| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.5 L+₹3.6 L (36.2%)Rejected-Finance H NO 257 1ST FLOOR KAMALA NEHRU NAGAR BATHINDA PB | BATHINDA | BATHINDA | PUNJAB | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.7 L+₹3.9 L (39.0%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹17.6 L+₹7.7 L (78.4%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF)BHISIANA
GE(AF)BHISIANA pin-151201
As per BOQ/ Price Schedule
2023_MES_625613_1
GE/BHI/T-21/2023-24
Open Tender
Civil Works
Item Rate
150 days
GE(AF)BHISIANA
As per NIT/ Tender documents
6 documents required · 6 mandatory
₹500
GE(AF)BHISIANA
₹50,000
24 Jan 2024
30 Oct 2023
30 Nov 2023
30 Oct 2023
28 Nov 2023
14 Nov 2023
30 Oct 2023 - 11 Nov 2023
Amount
Taking down Cement Plaster on brick or stone masonry including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete and as directed by Engineer-in-Charge.
M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls/Concrete Surfaces including finishing the surface even and fair without using extra cement, complete and as directed by Engineer-in-Charge.
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the Ratio 1:1:1 shall be applied and finish Even complete and as directed by Engineer-in-Charge.
M&L for complete removal of existing treatment by using mechanical steel brushes from undecorated surface of wall or concrete surfaces by electric sand paper grinder machine, washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge.
M&L for Priming plastered/unplastered surfaces with alkali resistant primer on external surface of wall over Old/ New brick or Concrete surfaces, complete all as specified & directed.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm using high quality brush/ hand roller, complete all as directed by Engr-in-Charge.
M&L for preparation of old surfaces of brick/ concrete and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm using high quality brush/ hand roller, complete all as directed by Engr-in-Charge.
M&L for Removing of bushes upto 10cm dia trunk, grass from roof top, racking out joints/ pointing to brick tiles laid flat and flush pointing with 1:3 cement mortar compound, complete all as specified and directed.
S&F in repairs PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, Single Socketed, in any length with Rubber Ring Joints fixed to Walls complete all as specified and as directed.
S&F in repairs PVC (SWR) 110mm bore (dia), Bend any type, provided with Access Door, etc. and jointing with Solvent Cement , complete all as specified and as directed.
M&L for providing Reinforced cement Concrete type B-1 (1:2:4) using 20mm graded aggregate as in Roofs, Floors (Other than ground floor), beams, staircases, landing, chajjas and similar suspended work including demolition of RCC work fully/ partially ( reinforcement cut as required to facilitate demolition) complete all as directed by Engr-in-Charge.
M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges, etc., Rough Finished Surfaces of Concrete, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length bent to shape required, including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with Clips, complete all as specified and as directed.
Material and labour for rendering 10 mm thick cement plaster in CM(1:3) on fair faces of concrete or brick surfaces and finishing the surfaces even and fair without using extra cement ,complete all specified and directed by Engineer in Charge.
M&L for preparing Old Treated/Painted Steel and Iron Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete and as directed by Engineer-in-Charge.
M&L for Writing letters or figures (Block, Roman, Italic or Indian) not exc 30 cm high shall be painted with thick paint, so that they stand out boldyand solidly without showing signs of brush marks complete and as directed by Engineer-in-Charge.
Demolition of Brick work built in Cement Mortar and in any Position including all Quoins, arches and Pillars, etc., complete and as directed by Engineer-in-Charge.
M&L for Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete and as directed by Engineer-in-Charge.
M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls/Concrete Surfaces, plastered surfaces finished Even and Fair without using Extra Cement and applying two or more coats of 100% premium acrylic emulsion exterior paint over and a coat of primer after preparation of new plastered surfaces, complete and as directed by Engineer-in-Charge..
Demolition of cement concrete in ground floors and paving not exc 15 cm thickness (below or above ground level) and removal of debries from MD land complete all as specified and as directed by Engineer in Charge.
M&L for 50mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection complete all as specified and as directed by Engineer in Charge.
Taking down cement plaster on brick or stone masonry Including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer in Charge.
M&L for 15 mm thick plaster in 1:4 cement mortar and finishing the surface even and smooth without using extra cement including applying two coat of cement base paint over and after preparation of new plastered surfaces, complete all as specified and as directed by Engineer in Charge.
M&L for Post anti termite treatment by providing and injecting chemical emulsion for post constructional anti-termite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sqm of the vertical surface of the sub structure to a depth of 300 mm including excavating channel along the wall and rodding etc complete all as specified and as directed by Engineer in Charge.
M&L for injecting chemical (Chlrophyriphos 20 EC or Indane 20 EC) ISI marked emulsion for post constructional Anti termite treatment along the external/internal wall below tiles/concrete floor or masonry area using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes @300mm min spacing etc and making good disturbed portion complete all as specified and as directed by Engineer in Charge.
M&L for post constructional Anti Termite Treatment at points of contact of wood work by chemical emulsion (Chlrophyriphos 20 EC or Indane 20 EC) ISI marked (mixing 1% oil or kerosene based solution by weight of chemicals) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same and making good disturbed portion complete all as specified and as directed by Engineer in Charge.
SUBHASH ARORA CONSTRUCTION CO
SWARN SINGH AND CO.
GUPTA AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .