Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.2 L+₹5.4 L (16.0%)Rejected-AOC | L2 | Rejected-AOC BIDDER NOT LOWEST | |
| 3 | L3₹43.2 L+₹9.4 L (27.9%)Rejected-AOC 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-AOC BIDDER NOT LOWEST | |
| 4 | L4₹43.7 L+₹9.9 L (29.2%)Rejected-AOC | L4 | Rejected-AOC BIDDER NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT
GE WEST DELHI CANTT 10
ESSENTIAL REPAIRS MAINTENANCE WORKS FOR EM COMPLAINTS TO PIRU VIHAR UNDER AGE EM OF GE WEST DELHI CANTT 10
2020_MES_350532_1
GE/DW-68/2020-21
Open Tender
Civil Works
Item Rate
240 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹90,000
17 Sept 2020
24 Jun 2020
23 Jul 2020
24 Jun 2020
21 Jul 2020
9 Jul 2020
60 days
Amount
S&F in Replacement of capaciator 3.50 Mfd, 240 V complete all as specified and directed.
S&F in Replacement of capaciator 2.50 Mfd, 240 V complete all as specified and directed.
S&F in Replacement of lamp holder complete all as specified and directed.
S&F in Replacement of double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F in Replacement of flexible 2 core 1.5 sqmm PVC FRLS copper conductor complete all as specified and directed.
S&F in Replacement of Switch socket combination 6 A 250V AC universal with box in polycarbonate complete all as specified and directed.
S&F in Replacement of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
S&F in Replacement of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
S&F in Replacement of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F in Replacement of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F in Replacement of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
S&F in Replacement of Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
S&F in Replacement of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers complete all as specified and directed.
S&F in Replacement of LED Ultra bright glass LED Tubelight with very high efficiancy suitable for installation in existing fitting 4 ft length complete all as specified and directed.
S&F in Replacement of surface mounted,decorative oval bulk head LED 10 Watt luminaire comprising of high brightness LEDs complete all as specified and directed.
S&F in Replacement of New generation energy saving and environmental friendly long life LED street light made up 25 watt LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection complete all as specified and directed.
S&F in Replacement of surface mounting 22 watt LED tube light fitting of 4 ft length complete all as specified and directed.
S&F in Replacement of 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
S&F in Replacement of 7 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz
S&F in Replacement of 15 amps Plug Top 240 V complete all as specified and directed.
S&F in Replacement of 5 amps Plug Top 240 V complete all as specified and directed.
S&F in Replacement of inner shell Copper body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of inner shell Stainless steel body suitable for geyser of capacity 25 ltr complete all as specified and directed.
S&F in Replacement of Copper Heating Element 1500 watt suitable for Geyser of 25 Ltr capacity complete all as specified and directed.
S&F in Replacement of thermostat suitable to work at water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed.
S&F in Replacement of copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
S&F in Replacement of single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F in Replacement of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates suitable for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and directed. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F in Replacement of Hylam sheet as following various sizes as per site requirement for fixing in switch board including taking down of serviceable switches/sockets/regulators and refixing the same complete all as specified and directed:-
250mmX200mmX3mm (LengthXBreadthXThickness)
200mmX160mmx3mm (LengthXBreadthXThickness)
110mmx110mmx3mm (LengthXBreadthXThickness)
S&F in Replacement of MS Sunken boxes as following various sizes as per site requirement for fixing of switch board including disconnecting electric connection,switch boards including all accessories and making good to disturbed surfaces complete all as directed and specified
250mmX200mmX3mm (LengthXBreadthXThickness)
200mmX160mmx3mm (LengthXBreadthXThickness)
110mmx110mmx3mm (LengthXBreadthXThickness)
S&F in Replacement of of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as directed and specified
S&F in Replacement of 02 runs of IC x 4.00 sqmm (Main Cable and neutral) and one run of IC x 4.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection complete all as specified and directed.
S&F in Replacement of MS outer shell suitable for geyser of capacity 25 ltr complete all as specified and directed.
Checking and attending complaints by means of repairing/rectifying the electric defects/faults related to elctrical equipments ,devices,accessories and fixtures maintained by MES daily except national holidays complete all as specified and directed. Note: 1. This item covers cost of labour for attending complaint comprising taking down of old material and fixing of item issued by the Deptt. 3. Complaints noted'' NO Light'' shall be attended imediately up to 2200 hrs without fail, failing which recovery of Rs. 240.00 per complaint shall be effected from the contractor's dues. 4. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimbles, electric tape etc shall deemed to be included in the quoted rate of this item. 5.The complaint shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed and recovery shall be effected from contractor's dues. In case after checking & attending the defects, if it is not possible to rectify the defects within 08 hrs ie from 0900 hrs to 1700 hrs, the facts shall be brought to the notice of Engr in charge immediately by the contractors/his rep. The decesion of Engineer in Charge to effect recovery on this account shall be final and binding. 6. Contracror shall arrange suitable T&P incl necessary from work and scoffolding and safety measures to make it functional complete all as specified and directed. 7. Contractor or his rep will report daily at complaint cell for collection of complaints from the concerned JE in charge . 8 Job slip as per sample shall be provided by the contractor free of cost. 9. The contractor is advised to inspect site and to note that he has to deploy daily men power to collect the complaints from two complaint cells. Contractor's quoted rates shall deemed to be included this fact into account and nothing extra shall be admissible on this account.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket/power/call bell) complete and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable (phase, neutral and earth wire) in existing concealed conduit, earth wire connected to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing switches/sockets etc with cover plate/3mm thick plastic laminated sheet for the foiiowing complete all as specified and directed. :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
All as per item No. 42 here in before but with 2x2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
Supply, laying and drawing in existing concealed PVC rigid conduit on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store and refixng the same complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed.
M&L for rewinding exhaust fan of 300mm/450mm sweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement of ball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed.
S&F lower shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
S&F lower shutter of exhaust fan suitable for 450 mm size at the height from 3mtr to 30 mtr height making good surface of distubed area complete all as specified & directed. Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed.
M&L for scarapping/cleaning to rusted/pealing area on surface of ceiling fans including sweeps,down rod,fan Hook after cleaning applied two coats of spray painting and numbering complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, ladder and safety measures to make it functional complete all as specified and directed.
M&L for scarapping/cleaning to rusted/pealing area surface of Meter panel after cleaning applied two coats of spray painting by approved colour and numbering also cleaning area of Meter Room dust and unwanted material to be thrown out at out side of defense permises area complete all as specified and directed. Note: Contractor shall arrange suitable T&P including necessary form work, ladder and safety measures to make it functional complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 480640.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
AMIT BROTHERS
jain associates
SETHI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .