| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹45.8 L+₹3.3 L (7.79%)Rejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹48.2 L+₹5.7 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹53.2 L+₹10.7 L (25.2%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹46.2 L
EMD Value
₹92,460
Closing Date
13 Sept 2024, 6:00 pmClosed
GE CENTRAL KHADKI
GE CENTRAL KHADKI RANGE HILLS ROAD KHADKI PUNE-411003
PROVN OF BOOM BARRIERS ALONG WITH ALLIED SERVICES AT SECURITY GATES IN BEG AND CENTRE KHADKI AND DIGHI COMPLEX AND PROVN OF 20 X AIR CIRCULATING FANS WITH CONNECTION IN BAY B IN SSS SHED AT A PARK OF CAFVD UNDER GE (CENTRAL) KHADKI.
2024_MES_666988_1
8966/E8 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CAFVD area
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE CENTRAL KHADKI
₹92,460
Yes
30 Dec 2024
20 Jul 2024
16 Sept 2024
20 Jul 2024
13 Sept 2024
5 Aug 2024
20 Jul 2024 - 29 Jul 2024
Amount
Supply and install Electrically operated fully automatic Boom Barrier K4 crash rated hydraulic based boom barrier with following components :- (a) K4 crash rated hydraulic based barrier with 5 mtr clear opening. (b) Controller and logic circuits complete. (c) It should be duly crash tested barrier under ASTM/DOS/PAS 68/IWA 14:2013 std with less than or equal to 0.5 mtr dynamic penetration. (d) It should be efficient to withstand the front impact of minimum 6.8 Ton ( or more) vehicle travelling at the speed of 48 kmph (K4 rating) with less than or equal to 0.5 mtr dynamic penetration. (e) A physical crash test certificates issued by authorised permier testing agnecy in the name of OEM for the respective model no as quoted for (KARCO/TRL/MIRA/CTS). Complete contact details of issuing agency to be given for independent validation. (f) Height of barrier should be minimum 950mm or as specified in the crash test certificate as measured from top of the foundation frame to the top of the barrier. (g) Barrier should operate under the extreme temperature of -20 degree to +60 degree centigrade. (h) Boom barrier should have control panel for operation. (j) In case of power failure there must be a provision of manual operation. (k) Inherent safety features for safety against vehicles and human needs to be provided. (Contd...2)
(Contd from,,...1) (l) Duty cycle should be 100% and should operate on 420 VAC. (m) The crash rated barrier manufacturer/system integrator should have quality certificates for ISO 9001:2015 and safety certificates like ISO 45001 from reputed certifying body like TUV,BV,SGS. Makes : Godrej / Gunnebo /Tescon /Swaraj/ Automatic/ ATG Access NOTE :- The rate quoted by the tenderer shall include for supply, installations, testing, commissioning of Boom barrier including necessary foundation and cable work and making good to disturbed surfaces as per existing complete all as specified and directed by Engr-in-Charge.
Supply and install Electrically operated fully automatic Boom Barrier with following specifications :- (a) Design :- Reliable gear motor and sturdy steel case, Motwane Boom Barrier has been carefully tested to ensure its correct functioning both in very cold and very hot climate and its functional compatibility. (b) Technology : Micro Controller Based Boom Barrier controller with Logic for Motor, Safety Sensors and Loop detector etc. The Boom Arm is lifted up by 360 degree gearbox. (c) Housing material :- Mild Steel Powder coated (d) Housing aesthics : Corrosion Free : Dry finishing process that uses finely ground particles of pigment and resin that are electrostatically charged and sprayed onto Housing (e) Protection : All Housing and internal parts are be rust & corrosion free metals and alloys of high strength with suitable Epoxy coating. (f) Material of boom arm : The new wind-resistance Arm is extruded aluminium with octagonal profile. (g) Boom Arm Dimension : 80mm*45mm*1.5mm (h) Boom arm length : 6 mtr (j) Boom arm speed : 6 sec (k) Housing height : 925 mm approx. (l) Housing width :- 335 mm approx. (m) Housing length : 290 mm approx. (n) Power Supply : 230V±10%, 110V±10%, 50/60HZ (o) Control Circuit operating voltage : 24 V DC (Contd....4)
(Contd from,,....3) (p) Nominal power Consumption : 50 W in stand by mode and 200 w in operational condition (q) Intellegence : PIC 8-bit CMOS FLASH Microcontrollers Controller based with High performance RISC CPU. (r) Safety logic control :- An advanced system for reversing boom arm on obstacle (s) BoomArm Rest : 6 mtr (t) Wireless control : RF remote control, specially for carrying security guards. and Wireless Push Button, specially for security cabin (u) Interface : RS485 Communication module (v) MTBF : 5 Million Cycles (w) MTTR : 30 Min (x) Power failure : In case of power failure, using advanced manual clutch key the boom Arm can be opened. (y) Ambient Operating Temperature: - 45° to +75° C (z) Protection :- IP 54 MAKE :- Gunnebo, TESCON, Godrej, MAGNETIC NOTE :- The rate quoted by the tenderer shall include for supply, installations, testing, commissioning of Boom barrier including necessary foundation and cable work and making good to disturbed surfaces as per existing complete all as specified and directed by Engr-in-Charge.
Supply and fix MCB DB 8 way , double door, SPN, 415 volts with 200 Amps bus bar complete all as specified and as directed.
Supply and fix MCB TPN upto 32 Amps, 415 volts with breaking capacity 10 KA complete all as specified and as directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of cable/pipe and getting out in head and dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engr in Charge.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr in Charge .
Material and labour for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for foundation of Pole, Transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path etc complete all as specified and directed.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, XLPE insulated, armoured, heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, heavy duty cable served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 4 core complete all as specified and as directed. MAKE :- Polycab/KEI/Gloster/Havells
Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS 16205 & IS14930 ( Part I and II) for protection of underground cable of size 40 mm outer dia with all fittings such as clamps. coupler etc complete all as specified and as directed.
Material and labour for earthing complete with galvanised steel pipe electrode 40mm bore medium grade 2.5 mtr length buried directly and preferable vertically in ground with top edge not less than 1.25 mtr below ground level connected to earthing lead of 4mm GI or steel wire all as shown in Plate No 2 to the earthing test point all as specified and directed.
Material and labour for point wiring for five pin socket outlet 15 Amps & 5 Amps on independent board using 2.5 Sqmm two run and one run 2.5 Sqmm (nominal area) standard copper conductor cable in PVC conduit of suitable size but not less than 20mm including all fittings such as elbow , bends, junction boxes, saddles, etc on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) tistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 2.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting , switches, sockets etc. with 3 mm thick plastic laminated sheet cover for light point controlled by one light point controlled by one switch icnuding making good the distrubed wall and painting the same with matching to existing wall all as specified and directed by Engr -in -charge.
Supply and fixing switch flush type , 15 Amps , single pole , one way 230 volts AC circuit complete all as specified and directed.
Supply and fixing socket outlet 2 in 1 3 pin 5 and 15 Amps flush type 230 volts AC circuit complete all as specified and directed.
Supply and fixing Air circulator 600 mm sweep 20 volt with complete accessories all as specified and directed. MAKE :- Usha/Crompton/Bajaj/Havells
Horizon Construction (BID ID -3094929)
Om Construction (BID ID -3090030)
Rajan Traders (BID ID -3095328)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .