Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹35.6 L+₹3.0 L (9.27%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹36.7 L+₹4.2 L (12.8%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
| Sl No | Description | Qty | Unit | M/S Yamin L3 | NAVYUG VYAPARI L2 | PARAS ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed . | 3.13 | Cum | 100 ₹313 Lowest | 100 ₹313 Lowest | 100 ₹313 Lowest |
| 2.00 | M&L for Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed . | 2 | Cum | 4,000 ₹8,000 | 3,500 ₹7,000 Lowest | 4,000 ₹8,000 |
| 3.00 | All as per item No 02 above but except bricks. | 0.5 | Cum | 2,500 ₹1,250 | 3,000 ₹1,500 | 1,500 ₹750 Lowest |
| 4.00 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4), complete all as specified and directed . | 5 | Sqm | 500 ₹2,500 Lowest | 3,500 ₹17,500 | 2,000 ₹10,000 |
| 5.00 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiling etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed . | 100 | Sqm | 10 ₹1,000 Lowest | 10 ₹1,000 Lowest | 10 ₹1,000 Lowest |
| 6.00 | M&L for rendering 15 mm thick cement plaster in cement mortar (1:6) on brick Work or concrete surfaces including finished even and smooth without using extra cement, complete all as specified and directed . | 59.17 | Sqm | 180 ₹10,651.3 | 150 ₹8,876.09 Lowest | 180 ₹10,651.3 |
| 7.00 | M&L for rendering 15mm thick in cement mortar (1:4) on of brick work or concrete surface, finish even and smooth (without using extra cement), incl WPC as per user manual, complete all as specified and directed . | 59 | Sqm | 190 ₹11,210 | 150 ₹8,850 Lowest | 180 ₹10,620 |
| 8.00 | M&L for rendering 10mm thick in cement mortar (1:3) over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth without using extra cement, complete all as specified and directed . | 15 | Sqm | 200 ₹3,000 | 200 ₹3,000 | 180 ₹2,700 Lowest |
| 9.00 | M&L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over a coat of primer including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as specified and directed . | 59 | Sqm | 50 ₹2,950 | 100 ₹5,900 | 25 ₹1,475 Lowest |
| 10.00 | M&L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over a coat of primer including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as specified and directed . | 15 | Sqm | 50 ₹750 | 70 ₹1,050 | 25 ₹375 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Aug 2025, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/REPLACEMENT TO DOORS, WINDOWS, VENTILATORS, CUPBOARDS, INTERNAL WIRING, SUMMER APPLIANCES, HOT WATER APPLIANCES, VARIOUS CAPACITY LT SWITCH GEARS I.E. MCCBS, ACBS, CONTACTOR, APFC PANELS, ACS AND OTHER CONNECTED WORKS AT AF STN 3 WING
2025_MES_720841_1
GE (FBD)/AF-T-35/2025-2026
Open Tender
Civil Works
Item Rate
180 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹80,000
Yes
6 Oct 2025
16 Jul 2025
9 Aug 2025
16 Jul 2025
6 Aug 2025
23 Jul 2025
Amount
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and directed .
M&L for Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed .
All as per item No 02 above but except bricks.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half bricks thick walls, built in cement mortar (1:4), complete all as specified and directed .
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiling etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed .
M&L for rendering 15 mm thick cement plaster in cement mortar (1:6) on brick Work or concrete surfaces including finished even and smooth without using extra cement, complete all as specified and directed .
M&L for rendering 15mm thick in cement mortar (1:4) on of brick work or concrete surface, finish even and smooth (without using extra cement), incl WPC as per user manual, complete all as specified and directed .
M&L for rendering 10mm thick in cement mortar (1:3) over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth without using extra cement, complete all as specified and directed .
M&L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over a coat of primer including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as specified and directed .
M&L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over a coat of primer including one layer of 3mm thick wall care putty on new plastered surfaces and obtain smooth finish using sand paper, complete all as specified and directed .
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrylic primer including one layer of 3mm thick wall care putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed.
Taking down chowkhats or frames with shutters not exc. 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames with shutters exc 1.5 Sqm but not exc. 4 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description n exc 1 sqm each, complete all as specified and directed.
Taking down shutters of any description exc. 1 sqm and n.exc. 2 sqm each, complete all as specified and directed.
M&L for pressed steel frames of size 105mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar (1:6), complete all as specified and directed.
All as per item No 16 above but size of frame 125mmx60mm for doors.
S&F for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and Grade 1 quality, 1mm thick any type of colour sunmica face is covered with decorative face veneer with lipping/frame to match, complete all as specified and directed.
S & F of 35 mm thick (Batten thickness) 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without shash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and sizes of the members of shutters as specified in clause No . 8.24 (a) of MES schedule part – I (Specifications - 2009), supplied and fitted to chowkhats complete all as specified and directed.
S&F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type, complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl 3Nos- 100mm Aluminium hinges for each shutter, complete all as specified and directed .
S&F Aluminum anodized frame fo doors, windows, ventilators powder coating (Min thickness of powder coating 50 micron) with one or more rebated including jointing cleats for fixing etc complete all as specified and directed.
M&L for anodised aluminium powder coated (Minimum thickness of powder coating 50 micron) door shutter, aluminium section weighing not less than 0.55kg/RM including necessary 4.8mm th sheet glass ordinary quality / frosted glass or ACP sheet incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts,1xdoor stoper,1xHydralic door closer with each shutter any type incl taking down, complete all as specified all as specified.
M&L for anodised aluminium powder coated (Minimum thickness of powder coating 50 micron) window and ventilator shutters, aluminium section weighting not less than 0.55kg/RM incl necessary 4.8mm th sheet glass ordinary quality glass/ frosted incl joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 x 150mm aluminium handles, 3 x 100mm hinges aluminium, 2 x 150mm Aluminium tower bolts, complete all as specifiedd and directed.
M&L for aluminium Anodized powder coated (Minimum thickness of powder coating 50 micron) fixed frame of partiton or fixed window / ventilator, aluminium section weighting not less than 0.55kg/RM including 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading, complete all as specifed & directed
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples, complete all as specified and directed
S&F 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair, complete all as specified and directed.
S&F 10 -12 mm thick glass door, frosted with certain logo, fixed with floor spring, fixed on floor with two no's stainless steel handle of 300mm on each leaf and fixed partition arrangement including necessary provision to lock the door, completed all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads, complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads, complete all as specified and directed.
S&F in repair 3mm thick sheet glass, ordinary quality and with oil putty in Square n. exc 0.5 sqm in each pane including hacking out old broken glass from metal frame including punching or drilling out old glazing pins/spring clips and glazed with oil putty, complete all as specified and directed.
S&F 100mm butt hinges, medium weight, cold rolled mild steel and fixed, complete all as specified and directed.
S&F 150mm aluminium, anodised, barrel tower bolts of extruded section etc complete all as specified and directed.
S&F 200 mm Aluminium handles, cast type, anodised of extruded section complete all as specified and directed.
S&F for 250mm long aluminium alloy, anodised, sliding door bolt of 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections, complete all as specified and directed.
S&F in repair, 150 mm ordinay rat tail rod pattern springs including roller and rabber plate fixed to chowkhats in repairs including necessary welding if required, complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm, complete all as specified and directed.
M&L for preparation of new wooden surface any description not otherwise described and exc 10cm width or girth applying two coats of synthetic enamel paint over a coat of prink primer all as specified and directed.
M & L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint (first quality) complete all as specified and directed .
S&F second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
M&L for 18mm thick water proof solid high gloss UV coated Action Tesa Board smooth finish both sides of approved shade fitted with necessary arrangement as in kitchen cabinet back sides, partition, shutters and shelves, etc., fixed with solvent cement adhesive and stainless steel screws and providing 1mm thick PVC lipping to exposed edges, complete all as specified and as directed.
S&F extruded brass handle, fancy type as approved by the GE, polished, 150mm long (ISI marked), complete all as specified.
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified and directed.
S&F aluminium Fanlight catch with 14mm catch and fixed suitable for any shutters, complete all as specified and directed.
S&F 40 mm dia cupboard knobs fixed with nut, screw and washer of brass,bright finished, complete all as specified and directed.
S&F in repair for 25 mm dia decorative/fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement including taking down old existing pipes with accessories complete all as specified and directed. Note: the cost of brackets and knobs is deemed to be included in the quoted rate.
M& L for Glazed ceramic jointless light/coloured of size 300mmx450/350x600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar (1:4), including dismantling tiles etc, complete all as specified and directed. Note:- shade & design as approved by EIC/GE.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana white including roundening the edge of stone, complete all as specified and directed.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor finishes including demolition, complete all as specified and directed.
Easing and Adjusting without taking down any type wooden shutters exc 1 Sqm but n.exc 2 sqm each and refixing in same opening after replacement of defective portions such as wire cloth, beading, handles, hinges, locking arrangements complete all as specified and directed. Notes : Door closer, door spring, aluminium beading, preleminated gasket, aluminum beading, preleminated particle board, sheet glass shall be measured and paid separately under respective item of schedules.
S&F in repair of door closer, hydraulically regulated, design No 3, universal type, suitable for door shutters of 851 to 1000m in width and weifht between 61 to 80 kg etc, complete all as specified and as directed
S&F in repair 2nd class hard wood beading straight (any size) for glazed/gauged joinery, renewed incl mitered etc complete all as specified and directed
M&L for repairs to sliding door bolt, hinges, pintel, locking arrangment, spike, roller, roller rails etc of steel gate/Wicket gate including welding /riveting to bring the steel gate /wicket gate in service condtions etc complete all as specified and directed
S&F ventian blind for window including necessary items required for fix to wall complete all as specified and directed.
S&F in repair door seals made of aluminium strip powder coated 20 mm wide and provided rubber/ cotton mat lining fixed with screws to door shutters up to 1m width opening complete all as specified and as directed.
S&F in repair double legged door stopper of aluminium alloy with rubber complete all as specifified and as directed.
S&F in repair 4mm thick figured glass pane fixed in window shutter/ventilators including necessary beading/wooden beading andoil putty, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 60 above but 5 Amp socket outlet, independent.
All as per item No 60 above but on the same board.
All as per item No 60 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable.
All as per item No 60 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through PVC casing caping of ISI marked with fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators complete all as specified and directed. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 65 above but 5 Amp socket outlet, independent.
All as per item No 65 above but on the same board.
All as per item No 65 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly.
Supply & fixing in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed.
Supply & fixing in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed.
Supply & fixing in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed.
Supply & fixing in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed.
Supply & fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed.
S&F in replacement for modular switches 6 amps single pole one way complete all as specified and directed.
S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and directed.
S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and directed.
S&Fin replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed.
Supply & fixing in replacement of stepped type electronic fan regulator modular complete all as specified and directed.
S&F in repair ceiling rose complete all as specified and directed.
Supply & fixing in replacement of ding dong bell electric 230 volt AC complete all as specified and directed.
S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed..
S&F single pole blanking plate in the existing cover plate complete all as specified and directed.
Supply and fix modular white cover plate with frame 3 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 4 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 6 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame 8 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 3 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 4 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 6 module ISI marked complete all as specified and as directed.
Supply and fix modular metal flush box 8 module ISI marked complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4"x4" complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7"x4" complete all as specified and as directed.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8"x10" complete all as specified and as directed.
Supply & fixing in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 20 Amps complete all as specified and directed.
M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 6 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable acomplete all as specified and directed. NOTE :- 2 runs of 6 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
All as per item No 95 above but copper cable single core of size 4 Sqmm in two run with earth wire 4 Sqmm single run for continuity complete all as specified and directed. NOTE :- 2 runs of 4 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
All as per item No 25 above here-in-before but copper cable single core of size 2.5 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity. NOTE :- 2 runs of 2.5 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
M&L PVC insulated FRLS single core with strandard copper cable of size 2.5 Sqmm in two run and 2.5 Sqmm one run for earth and drawing through ISI marked casing caping including taking down old UNSV cable complete all as specified and directed. NOTE :- 2 runs of 2.5 Sqmm cable and one run of 6 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and as directed.
Supply and fix in replacement LED bollard fitting 9 Watt with luminaire with MS Pipe housing with glare free PMMA diffuser , IP65 of height 800 mm suitable for single phase connection 50 Hz 230 Volts complete all as specified and directed.
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed.
S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and all as specified and directed.
M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed. .
Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries all as per specified and directed.
Supply and fixing in replacement of old unsv GI bracket made out of 32 mm bore,light grade 1.2 m long bent to shape suitable for street light fitting including MS flat clamp 50 x 6 mm 2 Nos for each bracket with nut & bolt complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete as specified and directed. Note : - MCCB shall be measured and paid separately
S&F sheet metal enclosures DB Double door Verticle distribution type, 08 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete as specified and directed. Note : - MCCB shall be measured and paid separately
S&F in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S&F in replacement MCB DB SPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
S&F in replacement MCB DB SPN 12 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
Supply & fixing in replacement of MCCB TPN 63Amps 16KA complete all as specified and directed.
S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed.
S&F in repairs MCB,SP 40 Amps, 240 Volts."B" grade complete all as specified and directed.
S&F in repairs MCB SPN, 40 Amps, 240Volts ."B" grade complete all as specified and directed.
S&F in repairs MCB SPN, 63 Amps, 240Volts."B" grade complete all as specified and directed.
S&F in repairs MCB TPN, 63 to 100 Amps,415Volts ."B" grade complete all as specified and directed.
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed.
Supply and fix modular type gang box(3 module for one socket and one switche) suitable for 5/15amp 6pin including plate cover plastic sunken box etc including suitable size of switches and sockets complete all as specified and directed.
Taking down storage water heater 25 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and as directed.
M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity ISI Make as per sample complete all as specified and directed.
M&L for replacement of heating element 1.5KW,Triangular/round type as per sample complete all as specified and directed.
M&L for replacement of heating element 2 KW with complete assembly of any model and type as per site requirement /sample complete all as specified and directed.
Material and Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and directed.
M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 16 SWG powder coated complete with all connected accessories suitably fitted with existing wall complete all as specified and directed.
M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed.
M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having PTMT nuts with washer complete all as specified and as directed.
S & F in replacement of bottom cover suitable cylindrical type geyser as per existing required as per site for 25 Ltrs capacity complete all as specified and as directed.
Dismantling and opening storage tank of geyser 25 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and as directed.
S & F in replacement of indication lamp red and green (pilit type ISI marked) for 25 Ltrs water heater complete all as specified and as directed.
Supply and fixing in replacement of PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitable for 650 volts grade complete all as specified and as directed.
S & F in replacement of glass wool in any capacity of geyser complete all as specified and as directed.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including servicing, greasing,oiling,replacing wornout bearing ,bush and refixing the same at site complete all as specified and as directed.
All as per item No 138 above but for Exhaust fan.
All as per item No 138 above but for wall/floor mounted fan.
Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and as directed.
All as per item No 141 above but for Exhaust fan 300 mm sweep.
All as per item No 141 above but for wall/floor mounted fan 450 mm sweep.
M&L Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for replacement of old unserviceable fan blades, (ISI Marked), suitable for 1200mm sweep ceiling fan duly painted in white/brown by using spray gun method(fully furnished) complete all as specified and directed.
M&L for repalcement of old unserviceable down rod of ceiling fan of dia 20mm bore "medium grade" complete with split pin, hanging clamp and rubber real (length of rod not less than 45cm and not more than 60cm) dully painted in white/brown by using spray gun method (fully furnished) complete all as specified and directed.
Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor cable of size 0.5 sqmm,3 core cut to size of approx 0.30 metre from block of fan to ceiling rose complete all as specified and directed.
M&L for replacement of old unserviceable gun metal bush of ceiling fan including neceassry laith, Grinding and welding work complete all as specified and directed.
M&L for replacement of old unserviceable shackle assembly kit (Rubber real -01, MS split clamp two Nos, nuts and bolts washers- 2 Nos & split pin -02 Nos) suitable for ceiling fan of 1200/1400mm sweep complete all as specified and directed.
M&L for replacement of old unserviceable steel screw of size 5mm to 8mm (to be used for fixing of fan blade) complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, and accessories 230V, 1200/1400mm sweep with squirrel cage induction motor complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix exhaust fan sweep 250 mm in replacement made up of sturdy engineering metal body complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed.
Supply and fix Ventilation fan PVC (250 mm Sweep) with louvers and acessories complete all as specified and directed.
Supply and fix Ventilation fan PVC (200 mm Sweep) with louvers and acessories complete all as specified and directed.
M&L for Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd (ISI marked) complete all as specified and directed.
M&L for Replacement of old unserviceable capacitor AC 400/415 volts 3.15 mfd (ISI marked) complete all as specified and directed.
M&L for servicing of split type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed. (a) Inspecting and checking the Indoor/outdoor units for noise free operation. (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower with water pressure gun. (d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage by pressure testing and repair it. (f) Checking for serviceability of remote control unit and replace with new battery.
M&L for servicing of window type AC's of capacity 1.5 TR comprising of the following tasks at different locations including Refixing, commissioning and testing complete all as specified and directed. (a) Inspecting, taking down, brushing cleaning with water pressure gun including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system by pressure test and repair it. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f) Inspection of all electrical parts. (g) Testing the machine for satisfactory operation.
M&L for repair to leaking area of split type AC unit of capacity 1.5/2 TR capacity including nitrozen pressure testing, dehydration and any type of gas charging complete all as specified and directed.
M&L for repair to leaking area of window type AC unit of capacity 1.5 capacity including pressure testing, dehydration and any type of gas charging complete all as specified and directed.
Supply and charging Refrigerant(R410,R32,R134 and existing refrigerent) to any type of AC unit including CFC free and non CFC Free AC complete complete all as specified and directed.
Supply and fixing in replacement of starting relay 25 Amps for split type AC units of capacity 2 /1.5TR as required at site complete all as specified and directed.
Supply and fixing in replacement of start run capacitor 45/60 MFD for split type A/C's of capacity 1.5/2 TR complete all as specified and directed.
Supply & fixing in replacement of running capacitor for 36/60 mfd for AC window type 1.5 TR as required at site complete all as specified and directed.
Supply & fixing in replacement of running capacitor 6 mfd for blower motor as required at site complete all as specified and directed.
Taking out and replacement of condenser fan motor DC of split type AC 1.5/2 ton units of capacity 1.5/ 2 TR complete all as specified and directed.
Taking out and replacement of condenser fan motor AC of split type AC units of capacity 1.5/ 2 TR complete all as specified and directed engineer-in-Charge.
M&L for fixing the new blower motor DC in replacement of for split type A/C unit as per existing model complete all as specified & directed.
Supply & Fixing the new blower motor AC for split type A/C unit as per existing model complete all as specified & directed.
Supply and fixing in replacement of new blower motor for window ac as required at site single phase 230 volts double shaft with clamp bolts, nuts and rubber bushes including testing & commissioning complete all as specified and directed..
S/F in replacement the new swing motor as per existing model/make for split type AC 1.5/2TR unit complete all as specified and directed..
Supply and fix out door fan blade in existing model complete all as specified and directed.
M&L for replacement of defective electronic components / IC Circuits of PCB card with display unit suitable of 1.5/2 ton split AC indoor unit as required on site including replacement of defective electronic components / IC Circuits complete all as specified and directed.
M&L for replacement PCB card suitable of 1.5/2 ton inverter split AC as required on site complete all as specified and directed by Engr-in-Charge including sensor complete all as specified and as directed.
M&L for replacement PCB card suitable of 1.5/2 ton window as required on site complete all as specified and directed by Engr-in-Charge including sensor complete all as specified and as directed.
Disconnecting and taking down burnt condenser coil of capacity 1.5TR from split type AC unit and Supply and Fix new copper condesor coil as per existing model complete including testing complete all as specified and directed..
M&L for replacement of cooling coil assembly complete suitable for 1.5 / 2 ton indoor unit Split type AC incl testing for satisfactory working condition complete all as specified and directed.
M&L for replacement cooling coil of window type AC 1.5 TR including after taking out old unserviceable one,soldering/welding dehydration complete achieve all as specified and directed.
Disconnecting & taking down of window type AC of any make for replacement of condenser coil of existing size including soldering/welding and resting commissioning complete all as specified and directed..
Disconnecting and taking down burnt compressor of capacity 1.5TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed..
M & L for Taking out unserviceable indoor unit and supply and fix the new indoor unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed.
Disconnecting and taking down burnt compressor of capacity 2TR from split type AC unit and Supply and fix new one as per existing model complete including testing complete all as specified and directed.
M&L for replacement of 'R' type compressor for Window type AC,1.5 TR as per existing make including taking out old unserviceable one,flushing, dehydration and gas changing complete as specified and directed.
Labour for dismantling of Split AC 1.5/2 ton complete unit from the existing place complete as specified and directed.
Labour for fixing of Split AC 1.5/2 ton including masonary work complete unit complete as specified and directed.
Labour for dismantling of window AC 1.5 ton from the existing place complete al as directed.
Labour for fixing of window AC 1.5 ton complete as specified and directed.
M&L install wall mounted stand for mounting indoor unit of split AC complete with all fixing arrangement complete all as specified and directed.
M&L wall mounted stand for mounting outdoor unit of split AC complete with all fixing arrangement complete all as specified and directed.
M&L in repairs copper tubing 3/8” outer dia suitable for AC 2TR capacity complete all as specified and directed.
All as per item No 191 above but 5/8” outer dia.
M&L for providing insulation 9mm thick for dia 1/4",3/8",1/2",5/8",6/8" copper tubing’s from Indoor to outdoor units with foam insulation followed with clamps complete all as specified and directed.
M&L for the new remote with battery as per existing model for 1.5/2 TR split type A/C unit complete all as specified & directed.
M&L in replacement of wall mounted Voltage stabilizers 4/5 KVA single phase,230 Volts AC,voltage variation between 140- 300,intelligent time delay system,digital display,low and high voltage cut-off system, all as specified and as directed.
M&L in replacement 3 core copper PVC insulated of size 4 Sqmm complete all as specified and directed.
M & L for Taking out unserviceable outdoor unit and supply and fix the new OUTDOOR unit of 1.5/2 TR capacity split AC 230 Volts single phase including installing ,charging complete all as specified and directed.
Repair & maintenance of Refrigerator / Water Cooler any capacity comprising of the following tasks at different location complete all as specified and directed. (a) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (b) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (c) Inspecting the leakage in the system. (d) Checking of the earth continuity of electrical parts. (e) Checking the functioning of thermostat. (f) Inspection of all electrical parts. (g) Testing the machine for satisfactory operation. (h) Check and correct all electrical wiring & test its functioning (j) Testing of Refrigerator after repair.
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of existing make including charging of refrigerant gas and testing on full load all as specified and directed .
M & L for replacement of unserviceable compressor with new compressor of existing make including charging of refrigerant gas and testing on full load all as specified and directed.
Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed.
M&L in replacement of wood pads(set of three)as per sample complete as specified and directed.
M&L in replacement the new desert cooler pump.including testing for proper functioning complete as specified and directed.
M&L in replacement the new exhaust fan kit with leg assembly 450mm sweep complete as specified and directed.
M&L in replacement the new exhaust fan motor with leg assembly 450mm sweep complete as specified and directed.
M&L in replacement the new exhaust fan blade 450mm sweep, Make Khaitan/Elpar complete as specified and directed.
M&L front grill of desert cooler as per sample complete all as specified and directed.
M&L for PVC flexible distributor heavy duty with nozzle as per sample complete as specified and directed.
M&L in repairs,Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete as specified and directed.
M&L in replacement of 3 pin socket metalic plug top industrial type complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed..
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart complete all as specified and directed..
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable and punned down 100mm to trenches complete all as specified and directed.
M&L for reinforced precast concrete cable cover for cable protection Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Taking down/ out XLPE PVC insulated LT cable 1100 Volts grade from loose / hard soil / of any size complete all as specified and directed..
Supplying, laying and testing XLPE cable, insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 volts grade (Heavy Duty) with stranded aluminium conducotr of cross secional area 10 Sqmm 4 core complete all as specified and directed.
All as per item No 218 above but cross secional area 16 Sqmm 4 core.
All as per item No 218 above but cross secional area 25 Sqmm 4 core.
All as per item No 218 above but cross secional area 50 Sqmm 3.5 core.
All as per item No 218 above but cross secional area 70 Sqmm 3.5 core.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as specified and directed.
M&L for 40mm dia of light grade GI pipe laid under road/floor/on pole for laying/fixing of cable complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 10 to 25 sqmm,Outdoor type complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 40 to 70 sqmm,Outdoor type complete all as specified and directed.
M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size complete all as specified and directed.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed. Note : - MCCB shall be measured and paid separately
S&F in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed.
Supply & fixing in replacement of MCCB 63Amps 16KA complete all as specified and directed.
S&F in replacement of MCCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed.
Supply & fixing in replacement of MCCB 160 Amps 4 pole 25 KA 415 volts complete all as specified and directed.
Supply & fixing in replacement of MCCB 250 Amps 4 pole 36 KA 415 volts complete all as specified and directed.
Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed.
S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and directed.
S&F in replacement of MCB TPN 40 amps 415 Volt complete all as specified and directed.
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed.
S&F street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed. Note :Brackets to be installed / grouted on wall or pole upto 11 mtr height.
S&F syntex street light box with 3 phase aluminium bus bar including 6 Amps SP MCB with mounting /fixing acessories complete all as specified and directed.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed.
M&L for writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level on PCC Poles complete all as specified and directed.
M & L for earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed.
Supply and fix copper strip 20mm x 3.15 mm complete with insulators and fixing screws etc for roof/wall above ground level including removing u/s strips complete all as specified and directed.
Supply and fix aluminium strip 25 mm x 4 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed.
Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long all as specified and directed.
S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.
M&L 32 mm GI pipe light grade of 1.3 mtr piece fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed.
NAVYUG VYAPARI (BID ID -3384648)
M/S Yamin (BID ID -3369320)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .