Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹32.0 LAccepted-AOC | L 1 | Accepted-AOC Being Lowest and FE accepted by TC | |
| 2 | L 2₹35.0 L+₹2.8 L (8.68%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L 2 | Rejected-Finance Other than lowest | |
| 3 | L 3₹36.9 L+₹4.7 L (14.6%)Rejected-Finance | L 3 | Rejected-Finance Other than lowest | |
| 4 | L 4₹38.5 L+₹6.3 L (19.5%)Rejected-Finance | L 4 | Rejected-Finance Other than lowest | |
| 5 | L 5₹38.7 L+₹6.5 L (20.3%)Rejected-Finance | L 5 | Rejected-Finance Other than lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
26 Mar 2024, 6:00 pmClosed
GE (EAST) LUCKNOW
GE (EAST) LUCKNOW PIN 226002
ADDN ALTN CUM SPL REPAIR TO ROOF TREATMENT AND ALLIED WORKS TO BLDG NO P 79 SIGNAL CENTRE AT HQ CC AND PROVN OF DRAINAGE FROM CMIR HQ 41 INF BDE TO NO 3 GATE OF 4 RAJPUT UNDER GE EAST LUCKNOW
2024_MES_644144_1
GE/E/LKO/T-81 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (EAST) LUCKNOW
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE (EAST) LUCKNOW
₹92,000
Yes
1 Jun 2024
26 Feb 2024
2 Apr 2024
26 Feb 2024
26 Mar 2024
12 Mar 2024
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation complete all as specified and directed.
M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6.0 m mean radius built in cm 1:6 complete all as specified and directed
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) as in coping complete all as specified and directed.
M&L for rendering in 15mm thick in CM 1:4 on fair face of block masonry of concrete surfaces finshed even amd smooth with out using extra cement complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (20mm graded aggregate ) as in surface channels and drains complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including necessary forms mould mitred /stopped ends etc complete all as specified and directed.
Returning filling in including spreding leveling watering and well ramming in layers not exc 25 Cm complete all as specified and directed.
Removal of excavated material n.exc 50 m and depositing where dircted at a level not exc 1.5 mtr above the strating point, complete all as specified and directed.
M&L for pre-cast RCC 1:2:4 Type B1 as in cover slab and similar articles with plain face complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for reinforced cement concrete 1:11/2:3 (Nominal mix) using 20 mm graded aggregates as in slabs supported on walls, beams, column etc complete all as specified and directed.
S&F mild steel TMT bar 10 and over,cut to legth bent to shape required incl cranking, binding with mild steel wire (aneaiied) not less than 0.9mm etc complete all as specified and directed.
Use & waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick( horizontal or sloping),flat and fair finished complete all as specified and directed.
Roughining surface of old concrete floor by picking,sweeping,cleaning and washing down with water to remove dust etc and brushing neat cement slury with 3.0 kg of cement per sqm complete all as specified and directed.
Dismantling bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid dry or laid dry and pointed in any mortar complete all as specified and directed.
Demolition of cement conrete of any description and in any position not otherwise specially provided etc. complete all as specified and directed.
S&F of galvanised iron(low carbon) chicken wiremesh of mesh size 25 mm and dia of 0.91mm hexagonal wire netting confirming to IS-3150(1985) for PCC padding work and sanwitched between two layers of PCC on roof top complete all as specified and directed.
M & L for rendering 15 mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified and directed.
Supply only Liquid water proofing compound complete all as spesified and directed.
Removing excavated material exc1 .50m but n exc. 5 Km and depositing where directed etc complete all as specified and as directed
M& L for water proofing treatment to RCC roof slab as under : (a) Priming surfaces and applying bituminous [email protected] kg/sqm over cleaned and dry roof surface including parapet (b) Laying one layer of APP based polymeric membrane 3 mm thick weight not less than 3.6 kg/sqm reinforced with non woven polyster fibre weight not less than 150 gmper sqm and sealed by torch to overlap of 100 mm and 75 mm at end and side of polymeric membrane with applying one coat bitumen 85/[email protected] kg/sqm over APP membranes and two coats aluminium paint @0.2 kg/sqm over membranes etc complete all as specified and directed .
Demolition of brick work built in cement mortar including all of quoins, arches, pillars etc but excluding ashlar facings and precast concrete articles complete all as specified and directed.
Cutting opening through brick wall built in cement mortar for door window and other opening or enlarging existing opening complete all as specified.
Taking down cement plaster on brick walls / ceiling incl. raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed..
M&L for rendering 15mm thick in CM 1:6 brick work or concrete surface and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L preparation of new surfaces of wall and applying two coat of weather proof exterior emulsion paint over one coat of primer on surfaces of wall complete all as specified and directed.
M&L for preparation of new plastered surface of wall including wall care putty 2-3mm thick and applying two coats of oil emulsion distemper (OBD) over a coat of primer complete all as specified and directed.
M&L for Complete removal of exiting treatment and applying two coats of oil bound distemper over one coat of wall care puttyof wall incl preparation complete all as specified and directed.
Taking down 15mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed.
Cutting chases for concealed water tubing and making good to disturbed surfaces in CM1:3, cutting not exc 10cm in girth complete all as specified and directed.
S&F of 15 mm bore steel tube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed.
Taking down 20mm dia GI tubing and connections incl. cleaning for refixing or removal to store complete all as specified and as directed.
S&F of 20 mm bore steel tube, medium grade, galvanised with all fittings such as bends, elbows, tee etc and fixed to walls and ceiling complete all as specified and directed.
Dismantling of water storage tanks exc 500Ltr but n.exc. 1000Ltr capacity and removing from site complete all as specified and directed.
S&F of 1000Ltr capacity rotational moulded polyethylene three layer water storage tanks (cylindrical vertical with closed top), hoaisted and fixed in position complete all as specified in SSR Part–I and complete all as specified and directed.
S&F 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Min wt 15mm-142gms/20mm-210gms/25mm -455gms /40mm-690gms) all as specified
S&F 20 mm dia gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Disconnected PVC water tanks of capacity exc 500 & n. exc 1000 ltr and refixing the same after necessary cleaning and reapir complete all as specified and directed.
Taking down rain water pipes ( any size or pattern) incl all fittings , shoes, bends, swan neck etc complete all as specified and directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall 110mm bore , complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius complete all as specified and directed.
S&F stack clamps out of 50mm by 5mm flat iron round iron stays, including bolts and nuts and securing ends of stay to wall or roof complete all as specified and directed.
Provinding & fixing in repairs with fully perforated 12mm thick micro tegular edge false ceiling at all heights with GRC(Glass Fibre Reinforcement Gypsum)false ceiling tiles of size 595x595mm of approved texture,design and patterns having moisture content less than 2%,humidity resistance of 99%,NRCO0.50 to 0.75 as per IS 8225:1987 Noncombustible as per bs 476 (part)-1970 and light reflectance of 85%(min0 to be laid in true horrizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33 thick (galvanized@120 grams per sqm incl both sides ) comprising of main T runners of size 15x32mm of length 3000mm,cross-T of size 15x32mm of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600mm to form grid moudle of size 600x600mm suspended from ceiling using galvanized mild steel items9galvanizing@80gms per sqm)i.e.50mm long,8mm outer diameter M-6 dash fasteners,6mm dia fully threated hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm galvanised iron perimeter wall angle of size 24x24x0.4mm of length 3000mm to be fixe on periphery wall/partition with help of plastic rowl plugs at 450mm center to center and 40mm long dry wall srews the work shall be carried out as per specification and complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing and rubbish off the premises complete all as specified and directed.
S&F vitrifield ceramic tiles 10mm thick (Square/rectangular) polished area of each tile not exc 0.36 Sqm in floor etc laid over 20mm thick screed bed in CM (1:6) set and jointed in neat cement slurry and pointed in white/coloured cement to match with existing surface complete all as specified and directed.
S&F vitrifield ceramic tiles 10mm thick (Square/rectangular) polished area of each tile not exc 0.36 Sqm in vertiacal surface/skirting etc laid over 15mm thick screed bed in CM (1:4) set and jointed in neat cement slurry and pointed in white/coloured cement to match with existing surface complete all as specified and directed.
S&F mild steel section such as tubular trusses including special shaped washer etc. compete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade ST-240 complete all as specified and directed.
S&F Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering / clading to wall fixed with self taping screw complete all as specified and as directed.
S&F in repairs false ceiling with 4mm thick E-board Everest make white prepainted designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600x600mm having 24mm wide T-section runner made of 0.33mm GI sheet and angle made of 0.45mm, GI sheet suspected with 4mm dia GI wire complete all as specified. Note. All exposed surface of grid work shall be powder coated white complete all as specified and directed.
Taking down chowkat or frame with shutters area exc 1.5 Sqm each but n.exc 4.0 sqm (without taking off the shutters from the frame) including irom mongry and cutting holes for hold fasts & making good complete all as specified & directed.
S&F of Powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F anodised alumium glazed window shutter sliding type using 1.80 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rils 100x44mm Make jindal/Hindalco including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings complete and glazing shall be done by using 5mm thick plain sheet glass complete all as specified and as directed.
S&F of powder coated of any colour aluminium door shutters,/partition aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beadingscrews etc. complete all as specified
S&F of mortice lock 4 leaver brass,vertical type, size100 mm etc. complete all as specified
S&F of prelaminated particle board of 12mm thick, exterior grade, prelaminated both side with decorative choice lamination ,fixed with beading to aluminiume frame work etc complete all as specified and directed.
S&F in repairs 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the new surfaces, complete all as specified & directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified & directed.
Taking down carefully copper/aluminium point wiring ( light, fan, socket , bell or power) complete including all electrical fittings & fixtures (DBs,submain,cables etc) all as specified and directed by Engineer-in-charge.
Taking down Ceiling/wall/Exhaust fan incl ceillling lights/tube lights any type and size & re-fixing the same after completion of wiring including connecting of electric connection of ceiling fan/exhaust fan with three core copper flexible wire 23/0.0076 complete all as specified & directed.
Material and Labour for point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed multi stranded copper conductor single core cable 1100 volts grade in and including PVC conduit with accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light/Ex-fan point controlled by one switch 5Amps SP all as specified and directed. Note :- Sunken box/cover plate for modular switches, sockets etc will be measured and paid seperately under relevant items and blank plate required if any will be deemed included in the item rate.and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall complete all as specified & directed.
All as per Item No 61 hereinbefore but for One 3 pin, 6 A socket outlet on independent Board complete all as specified & directed.
All as per Item No 61 hereinbefore but for One 6 A socket outlet on same Board complete all as specified & directed.
All as per Item No 61 hereinbefore but point wiring complete with 2.5 sqmm for 3 pin 15 A socket outlet on independent board including 2.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor complete all as specified & directed.
S&F Modular white cover plate with frame incl terminal box, 12 Module complete all as specified & directed.
S&F Modular white cover plate with frame incl terminal box, 8 Module complete all as specified & directed.
S&F Modular white cover plate with frame incl terminal box 6 Module complete all as specified & directed..
S&F Modular white cover plate with frame,incl terminal box 3 Module complete all as specified & directed.
Supply and fix Modular switch one way 6A 230V AC 50 HZ SP one module complete all as specified & directed.
Supply and fix Modular switch one way 16A 230V AC 50 HZ SP one module complete all as specified & directed.
Supply and fix Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two modulecomplete all as specified & directed.
Supply and fix Modular socket 6A/16A 2/3 pin combined 230V AC 50 HZ SP two module complete all as specified & directed.
Supply and fix PVC Ceiling rose ,6 Amp,250 volt,AC, ISI marked with thrtee equal size terminals and PVC/Polycarbonate insulated body of 50x25 mm size complete all as specified & directed.
Supply and fix of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20 W to 22W with a nominal system lumen output of 2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum with powder coating & with IP20 protection. The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95. Average life L70B50@25000 hours complete all as specified and directed by Eng-in-Charge.
Supply and fix of LED 2x2 architectural recessed luminaire with CRCA housing and Molded PC diffuser with an unique angular optics for making the illumination easy on eyes for light comfort in office areas with UGR<=19. The luminaire should have a color consistency SDCM< 5, CRI > 80 and choice of CCT: 5700K, 2x2 ceiling with an inbuilt sensor thus avoids unwanted hassle of creating space for sensors helps save additional 40%* energy,luminaire should provide 360 Deg coverage around 8 ft area,High on aestheties,Syestem wattage:36/37 W with system lumen of 3700/4200Im, system efficacy>100 Im/watt,Housing made with CRCA material,high transmittance PC diffuser to provide uniform light intensity distribution ,IP20, THD<10%, available CCT: 4000K/5700K/6500K, CRI>80,PF>0.90, Operating voltage: 220-240 VAC at rated frequency of 50 Hz The metallic electronic driver shall have a power factor >0.95, THD <10%, 4KV internal surge protection and the Ripple factor should be <5% to minimise the Flicker and Stroboscopic effect. The driver should be complied with Fixed output/DALI/POE version. Fixture should have an operating voltage range of 140-270VAC. It should have over voltage protection @320V Cut-off with auto restart features. The luminaire has been designed to be Compliant to relevant attributes in LEED V4.0, WELL V2.0 for for Green Building and Human Comfort respectively complete all as specified & directed.
Supply and fixing recess mounting LED light fitting 2'x2 luminaire sensor based ( Motion sensor) 36 Watt efficacy of at least 120Lm/W and maximum system wattage of 36 Wat, designed for ambient temp 45 deg C complete all as specified and directed by engineer in charge.
Supply and fixing Wall Fan 400 mm sweep complete all as directed by Engr-in-Charge.
Supply and fix in repair of MCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works complete all as specified & directed.
Supply and fix in repair of MCB DB VTPN 4 way double door type suitable for TP/FP including necessary dummy plate and necessary civil workscomplete all as specified & directed.
Supply and fix MCB SP 230V, 6-32 Amps capacity complete all as specified & directed.
Supply and fix MCB SPN 230V, 40-63 Amps capacity complete all as specified & directed.
Supply and fixing MCCB FP 415V, 160 Amp 25k capacity complete all as specified & directed.
Suply and fixing 4P Islator 415V, 63-100 Amp complete all as specified & directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through & including PVC Conduit pipe 20 mm dia with all fittings complete all as specified & directed.
Material and Labour for Submain wiring with 2 runs of FRLS grade PVC copper conductor cable 6 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 6 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings complete all as specified & directed.
Material and Labour for Submain wiring with 4 runs of FRLS grade PVC copper conductor cable 16 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 10 Sqmm drawn through and including PVC Conduit pipe 20 mm dia with all fittings complete all as specified & directed.
Supply and fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one 20amps SPN MCB complete all as specified & directed.
QUALITY CONSTRUCTIONS CO
M/s Ramesh Chandra
H R ENGINEERS
SAAR CONSTRUCTIONS
Tecj Nirmaan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .