| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.8 L+₹3.5 L (22.6%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹19.7 L+₹4.3 L (28.2%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
29 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Major A R Thakkar
GE (P) Dappar
Repair and Cleaning of sewage lines, Septic tanks and Soakage wells at Mil Stn Dappar under GE (P) Dappar
2022_MES_557897_2
GE (P) DPR-24/2022-23
Open Tender
Civil Works
Works
330 days
GE (P) Dappar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) Dappar
₹40,000
Yes
16 Dec 2022
9 Nov 2022
1 Dec 2022
9 Nov 2022
29 Nov 2022
10 Nov 2022
9 Nov 2022 - 10 Nov 2022
Amount
Cleaning of sewage lines incl manholes of 150mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit complete all as directed by Engr-In-Charge.
Cleaning of sewage lines incl manholes of 200mm bore by means of cleaning rods through manholes to manholes, taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and over the pit complete all as directed by Engr-In-Charge.
De-watering of septic tanks and soakage wells by with sewage pump air tight body hired by contractor and draining out the same out of cantt area complete all as directed and to the entire satisfaction of Engr-in-Charge. Note : (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate. (b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
Taking out sludge from septic tanks incl inlet and outlet chambers, removing and depositing the sludge in a pit at out of MOD Land by means of moter pump covering the sludge in the pit with earth and finally spraying unslaked lime, dry, around the septic tank and over the pit complete all as directed Note : (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate. (b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
Cleaning of blocked Bottle trap, WC-'P' trap/ 'S' trap, Nahani trap, Kitchen-Gully trap etc upto 1st manhole and making the drain pipe of any size full functional by flushing with water to entire satisfaction of Engr-in-Charge. Note : (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be included in the unit rate. (b) Any damage caused during cleaning shall be rectified to satisfaction of Engr-in-Charge by the contractor without any extra cost.
Demolition of brick work built in cement mortar complete all as specified & directed by Engr-in-charge.
Material and labour brick work in cement mortar 1:4 with sub class 'B' bricks old size straight or curved on plan exceeding 6m mean radius complete all as specified and directed by Engr-in-charge.
Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement should be cut as required to facilitate) complete all as specified and directed by Engr-in-Charge.
Material & labour Soakage wells excavation, in any type of soil, foundation in PCC 1:4:8, walls of honey combed masonry with top ring of 1:1.5:3 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in 1:1.5:3 SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8M dia and 3.0M deep as specified in TD Drg No STD 1173 (C) Sheet No 1R/2 & 2R/2
Material & labour RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC 1:1.5:3 in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, Cosntruction of S/Tank 50 user brick wall and RCC slab all as specified in TD Drg STD 1320 (C) SHEET NO 1/3 to 3/3
Material & labour RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC 1:1.5:3 in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc, Cosntruction of S/Tank 200 user brick wall d and RCC slab all as specified in TD Drg STD 1320 (C) SHEET NO 1/3 to 3/3
Taking down cement plaster any thickness from walls of manholes and septic tanks including raking out joints, hacking for key scrubbing down with water and removal of debris etc complete all as specified and directed by Engr-in-charge.
M&L for cement plastering 15mm thick (10+5) in two layers in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair complete all as specified and as directed by Engineer-in-Charge. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge. Make : Pidilite/Sika
M&L for precast cement concrete (1:2:4), nominal mix, type B-1 uising 20 mm graded stone aggregate as in cover slab of drain set in cm 1:4, complete all as specified and as directed . Note:- Reinforcement shall be measured seperately
Supply and fixing TMT bar 10 mm dia and over, cut to length, bent to shape required including cranking, hooking ends and binding with and including mild steel (annealed) wire not less than 0.9 mm dia or securing with clips etc all as specified and directed by Engr-in-charge.
Demolition and breaking up 150 to 300 mm bore drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed by Engr-in-charge.Note :- Excavation work shall be measured & paid separately.
M & L for cement concrete bed (1:3:6) type C-2 using 40mm graded stone aggregate to drain pipe of 150 mm bore including packing under haunching against the side of pipe after they are laid and tested.
M & L for cement concrete bed (1:3:6) type C-2 using 40mm graded stone aggregate to drain pipe of 300 mm bore including packing under haunching against the side of pipe after they are laid and tested.
Material and labour for 150mm internal dia RCC NP2 class pipe laid in trenches jointed with CM 1:1 and tested as specified. Note:- Excavation work shall be measured & paid separately.
Material and labour for 300mm internal dia RCC NP2 class pipe laid in trenches jointed with CM 1:1 and tested as specified. Note:- Excavation work shall be measured & paid separately.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m deep and getting out in soft/loose soil all as specified and directed by Engr-in-charge.
M & L for PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregate as in foundation complete all as specified and directed.
Taking down soil waste and vent pipe of 100 MM DIA any description and any position joint/Lead joint and removing from site (including cleaning servicable pipe and stack seperately for reuse ) complete all as specified and directed by Engr-in-Charge.
S&F Cast iron soil, waste and vent pipe,100mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections, fixed as in repair complete all as specified and directed.
S&F 100 mm cast iron soil waste and vent pipe in any length with or without ears laid in floor incl dismantling of old pipe and excavation of trenches, refilling and leveling of surface complete all as specified and directed.
Cast iron bends radius for 100 mm bore pipe, as in repairs, complete all as specified and directed.
S&F cast iron junction combination 'T' equal or unequal for 100mm bore with access door as in repair complete all as specified.
S&F CI Nahani Trap including jointing to waste pipe in neat cement 100 mm dia fixed in cement concrete (1:2:4) type B1.complete all as specified and directed.
M&L for cast iron cowls of 100 mm dia complete all as specified and directed.
Material and labour PCC 1:3:6 type C-1 (using 20mm graded mechanically crushed stone aggregates) as in benching and chamfering & making channels etc, complete all as specified and directed by Engr-in-charge.
Removal of surplus soil to a distance exceeding 250mm but not exceeding 500m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engr-in-charge.
S & F in repair vitreous China WC seat size 580x440mm (Indian type) Orissa pattern) complete with CI ‘P’ trap, lime concrete in sunken floors making connection with flush pipe using new GI flush bend (Floor portion) and making good to floors, matching to existing surfaces, to the entire satisfaction of Engineer-in-Charge.
S & F in repair vitreous China wash down water closet Pan (pedastal pattern) white including all joints and making good to floor, matching to existing surfaces, to the entire satisfaction of Engineer-in-Charge.
M & L non-Skid whilte ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge
S & F plastic water closet seat cover, white closed pattern fwith flat bottom and mild steel chromium plated hinges complete all as specified and directed by Engineer-in-Charge.
Note : The work will be executed/carried out in Domestic and technical area of the Mil Stn Dappar
M/S Mahal Enterprises
M/S Trilok chand sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .