and sides of RCC / PCC bands in walls, horizondal or slopping and similar work etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 Designl mix using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 Design mix using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 Design mix using 20 mm graded stone aggregate as in Chajjas etc complete all as specified and directed by Engineer-in-Charge
M&L for RCC M-25 Design mix using 20 mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge
M&L for TMT bars 6 to 8mm dia and bars cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge
All as per Sl No 34 (here-in-before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture etc complete all as specified and directed by Engineer-in-Charge
Material and labour for rendering 5 mm thick on fair faces of concrete surface with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
M&L for rendering 15 mm thick on fair faces of concrete in cement and sand mortar (1:4) and finished even and smooth without using extra cement including WPC @ 3% of weight of cement content etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering, 10 mm thick on faces of brick work / concrete work or stone masonry surfaces with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
Material and labour for rendering, 12 mm thick on brick work / concrete work or stone masonry surfaces with Ready Mix Plaster (RMP) in single layer of Makes / Brands ACC's "Accoplast" / CK Birla's "Aerocen" / Magic Plast / Buildwell / Speed Dry Mix's "Eco Plaster" etc complete all as per manufacturer's instruction and directed by Engineer-in-Charge. The thickness of plaster is the minimum thickness and is exclusive of thickness of key. Dubbing if required is deemed to be included in the plaster and nothing extra shall be paid.
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new Pleatered surfaces and applying two coats of cement paint over a coat of chalk primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparing unplastered or plastered surfaces and applying two coats of oil bound distemper including chalk whitening on wall including smooth roller finish etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in and including spreading ,leveling,watering and well raamming in layers.n exc 25 cm etc complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix bib tap, 15 mm dia, water foam base, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing stop valve cast copper alloy, fancy type screwed down, high pressure screwed both ends for iron pipe or for union and fix of size 15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 15 mm dia swan neck water foam base pillar tap, cast copper alloy, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
Material and labour in repairs glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
S&F rotational molded polyethylene water storage tanks double layer(cylindrical vertical with closed top) of 1000 litres capacity, triple layered, hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting including taking down old water tank etc complete all as specified and directed by Engineer-in-Charge
S&F PVC connections 15 mm size with Stainless steel Nuts of length 600mm etc complete all as specified and directed by Engineer-in-Charge.
S&F for PVC (SWR) floor trap, plain with grating including jointing with solevent cement 75 mm bore etc complete all as specified and directed by Engineer-in-Charge.
S&F for low density polyethelene pipes 32 mm bore (LDPE) of pressure rating 6 Kg/cm² laid in trenches/fixed to wall etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC valveless, syphonic action type, flushing cistern,low level, all accesories etc complete all as specified and directed by Engineer-in-Charge.
S&L of CPVC pipes SDR 11 including fittings in trenches, 16mm outer dia fixed to walls /ceiling or laid in trenches incl all necessary fittings etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 56 (here-in-before) but 20mm outer dia.
All as per item No 56 (here-in-before) but 32mm outer dia.
Supply and fixing Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) etc complete all as specified and directed by Engineer-in-Charge.
S&F vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Grating doom 100mm dia of PTMT (Minimum weight 25gms) etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix wash hand basin vitreous China, ovel shape wall mounted of size 450 X 300 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix wash hand basin vitreous China, built in counter platform of size 550 X 400 mm including a PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as specified and directed by Engineer-in-Charge.
M&L for Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) etc complete all as specified and directed by Engineer-in-Charge.
M&L for 16mm to 18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement and sand mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing of exposed edges etc complete all as specified and directed by Engineer-in-Charge
Supply and fix looking mirror of size 600 mm X450 mm etc complete all as specified and directed by Engineer-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required etc complete all as specified and directed by Engineer-in-Charge.
M&L for APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application incluiding Priming surfaces and applying normal treatment (for moderate conditions), using glass fibre base bitumen felt, grade 2 etc complete all as specified and directed by Engineer-in-Charge.
M&L rendering 10mm in cement and sand mortar (1:3) using 100% course sand on roof mixed with and including WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.. Note :- Water proofing compound measered and paid separately
M&L for PCC 1:3:6 Type - C1 using 20 mm graded aggegate as in surface chanel, benching in manhole etc complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work complete all as specified and as directed.
M & L for Rendering 10 mm thick in cement and sand mortar (1:4) surface finished even and smooth with setting coat on fair faces of brickwork or concrete surfaces etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC pre cast manhole cover slab in 1:2:4 type -B1 using 20 mm graded stone aggrgate incl necessary form work and set in cement and sand mortar (1:6), cover slabs (for man holes etc) etc complete all as specified and directed by Engineer-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed by Engineer-in-Charge.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed by Engineer-in-Charge.
S&F for 110 bore PVC (SWR) bends any radius etc complete all as specified and directed by Engineer-in-Charge.
S&F for 75 bore PVC (SWR) bends any radius etc complete all as specified and directed by Engineer-in-Charge.
S&F for 110 mm bore PVC (SWR) branch piece, double (double Y), equal or unequal etc complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) branch piece, double (double Y), equal or unequal etc complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm PVC (SWR) vent cowl etc complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced concrete pipes, class NP2, laid and jointed in cement and sand mortar (1:3) complete with collars 150 mm bore pipes etc complete all as specified and directed by Engineer-in-Charge.
M&L for Concrete bed Cement concrete (1:3:6) type C-2 (40 mm graded stone aggregte) to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC Hume pipe septic tanks designed to carry sewage and sludge water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection etc. complete for 10 users as per Drg etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc complete all as specified and directed by Engineer-in-Charge.
Demolition of brick/ stone masonry built in cement or lime mortar etc complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in 1:6 etc complete all as specified and directed by Engineer-in-Charge.
Forming jambs, etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge.
M&L for rolled sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters and runnng rails and guides for sliding doors fixed with angle cleats or other connecting plates etc complete all as specified and directed by Engineer-in-Charge
M&L for pre painted manglore pattern galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof coverin/cladding to wall fixed with self tapping screw etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 0.50 mm thick plain, galvanised, mild steel sheeting of any colour, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified and directed by Engineer-in-Charge
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed by Engineer-in-Charge.
M&L for Hand cut kota stone slab flooring 20-25mm thick, laid over and including screed bed 15 mm thick in cement and sand mortar (1:6) set and jointed with white or coloured cement to match the shade of kota stone including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick backing coat cement in cement and sand mortar (1:4) set and jointed with white or coloured cement to match including rubbing and mirror polishing etc complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) Type B-1 (20 mm graded stone aggregate) as in hold fast blocks and rafter bed blocks etc complete all as specified and directed by Engineer-in-Charge.
S&F for steel windows with side hung double shutters incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly. 2. M&L for glazing shall be measured and paid separetly.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted Wood or wood based surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel etc complete all as specified and directed by Engineer-in-Charge.
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron etc complete all as specified and directed by Engineer-in-Charge.
M&L for Scantling Second class hard-wood in scantlings wrought and including applying two coats of linsed oil with preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab & tiles of any description in floor, approx laid, bedded & pointed in any mortar etc complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment and preparation of old plastered surfaces and Providing and applying Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, removal to store 15 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, removal to store 20 mm bore pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairsn Tubular towel rail 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed by Engineer-in-Charge.
S&F MS 10mm dia round guard bars etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed Engineer-in-Chage Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc.
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
M&L for Modular point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches / socket / regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLSH cable as earth continuity conductor to common earth & connecting to earth dolly for the following, etc complete all as specified and directed Engineer-in-Chage Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by one No piano type switch 5 Amps single pole one way
One fan point controlled by one No piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on same board controlled by one No piano type switch 5 Amps single pole one way
One 3 pin 5 Amps socket outlet on independent board controlled by one No piano type switch 5 Amps single pole one way
One bell point on independent board controlled by one No piano type switch 5 Amps single pole one way
All as per Item No 114 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket outlet on independent board
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 16 Amp, onw way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F bell Ding dong type elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge
S&F Stepped type fan regulator flush type on the existing etc complete all as specified and directed by Engineer-in-Charge
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S&F in replacement double door Sheet metal enclosures factory madeVertical concealed in wall DBs 4 way, (TPN DB's) 415 volts including 63 Amps MCCBs incomer, protection class IP-42, suitable for fixing MCBs, etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 100 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed Engineer-in-Chage
S&F in replacement double door Sheet metal enclosures factory made DBs 8 way, (SPN DB's) 240 volts protection class IP-42, suitable for fixing MCBs, etc, confirming As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 200 Amps rated copper Busbar, With Neutral bar, Earthbar and Cable lies for Cable management, Fully shrouded, Neutral bars, Prefitted masking sheet etc complete all as specified and directed Engineer-in-Chage
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,protection class IP-42, suitable for fixing of MCBs, etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet etc complete all as specified and directed Engineer-in-Chage. Make: Legrand ,Cat No:5076 10 or equivalent in Simens/ Hager/ L&T
Supply & fixing MCBs, TPN, AC, 240 volts of 63 Amps capacity 25 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Industrial type aluminium housing ultra slim square profile LED lighting fixture with extruded , environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge Make:Philips Model Name Astra line or equvivalent in makes mentioned in list of makes in Appendix `C'
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLSH stranded copper conductor cable 6 Sqmm with 6 Sqmm PVC insulated, unsheathed, FRLSH stranded copper conductor cable as earth wire drawn through in and incl PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly all as specified & directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) Note: Two run of 6 sq.mm cable i.e for one run for phase, one run for neutal with one run of 6 sq.mm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable10 Sqmm, 2 core.
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply &lay GI pipe 40 mm bore for laying of LT cable on wall/pole complete with all accessores etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
Cutting to existing CI/GI pipe line upto 80 /50/25 mm dia for taking connection up to 25 mm dia GI pipe including insertion of CI /GITee complete all as specified and directed including Exc & earth Work
Supply and lay in trenches/or on wall medium grade steel water tubing galvanised with all fittings and joints etc complete for following size :-
(a) 20 mm bore
Supply and fix Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 20 mm pipe
Supply and fix gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for for 20 mm bore.
An amount of Rs 59,319.00 shall be deducted from BOQ on account of schedule of credit
OM SAI ASSOCIATES
M/s AG PATHAN
M/s. Sagar Traders
PRAVIN NANDKUMAR WARULE
M/S. YADAV ENTERPRISES
MS. A.S. CONSTRUCTION
M/S. AMERHAMZA GULAB SHAIKH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .