Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
28 Oct 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Senior Manager (P)
HPPTCL, PIU Bhabanagar
Refer Tender Documents
2026_HPPTC_145867_1
HPPTCL/Bhaba/TENDER/2025-26/17
Open Tender
Civil Works
Item Rate
45 days
400/220/66 kV GIS Wangtoo
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹19,200
15 Oct 2026
15 Oct 2026
29 Oct 2026
15 Oct 2026
28 Oct 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm | 166.2 | Sqm | - | - |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar | 16.62 | Cum | - | - |
| 3 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm. | 166.2 | Sqm | - | - |
| 4 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - : 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size) | 16.62 | Cum. | - | - |
| 5 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer along with two coat of black enamel paint all complete. | 1,311.17 | Kg | - | - |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 60.24 | Sqm | - | - |
| 7 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. | 8 | Nos. | - | - |
| 8 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter | 52.9 | M | - | - |
| 9 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. | 20 | Nos | - | - |
| 10 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm | 10 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
TenderDocuments_Volume-I ITB & GCC_Annexures.pdf
Tender Documents • 0.27 MB
TenderDocuments_Volume-I ITB & GCC_Section-1 Information and Instructions.pdf
Tender Documents • 0.44 MB
TenderDocuments_Volume-I ITB & GCC_Section-2 General Conditions of the Contract.pdf
Tender Documents • 0.40 MB
TenderDocuments_Volume-I ITB & GCC_Section-3 Additional Conditions of Contract.pdf
Tender Documents • 0.19 MB
TenderDocuments_Volume-I ITB & GCC_~$ction-1 Information and Instructions.docx
Tender Documents • 0.00 MB
TenderDocuments_Volume-II Technical Specifications_Volume-2 Technical Specifications.pdf
Tender Documents • 0.28 MB
TenderDocuments_Volume-III Drawings_BridgeDrawing.pdf
Tender Documents • 0.34 MB
TenderDocuments_Volume-III Drawings_Volume-III Drawings.pdf
Tender Documents • 0.21 MB
TenderDocuments_Volume-III Drawings_~$lume-IV Drawings.docx
Tender Documents • 0.00 MB
BOQ_217341.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .