| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.5 L+₹2.2 L (7.67%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.3 L+₹4.0 L (14.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | P S BUILDERS L3 | kailu construction co L1 | VIRAT CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|
| 1.00 | AIR CONDITIONER Taking out existing unserviceable compressor sealed unit from window/split type air conditioner 1.5 / 2.0 Ton capacity including removal of unserviceable strainer filter etc. complete all as specified and directed by Engineer-in-charge. | 36 | Each job | 158 ₹5,688 | 100 ₹3,600 | 50 ₹1,800 Lowest |
| 2.00 | S&F in replacement and connecting of new compressor sealed unit of capacity 1.5 Ton for window/ split type suitable for air conditioner of any make/as per existing type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, vacuuming the system, supply and charging Gas (R-22/R-134A), detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed by Engineer-in-charge. | 25 | Each job | 8,758 ₹2,18,950 | 8,000 ₹2,00,000 | 6,500 ₹1,62,500 Lowest |
| 3.00 | All as per srl item No. 02 here-in-before but of 2.0 Ton capacity. | 11 | Each job | 9,758 ₹1,07,338 | 9,000 ₹99,000 | 6,800 ₹74,800 Lowest |
| 4.00 | M&L for leak detection by nitrogen pressure test in refrigerant system for split/ window type AC 1.5 TR capacity, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desired cooling including installation at site and testing on full load for 24 hours complete all as specified an directed. (Note:- Additional gas required will be measured & paid separately under relevant item as supply only). | 30 | Each job | 58 ₹1,740 Lowest | 300 ₹9,000 | 850 ₹25,500 |
| 5.00 | All as per Srl item No. 04 here-in-before but of 2.0 Ton capacity. | 21 | Each job | 58 ₹1,218 Lowest | 350 ₹7,350 | 850 ₹17,850 |
| 6.00 | Taking down blower motor from air conditioner of 1.5 / 2.0/ 2.5 Ton capacity and make / and fixing as per existing type and replacing with the new motor, single phase, 200/230 volt, 50 Hz, 1/5 HP capacity, ISI Marked in the same position, testing etc complete all as specified and directed by Engineer-in-Charge. | 20 | Each job | 758 ₹15,160 Lowest | 1,000 ₹20,000 | 1,150 ₹23,000 |
| 7.00 | S&F in replacement of running capacitor (36 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 35 | Each | 58 ₹2,030 Lowest | 250 ₹8,750 | 180 ₹6,300 |
| 8.00 | S&F in replacement of starting capacitor (100/120 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 35 | Each | 98 ₹3,430 | 150 ₹5,250 | 85 ₹2,975 Lowest |
| 9.00 | S&F in replacement of thermostate switch of temperature range of 16°C to 30°C suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 30 | Each | 58 ₹1,740 Lowest | 110 ₹3,300 | 100 ₹3,000 |
| 10.00 | S&F in replacement of grill with knob made of fiber plastic body suitable for window type AC of any make /type/ capacity complete as per existing make all as specified and directed by Engineer-in-Charge. | 5 | Each Job | 558 ₹2,790 Lowest | 1,500 ₹7,500 | 1,150 ₹5,750 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 Mar 2026, 6:00 pmClosed
Garrison Engineer, Gurdaspur.
Garrison Engineer, Gurdaspur (Tibri)
Repair/ replacement and maint of summer appliances such as AC window/ split type, refrigerator, water cooler, desert cooler and voltage stabilizer at Tibri Mil Stn under GE Gurdaspur.
2026_MES_752241_1
GE GSR-96/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Garison Engineer
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹98,000
20 Apr 2026
11 Feb 2026
13 Mar 2026
11 Feb 2026
6 Mar 2026
27 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | AIR CONDITIONER Taking out existing unserviceable compressor sealed unit from window/split type air conditioner 1.5 / 2.0 Ton capacity including removal of unserviceable strainer filter etc. complete all as specified and directed by Engineer-in-charge. | 36 | Each job | - | - |
| 2 | S&F in replacement and connecting of new compressor sealed unit of capacity 1.5 Ton for window/ split type suitable for air conditioner of any make/as per existing type including replacement of foundation bolts, rubber pad, strainer capillary tubes, suction and discharge pipe line, wiring kit, vacuuming the system, supply and charging Gas (R-22/R-134A), detection of leakage etc., brazing and testing to achieve proper cooling effect complete all as specified and directed by Engineer-in-charge. | 25 | Each job | - | - |
| 3 | All as per srl item No. 02 here-in-before but of 2.0 Ton capacity. | 11 | Each job | - | - |
| 4 | M&L for leak detection by nitrogen pressure test in refrigerant system for split/ window type AC 1.5 TR capacity, cutting brazing and making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas of any type as required quantity to achieve desired cooling including installation at site and testing on full load for 24 hours complete all as specified an directed. (Note:- Additional gas required will be measured & paid separately under relevant item as supply only). | 30 | Each job | - | - |
| 5 | All as per Srl item No. 04 here-in-before but of 2.0 Ton capacity. | 21 | Each job | - | - |
| 6 | Taking down blower motor from air conditioner of 1.5 / 2.0/ 2.5 Ton capacity and make / and fixing as per existing type and replacing with the new motor, single phase, 200/230 volt, 50 Hz, 1/5 HP capacity, ISI Marked in the same position, testing etc complete all as specified and directed by Engineer-in-Charge. | 20 | Each job | - | - |
| 7 | S&F in replacement of running capacitor (36 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 35 | Each | - | - |
| 8 | S&F in replacement of starting capacitor (100/120 mfd) suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 35 | Each | - | - |
| 9 | S&F in replacement of thermostate switch of temperature range of 16°C to 30°C suitable for air conditioner of any make / type / capacity including making connection etc complete all as specified and directed by Engineer-in-Charge. | 30 | Each | - | - |
| 10 | S&F in replacement of grill with knob made of fiber plastic body suitable for window type AC of any make /type/ capacity complete as per existing make all as specified and directed by Engineer-in-Charge. | 5 | Each Job | - | - |
stage.html
html • 0.05 MB
technical_842535.pdf
techsummary_842535.pdf
finance_842535.pdf
BOQ Comparative Chart
xlsx
finsummary_842535.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
96TenderDocuments.pdf
Tender Documents • 0.69 MB
BOQ_842535.xls
BOQ • 1.57 MB
96Corrigendum01toBOQandtenderdocus.pdf
PDF • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .