Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-Finance | L1 | Accepted-Finance All Conditions Fullfill | |
| 2 | L2₹9.9 L+₹1.4 L (16.5%)Accepted-Finance SALEMPUR ROAD SADABAD HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | L2 | Accepted-Finance All Conditions Fullfill | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Qualify in Conditions | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualify in Conditions |
Tender Value
₹10.3 L
EMD Value
₹12,000
Closing Date
14 Feb 2025, 1:00 pmClosed
SE EDC-1 AGRA
B-690 Kamla Nagar Agra
For the Work of issuing 300 KVA connection in LMV-9 to M/s Larsen nd Tourbo Ltd Site- Khasra No. 1010, Kolarakalan Agra on semi turnkey basis in Full deposit scheme under Electricity Distribution Divison-I, Agra.
2025_DVVNL_1003361_1
46/EDCA/2024-25
Open Tender
Electrical Works
Piece-work
90 days
B-690 Kamla Nagar Agra
As Per Tender Documents
2 documents required · 2 mandatory
₹3,540
DVVNL
₹12,000
21 Mar 2025
7 Feb 2025
14 Feb 2025
7 Feb 2025
14 Feb 2025
7 Feb 2025
Part-A (Supply of Material) Stone pad 300x300x75 mm
Barbed Wire
M.S. Crossing Bracing
Aluminimum Tape
M.S. Nut & Bolt off size
11 KV D.O Fuse Set
Holding Clamp
D.P. Clamp
G.I. Pipe 6" Dia
Part-B (Erection work) Cartiage of 400 KVA T/F from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of PCC Pole 8.5 Mtr. Long from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of STP 11 Mtr. Long from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of 11 KV VCB I/C 600/300/5A 350 MVA 24 V & 11 KV VCB O/G CTR 200/100/5A 350 MVA 24 V from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of 11 KV XLPE 3x120 sqmm Cable & LT PVC Cable 400 sqmm from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of 11 KV Jointing Kit 3x120 sqmm I/D & O/D and Straight Through from store center agra to work of site through Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.(Distance 00-50Kms.)
Cartiage of Line Material from Store Center Agra to work of site through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work..(Distance 00-50Kms.) Line material viz. Aerial bunch conductor/Weasal conductor/Dog/ Rabbit, G.I. earth wire, Top Channel, cross arm, angle, channel, insulators, clamps, Dist. Box, and other line material, if required in Estimate/Package.
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) on Single Pole 11 Mtr. long ST poles including fixing of all accessories for 11 KV line as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) on Double Pole 11 Mtr. long ST poles including fixing of all accessories for 11 KV line as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
Erection and grouting in 1:2:4 ratio (cement, sand and bricks balast) on Single Pole 8.5 Mtr. PCC including fixing of all accessories for 11 KV line as per RESPO norms.Labour, T &P and carrier, grouting material etc. required for proper completion of work shall be done by the contractor at his own cost.
Laying of LT PVC Cable 400 sqmm as per RESPO Norms and direction by superivising by Engineer.
Hoisting and Stringing of 11 KV 3x120 sqmm XLPE Cable overhead with 6" Dia G.I. Pipe includes unroling cutting / megaring & sealing both ends as per Norms. (Above G.I. Pipe 6" Dia provide & fixing by Contractor at his own cost).
Laying, Stringing, Binding of 11 KV 3x120 sqmm XLPE overhead cables on PCC/Round Poles to connecting the Lines as per RESPO NORMS.
Installation of 400 KVA T/F on newly constructed Plinth in proper alignment direction & making HT/LT connection all Cost of labour and T&P which required for completion of work
Laying sagging stringing and binding and jumpering of ACSR Weasel Conductor at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
Laying sagging stringing and binding and jumpering of ACSR Dog Conductor at 11 KV/LT line as per RESPO norms It includes the cost of labour, T & P carrier etc required for proper completion of work.
Filling of 11KV 3x120 sqmm Indoor & Outdoor Jointing Kit and making connection as per direction of supervising engineer.
Filling of 11KV 3x120 sqmm jointing Kit Straight Through and making connection as per direction of supervising engineer.
Installation Testing & Commissioning of 11 KV VCB I/C 600/300/5A 350 MVA 24 V in proper alignment and direction and jointing of earthing strips with help of gas welding and making cable connection including shifting dragging with all other associated works.
Installation Testing & Commissioning of 11 KV VCB O/G CTR 200/100/5A 350 MVA 24 V in proper alignment and direction and jointing of earthing strips with help of gas welding and making cable connection including shifting dragging with all other associated works.
Fixing of TPMO as per RESPO norms and direction by superivising Engineer.
Installation of 11 KV D.O. Fuse set as per RESPO norms and direction by superivising Engineer.
Painting of 11 Mtr. Long ST Poles (12Nos.) with single coat of red oxide primer and Double coat of Aluminium paint as per RESPO norms. (All required material shall be arranged by the contractor at his own cost)
Fixing of 11 KV Pilfer Proof Metering Cubicle as per RESPO norms and direction by superivising Engineer.
Erection and grouting stay of ratio 1:2:4 (cement, sand and bricks balast) as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Fixing of earthing rod as per RESPO norms including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work.
Construction of New plinth for 400 KVA Transformer of size 5’x5’x4’ above the ground lable and 1 feet below the ground. At the bottom there shall be CC pad of brick ballast of size 5x5’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast. On the top of the wall of plint there shall be RCC work in ratio 1:3:6 [Cement, Sand and grit stone] by using 12 mm dai MS bar at distance of 9’’. There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of supervising engineer.
Fencing of 400 KVA T/Fs as per following specification -Fabrication of 50x50x6 mm size MS Angle frame of size 3000x2400mm with 450 mm long angle for grouting the frame and fixing of 2"x1.5", 10 SWG welded wire mesh with MS strip of 24x5mm size all round the frame and drilling 9 mm holes insides of frames at as distance of 300mm for jointing of frame with the help of boslts and nuts including cost of material. The width of panal may vary as per site conditions, Grouting and fixing of angle iron frames in ratio 1:2:4 (cement, coarse sand and stone ballast ) in the pocket of 150x150x150mm all round the plinth and bolting of frames with 25x8 mm size bolts and nuts, Making main gate in front of the plinth of size 3000x2400 mm by making two leaves of size 3000x1200mm size and grouting the same in ratio and method mentioned at item (b) above fixing with hinges with dandlas for locking system & Painting of entire wire mesh angle iron etc. with Bus Green super enamelled pain in two coats on the primer two coats of Red oxide.
for the work of Chemical Earthing for 400 KVA T/Fs as per RESPO Manual.(All material provided by the contractor at his own cost)
Fixing of Stone Pad 300x300x75 mm Make as per RESPO Manual Labour, T &P and carriage etc and other associated works to complete the work. All work shall be born by the contractor at his own cost.
Fixing of Danger Board with Clamp & Bolt on Poles as per RESPO Manual Labour, T &P and carriage etc and other associated works to complete the work. All work shall be born by the contractor at his own cost.
Fixing of Number Plate with Clamp & Bolt on Poles as per RESPO Manual Labour, T &P and carriage etc and other associated works to complete the work. All work shall be born by the contractor at his own cost.
Fixing of M.S. Bolt Nut & Washers as per RESPO Manual Labour, T &P and carriage etc and other associated works to complete the work. All work shall be born by the contractor at his own cost.
Fixing of P.G. Clamps as per RESPO norms and direction of supervising engineer.
Pratham Communication (BID ID -4954252)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .