Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC 1ST FLOOR RAGHUNATH MARKET NEAR TELEPHONE EXCHANGE PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹23.3 L+₹58,551 (2.57%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹26.5 L+₹3.8 L (16.6%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹26.7 L+₹4.0 L (17.4%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in Appropriate Cat |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Feb 2024, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu, Near Gurdwara Sahib and Mandir, Airforce Station Satwari, Jammu. Pin - 180 003
REPAIR TO 66 KV SWITCHYARD AT AF STN PATHANKOT
2024_MES_635528_1
CWEAFJ-27/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
All as per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Pathankot
₹70,000
Yes
19 Apr 2024
3 Jan 2024
8 Feb 2024
3 Jan 2024
5 Feb 2024
22 Jan 2024
Amount
Testing, recording and servicing of following mentioned equipments installed at 66 KV sub station including switchyaed equipments for their smooth functuining (for six Monthly Basis) (i)POWER TRANSFORMER (a) Oil level/ leakage/silica gel/Earthing (b)Testing controls such as Buchholz relay, Prv Trip, OSR Trip, Oil Temp- alarm/ Trip, winching Temp- alarm/ Trip, MOG alarm and their indication (c) Measurement of insulation Resistance values and polarization index including HT cables in the ckt. (d)IR Values of HT Cable (ii) SF-6 CIRCUIT BREAKER (a) Measurement of IR Values, contact resistance (b) Testing of Trip / close & closing / opening timing. (c) Checking of low gas alarm / lock out circuit, gass pressure. (d) Checking of operation of breakerfrom Local/ remote and also tripping of Breaker through protection relay.
(iii)CT and PT (a) Measurement of IR Values, tightning ofcontact (b) Checking of Oil leakage. (iv) ISOLATOR (a) Checking operation and positionof contacts, inter Locks and manual operation. (v)LIGHTNING ARRESTER (a) Measurement of IR Values, Leakage current/ earthing, Jumper check and counter meter readings. (vi)VCB 11 KV (a) Measurement of IR values of Breaker % Bus Bar in all ckts. (b)Contact resistance and bring timing test. (c) Operation of breaker through relay and master relay (d) Inspection of cable connection and tightness. Relay Testing-(a) Testing for conditioning of relay and their actual testing for pickup and operation timing. Setting of relays with set parameters as actual tripping relays. (b)Testing of all auxiliary relays for their functioning in the desired manner..
(c) Checking of metering system and all indication circuits (d) Checking of capacitor banks 66 KV C & R PANELS (a) Checking of healthiness of DC/AC circuit and their failure alarms. (b) testing. Setting of relays viz. REF, Differential relays, Overcurrent and Earth fault relays and their coordination. ( c) Checking of Trip ckt supervision relay , alarm and Facia annunciators. (d) Checking of metering system and all indication circuits. DC BATTERY AND CHARGER (a) Checking condition of battery, DC voltage per cell and charging current/ float/ Trickle.
Supply and top up/ refilling of Transformer oil conforming to IS 335 1993 latest amendments for replacing oil in the transformer with breaking capacity not less than 45 kv complete all as specified and directed.
Painting of old painted surface of Transformer 66/11KV by scrubbing out old paint and painting with two coats of spray paint and one coat heat resistant metallic smoke grey paint complate including writing MES No. on Transformer body with black paint for 6.3/8MVA complete all as specified and directed.
Painting of old painted surface of Transformer 11/0.433 KV by scrubbing out old paint and painting with two coats of spray paint and one coat heat resistant metallic smoke grey paint complate including writing MES No. on Transformer body with black paint for 100 KVA sation transformer complete all as specified and directed.
Replacement of Silica gel in existing breather assembly complete all as specified and directed.
Cleaning of Sub Station and switchyard area by removing grass, weeds and any other vegetation including excavation inside it for protection forf growing of grass/ weeds for area measuring 1800 Sqm area. (Monthly cleaning of the sub stn and yard will be carried out) complete all as specified and directed.
Pea gravels 20 to 40mm graded hand picked ( any thickness) in sub station all as per latest engineering practice and directed by Engr-in-Charge.
Supply and fixing MS flat 65 x 5mm for connecting earthing electrode to fencing equipments , earthing mesh in the yard etc complete all as specified and directed by Engr- in charge. (in the ground level it is 60 cm below ground level). Cost of excavation wherever required will be deemed to be included in the quoted rates.
Repair to existing MS Flat strip of any size as laid in ground of fixed in any position in the switchyard by taking our for rerouting or welding all as required at site and directed by Engr-in-charge.
Supply and fixing end jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sqmm including taking down old, etc, complete all as specified and directed. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.
Supply and fix end jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm including taking down old, etc, complete all as specified and directed. NOTE:- Item rate quoted including required T&P/Refixing & Refilling in the panel/pole.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 11000 Volts grade of size 3 core 120 Sqmm including taking down old unserviceable complete all as specified and directed.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 50 Sqmm including taking down old unserviceable complete all as specified and directed.
Supply laying and testing cable XLPE insulated screended PVC bedded , galvanised steel strip armoured, electric power cables (heavy cable ) with stranded aluminium conductor , 1100 Volts grade of size 3.5 core 95 Sqmm including taking down old unserviceable complete all as specified and directed.
Dehydration including filteration and cleaning of transformer oil at different locations by stream line method dehydration plant including testing of samples before and after dehydration and filteration . Dielectric strength should not be less than 45 KV at 2.5 mm gap after dehydartion all as directied. Note :- (i) Test result before and after filteration to be recorded as per the sample provided by Engr-in-charge. (ii) The rate quoted is deemed to be inclusive of making necessary connection and the connection to filteration plant from transformers and switchgear oil duly removing the inlet and outlet connections. (iii) For topping up transformer oil will be measured and paid separately under relevant item of schedule.
Supply & fixing MCCB 3 pole 415 volts with rupturing cap 25 KA 160 Amps ICS 100 %ICU thermal magnetic release including taking down old unserviceable complete all as specified and directed.
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire /Jumper/ clamps where required all as specfied and directed by Engineer-in-charge.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 40 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed.
Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed.
Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L in replacement of earth pit indicator board made out of MS sheet 6mm thick of size 25cm x 15cm fixed on MS flat of size 40 x 6mm x 1.2mtr(long) by means of nut, bolt/ welding duly painted with two coats of synthetic enamel paint over a coat of red oxide paint of approved colour including writing the letters of size not exceeding 60mm all as directed by Engineer - in - charge. The indicator should indicate the following :- (i) Earth Pit No. (ii) Earth result in Ohms (iii) Date of testing Note :- (i) Cost of excavation of earth in any type of soil/ rock for erection of earth pit indicator board removal (upto the 50 Mtrs from starting point) and returning filling in of soil/ rock is deemed to be included in the quoted rates.
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor/ JE/ AGE E/M all as directed by Eng-in-charge. Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates.
Dismantling the existing earth strip & relaying of G.I. earth strip 32x6mm and fixing properly with clamps nut bolts complete all as specified and directed.
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25mm x3mm aluminium strip , complete all as specified and directed.
Supply and fixing 70 Watts street light LED fitting, new generation energy saving, environmental friendly long life, versatile pressure die cast aluminium, IP66 with 10KV surge protection road way,luminaire with high power LED as light source with warranty option of 5 years and suitable driversetc connecting with 2.5 sqmm multi strandard aluminium conductor PVC insulated twin core weather proof cable from fitting to junction box and fixing to pole with and including bracket made out of GI pipe of 40mm dia light grade not less than 1.2 mtr long bent to shape, fixed to pole in any position with flat iron clamps of size 50x6 mm, complete all as specified and directed.
M&L for Chemical earthing complete with copper earthing plate electrode of size 900x600x5mm thick buried directly into ground vertically to the depth not less than 5.0 metre below normal ground level with top edge of earth plate not less than 4.0 metre below normal ground level,surrounding on the all size by charcoal, common salt and magnisium sulphate (or any chemical recommended by manufacturer for increasing earth conductivity) starting from the ground below earth plate in alternate layers including replacement of excavated soil with artificially treated soil (soil having low resistivity) connected to copper strip of size 50 x 6 mm earth lead by means of copper lugs, nut, bolts and washers, earthing strip protected by 50mm bore light grade GI pipe in floor and fixed with wall with proper size of Fe clamps and watering pipe 15 mmm bore GI light grade including wire mess , funnel PCC earth chamber pit with 1:2:4 type b-1 (using 20 mm graded crushed stone aggregate) including form work cement mortar with height 300mm above normal pit,
excavation and earth work in any type of soil including testing on completion for desired result of 1 Ω all as shown and specified in plate No 3 of SSR part-I 2009 complete all as specified and directed. Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Supply and fixing Copper strip 20 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking down old unserviceable complete all as specified and directed.
Supply and fixing Test point terminal block made out of gun metal or phosphourus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm long hex. head screw including taking down old unserviceable complete all as specified and directed.
Supply, erecting and fixing steel tubular swaged poles type 410 SP-55, 11 meter long, complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint over one coat of red oxide primer and 06 Nos bands/ straps with white and red post office box colour (30 cm wide each) synthetic enamel paint at a distance 30 cm from plinth block and numbering of poles with black synthetic enamel paint in 2.5 cm height including black bitumineous paint two coats on steel surface embedded in concrete foundation including taking down old unserviceable complete all as specified and directed. (Excavation and earth work, pcc foundation concrete shall be measured and paid separately)
Supply and fixing HT 11 KV, out door type gang operated air-break switch suitable for horizontal or vertical mounting fixed type complete with 9 insulators of rating upto 400 Amps including taking down old unserviceable complete all as specified and directed.
Supply and fixing lightning arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp including taking down old unserviceable complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size including taking down old unserviceable all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C2 using 20mm graded crushed stone aggregate as mass concrete for foundation complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as mass concrete for foundation complete all as specified and directed by Engineer-in-charge.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. All as specified and directed by Engineer-in-charge.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 3mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. All as specified and directed by Engineer-in-charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 300 kgs for unreinforced covers, class HV Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS:5820 with minimum average breaking load capacity 200 kgs for unreinforced covers , class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
Sand cushioning to underground cables providing a layer of 8cm thick before laying the cable and 15cm thick after laying,stretching and testing the cable complete all as specified.
Dismantling of old Mechanical on load changeover supply system Three Phase type and replacement Phase failure and under voltage monitoring of primary supply. Interlocked contactor switching. AUTO Changeover switching. Manual override of supplies. Supply available indication. Supply in use indication. Adjustable time delay between switching. with new on load auto interlock changeover system equipped with two switchgear contactors not less than 16 Amps three pole and following parameters Limit the Inrush Current, Improve the THD/PF at Light Load or High Line, Improved Stability with a Type 2 Compensation Network--Phase Unbalance, Auto Phase Reversal tripping suitable for 3 phase load of Potential Transformer , Phase Missing Under Voltage and Over Voltage Monitor and Control, Neutral Open Protection. ALSO SPECIAL ZERO CROSSING SWITCHING OPERATION PROTECTION SYSTEM BUILT WITH SCROLLING DIGITAL DISPLAY OF LINE PHASE VOLTAGES AND LINE CURRENT
INCLUDING FREQUENCY AND POWER FACTOR Phase Un-balance (1 to 20%) (Adjustable) Power consumption 15VA / 3W Setting Accuracy voltage ± 4V, Minimum setting current 0.5A, Maximum setting current =5A (Above 5A - external CT setting max.1000/5 in steps of 5), Setting Accuracy Current ± 5% of full scale ±1digit, Trip time delay1 to 250secs settable for UB, OV, UV , Trip time accuracy± 1% of set delay ±2sec., Trip setting, Phase failure 3 sec Max. factory set., Phase Reversal Auto tripping, Phase Un balance1 to 20% (Adjustable), Under Voltage and over voltage 5V to 60V AC (Adjustable Individually ), Recovery Time2 sec Min Power On Delay10 sec Max., Service life(under no load) 10Lakh operations minimum , Electrical life, (under full load) 10 Lakh operations minimum Protection system should be provided with each fault digital ,Compensation of each phase, Measure power factor , total watts, total VAr, total KWH, Total KVArh, Programmable THD protection, Programmable Discharge Time. NOTES : 1. The Contractor has to submit Original Purchase Vouchers, Test Certificates & Guarantee Certifica before installation at site
Dismantaling of old unservicable card,relays, contactor and MCCB depositing back to MES store yard and replacement with new featured PHASE LINE TO LINE and LINE TO NEUTRAL Integrated micro chio programable output Flux regulation card designed for high speed synchronous motor connected with RC network for servo stabilizer for load not less than 400 KVA and also not exceeding more than 300 KVA Capacity built with auto load detector for three phase built with integrated operational difference voltage amplifier LT operated for over voltage sensor circuit up to 300 volts & lower voltage sensor circuit starting from 120 volts with 01 volt sensitivity relay set unit consisting of Vaccume impregnated step down transformer standing primary voltage up to 500 volts with 1100 volts insulation & standing 1100 volts for 03sec Secondary with potential voltage 20 volts going to electromagnetic relay units and next to Micro switches unit of existing Motor for sharp regulation at 233Volts ( +/- ) 1% (Adj.) also featuring RC Filters arrangement for provision to rotate clockwise / Anti clock wise with current consumption less than 01 amps with timer restriction not to be activated more then 05 sec in one operation i.e. .
433KV regulated including following features solid state electronic sensor design for exsisting 3 phase servo stabiliser Output impedance shall be 3.0 to 5.0 percent, The programmer shall be manufactured such that it will maintain electrical properties, even under severe overload, under/over voltage and under/over frequency conditions. Input correction range shall be -30% to +20% of nominal input voltage. The system design shall be capable of operating at an input frequency range of -15% to +10% of nominal, without clearing protective devices or causing component failure within the protection . Upon turn on or restart, the output of the exsisting Servo shall not exceed the specified output regulation limits. if the input voltage or frequency exceeds programmable minimum or maximum set points for a programmable time period (factory set for 10 seconds), the micro processor card shall electronically shut off command to new the installed MCCB as per load in Amps with minimum 25 KA rupturing capacity with new shunt tripp coil as per site requirement with on delay not to exceed 2 sec . When electrical parameters are back within acceptable limits for a programmable time period (factory set for 60 seconds), the MCCB shall manualy restart to provide conditioned power to the load.
If the input parameters are within acceptable limits, but the output voltage is outside of acceptable programmed limits, the output sensor card of any phase out of three phase shall electronically shut off and require a manual restart. The Micro Card shall be capable of operating at 100% rated load capacity continuously, 200% rated load for 10 seconds, 500% rated load for 1 second and 1000% rated load for 1 cycle. Operating efficiency shall be a minimum of 96%, typical at full load. Response Time: The protection unit shall respond to any line voltage variation in 1/2 cycle while operating linear or non-linear loads, with a load power factor of 0.60 of unity. Peak detection of the voltage sine wave shall not be permitted to avoid inaccurate tap switching due to input voltage distortion. Line Voltage Regulation and Correction Time: Output regulation shall be +5%, -6%, given an input voltage variation of -30% to +30% for nominal, when within +/-5% of the nominal frequency. The Micro card shall be equipped with both “Input Out of Range” , “Output Out of Range” indicators light shall be provided on the meter face to indicate that the input/Output voltage or frequency has exceeded acceptable limits. Metering: A digital input meter shall be provided to display line voltages, line currents, frequency, kVA, kW, and power factor. NOTES : 1. The Contractor has to submit Original Purchase Vouchers, Test Certificates & Guarantee Certificate before installation at site
JAI DURGA CONSTRUCTION CO
M/S SINGH AND ASSOCIATES
Ashoka Engineers
Bidder Name
JAI DURGA CONSTRUCTION CO
Ashoka Engineers
M/S SINGH AND ASSOCIATES
JCC ENGINEERS PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .