Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67,058.95Admitted-Finance | ₹67,058.95 | L1 | Admitted-Finance |
| 2 | L1₹67,058.95Admitted-Finance | ₹67,058.95 | L1 | Admitted-Finance |
| 3 | L2₹67,236.86Admitted-Finance | ₹67,236.86 | L2 | Admitted-Finance |
| 4 | L3₹67,891.98Admitted-Finance | ₹67,891.98 | L3 | Admitted-Finance |
| 5 | L4₹72,282.08Admitted-Finance | ₹72,282.08 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARORA ENGINEERS L3 | HIMAALAYA ICE L2 | SAMURAI ELECTRICALS PVT LTD L4 | NAVODAYA POWER EQUIPMENT L5 | MAHARIA ENTERPRISE PVT LTD L1 | ELECTROMECH TRANSFORMERS L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Loading of CTPT at Nigam's store; Unloading and opening of CT-PT sets cover, draining oil if any, de-tanking Core & coil assembly assessment and estimation for repairs and replacement of parts, cleaning washing of dust/rust and dirt from all parts including core, tank & re-tanking after replacement of parts/repairs as required, filling fresh new transformer oil taking CT PT Sets for routine tests as mentioned in specification as per relevant ISS and after satisfactory repairs & testing loading of CT PT sets at the contractors works after making and providing grey paint etc. including To and fro transportation of the CT PT set between Nigam stores to contractor’s works. and unloading of repaired CTPT at NIgam's stores | 1 | Per CT-PT Set | - | - | - | - | - | - |
| 1.01 | For 11 KV CT PT | 1 | Per CT-PT Set | 4,450 ₹9,322 | 4,410 ₹9,257.10 | 4,450 ₹9,735 | 4,500 ₹10,014.99 | 4,405.6 ₹9,246.01 | 4,405.6 ₹9,246.01 |
| 1.02 | For 33 KV CT PT | 1 | Per CT-PT Set | 7,110 ₹14,112.80 | 7,110 ₹14,095.10 | 7,250 ₹14,514 | 7,500 ₹15,269.99 | 7,104.03 ₹14,082.16 | 7,104.03 ₹14,082.16 |
| 2.00 | Supply of following damaged parts requiring replacement complete in all respect. | 1 | as follows | - | - | - | - | - | - |
| 2.01 | Primary & secondary of PT (all the coils of three phases). | 1 | Per Kg | - | - | - | - | - | - |
| 2.01 | For 11 KV CT PT | 1 | Per Kg | 1,430 ₹1,687.40 | 1,430 ₹1,687.40 | 1,480 ₹1,746.40 | 1,433.8 ₹1,691.88 | 1,427.8 ₹1,684.80 | 1,427.8 ₹1,684.80 |
| 2.01 | For 33 KV CT PT | 1 | Per Kg | 1,430 ₹1,687.40 | 1,430 ₹1,687.40 | 1,480 ₹1,746.40 | 1,433.8 ₹1,691.88 | 1,427.8 ₹1,684.80 | 1,427.8 ₹1,684.80 |
| 2.02 | A-Primary of each CT | 1 | Per Kg | - | - | - | - | - | - |
| 2.02 | For 11 KV CT PT | 1 | Per Kg | 1,430 ₹1,687.40 | 1,430 ₹1,687.40 | 1,480 ₹1,746.40 | 1,433.8 ₹1,691.88 | 1,427.8 ₹1,684.80 | 1,427.8 ₹1,684.80 |
| 2.02 | For 33 KV CT PT | 1 | Per Kg | 1,430 ₹1,687.40 | 1,430 ₹1,687.40 | 1,480 ₹1,746.40 | 1,433.8 ₹1,691.88 | 1,427.8 ₹1,684.80 | 1,427.8 ₹1,684.80 |
Tender Value
₹2 Cr
EMD Value
₹4 L
Closing Date
24 Feb 2026, 2:00 pmClosed
SE (MM) AVVNL AJMER
O/O SE (MM), AVVNL, VIDYUT BHAWAN, PANCHSHEEL NAGAR, MAKARWALI ROAD, AJMER
Rate contract for repair of 33 KV and 11 KV CT-PT Sets of various ratios under TN-2091
2026_AVVNL_533787_1
TN-2091
Open Tender
Repair and Maintenance Works
730 days
SE (MM) AVVNL AJMER
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹2,950
SR. AO EA AND CASH AVVNL AJMER and MD RISL JAIPUR
₹4 L
Yes
6 Apr 2026
2 Feb 2026
25 Feb 2026
2 Feb 2026
24 Feb 2026
2 Feb 2026
2 Feb 2026 - 24 Feb 2026
Loading of CTPT at Nigam's store; Unloading and opening of CT-PT sets cover, draining oil if any, de-tanking Core & coil assembly assessment and estimation for repairs and replacement of parts, cleaning washing of dust/rust and dirt from all parts including core, tank & re-tanking after replacement of parts/repairs as required, filling fresh new transformer oil taking CT PT Sets for routine tests as mentioned in specification as per relevant ISS and after satisfactory repairs & testing loading of CT PT sets at the contractors works after making and providing grey paint etc. including To and fro transportation of the CT PT set between Nigam stores to contractor’s works. and unloading of repaired CTPT at NIgam's stores
For 11 KV CT PT
For 33 KV CT PT
Supply of following damaged parts requiring replacement complete in all respect.
Primary & secondary of PT (all the coils of three phases).
For 11 KV CT PT
For 33 KV CT PT
A-Primary of each CT
For 11 KV CT PT
For 33 KV CT PT
B- Secondary
For 11 KV CT PT
For 33 KV CT PT
Outdoor single porcelain Bushing without arcing horns as per relevant ISS.
For 11 KV CT PT
For 33 KV CT PT
Bushing rod with other metal parts including nuts (indicate material & size of bushing rods)
For 11 KV CT PT
For 33 KV CT PT
Set of gaskets (rubberized cork sheet).
For 11 KV CT PT
For 33 KV CT PT
Under base channels with suitable fixing holes for mounting on platform/poles.
For 11 KV CT PT
For 33 KV CT PT
Earthing terminals.
For 11 KV CT PT
For 33 KV CT PT
Glass for oil level gauge with marking for min. oil level.
For 11 KV CT PT
For 33 KV CT PT
Detachable roller assembly.
For 11 KV CT PT
For 33 KV CT PT
Secondary Terminal connectors of suitable size if required.
For 11 KV CT PT
For 33 KV CT PT
Fresh transformer oil of standard quality with ISI mark.
For 11 KV CT PT
For 33 KV CT PT
Sundry items viz
Cover bolts.
For 11 KV CT PT
For 33 KV CT PT
Plugs /caps.
For 11 KV CT PT
For 33 KV CT PT
Insulation material.
For 11 KV CT PT
For 33 KV CT PT
Screws, washers.
For 11 KV CT PT
For 33 KV CT PT
Denting/welding etc. if required.
For 11 KV CT PT
For 33 KV CT PT
Rating and Diagram plate.
For 11 KV CT PT
For 33 KV CT PT
Painting of CT-PT sets.
For 11 KV CT PT
For 33 KV CT PT
Inside with one coat of primer and two coats of zinc chromate best paint.
For 11 KV CT PT
For 33 KV CT PT
The out side of CT-PT sets with primer and two coats of Grey paints and making after de-rusting.
For 11 KV CT PT
For 33 KV CT PT
If the estimate is found uneconomical & inspection charges to be paid for assessment of repair involved and estimation.
For 11 KV CT PT
For 33 KV CT PT
Filtration charges of new transformer oil.
For 11 KV CT PT
For 33 KV CT PT
Secondary Terminal box with cover having sealing arrangement.
For 11 KV CT PT
For 33 KV CT PT
Rate of salvage retained @ 15 % less than the rate of respective rate of copper scrap and at the rate of for other scrap published in the Economic Times on the date of joint estimation agreed. (Fill 1 for Yes and 0 for No in Exworks)
For 11 KV CT PT
For 33 KV CT PT
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.06 MB
GCCSectionII.pdf
Tender Documents • 0.23 MB
ITB.pdf
Tender Documents • 0.07 MB
TechSpec2091.pdf
Tender Documents • 2.81 MB
BOQ_952446.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid