| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-Finance | L1 | Accepted-Finance Lowest and reasonable bid | |
| 2 | L2₹5.9 L+₹40,525.70 (7.43%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹8.0 L+₹2.5 L (46.4%)Rejected-Finance | L3 | Rejected-Finance Other than the lowest bid | |
| 4 | L4₹8.4 L+₹2.9 L (53.6%)Rejected-Finance | L4 | Rejected-Finance Other than the lowest bid | |
| 5 | L5₹8.5 L+₹3.1 L (56.3%)Rejected-Finance | L5 | Rejected-Finance Other than the lowest bid |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
23 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) SURANUSSI
MIL STN SURANUSSI
REPAIR/REPLACEMENT BLDG SECURITY LIGHT, ELECTRIC SIREN AND SERVICE CONNECTION AND ALLIED WORKS AT 223 ABOD MIL STN SURANUSSI UNDER AGE(I) SURANUSSI
2023_MES_620640_1
AGE(I)S-15/2023-24
Open Tender
Civil Works
Item Rate
270 days
SURANUSSI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) SURANUSSI
₹20,000
Yes
31 Oct 2023
26 Sept 2023
30 Oct 2023
26 Sept 2023
23 Oct 2023
10 Oct 2023
Amount
Attending and rectification / redressal of day to day complaints of street / security light (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects fixed on street light poles 9/11 m long, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement. Note : (i) Disconnecting electrical connections, opening up for inspection and making joint inventories of defects and spaces to be replaced, re-fixing old serviceable spares and fixing new spares in item replacement reasonbling, installing and fixing against in position testing and commissioning equipment of appliances.(i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive etc if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ as a supply only (ii) Contractor shall deploy sufficient number of electricians and helpers as directed by Engineer-in-charge to attend the complaints and reactify the same within 24 hours of receipt of complaints, failing which a penalty of Rs. 300.00 per complaint shall be imposed on contractor besides payment of complaint shall not be allowed. Attendence record of electrician and helpers shall be maintained jointly by the Engineer-in-Charge and Contractor as well. A pucca bound maintainence register shall also be maintained by the Engineer-in-Charge and Contractor as well.(iii) Contractor's representative shall collect the complaints at complaint cell at 8.30 AM to 9.00 AM from JE E/M and report after completion of rectification of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes.(iv) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract. (v) Contractor will deposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints. (vi) Supply only spares (in replacement) shall be measured and paid for separately under respective items of Schedule 'A'. The unit rate quoted by the contractor in this item shall included for the cost of fixing all types of spares, re-fixing, minor parts such as bolts nuts, washers etc. Purchase vouchers and receipt vouchers shall be attached with the RAR and Final Bill. (vii) Each complaint shall be entered in MB mentioning complaint No, date, location, defects detected, work executed, spares replaced etc in a tabular form in the enlarged MB. (viii) Users signature shall be obtained in token of complete redressal / rectification of a complaint. (ix) Cost of minor repairs, replacement of petty items such as nuts, bolts, washers, screws etc. (x) One Complaint rectified is considered is one complaint.
All as per item No. 01 but for 16 metres height high mast lights.
Supply, fix, connect and test in replacement , LED street light fitting 35 Watts (or above watt) IP 65/66 with PDC Aluminium body and toughened glass visor fitted in frame, separate driver compartment provided, secondary optical lens for superior light distribution efficiency >95 Lm/W, CCT5700K IP65, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion. Make : Polycab Cat Part No PCGLS 01 30 Product code PUB0502004 and C&S electric Cat part No LTESS 12 X 2.5 HPLED/LS Product Code INDUS/30W/LS (Model Indus series) or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply, fix, connect and test in replacement, LED flood light fitting 70 Watts capacity having following specification fixture should be having pressure die cast alluminium IP 66 with extended alluminium heat sink with pressure die cast aluminium end caps with seprate control gear unit (b) Fixture should be having PMMA optics for uniform distribution (c) Input voltage 110 V to 300 V AC (d) Surge protection of 5 KV (d) Mechanical protection IK 05 (e) Power factor > 0.95 (f) Lumen/watt 105 Lumen/watt (g) THD > 10% (h) Fixture front cover with polycarbonate encapsulated (j) Fixture having fuse protection short circuit protection and over voltage protection cutt off voltage 110- 310 V having Auto shutdown mode (k) Fixture should be approved from Govt of India ministry of science & Technology (m) Brand name should be enclosed on fixture (n) LED flood light must be having discute LED Structure Make :Bajaj cat part NoPAR0201004 PCGLF 02 60 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.
Supply, fixing and testing in replacement of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete, Make : Havells or equivalent
Supply only MCB SP, 32 to 63 Amp 240 Volts, 20 KA, C-Series, in DB / Junction Box or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed .
Supply only contactor ML-2 with 415 Volt coil AC, 03 rating 32 A, 400 V Cat Part No SS90701 of Make LT complete all as specified and as directed .
Supply only 1100 Volts grade heavy duty cable 3 core 1.5 Sqmm PVC insulated copper stranded conductor passing through and including 20 mm bore PVC pipe for connection pupose of street light fitting from DB to street light fitting by cutting with the cutter and making good in CM 1:3 complete all as specified and as directed.
Supply and fix in replacement ; Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed.
Supply and fix in replacement; MCCB 160 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havell's/ Siemen's/ L & T
Taking down old unserviceable ACSR conductor of any type & size including insulators on LT poles complete all as specified and as directed .
Supply and fix aluminium conductor steel reinforced for overhead lines on poles including aluminium binding wire 14 SWG jumpers, lines tapes etc complete all as specified and directed . of size weasel and mink. Note : for payment purpose weight of ACSR conductor shall be considered. Note : for payment purpose weight of ACSR conductor shall be considered.
Supply, stretch and fix in repacement; continuos earth wire 4 mm dia galvanised steel wire including galvanised mild steel binding wire 14 SWG complete all as specified and as directed by Engineer-in-Charge. Note : for payment purpose weight of 4 mm dia galvamised wire only shall be taken and clamps, hooks shall be measured and paid separetley.
Tightening and restringing existing loose/broken conductor (ACSR/Copper)/GI continuous earth wire any type including stringing including replacement of fresh binding wire all as required at site all as directed.
Supply & fixing MS junction box with front cover of size 250 cm height x 150 cm (w)x 150 cm (D) with two coats of synthatic enamel paint including 3mm thick flat iron clamp with nuts bolts washer etc in and including 4 way 10 Amps connector-01 No, MCB SP 6Amps 230 Volts -01 No, Aluminium Bus Bar, complete and fixing to the same to the bracket with necessary clamps, Nuts and Bolts complete fixed to poles including termination of cable 1.5 sq.mm pvc insulated copper conductor,
Excavating in trenches in soft/loose soil not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenchescomplete all as specified and directed .
Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed .
Removing of surplus excavated soil to a distance not exceeding 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 10 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Supply, lay, joint, test and commission in replacement; under ground XLPE/PVC armoured heavy duty electric cable insulated and PVC sheathed LT with stranded aluminium conductor 1100 vols grade cross sectional area 6 Sqmm 2 core laid in trences, in floor, in duct, through pipes or along the pole complete all as specified and directed.
Material and labour for sand cushioning with sand for plaster to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and punned down to 10cm complete all as specified and directed by Engineer in Charge. Note : 18 cm thickness shall be reckoned for the purpose of measurement and payment.
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat, laid dry with width equal to length of brick, laid across the length of cable complete all as specified and directed.
Supply and fix in replacement; 50 mm bore galvanised iron pipe light grade for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'
Supply and fix GI bracket suitable for street light fitting made out of 40mm dia GI tubing of light grade bent to shape of 1.5m length complete with necessary nuts bolts and MS clamps including taking out old one complete all as directed by Engineer-in-Charge.
Dismantling the electric induction motor with siron (Hooter) assembly 5 HP capacity completely and taking out all the electric winding wires from the slots including cleaning the slots and rewinding the electric motor by supper enamel copper wire suitable size and quantity to convey the actual current on full load including heat varnish complete greasing in bearing reassembling testing complete all as specified and directed.
S&F 30cm long mild steel screw bolts (machine made) with dia. of neck 22mm, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as directed by Engineer-in-Charge.
Taking down damaged stainless steel wire rope from the pole of 10m height and supply and fixing new stainless steel wire rope 6mm dia., of grade 319, 7/19 construction, complete all as directed by the Engineer-in-Charge.
Supply and fixing in repairs PVC insulated unsheathed EPR copper conductor 1100 V grade 5 core multistranded trailing cable 2.5 Sq.mm. complete all as specified and as directed by the Engineer-in-Charge. Make: POLYCAB/ HAVELLS/ GLOSTER/PLAZA
Material and labour for dismantling of damaged high mast from foundation with the help of crane and shifted to safe location, re-installation of high mast on the existing foundation after repairs of High mast all as directed by the Engineer-in-Charge.
Supply & Fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 2 core 10 sqmm cable flat or circular all as specified and directed
Supply & Fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one 2 core 6 sqmm cable flat or circular all as specified and directed
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.
J.K & Company
M/s. Aggarwal Engineers
ARR CONSTRUCTIONS
PAWAN KUMAR GOVT. CONTRACTORS
AGGARWAL ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .