| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC S NO 7 3 FLAT NO 4 HILL VIEW RESIDENCY LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.9 L+₹1.4 L (4.01%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹44.0 L+₹8.5 L (23.9%)Rejected-Finance 207 GARIWAN TOLA ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211003 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹45.8 L+₹10.3 L (29.0%)Rejected-Finance AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹45.8 L+₹10.3 L (29.1%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Being L5 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
24 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Spl repairs to certain Bldg inside RSSD area at OD Fort Allahabad.
2021_MES_492133_1
8529/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹78,000
Yes
2 Feb 2022
2 Dec 2021
27 Dec 2021
2 Dec 2021
24 Dec 2021
17 Dec 2021
2 Dec 2021 - 9 Dec 2021
60 days
Amount
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Brickwork with flyash bricks (crushing strength not less than 75 Kg per sqm), old size straight or curved on plan exceeding 6 metre mean radius, built in CM 1:6, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Plain Cement concrete 1:2:4 type B-2 (using 40 mm crushed stone aggregate), 75mm thick, as in ramp, complete all as specified and directed.
Plain cement concrete 1:2:4, 40 mm thick, type B-1 (using 20mm graded crushed stone aggregate) laid in alternate panels including use and waste of form work finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish off the premises, complete all as specified and directed.
Rendering 10mm thick, on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished surface even and fair without using extra cement, complete all as specified and directed.
Dismantling of AC corrugated or semi corrugated sheet including AC ridges as in roof covering or wall etc, complete all as specified and directed..
Dismantling timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and directed..
Plain Cement concrete 1:2:4, type B-1 (20 mm crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges including necessary formwork, complete all as specified and directed. .
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil, complete all as specified and directed. .
PCC 1:2:4 type D-2 using 40 mm graded crushed stone aggregate as in foundation filling or mass concrete including subbase of floors, complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed.
Plate girder or single stanchions (ISMB-100), built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections conforming to Fe 410 -W (GdeE-250) quality A including welding, cutting, etc. complete all as specified and directed.
Second class hardwood in scantling clean sawn timber framed, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, valley gutter, ridge hips etc, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 MPa as in roof covering / cladding to wall, valley gutter, ridge hips etc, fixed with self tapping screws, complete all as specified and directed.
Fibre glass reinforced translucent corrugated sheeting, 2mm thick, with two corrugations side lap fixed with coach screw and washer in roof, wall etc, complete all as specified and directed.
Demolition of Concrete work (un-reinforced) in ground floors and pavings including floor tiles not exeeding 15 cm thickness (below or above ground level) and removal of debris from the site, complete all as specified and directed.
Plain cement concrete 1:2:4, 50 mm thick, type B-1 (using 20mm graded crushed stone aggregate) as in floor, (laid in alternate panels) including use and waste of form work finished even and fair, complete all as specified and directed.
Wearproof topping, 20mm thick (incorporating an approved metallic floor hardner in the ratio of 1 part of hardner : 4 parts of cement in dry state), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner), complete all as specified and directed. NOTE:- Metallic floor hardner shall be measured as 'Supply only' under resepctive items of this Schedule.
Supply only approved metallic floor hardner, complete all as specified and directed.
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded joint, including two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces, fixed in repair, complete all as specified & directed.
Steel window factory made with side hung shutter including box type hinges with steel handle, steel peg stay, complete without glazing bars, dovetailed or welded joint, including two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces, fixed in repair, complete all as specified & directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden or metal frames fixed with putty or beads etc, complete as specified & directed.
Sheet glass, 3 mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sq. m in each pane, complete all as specified and directed.
Repair of rolling shutter (gear type) exceeding 10.0 Sqm but not exceeding 25.0 Sqm and greasing/oiling complete with locking arrangement for smooth functioning of the shutter including taking down and refixing of the rolling shutter complete all as specified and directed NOTE: (i) The unit quoted rate shall be inclusive with replacement of any spare parts required for smooth functioning. (ii) If gear box to be replaced, shall be measured and paid separately under supply only item. Fixing of gear box to be included in unit quoted rates.
Supply only gear box with complete accessories for rolling shutters while servicing the rolling shutter as mentioned in above item complete all as specified and directed.
Steel rolling shutters, 1.25 mm thick, without ball bearing, as specified including top cover, anchoring rod, hasp and staple; erected in position as indicated, complete push pull or manual type, fixed in repair, complete all as specified & directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
Complete removal of existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including preparation of surfaces by rubbing with appropriate size of sand or emery paper and applying two coats of cement base paint on walls surface complete all as specified & directed.
Preparation of old wooden surfaces exc 10 cm width or girth with sand or emery paper & applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of new wooden surfaces exc 10 cm width or girth with sand or emery paper & applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparation of new steel and iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
Taking down point wiring of any type and any description / caping or concealed [light point, fan point or socket point] including removal of battens, pipes, plug sockets, switches, shades, ceiling roses, light fittings etc complete and making good disturbed surface to match the exisitng, complete all as specified and directed.
Taking down main switches, DBs, cut-outs of any type alongwith existing boards and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Taking down carefully submain wiring of any type and size including earth wire on wooden batten / surface conduits / casing and caping etc., and removing the same from site and making good disturbed surfaces of walls to match with the existing, complete all as specified and directed.
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 1.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 1.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface, complete all as specified and directed for the following:-
One light / fan / bell / exhaust fan point, controlled by one one-way 5Amp switch
One 3 pin, 5 Amp socket outlet point on an independent board.
One 3 pin, 5 Amp socket outlet on the same board with other switches
Point wiring complete with PVC insulated unsheatehd, 1100 volts grade cable 2.5 sq.mm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including not less than 20mm dia rigid PVC conduit 'medium grade' ISI marked including all conduit accessories for concealed wiring for one 15 Amp socket outlet on independent board, including provision of concealed pressed steel terminal box of required size not less than 1.0 mm thick factory made duly painted inside and outside with two coats of black bituminous paint over and including a coat of red oxide primer, with 2.8 mm thick top cover of plastic lmainated sheet of required colour for mounting switch, sockets, fan regulator etc, including 2.5 sq.mm FRLS type PVC insulated unsheathed cable multi stranded copper conductor as continuous earth wire and connected to earth dolly as required at site and including chases cutting and making good the disturbed surface and applying finishes to match the existing surface.
Sub main wiring complete with 2 runs of 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawing into and including PVC casing & caping, medium grade not less than 25 mm wide with all accessories connecting terminal ends to DB's including providing 1 run of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC rigid conduit and with accessories shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Switch piano, flush type single pole, one way 5/6 Amp 230 volts all as specified and directed.
Socket outlet, 2 in 1, 2/3 pin, 5/6 Amps 230 Volts, flush type, complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp 240 volts all as specified and directed.
Socket outlet, 2 in 1, 2/3 pin, 5 to 15 Amps 230 Volts, flush type, multipurpose, complete all as specified and directed.
Ceiling rose, single phase, PVC / polycarbonate, insulated body, three terminals, surface bakelite sheet 63.5mm dia, complete all as specified and directed.
Ceiling fan regulator flush type, electronic, rotary stepped type, 120 W, AC 230 V, suitable for any type of ceiling fan, complete all as specified and directed.
LED wall mounted tube light fitting, 1x20W, LED 6000K, decorative ultra slim, round profile, LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete with all accessories, pre-wired and making connection with and including provision of three core flexible copper cable of size 23/0.0076 from ceiling rose to connector of required length including LED lamp, complete all as specified and directed. Make: Havells E Lite Pride Plus Cat Part No LHEXBLP7PN1W020 or techno-commercially equivalent model in Bajaj/ Philips/ Crompton as approved by GE.
Sheet metal enclosure for MCB DBs TPN, 4 way, double door, acrylic type, 415 V with 200 Amps rated bus bar, complete with incoming/ outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Sheet metal enclosure for MCB DBs SPN, 8 way, double door, acrylic type, 415 V with 200 Amps rated bus bar, complete with incoming/ outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Sheet metal enclosure for MCB DBs SPN, 4 way, double door, acrylic type, 415 V with 200 Amps rated bus bar, complete with incoming/ outgoing connection through proper size of lugs and cable glands including taking down existing MCB DBs, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
MCB TPN, 63 Amp, 415 Volt, conforming to 'C' curve, 10kA breaking capacity, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
MCB SPN, 40 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, complete all as specified and directed. Make: Legrand/ Schneider/ ABB/ L&T/ Indo Asian
Isolator / MCB SP 6/10/16/32 Amp, 240 Volt, conforming to 'B' curve, 10kA breaking capacity, fixed in repair, complete all as specified and directed.
Taking down / out existing ceiling fan for servicing, greasing, replacement of bearing, safety pin, canopy, fan condensor, clamp, rubber reel, nut / bolts as required at site and cleaning and preparing surface, filling cavities with filler including one coat painting with synthetic enamel paint including down rod of approved white colour including writing of MES No. one fan head and refixing in its original position and making all electric connection, complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe light grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
M/S ATUL CONSTRUCTION
Ram Babu Bros
M/S A P CONSTRUCTION
Mohit Enterprises
K L KALSI
vs construction
Channa Brothers and Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .