Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical found in order |
| 2 | Accepted-Technical | Accepted-Technical found in order |
| 3 | Accepted-Technical | Accepted-Technical found in order |
Tender Value
₹5.2 L
EMD Value
₹10,346
Closing Date
29 Jul 2026, 12:00 pmClosed
AC_ELECT
FTR HQ BSF JAMMU
Repair and maintenance of existing panel and power supply cable of Nalapar SFA Type-I Qtr No. from (01 to 68) Paloura campus Ftr HQ BSF Jammu
2026_BSF_918623_1
25/AE(Elect)/NIT/Ftr JAMMU/Engg/2026-27
Open Tender
Electrical Works
Works
60 days
BSF CAMPUS PALOURA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹10,346
18 Aug 2026
22 Jul 2026
31 Jul 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
22 Jul 2026 - 29 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and laying of following 3.5X50 sqmm one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor,armoured underground cable as per IS 7098 (Part-I) 1988 with upto date ammendments of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering (Make:Havells/Polycab/Fenolex/L&T/RR Cabal make) | 200 | Mtr | 100 | ₹20,000 |
| 2 | Supplying and laying of 3.5X50 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/FInolex/L&T/RR Cabal make) | 100 | Mtr | 100 | ₹10,000 |
| 3 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 100Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) | 5 | Each | 100 | ₹500 |
| 4 | Providing and fixing of Switch Disconnector Fuse Open Execution (QSA - Series) Conforms to IS-13947 - Part I & III / IEC-947 Part I & III, AC-23A, 415V, 50 Hz, 250Amps. Rating, in the existing panel connection testing and commissioning etc as required. (Make: HPL/Havells/Legrand/ABB/Anchor/L&T/Schneider make) | 1 | Each | 100 | ₹100 |
| 5 | Repairing of existing complete meter box panel having set of 04 Nos Qtrs each, cleaning, removing of existing burn/defective cables, dismantling of existing switches, priming and painting of panel, fixing of panel cover connection of existing cables, repairing of existing cable connection including connection of incoming cable and outgoing submain etc. as required. | 12 | Each | 100 | ₹1,200 |
| 6 | Repairing of existing out-door panel cleaning, removing of existing switches, burn/defective cables, excavation of nearly panel and to check the Loop i/c Providing and fixing of back side MS Sheet cover 2.0 mm thick size 1.0 Sqm suitable for existing panel, priming and painting of panel, connection of existing cables after repairing etc. as required. | 1 | Job | 100 | ₹100 |
| 7 | Supplying and laying of 3.5X35 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cable make) | 29.5 | Mtr | 100 | ₹2,950 |
| 8 | Supplying and laying of 3.5X120 sqmm PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade, aluminium conductor, armoured cable as per IS 7098 (Part-I) 1988 with upto date ammendments. 3.5X50Sq mm size in the existing RCC/ HUME/METAL pipe/In air as required. (Make:Havells/Polycab/Finolex/L&T/RR Cabal make) | 20 | Mtr | 100 | ₹2,000 |
| 9 | Providing and fixing of Single Phase kWh meter two wire static electronic meter with LCD display, 1P LCD Meter 5-30A, Fixing in the existing panel connection etc. as required. (Make : Cat. No. L&T/Seimens/HPL Make) | 28 | Each | 100 | ₹2,800 |
| 10 | Providing and fixing of TPN MCB 'C' Curve 63Amp. Fixing in the existing panel connection etc. as required. (Make : Cat. No. Havells/Schneider/L&T/ABB/BCH/C&S Make) | 4 | Each | 100 | ₹400 |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_965365.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .