Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.5 LAccepted-AOC | ₹74.5 L | L1 | Accepted-AOC First Lowest and responsive |
| 2 | L2₹74.5 LRejected-AOC NALHATI BIRBHUM | NALHATI | BIRBHUM | WEST BENGAL | ₹74.5 L | L2 | Rejected-AOC Second Lowest |
| 3 | L3₹74.5 LRejected-Finance | ₹74.5 L | L3 | Rejected-Finance Third Lowest |
Tender Value
₹74.6 L
EMD Value
₹1.5 L
Closing Date
3 Mar 2026, 6:00 pmClosed
Executive Engineer (A-M) Suri (A-M) Division
Barabaagan, Suri, Birbhum, 731103
Construction of Laskarpur-I New Major RLI scheme at Mouza-Laskarpur, Block-Nalhati-I in the District of Birbhum under the Executive Engineer (AM) Suri (AM) Division under Core-Sector Program
2026_WRDD_998848_1
WRDD/EEAM/SURI/ENIT-24/2025-26
Open Tender
Project Work
120 days
Nalhati-I
Please refer Tender documents.
7 documents required · 7 mandatory
₹1.5 L
11 Mar 2026
3 Feb 2026
5 Mar 2026
3 Feb 2026
3 Mar 2026
3 Feb 2026
Supply and transport of materials to proposed site inclusive of all demand
315 mm dia P.V.C pipe class-I ( with a loose matching coupler) marking IS No. 4985/2000 with latest amendments with free solvent cement.
200 mm. dia P.V.C. pipe Class- I ( with a loose matching coupler ) marking IS No. 4985/2000 with latest amendments with free solvent cement.
140mm. dia P.V.C. pipe Class-I ( with a loose matching coupler) marking IS No. 4985/2000 with latest amendments with free solvent cement.
140mm. dia P.V.C. pipe Class-II ( with a loose matching coupler) marking IS No. 4985/ 2000 with latest amendments with free solvent cement.
200X200X200 mm dia P.V.C. Equal Tee with free solvent cement.( IS.No. 10124 (Part 5) : 2009 with latest amendment)
140X140X140 mm dia P.V.C. Equal Tee with free solvent cement.( IS.No. 10124 (Part 5) : 2009 with latest amendment)
315 mm. dia P.V.C (IS.No. 10124 (Part 6) : 2009 with latest amendment) F.T.P. Class-II with free solvent cement
200 mm.. dia P.V.C (IS.No. 10124 (Part 6) : 2009 with latest amendment) F.T.P. Class-II with free solvent cement
160 mm. dia P.V.C (IS.No. 10124 (Part 6) : 2009 with latest amendment) F.T.P. Class-II with free solvent cement.
200 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement.( IS.No. 10124 (Part 3) : 2009 with latest amendment)
160 X 140 mm dia.P.V.C. Reducer (Class-II) with free solvent cement.( IS.No. 10124 (Part 3) : 2009 with latest amendment)
200 mm. dia 600 ( IS.No. 10124 (Part 9) : 2009 with latest amendment) bend
140 mm. dia 900 ( IS.No. 10124 (Part 8) : 2009 with latest amendment) bend
140 mm. dia 600( IS.No. 10124 (Part 9) : 2009 with latest amendment)
200 mm. dia P.V.C (IS.No. 10124 (Part 4) : 2009 with latest amendment) end cap Class-III with free solvent cement.
140 mm. dia P.V.C (IS.No. 10124 (Part 4) : 2009 with latest amendment) end cap Class-III with free solvent cement.
315 mm. dia P.V.C (IS.No. 10124 (Part 2) : 2009 with latest amendment) Extra Coupler Class-II with free solvent cement
200 mm. dia P.V.C (IS.No. 10124 (Part 2) : 2009 with latest amendment) Extra Coupler Class-II with free solvent cement
140 mm. dia P.V.C (IS.No. 10124 (Part 2) : 2009 with latest amendment) Extra Coupler Class-II with free solvent cement
Extra Solvent cement I.S. 14182-2009 with latest amendments
G.I set for distribution chamber and Inlet & outlet Pipe Fittings all materials ISI marked (as per drawing and technical specification)
150 mm. dia ISI marked Sluice Valves Pressure designation P.N. 1.6 with hand wheel for Water Works Purpose,C.I. flanged type IS:14846/2000 with amendment No.1 & 2. Components/Parts of Sluice Valves shall be manufactured from basic materials given in table 1 of IS:14846/2000 with amendment 1 & 2. The valves shall be tested for (closed end test) against Hydrostatic test requirement. IS marked IS:14846.
C.I. Foot valve ( 150 mm. dia) heavy duty flange type W/t. 28 Kg + 5% IS: 4038/1986 with latest amendment ISI marked.
150 mm dia CI Alfa-Alfa Valve (C Type) With hand Wheel 01 no. for 04 Nos Valve( as per Approved Existing Drawing.)
G.I. 150 mm dia 90º M.S bend (With priming arrangement) ISI marked- IS 1239, Galvanisation IS 4736
G.I. 150 mm dia 90º M.S bend both end flanged ISI marked-IS 1239,Galv-IS 4736
150 mm dia.(4.8mm) Galvenized MS Flanged Pipe, IS marked- IS:1239,Galv-IS 4736.
150 mm dia 2mm thickness 45mm width Heavy Duty Hose Clamp fitted with nuts & bolts
150mm dia. C.I. Tail Piece one End Flanged other End Grooved
150mm dia. C.I. Tail Piece both End Grooved
Foundation Bolt, For Distrubution Chamber Quadruped (1.1 Kg each) manufactured from 20 mm nominal dia MS rod as per IS 2062/1992.Total length of the bolt is 375± 10mm having welded head 80±10 mm in length and 20 mm nominal dia with Nut & 2 Nos. Washer.
M.S Foundation Bolt for Pump Motor sets manufactured from 20 mm nominal diameter M.S Rod as per IS 2026/1992. Total length of bolts is 275±10 mm in length & 20 mm in nomonal diameter with Nuts & 2 nos washer,the average weight of such bolt 1.5 kg per bolt with tolerance in weight of each bolt @ ±10%
Nuts & Bolts
GI Reducer 300 x 150 mm NB , with ISI marked Flange
GI Non return valve 150 mm NB ,
GI Blank Flange 300 mm dia. NB, 18 mm thickness, Conforming to ISI
Foot valve Lather washer(150mm.dia) (Techno/ English Leather)
Compresed Asbestos fibre jointing for Quadruped & Tripod set (for raised surface of Flange as per IS-6392) 500 mm dia
150 mm dia PVC flexiable suction hose pipe ISI marked,IS15265.
Rubber Insertion (for raised surface of Flange as per IS-6392) 5mm thick with proper reinforcement 2 ply conforming to I.S. 638/79 with ISI mark (Without Holes)
300 mm dia( Table-11)
300 mm dia( Table-5)
200mm.dia( Table-11)
200mm.dia( Table-5)
150mm.dia( Table -17)
150mm.dia( Table -5)
80 mm.dia(Table-17)
20 H.P Induction Motor Coupled with Centrifugal water Pump, 150 mm dia Inlet and 150 mm dia outlet and having a discharge capacity of 200 cubic meter per hour discharge at 18 meter total head. Pump should be directly coupled with Motor and mounted on a common fabricated M.S Base frame.
Sheet metal enclosed rewireable type Fuse, Main Switch, 415 V 3 v Phase , 50 cycles A.C. supply conforming to IS 60947 (Part-3) /1993 for 63 Amp TPN.
Sheet metal enclosed rewireable type Fuse, Main Switch, 415 V 3 v Phase , 50 cycles A.C. supply conforming to IS 60947 (Part-3) /1993 for200 Amp TPN
Heavy Duty Semi-Automatic Air Break Star-Delta Starter for 20HP/15 Kilo-Watt Electro-Motor Surface Water Pump starting for use with 415Volt(+6% to 15%),3phase, 50Hz (+-3%)AC Supply conforming to IEC:60947(Part-4)Sec-1 & IS:13947) (Part-4)/1999,tested for type -2 Co-Ordination and AC 23A utilization category. Make:L&T,BCH,C&S,Havelles,Schneider,ABB ltd & Seimens or other reputed make.
500 volt, 200Amp Busbar Chamber
Supply of 3Core 10 sq mmsize, 250 Volt Copper Conductor as per IS no.1554(part-I) having ISI Mark
Supply of 1.1 K.V. grade 3.5 Core P.V.C. insulated 50 Sq.mm size alluminium conductor armoured cable as per IS no. 1554(Part-I) having ISI mark.
Laying of Water Transmission Arrangement for Major RLI Scheme
Earthwork in excavation of field trenches as per design section and alignment for laying of pipe lines(PVC,RCC,ACP etc) upto a depth of 1500 mm all sorts of soil including removing,spreading or stacking extra earth as directed.The item includes necessary trimming of sides trenches,levelling,dressing and ramming the bottom as required complete.
For Pipe Trenches etc.
Earthwork in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite and sand stone), including removing, spreading or stacking the spoils, within a lead of 75 m as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1500 mm. (considering 50 mm clearence) For spout Chamber and For foundation Blocks of Quadrupped.
Earth work in filling in treches after laying pipelines (P.V.C, R.C.C, A.C.P etc) with good earth obtained from excavation of field trenches in layers not exceeding 225 mm, including watering and ramming etc layer by layer complete (Payment to be made on the basis of mesurement of finished quantity of work)
Laying of UPVC pipes of different diameters within field trenches in curve/ straight line including using UPVC fittings, Viz. Horizontal and Vertical Bends, riser pipes, Tee Reducer etc.and making leak proof joints with couplers after roghening the surface with wire brush and emery paper and applying solvent cement (The rate is inclusive of transport of pipes, fittigs and solvent cement to be supplied by deptt.) all complete asper direction of Engineer-In- charge.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
For foundation Blocks of Quadrupped
For spout Chamber
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)
For foundation Blocks of Quadrupped
For spout Chamber
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes.Pakur Variety
For foundation Blocks of Quadrupped
For spout Chamber
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. normal size) excluding shuttering and reinforcement, if any, in ground floor. as per relevent IS Code. a) Pakur Variety
For foundation Blocks of Quadrupped
For spout Chamber
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor). Above 30mm to 37 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge.
For foundation Blocks of Quadrupped
For Spout Chamber
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel(JSW/SHYAM/SRMB) i)For foundation Blocks of Quadrupped
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation & plinth
125 mm. thick brickwork with 1st class bricks in cement mortar (1 : 4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface.with (1:6) cement mortar, 15 mm. thick plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.
Labour Charges for fitting, fixing and laying, where necessary of following M.S / G.I. / E.R.W. pipes and accessories (to be supplied departmentally) including transportation of the same cutting, threading, jointing and making leak-proof threaded / flanged joint at site, by using socket / rubber insertion, nuts and bolts etc. maintaining proper alignment and level - all complete - as per direction of Engineer-in-Charge.150 mm. dia. ERW pipe.
Erection, fitting, fixing of set of M S Quadruped inlet and outlet pipe fittings for MAJOR RLI Scheme with 1st. And 2nd chamber.(Rate inclusive of transportation from departmental store to work site).
Labour charges for fitting, fixing150 mm. Dia. Alfa-AIfa valve with 160mm. dia. P.V.C. riser pipe with the help of flanged P.V.C. tail-piece by joining the P.V.C. End of Tail-piece and riser pipe with coupler and flanged end of Tail-piece and Alfa-Alfa valve with rubber insertion, nuts and bolts etc. complete.
Labour charges for fitting, fixing (150 mmx200 mm) dia MS expander with 200 mm dia UPVC pipe with the help of FTP (flanged tail piece) by joining the PVC end of the tail piece and 200 mm dia UPVC pipe with coupler and flanged end of tail piece and expander with rubber insertion, nuts and bolts etc complete.(Rate inclusive of transportation from departmental store to work site).
Labour charges for fitting, fixing150 mm. Dia Sluice Valve with rubber insertion, nuts and bolts etc. complete.
Supplying, fitting and fixing including transportation of sign board for identifing the exact location of Major RLI scheme (one at road side and other at site) the board will be made 3 mm thick MS plate of size 300 mm × 600 mm and fitted and fixed on 50 mm GI Pipe of IS 1239/90 (part-1) including cutting, welding and writting of both sides of Sign board. Base - Yellow, and ward Red. Both bottom end of the stands pipe will be grouted in 1:2:4 CC on a single brick flat soiling. This will include one materials and labour complete as per drawing and direction of EIC.
Suppling 1 mtr x 0.6 m x 24 swg MS board contaning list of spout wise water users by making numbers of spout as directed by EIC. The board should have base colour - Black and words - White to be fitted and fixed on the wall of the pump house.
Installation of Electro-Motor Pumping set of any make / brand and for RLI scheme on pump foundation over SAL sleeper by fixing nuts and bolts and making connection of suction hose and foot valve with necessary fittings at the inlet end of the water pump and fitting fixing of 90° M S priming bend, sluice valve and delivery hose with all necessary fittings at the delivery end of the water pump, duly connected with the pipe line, maintaining proper alignment and level including cutting holes on the wall of the pump house where necessary, mending good damages after completion of the works as per direction of Engineer-in-charge. . b) For Major R.L.I. Scheme.
Testing of pipe line system against leakages by filling the distribution chamber with water and supplying water through the entirepipe line net work for at least 4 (four) hour by running the departmental Deasel Engine pumping set, including supplying necessary fuels & lubricants and hiring and transporting tools and plants all complete as per direction of Engineer-in-Charge. For Major R.L.I.
Internel Wiring
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection Legrand Double Pole 32 A
Wiring from MCB SS Enclosure to Busbar by the following size of 1.1KV grade single core stranded 'FR' PVC insulated and unsheathed copper wire (Brand Approved by EIC) in 25 mm PVC casing-capping (Precision make) including necessary PVC clips fittings etc. as required 2X 22/0.3 (1.5 Sq mm) + 1 X 22/0.3(1.5 Sq mm) ECC
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. to light/fan point with piano key type switch (Anchor Make ) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necessary connections and making earthing attachment and mending good damages to building works. [PVC casing capping and Switch board both on surface]
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips fittings etc. with S & F 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on PVC switch board on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]
Supplying and fixing of 6 -32 Amp Single Pole MCB on Switch Board as per direction of E.I.C
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling
Supplying & Fixing bulk head light fitting (Havells make) with die cast aluminium housing & frosted glass on wall/ceiling incl. S&F 8watt CFL / 100 watts GLS lamp complete set
Fixing only of 200 A, 415 V sheet steel TPN main switch on Angle iron Frame on wall 32A to 400A
Fixing only of 4 Bars 200 A, 415 V M.S. sheet metal busbar chamber on angle iron frame on wall .
Fixing only of 63 A, 415 V sheet steel TP main switch on Angle iron Frame on wall
Fixing only of 63 A, 415 V sheet steel TP main switch on angle iron frame on wall
Fixing only of Star Delta starter (for 20 HP motor contol) on angle iron frame on wall with nut and bolts and making necessary connection with electrical cable.
Fixing only Volt meter / Ammeter with Screws and other fixing materials incuding making necessary holes and connections
Fixing and connection Capacitor bank with suitable cable and others necessary materials to the system on a suitable place as per direction of E.I.C
Meter loop connection with 1.1 K.V. Gr. 3½ core, 50 Sqmm P.V.C./ XLPE insulated & sheathed and armoured Aluminium Cable from Meter to incomming TPN Main Switch / Terminal. (Brand: Gloster/Havells/Finolex)
Supplying and Drawing with 1.1 KV, PVC flexible 'FR' cables copper conductor conforming to IS 694 in suitable size with fitting and fixing on wall , including making necessary connection to the pre-fixed devices with all necessary accessories like saddle, screw, clips, gland, socket etc. conforming to IEE regulation and as per direction of EIC.(Brand: Gloster/Havells/Finolex)
4Cx 25 sqmm Copper cable conforming to IS 694 in [100/200 A TPN switch to Bus-bar]
3C X 16 sqmm copper cable conforming to IS 694 [Busbar to 63 A, TP Main switch and 63 A TP switch to Motor starter]
2 X 3C X 10 sqmm copper cable conforming to IS 694 in 32 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor]
Suppling & fixing of EI danger Board 4"x 6" in two distinguishing position . As per IEE regulation
Suppling fitting & fixing of shock treatment chart in a wooden frame. ( Rate as per Market rate)
Earthing with 50 mm dia Galvanized iron pipe 3.64 mm thick X 3.04 mtr. long and 1X4 SWG G.I.(Hot Dip) Wire (4 mtr. Long ) 13 mm dia X 80 mm long G.I. Bolts, double nuts and double washer including S&F 15 mm dia G.I. Pipe protection (1 mtr) long to be fitted with bitumen partly under the ground level and partly above the ground level driven to an average depth of 3.56 mtr. below the ground level. By ISI-Medium G.I. Pipe
Supplying and fixing earth bar of galvanized (hot dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required for tapping.
Connecting the equipments to earth busbar including supplying and fixing G.I. (hot dip) Wire on wall/floor with stapples burried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good all the damages. By Solid 8 S.W.G. GI Wire
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger
Supplying & fixing of wall mounting type Angle Iron frame made from GI angle (Size: 40 mm x 40 mm x 5 mm) thick for fixing of control equipments
Placing and positioning the Centrifugal pump motor set on thepump base / pump house floor, aligning properly with necessarypacking and fixing the set with holding down nuts and washerincluding cutting holes of requisite size in the floor / base, groutingthe bolts and mending good all damages complete as per direction of the Engineer-in-Charge.
Carriage of Departmental materials from the Deparmental Store to the work site and return back the damaged/replaced and unused materials to store including loading & unloading complete at both sides by TempoNan Rikshaw/Mini Truck etc. upto 25 Km distance in one way. For Kiosk Box
Construction of Pump House
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with powdered earth or local sand.
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation & plinth
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure ground floor
40 mm. thick damp proof course with cement concrete (3:1.5:1) (with graded stone chips 20 mm normal size) with water proofing compound of approved brand @0.2% weight of cement including cost of materials over two coats of non-toxic acrylic polymer modified cemetitious water proofing slurry coat complete (Cost of water proffing & non-toxic paint to be paid separately)for underground water retaining structures.(water proffing as per item no.60 and non-toxic paint as per item no.59 (b) of Section C.
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevent IS codes. (i) Pakur Variety
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (When the height of a particular floor is more than 4 m. the equivalent floor ht. shall be taken as 4 m. and extra for works beyond the initial 4 m. ht. shall be allowed under 16 (c) for every 4 m. or part thereof.) (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge. [Vide Page no.42, item no. 36(a) of PWD Schedule ]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel(JSW/SHYAM/SRMB)
12.5 cm. Thick first class brick work in cement morter (1:4) in ground floor including scaffolding, racking out joint etc. Complete for verandha.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints, including throating, nosing and drip course, scaffolding/staging where necessary (ground floor) excluding cost of chipping over concrete surface. (i) with (1:6) cement mortar, (b) 20 mm. thick plaster
(ii) with (1:4) cement mortar, (b) 15 mm. thick plaster
(c) 10 mm. thick plaster
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE : Cement 0.152 cu.m. per 100 sq.m.
M.S gate of Jail type as per approved design made of strong M.S frame work,intermediate stiffeners and round/square bars or angles M.S sheet (not less than 14 gauge) gussetes,cleats etc. including necessary riveting,bolting,welding,locking and hanging arrangements,fitting and fixing complete as per direction of the Engineer-in-charge In ground floor.
M.S or W.I Ornamental grill of approved design joints continuously welded with M.S,W.I Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor (ii)Grill weighing above 16 Kg/Sq mtr. And above(20 Kg/sq.m) (MODE OF MEASUREMENT) The weight of grill will be determind by taking the physical weight of fabricated grill and dividing the same by covered area of the same.
Supplying, fitting and fixing approved quality asbestos cement quality down pipe in positioning with necessary clamps,nails,including making holes in wall, floor etc and cutting trenches in any soil or through masionary concrete structure etc.if necessary and mending good damages including jointing materials complete i)76.2 mm dia.
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. (This item is applicable to new work or old work when the original surface has been exposed by removal of old paint)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With super gloss (hi-gloss) - (iv) Two coats (with any shade except white)
White washing including cleaning and smoothening surface thoroughly. All floors : (c) Three coats (on new works only).
Colour washing with "ELLA" with a coat of white wash priming including cleaning and smoothening surface thoroughly : (ii) External surface (ground floor) (b) Two coats
Energisation Supply of Materials
PCC POLE 9 MTRS. LONG
11 "V" bracket for PCC pole 9 M
11 KV Top Adopter for PCC Pole 9 M
M.S. Channel 75 X 40 MM
M.S. Angle 65 X 65 X 6 MM
MS Flat 65 X 6 MM
11 KV PIN Insulator-5KN-Polymer
11 KV DISC Insulator-45KN-Polymer
Hardware Fitting for 30/50
GI Earth Spike 1833 X 20 MM
GI Stay Set (HT) (1830 X 20 MM)
Porcelain GUY Insulator HT
GI Stay Wire 7/3.15 MM
COND ACSR ROT 50 S. MM.
DTR 63 KVA 11/0.433 KV, 3 PH O/D
1.1 KV PVC 4C 50 S MM AL Cable
LT Distribution Kiosk for 63 kVA TRNF
GI TURN BUCKLE 18 X5/8"
LA 12 kV ( 5 KA) for 11 KV
GI wire 4 mm
GI wire 5 mm
ISL 11 kV 200 A TPGO
D Iron clamp 3" X3.5 "
Porcelain shackle Insulator 3" X 31/2"
Caution Board
Add escalation @5% for 2024-25 on Materials with Sundries i.e from Item Nos. 5.01 to 5.27
Add escalation @5% for 2025-26 on Materials with Sundries i.e from Item Nos. 5.01 to 5.28
Energisation Labour Charges
Survay of HT Line
Erection of 9 m Single pole with fittings
Erection of 9 m DP with fittings
Extension of PCC single pole
Fixing of 11 KV Pin Insulator with pin
Fixing of 11 KV Disk Insulator
Earthing Complete
Stay Set (HT)(1830X20)mm
Fixing of Caution Board
Stringing & Sagging ACSR 50 sq mm 3-Con
Fixing of Tee of bracket on Single Pole
Fixing Isolator on S/Stn Structure
Fixing of 12 KV LA (One set of 3 LA)
Erection of s/stn Structure 9m-DP
Erection of Dist. Transformer 63 KKVA
Fixing of CG on single pole
Lead Wire (2 wire) 30-60 mtr
Making and Fixing of cross lancing wire
DTR Neutral earthing with Material
Survay of LV Line
Fixing of Shackle Insulator With N/B
Fixing of LT Kiosk
Stringing & Sagging of PVC cable
3 PH SERVICE
GIS filled Survay and upadatind GIS mapping of pole
Supervision Charges @15% on item No.6.01 to 6.27
Payment To Wbsedcl For Security Charges , Supervision Charges, Meter rent Etc.
Add Extra Carriage @4% from Item No.2.03 to 2.23 and 4.03 to 4.22
Add GST @ 18 % on PWD and WRDD Items from Item No. 2.01 to 4.22 and Item No.9.00
Add GST @ 18% on Supervision Charges i.e Item No 7.00
Add Cess @1% from Item No.2.01 to 7.00 and Item No.9.00 to 10.00
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 6.99 MB
BOQ_2445998.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid