Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC Lowest tender | |
| 2 | L2₹16.5 L+₹3.5 L (26.7%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹16.6 L+₹3.5 L (27.1%)Rejected-Finance 239 PHASE 2 MODEL TOWN BATHINDA BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹16.6 L+₹3.6 L (27.4%)Rejected-Finance 65 DEEP NAGAR BIRRING ROAD JALANDHAR CANTT PB | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹16.8 L+₹3.7 L (28.7%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | L5 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹38,600
Closing Date
1 Oct 2020, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_371371_1
CA NO CWE/JAL/W-43/2020-21 8320/43/E8
Open Tender
Civil Works
Item Rate
180 days
Jalandhar Cantt
Class E Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer West JRC
₹38,600
Yes
26 Oct 2020
22 Aug 2020
3 Oct 2020
22 Aug 2020
1 Oct 2020
5 Sept 2020
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land complete all as specified and directed
Dismantling wall and ceiling boards, fiber, pulp, insulations etc or insulation boards any thickness including cover fillets complete all as specified and as directed.
Demantling asbestos cement (corrugated, semicorrugated,etc) sheets in roof coverings including wind tie complete all as specified and directed.
Dismantling of brick work or stone/boulders masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars etc. and rubbish materials remove from site all as specified and directed
Demolition of cement concrete in any position (unreinforced) n. exc. 15cm thickness complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section, unframed work, in any position complete all as specified
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-charge.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement complete all as specified.
M&L for non skid joint free ceramic coloured tiles of size exc 0.18 Sqm and not exc 0.38 Sqm, 7-8mm thick in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
S & F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding fixed to wall, fixed with self tapping screws as specified complete all as specified and directed.
S & F pre- painted galvalume aluminum zinc coating GI based corrugated two piece adjustable plain wing ridge 6mm thick complete all as specified and directed.
M&L 10mm thick plaster of paris false ceiling size 595x595mm (Gypsum anhydrous) to flat surface over metal frame work and reinforced with GI wire mesh (metal frame work to be measured separately but GI wire mesh is included in rate of this item)
S&F anodized aluminium snap grid frame work for false ceiling incl all accessories, complete all as specified and directed (size of grid as directed by Engr-in-Charge).
M&L Hangers 6mm dia GI (upto 1200mm length) adjusting level fized to roof slabs by means of ceiling cleats made out of G.I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long all as specified and directed
S&F mild stell flat iron as in wind ties conforming ot Fe-290 Gde E-165 all as specified and directed
S&F roof trusses (framed), trusses, as purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) and similar works conforming to Gde Fe-410 W (Gde-E-250) Quality B all as specified and directed
S&F second class hard wood as in scentling clean sawn as framed work complete all as specified and directed
M&L 15mm thick plastering on other than fair faces of bricks or concrete surfaces finished even and smooth without using extra cement in cm 1:6 all as specified and directed.
M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth without using extra cement in cm 1:6 all as specified and directed.
Material & labour for preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of white wash complete all as specified and directed by Engr -in-charge.
M&L for complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and apply two coat of white wash incl preparation of old wall surface complete all as specified and directed by Engr -in-charge.
M&L for complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and apply two coat of cement base paint complete all as specified and directed by Engr -in-charge.
Material & labour for preparation of new wooden surfaces of any girth any description and treated with tar or coal tar black paint complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed by Engr -in-charge.
M&L for prepration of old steel surfaces of any description not otherwise described over 10 cm width or grith and applying two coat of synthetic enamel paint complete all as specified and directed by Engr -in-charge.
Material & labour for preparation of old wooden surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed by Engr -in-charge.
M&L for two coats of oil bound distemper on ceiling over a coat of primer complete all as specified and directed by Engr -in-charge.
M&L for cleaning and removing sludge/soil mud, etc at blockage of sewage pipe line of 150mm bore by rodding manually from both side at manhole/gully trap of any depth/size and flushing with water till clear flow of water is observed at the lines, complete all as specified and directed
Taking down carefully existing point wiring aluminum/ copper conductor for light or fan or socket or power etc on wooden batten or in conduit including fittings and accessories like switches, sockets, lights fitting, regulator, wooden board and making good disturbed portion to match with existing complete all as specified and directed.
Material & labour for concealed point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated and unsheathed cable 1100 volts multistranded, copper conductor cable (FRLS) drawn through and including PVC concealed conduit not less than 20mm dia bore medium grade (ISI marked) and accessories like bends, tees, junction boxes etc, fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire including sunken type pressed steel terminal boxes and plastic laminated white/ coloured top sheet cover 3.0 mm thick , for One light point / fan point / call bell point controlled by one way switch complete all as specified and directed.
All as per item No. 31 above but one 3 pin socket outlet 5 amps on independent board with other switches, complete all as specified and directed. .
All as per item No. 31 above but one 3 pin socket outlet 5 amps on same board with other switches, complete all as specified and directed. .
All as per item No. 31 above but with 2.5 sqmm multistranded copper conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board, complete all as specified and directed.
All as per item No. 31 above but with 4 sqmm multistranded copper conductor FRLS cable for AC on independent board, complete all as specified and directed.
Supply and fix switch piano flush button type, 5 Amps, 230V AC, single pole, one way complete all as specified and directed
Supply and fix socket out let multi purpose 5 pin 5 Amp flush type 230/250 volts complete all as specified.
Supply and fix socket combination multi purpose 6 pin 15 Amp flush type 230/250 volts complete all as specified.
Taking down U/S sub main wiring of any size and make as specified and directed
M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn through PVC concealed conduit of size 25 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engr-In-Charge Note: Two run of 6.00 Sqmm cable and one run of 6.00 earth wire & 25 mm PVC conduit shall be measured as one unit length.
Supply and fix lamp holder PVC/Polycarbonate type with back plate with and including 5 Watt LED bulb complete all as specified and directed
S&F stepped type socketed type electronic fan regulator flush type as directed by Engr in Charge
S&F exhaust fans heavy duty AC single phase 230/240 volts of size 300mm sweep, heavy duty, metal body with louvers/shutters and connecting with 3 core 1.5 Sqmm copper conductor PVC insulated wire from fan to ceiling rose completed all as specified and directed
Supply & fix in replacement LED light fitting 22W retrofit including LED lamp with 2100 lumen output with internal surge protection device of 4KV with voltage band of 140-280V CRI-6500K (White light) fixtures box type with retrofit LED rod 22 watt and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed. Make :Havells cat part No. LUMLINEPLUSBS22WLED865SPCSS or equivalent as mentioned in appendix 'B'
Supply and fix in replacement LED street light fitting 60W Endura Pearl Plus including LED lamp pressure die cast aluminium IP66 with surge protection device pf 10KV, 1K7, LED (SEOUL) 6500K and making electrical connections to ceiling rose using PVC insulated and overall sheated flexible copper conductor of size 0.75 Sqmm 3 core fixed in repairs complete all as specified.
S&F in repair plug and socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps complete with metal clad socket Make: Standard/Anchor/Havells.
Supply and fix ceiling rose surface bakelite 65 x 50 mm three terminal PVC / Polycarbonate isolated body complete all as specified.
S&F in reapair 34 Watt 2 x 2 LED Pluto Neo ceiling fitting light ultra modern designed, LED luminaire which provides soft-light and glare free symmetrical illumination suitable for armstrong/Grid ceiling, including Bracket nuts, bolts washer as required for fixing all as specified and directed
Taking down main switch/DB of any size and making good disturbed surface complete all as specified and directed
Supply and fixing Sheet metal enclosure for double door DBs when MCBs to be used TPN 4 way with 200amps rated bus bar double door type complete with incoming/outgoing connection through proper size of lugs complete all as specified and directed.
Supply and fixing isolator TPN 63 amps , 415 volts, complete all as specified and directed. Make: Hevells
Supply and fix DB, double door, SPN 8 way for MCB, 240 volt with 200 amps rated bus bar complete all as specified and directed.
S&F for isolator SPN 40 Amp 240 volts complete all as specified and directed.
Supply & fix MCB SP, 6 to 32 amps, 240 Volts complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr deep below normal ground level connected to GI earth wire 4 mm dia connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to O/H continuous earth wire on pole, testing the earthing after completion complete all as specified and directed. Note :- (I) Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit (II) PCC chamber shall be (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways complete all as specified and directed. .
Supply, laying, testing and commisioning XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor size 25 sqmm 4 core.
Excavation in trenches in in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning filling layers including leveling watering and well ramming in layers not exc. 25cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested all as specified and directed at site.
M&L for river sand cushioning with a layer of sand 8 cm before laying of cable and 15 cm after laying of cable all as directed by Engr-in-Charge Note: Punned down thickness shall be measured.
Removing excavated surplus soil (Soft/loose) obtained from excavation to a distance n.exe 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed.
Supply and laying of old size sub class brick laid in trenches over the cable for protection all as specified
Supply and laying 40mm dia GI tubing medium grade complete with all fittings (ISI marked) laid in trenches/fixed complete to wall and ceiling or laid in floors complete all as specified.
M/S Vinod Kumar
SARASWATI CONSTRUCTION CO
NIRMAL SINGH
NATIONAL BUILDERS
M/S Kuldip Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .