| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.6 LAccepted-AOC 190 B VIJAY BHAWAN SUBHASH CHOWK RATANADA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹6.0 L+₹1.4 L (31.0%)Rejected-AOC | L-2 | Rejected-AOC Rejected being L-2 |
Tender Value
Refer Docs
EMD Value
₹14,400
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF Mount Abu
AGE (I) AF Mount Abu Sirohi Raj 307501
REPAIR MAINTENANCE OF HEATING AND COOLING APPLIANCES AND DAY TO DAY EM MAINT AT AF STN MOUNT ABU AND GURUSHIKHAR
2023_MES_617765_1
8401/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mount Abu
As per NIT
7 documents required · 7 mandatory
₹500
Yes
AGE I AF Mount Abu
₹14,400
Yes
2 Dec 2023
8 Sept 2023
7 Oct 2023
8 Sept 2023
5 Oct 2023
22 Sept 2023
8 Sept 2023 - 15 Sept 2023
Amount
Taking down and refixing ceiling fan, ceiling cable end, dismantling blades and removing fan and blades to store for repair complete all as specified & directed.
S& F in repair condensor 2.5 MFD complete all as specified & directed.
M&L for painting of exhaust/ceiling fans after cleaning of all dust etc, in situ with one coat of synthetic enamel paint by spraying including filling cavaties with filler complete all as specified & directed. Note :- Rate shall be inclusive of taking down and re-fixing of fans in the above item. No claim on this account shall be entertained.
Taking down & refixing of exhaust fan 230 V SP 300mm to 450mm sweep, greasing, cleaning & servicing by unscrewing of blades, capacitor, winding cable, ball bearing cleaning & alike complete all as specified & directed.
S&F arm of exhaust fan of capacity 300 mm sweep to 450mm sweep (Set of 4) including taking down complete all as specified & directed.
S&f blade for 300 mm sweep to 450mm sweep exhaust fan including taking down complete all as specified & directed.
M&L in repair for rewinding of exhaust fan of size 300 mm to 450 sweep with existing gauge copper winding wire with insulation material complete all as specified & directed.
M & L for painting of exhaust fan of any size complete by using synthetic enamel paint by spraying & applying one coat after cleaning/scraping etc complete all as specified & directed. Note :- Taking down and fixing of exhaust fan shall be deemed in this item rate
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M & L Point wiring complete concealed type incl cutting chases in stone wall for conduits and sinkings for boxes , floors etc with 1.5 Sqmm single core multi standard copper conductor PVC (FRLSH) insulated sheathed cable in and incl PVC conduit heavy duty (Wall fitness not less than 1.8 mm) with accessories existing pressed steel terminal boxes (sunk in wall) including new 3.00 mm thick plastic laminated sheet top cover with 1.50 Sqmm PVC insulated unsheathed copper conductor FRLS for common earth and connecting to earth dolly,and making good to walls for:- (a) One light point/exhaust fan/ceiling controlled by one switch one way & ceiling fan with one way switch & regulator.
(b) One socket out let 5 Amps 5 Pin on same board with other switch
(c) One Switch socket Combined 5 Amps 5 pin on independent board
(d) One call bell point controlled by one bell push .
All as per item No 10.00 here-in-before but one switch socket combination outlet 16 Amp power point on Independent board with FRLSH multistranded cable of size 2.5 Sqmm and multistanded insulated copper earth continuity conductor of size 2.5 Sq mm complete all as specified and directed.
Supply & Fix in repair ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed.
Supply & Fix in repair switch 6 Amp 250 V AC one way one module complete all as specified and directed.
Supply & Fix in repair switch socket combined, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fix in repair switch socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
M & L in repair sub main wiring concealed with 2 single core, 6 Sq. mm, PVC insulated unsheathed, multi stranded copper conductor FRLSH cable 1100 Volts grade including 6 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLSH as continuous earth wire drawn through concealed conduit cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wire of size 6 sqmm including conduit/PVC casing/caping shall be measured & paid as one length.
M & L in repair Sub main wiring concealed with 2 single core, 4 Sq. mm, PVC insulated unsheathed,multi stranded copper conductor FRLSH cable 1100 Volts grade including 4 Sqmm PVC insulated unsheathed multi stranded copper conductor FRLSH as continuous earth wire drawn through concealed conduit Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth and connecting to common earth terminals complete all as specified and directed. Note :- (i) Two runs of copper cable and one run of earth wireof size 4 Sqmm including conduit /PVC casing/caping shall be measured & paid as one length.
S&F 12 watt slim surface mounted LED panel with premium diffuser to ensure glare free & even light distribution square LED light fitting complete all as specified and directed.
S & F 12 watt environmental friendly sufrace mounted bulk head fitting with high brightness IP 65 protections complete all as specified and and as directed.
Supply and fix DB single door, SPN 415V, 6 way DBs for using MCBs / MCB isolators complete all as specified and directed including taking down unserviceable DB. Note : Rates are deemed to be included for flashing in wall concealed complete making good and matching existing surface.
Supply and fix Electronic fan regulator 230 volts, step type, socket type, hum free 120 watt complete all as specified and directed.
S & F in repair fly catcher tube rod 18 Watt, 2 feet complete all as specified and directed.
S & F in repair fly catcher choke 18 Watt , UV ballast complete all as specified and directed.
S&F in repair exhaust fan motor single phase, 300mm sweep, 220-240V, 50Hz AC complete all as specified & directed.
S&F in repair exhaust fan motor single phase, 450mm sweep, 220-240V, 50Hz AC complete all as specified and directed.
S&F in repair Plug Top 16 Amp, 3 pin ,240V complete all as specified and directed.
S&F in repair aesthetically designed LED panel for surface mounting which provides soft-light and glare free symmetrical illumination 34 watt, of size 2 x 2 feet LED light fitting, including twin core flexible copper cable for connection of the lights and connectors where required complete all as specified and directed.
S & F Buzzer, ding dong bell, AC, 230V single pole complete all as specified & directed.
Supply & Fix in repair MCB single pole, 6 - 32 Amps 240V in `C’ series having current rating 10 KA complete all as specified and directed.
S & F in repair Modular Fan regulator, stepped type, 2 module, 120 W, 230V AC complete all as specified and directed.
Supply & Fix in repair Modular switch 6 Amp 250 V AC one way one module complete all as specified and directed.
Supply & Fix in repair Modular Switch Socket Combined, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fix in repair Modular Switch Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Supply & Fix in repair Modular switch 16 Amp 250 V AC one way one module complete all as specified and directed.
M&L for maintenance, servicing cleaning of 2 ton split type air conditioner at site, cleaning of equipment with blower for removing dust, checking the wiring, running capacitor, starting relay, overload relay, thermostat switchs condesor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items. (ii) After servicing the said ACs will be fixed to its original position.
Description all as per ser item No 38.00 here-in-before but of capacity 1.5 ton split type
Description all as per ser item No 38.00 here-in-before but of capacity 2 Ton window type
Supply and charging refrigerant F-22/R-22 (Mefron/Refron) gas for 1.5/2.00 Ton Split /Window AC at site after detection and rectification of any leackage in the system by sing CO2 gas and flushing the complete system thoroughly with nitrogen gas complete all as specified & directed.
Description all as per Srl item No. 41.00 here-in-before but R-134 complete all as specified & directed. Note for Srl item No. 41.00 & 42.00 of BOQ/Sch of works : - The cost of nitrogen and CO2 gas used for leakage test and pressure test prior to filling charging gas shall be deemed to be included in this item rate
M&Lfor Maintenance, servicing cleaning of the water dispenser at site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switchs condensor motor, blower/condensor fan rectification of fault, connecting and testing on load complete all as specified & directed. Note : (i) Replacement of spare or gas shall be measured and paid separately under respective items.
S&F in repairs PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity complete all as specified and directed.
Supply & fix starting capacitor 50 mfd for window type room air conditoner 2.0 ton capacity including taking out of old unservicable capacitor complete all as specified and directed.
Supply & fix running capacitor 45 mfd including taking out of old unservicable capacitor complete all as specified and directed.
S&F thermostat switch for 2 Ton window type room air conditioner including taking out of old unservicable swtich complete all as specified & directed.
S&F air filter suitable for window type AC 2 Ton capacity including taking out of old unservicable air filter complete all as specified & directed.
S & F air filter suitable for split type AC 1.5 Ton capacity of existing make and model including taking out of old unservicable air filter complete all as specified & directed.
Maintenance, servicing & repair of refrigerator 165 ltrs capacity any make & model cleaning the various components and replacement of U/s Spares complete all as specified & directed. Note: Spares Will be paid In Other items of schedule.
Taking down, servicing, and refixing of Geyser 25 Ltrs by unscrewing of , MS clamps, inlet , outlet connections, any leakage & alike complete all as specified & directed. Note :- Spare parts will be measured & paid separately
S&F Heating element -1.5 KW including taking down of old u/s heating element complete all as specified & directed.
S&F Heating element -2 KW taking down of old u/s heating element complete all as specified & directed.
S & F thermostat switch for water heater of any size and shape of capacity 1.5/2.0KW including taking down of old u/s thermostat switch complete all as specified & directed.
M& L for PVC connection 15mm x 60 cm long including taking down of old u/s connection complete all as specified & directed.
S&F Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volts 20 Amps rating rupturing capacity 10 KA including taking down of old u/s rusted sheet metal enclosure complete all as specified and directed.
S & F in repair PVC cable connection with Plug 15 Amp of size 3 core 70/.0076 complete all as specified and directed.
S&F in repair Geyser Assembly of any size and capacity complete all as specified and directed.
Shifting of Geaser of any capacity with dismatling and making good the disturbed surfaces cleaning after refixing the geyser including welding work of of any part of geyser if required.
ANKIT BUILDERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .